2386 - Rajendra Bagal - Sixth Floor Column Deatils - R0
2386 - Rajendra Bagal - Sixth Floor Column Deatils - R0
NOTES:-
1. ALL DIMENSIONS ARE IN 'mm' AND ALL LEVELS TO
BE REFERRED FROM ARCHITECTURAL DRAWINGS.
2. CENTER LINE PLAN SHOULD BE CHECKED BY THE
M SIXTH FLOOR TO SIXTH FLOOR ROOF LEVEL SIXTH FLOOR TO SIXTH FLOOR ROOF LEVEL SIXTH FLOOR TO SIXTH FLOOR ROOF LEVEL SIXTH FLOOR TO SIXTH FLOOR ROOF LEVEL
3. ARCH. REFER ARCHITECT'S DRAWING FOR ALL
OTHER DETAILS & DIMENSIONS.
M
4. FIRE RATING CONSIDERED :- 1 Hour Maximum
SIZE OF COLUMN 230 x 600 SIZE OF COLUMN 230 X 600 SIZE OF COLUMN 230 x 920 SIZE OF COLUMN 230 x 920 5. NOMINAL COVERS Mild Moderate Severe
(b * l) (b * l) (b * l) (b * l)
I. FOOTINGS 50 50 50
M30 : Fe500 , M30 : Fe500 , M25 : Fe500 , M25 : Fe500 , II. COLUMNS & WALL
COVER = 30mm COVER = 30mm COVER = 40mm COVER = 40mm 40 40 45
(TO LINKS OF COLUMN)
III. SLABS 20 30 45
230 230 IV. BEAMS
230 230 (TO STIRRUPS OF BEAM)
25 30 45
250
250
REINFORCEMENT REINFORCEMENT V. SHEAR WALL 30 30 40
ARRANGMENT ARRANGMENT
600
600
# FOR MAIN REINF. UP TO 12mm DIA. BAR FOR
L L
420
420
920
920
REINFORCEMENT REINFORCEMENT MILD EXPOSURE THE NOMINAL COVER MAY BE
ARRANGMENT ARRANGMENT REDUCED BY 5mm.
# FOR EXPOSURE CONDITION 'SEVERE' AND 'VERY
250
250
SEVERE' REDUCTION OF 5mm MAY BE MADE,
WHERE CONCRETE GRADE IS M30 AND ABOVE.
5. REFER STANDARD DRAWING'S FOR LAP LOCATIONS
TO BARS IN BEAMS AND COLUMNS .
6. IF UNAVOIDABLE, REINF. LAPS FOR BEAMS AND
SLAB SHALL BE STAGGERED WITH NOT MORE THAN
LONGITUDINAL LONGITUDINAL LONGITUDINAL LONGITUDINAL BARS SPECIFIED AT A SECTION.
REINFORCEMENT 10N-Ø16 REINFORCEMENT 8N-Ø12 + 2N-Ø10 REINFORCEMENT 12N-Ø16 + 4N-Ø12 REINFORCEMENT 8N-Ø16 + 4N-Ø12 + 6N-Ø10 7. FOR CANTILEVERS (SLAB or BEAM), TOP BARS TO BE
ANCHORED BEHIND FOR 75xDIA OR 1.5 X SPAN
WHICHEVER IS GREATER.
MID ZONE MID ZONE BOUNDARY ELEMENT MID ZONE BOUNDARY ELEMENT MID ZONE 8. LINKS IN COLUMN AT COLUMN-BEAM JUNCTION ARE
K NECESSARY. K
MAIN OTHER MAIN OTHER MAIN OTHER MAIN OTHER MAIN OTHER MAIN OTHER 9. WHENEVER THE DIMENTION OF COLUMN GETS
REDUCED, TIE BEAM OR PLINTH BEAM IS
NECESSARY IN THE SAME DIRECTION.
8Ø - 175 C/C 8Ø - 175 C/C 8Ø - 175 C/C 8Ø - 175 C/C 8Ø - 100 C/C 8Ø - 100 C/C 8Ø - 175 C/C 8Ø - 175 C/C 8Ø - 100 C/C 8Ø - 100 C/C 8Ø - 175 C/C 8Ø - 175 C/C 10. ALL STRUCTURAL CONCRETE SHOULD BE WEIGH
BATCHED, MACHINE MIXED & MECHANICALLY
VIBRATED
12. FOR SLAB SPAN ABOVE 4.5M, BACK PROPPING IS
MUST WHILE CASTING OF IMMEDIATE UPPER
FLOOR SLAB.
13. RESPONSIBILITY REGARDING CORRECT & SOUND
CONSTRUCTION, SHUTTERING SHALL SOLELY REST
WITH CONTRACTOR / OWNER. FOLLOWING
GUIDELINE MAY BE USES FOR STRIPPING OF
FORMS IN NORMAL CIRCUMSTANCES.
J 14. LAPPING OF REINFORCEMENT :-
DEVELOPMENT LENGTH (Ld)
J
GRADE OF REINF. M20 M25 M30 M35 M40 & ABOVE
Fe415 48xD 41xD 38xD 34xD 30xD
Fe500 (TMT) 57xD 49xD 46xD 40xD 36xD
COLUMN MARK C1, C9, C35, C41 COLUMN MARK C2, C3, C7, C8, C16, C22 COLUMN MARK C4, C6, C12, C15 COLUMN MARK C5, C38, C39
# FOR BUNDLED BARS, 'Ld' SHALL BE INCREASED
BY 10% FOR 2 BARS IN CONTACT, 20% FOR
3 BARS IN CONTACT AND 35% FOR 4 BARS IN
CONTACT.
BASEMENT + GROUND + 10
DESIGN VALID ONLY FOR
FLOORS + TERRACE FLOOR
S.B.C. CONSIDERED 52 T/SQM.
I GRADE OF CONCRETE M35/M30 I
SIXTH FLOOR TO SIXTH FLOOR ROOF LEVEL SIXTH FLOOR TO SIXTH FLOOR ROOF LEVEL SIXTH FLOOR TO SIXTH FLOOR ROOF LEVEL SIXTH FLOOR TO SIXTH FLOOR ROOF LEVEL Fe550
GRADE OF STEEL
SIZE OF COLUMN SIZE OF COLUMN SIZE OF COLUMN SIZE OF COLUMN ENVIRONMENTAL MILD
230 x 920 230 X 600 230 x 920 230 x 920 EXPOSURE CONDITION
(b * l) (b * l) (b * l) (b * l)
DESIGN LIVE LOAD FOR CAR PARKING
M25 : Fe500 , M30 : Fe500 , M25 : Fe500 , M25 : Fe500 , (UNLESS SPECIFIED) 4kN/sq.m.
COVER = 40mm COVER = 30mm COVER = 40mm COVER = 30mm
# STRATA SHOULD BE CONFIRMED AS PER SOIL
INVESTIGATION REPORT.
230 230
230 230 # 100 LIGHT WEIGHT BLOCK WORK MUST BE USED
250
WITH MAX.
REINFORCEMENT
DENSITY NOT MORE THAN 700KG/CU.M OR
ARRANGMENT 7KN/CUM
H H
600
420
920
920
920
ARRANGMENT ARRANGMENT ARRANGMENT ISSUED FOR
INFORMATION APPROVAL
250
ENQUIRY ORDER
CONSTRUCTION REVIEW
SIGN. OF AUTHORITIES
LONGITUDINAL LONGITUDINAL LONGITUDINAL LONGITUDINAL
REINFORCEMENT 8N-Ø16 + 4N-Ø12 + 6N-Ø10 REINFORCEMENT 4N-Ø16 + 6N-Ø12 REINFORCEMENT 8N-Ø16 + 8N-Ø12 REINFORCEMENT 4N-Ø16 + 12N-Ø12
BOUNDARY ELEMENT MID ZONE MID ZONE MID ZONE MID ZONE
G DATED DATED G
MAIN OTHER MAIN OTHER MAIN OTHER MAIN OTHER MAIN OTHER CLIENT CONTRACTOR
Architectural Revision
SIXTH FLOOR TO SIXTH FLOOR ROOF LEVEL SIXTH FLOOR TO SIXTH FLOOR ROOF LEVEL
E
SIZE OF COLUMN 230 x 1850 SIZE OF COLUMN 230 x 920
(b * l) (b * l)
D
M25 : Fe500 , 230 M25 : Fe500 ,
COVER = 40mm COVER = 40mm NOTE :-
This drawing is the property of
450
230
and shall not be
250
issued.
1850
D
950
Architect Structural
250
Client :-
LONGITUDINAL Mr. RAJENDRA BAGAL
REINFORCEMENT 4N-Ø20 + 8N-Ø16 + 6N-Ø10
Project :-
LONGITUDINAL
REINFORCEMENT BOUNDARY ELEMENT MID ZONE
20N-Ø16 + 12N-Ø12 PROPOSED RESIDENTIAL BUILDING
ARCHITECTURAL CONSULTANT :-
HIERARCHY A
A COLUMN MARK C24, C25
STRUCTURES
1225 'E' WARD, FLAT NO: C-101, NAGESHKAR HEIGHTS
APT., RAJARAMPURI 2nd LANE, KOLHAPUR - 416 008
E-mail : [email protected]
16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1