0% found this document useful (0 votes)
2 views

user_DH_DIXL

The document provides safety instructions and operational guidelines for a freezer, emphasizing the importance of proper electrical connections and maintenance procedures. It includes information on warranty coverage, operational temperature ranges, and specific models with their electrical specifications. Users are advised to follow all instructions to prevent fire hazards and ensure the unit operates correctly.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
2 views

user_DH_DIXL

The document provides safety instructions and operational guidelines for a freezer, emphasizing the importance of proper electrical connections and maintenance procedures. It includes information on warranty coverage, operational temperature ranges, and specific models with their electrical specifications. Users are advised to follow all instructions to prevent fire hazards and ensure the unit operates correctly.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 25

To reduce the risk of fire, electric shock or injury to persons using this freezer, read all instructions and

follow
basic safety precautions before using the unit, including the following:

Do not modify the plug provided with the unit. If it will not fit the outlet,
have a proper outlet installed by a qualified electrician.

Do not position equipment so it is difficult to disconnect from the power supply.

While under warranty, do not attempt to repair or replace any part of the
freezer for servicing without first contacting the Service Department.

BEFORE CALLING THE MANUFACTURER’S TECHNICAL SUPPORT DEPARTMENT


Please have the model number of the unit, box identification number, and serial number ready as
well as the problem description. The model, serial number and box id number can be found on
the serial tag, which is located on the interior left upper wall, or back of the unit.

SAVE THESE INSTRUCTIONS



● PRE-INSTALLATION INFORMATION…...…………………………………...

● MOISTURE DURING THE SUMMER SEASON…….……………………...

● OPERATIONAL TEMPERATURE RANGE……………………………….….
● ELECTRICAL SPECIFICATIONS….…...…………………………………….
● REFRIGERATION SPECIFICATIONS……………………………….……….

● CLEANING AND DEFROST PROCEDURE………….…………………….
● CLEANING THE CONDENSER…….……………………………………….

● CONTROL PROGRAMMING………………………………………………….
● HOW TO CALIBRATE THE CONTROL……….……………………………...

● MONITOR PROBE FOR FIELD INSTALLATION…………………...……….
● DOOR HINGE ASSEMBLY ILLUSTRATION.……………..….……………...
♦ HOW TO ADJUST THE DOOR SPRING (SGD UNITS)
♦ CONTROL SETTINGS
● BASIC CONTROL SETTINGS….…………………………………………….
● ADVANCED SETTINGS……...………………………………………………...

● THE HIDDEN MENU……………………………………………………………
● FOR THE SERVICE TECHNICIAN R290…………………………………….

● REFRIGERATOR REVISION 3-1-2016 ……….…………………………….
● REFRIGERATOR REVISION 2-1-2013 TO 2-29-2016…...………………...

● FREEZER REVISION 3-1-2016 ……….…………………………….
● FREEZER REVISION 2-1-2013 TO 2-29-2016…...………………...








CAUTION
DO NOT CONNECT TO GFI / GFCI OUTLETS. CONNECTION TO THAT
TYPE OF OUTLET CAN RESULT IN PRODUCT LOSS DUE TO UNSAFE
CABINET TEMPERATURE WHEN GFI DEVICE TRIPS FROM MOISTURE.

DO NOT USE EXTENSION CORDS AND DO NOT DISABLE OR BY-PASS


GROUND PRONG ON ELECTRICAL PLUG
REFRIGERATOR : 2°C TO 8°C / 36°F to 46°F
FREEZER : -18°C to -20°C, -25°C / 0°F to -13°F

115 VOLTS
60 HERTZ
1 PHASE 15 AMP
DEDICATED LINE NEMA 5-15
(SUPPLY VOLTAGE SHOULD NOT VARY MORE UNIT IS PRE-WIRED AT FACTORY
THAN 5% FROM SERIAL PLATE RATINGS.) INCLUDES 8’ CORD
INCLUDES PLUG SET

DH4-8GD DH4-23GDSS DH4-25PT


DH4-12GD DH4-23SDSS DH4-50PT
DH4-15GD DH4-27GDSS DH4-80PT
DH4-23GD DH4-27SDSS
DH4-23SD DH4-49GDSS
DH4-27GD DH4-49SDSS
DH4-27SD DH4-72GDSS
DH4-30GD DH4-72SDSS
DH4-30SGD
DH4-38SGD
DH4-45SGD
DH4-49GD
DH4-49SD
DH4-66SGD
DH4-74GD
DH4-74SD

ELECTRICAL PLUG
• PLUG THE UNIT INTO THE PROPER OUTLET WITH AN ADEQUATE POWER SUPPLY.
• THIS UNIT REQUIRES A DEDICATED ELECTRICAL LINE.
• UNIT PRE-WIRED AT FACTORY AND INCLUDE 8’ LONG CORD AND PLUG SET.
ENERGY
MODEL STAR KWH/DAY AMPS / HP / BTU/HR REFRIGERANT
RATED

DH4-8GD 2.12 1.15 A / 1/8 HP R600A – 1.59OZ.

DH4-12GD 2.39 4.1 A / 1/6 HP R290 – 1.94 OZ.

DH4-15GD 1.82 7.0 A / 1/3 HP R290 – 2.29 OZ.

DH4-23GD
DH4-23SD
2.04 3.0 A / 1/4 HP / 1480 BTU/HR R290 – 2.12 OZ.
DH4-23GDSS
DH4-23SDSS

DH4-27GD
DH4-27SD
2.05 3.0 A / 1/4 HP / 1480 BTU/HR R290 – 2.12 OZ.
DH4-27GDSS
DH4-27SDSS

DH4-38SGD 5.4 A / 1/3 HP / 2392 BTU/HR R290 – 3.0 OZ.

DH4-45SGD 3.38 5.4 A / 1/3 HP / 2392 BTU/HR R290 – 3.0 OZ.

DH4-49GD
DH4-49SD
3.21 5.4 A / 1/3 HP / 2392 BTU/HR R290 – 3.0 OZ.
DH4-49GDSS
DH4-49SDSS

DH4-66SGD 4.42 6.2 A / 1/2 HP / 2808 BTU/HR R290 – 3.2 OZ.

DH4-72GD
DH4-72SD
3.92 6.2 A / 1/2 HP / 2808 BTU/HR R290 – 3.2 OZ.
DH4-72GDSS
DH4-72SDSS

DH4-25PT 6.5 A / 1/3 HP / 2800 BTU/HR R290 – 5.3 OZ.

DH4-50PT 8.5 A / 3/4 HP / 4950 BTU/HR R290 – 5.3 OZ.

DH4-80PT 10.8 A / 1/3HP (2) /8400 BTU/HR R290 – 5.3 OZ.


CAUTION
DISCONNECT THIS UNIT FROM THE POWER SUPPLY
BEFORE PERFORMING MAINTENANCE ON THE UNIT.



ATTENTION
IT IS RECOMMENDED TO CLEAN THE
CONDENSER AT LEAST ONCE EVERY
120 DAYS TO PREVENT DUST BUILDUP.
LED MODE FUNCTION

MESSAGE CAUSE








o
o


WARNING





FREEZERS

LINE 1- BLACK (LINE VOLTAGE)

LINE 2-ALARM OUTPUT TO RELAY- BLACK

LINE 3- COMPRESSOR- RED/ BROWN

LINE 4- FAN- BLUE

LINE 5- LINE VOLTAGE- BLACK

LINE 6- COMMON- WHITE

LINE 7- DEFROST- ORANGE

LINE 18- DOOR SWITCH- BLUE

LINE 20- DOOR SWITCH- BLUE

LINE 21- BLACK EVAP PROBE- BLACK (P4)

LINE 22- AIR PROBE - BLACK (P2)

LINE 23- COMMON LEG FOR ALL 3 PROBES

LINE 24- GLYCOL PROBE- BLACK (P1)

20
XR75-CX CONTROLLER
FREEZERS

LINE 1- BLACK (LINE VOLTAGE)

LINE 2-ALARM OUTPUT TO RELAY- BLACK

LINE 3- COMPRESSOR- RED/ BROWN

LINE 4- FAN- BLUE

LINE 5- LINE VOLTAGE- BLACK

LINE 6- COMMON- WHITE

LINE 7- DEFROST- ORANGE

LINE 18- DOOR SWITCH- BLUE

LINE 20- DOOR SWITCH- BLUE

LINE 21- GLYCOL PROBE- BLACK

LINE 22- EVAP PROBE- BLACK

LINE 23- COMMON LEG FOR ALL 3 PROBES

LINE 24- AIR PROBE - BLACK

21
SO-LOW ENVIRONMENTAL EQUIPMENT COMPANY

CINCINNATI, OHIO, USA

WARRANTY

So-Low Environmental Equipment Company as the Manufacturer WARRANTS the quality of all parts used in the
construction of this machine to be free from defects to the original purchaser.

a. This WARRANTY shall continue for 3 years from the original shipment date, i.e. 3 years from the time of
shipment from So-Low Environmental Equipment Company at Cincinnati, Ohio, U.S.A. This WARRANTY
shall not extend to shipments due to repairs or technical service after original WARRANTY has expired.

b. This WARRANTY shall have force and effect only if all items are used with proper circuits, voltages, and
frequencies and the operation thereof is in accordance with instructions furnished by the manufacturer.

c. This WARRANTY shall not extend to such parts as refrigerants, finishes, belts, and dryers.

d. This WARRANTY shall not extend to ordinary wear and tear, or ordinary refrigeration service and
refrigeration adjustments, unless specifically included in the equipment purchase contract.

e. This WARRANTY shall not extend in any way to liability (whether or not construed on tort or contract any
other theory of law) to consequential damages resulting from:

1. Ordinary use of the machine.

2. Abuse or misuse of the machine; such as high room ambient temperature, or operating the unit
out of the stated temperature range.

3. Interruption or cessation of the operation of the machine from any cause whatsoever, Including
but not limited to power failure, LOW VOLTAGE, acts of God, explosion, negligent operation and
the like.

“Consequential damages” shall be defined to include, but not limited to spoilage of, or damage to contents
placed in the machine, loss of profits, expenses of delay resulting from interruption or cessation of the
operation of the machine, loss of customers or business good will, any time element loss, or any other
special damages. Also, there is no guarantee for plus or minus temperature.

f. This WARRANTY shall extend only to furnishing for replacement a part found by the manufacturer to be
defective.

g. This WARRANTY shall not extend nor cover any part used as a replacement part beyond the original three
year machine WARRANTY: nor does the manufacturer undertake any obligation in connection with this
WARRANTY other than that specifically set forth above. No person is authorized to make any representation
as to this WARRANTY except duly authorized officers of So-Low Environmental Equipment Company.

h. SO-LOW ENVIRONMENTAL EQUIPMENT COMPANY agrees if instructions as to operation and use are
strictly followed, and power sources (circuits, voltages, frequencies, ect.) are properly applied, to provide
within three years after original delivery to shipper, labor free of charge to maintain equipment in good
working condition.

i. This WARRANTY shall extend replacement compressor parts to 4 additional years. This compressor
WARRANTY shall not extend nor cover any labor during this extended period.

j. This WARRANTY is limited to products purchased and installed in the United States of America.

You might also like