A-Dec EA-51LT Operations Manual
A-Dec EA-51LT Operations Manual
Trademarks
A-dec logo, A-dec 500, Cascade, Cascade Master Series, Century Plus,
Continental Decade, Performer, Preference, Preference Collection, and
Radius are registered trademarks in the U.S. Patent and Trademarks office.
A-dec, and ICX are also trademarks of A-dec Inc.
CONTENTS
Introduction ................................................................................................... 1
A-dec EA-51LT Electric Motor Features ............................................. 1
Operating Instructions ................................................................................. 2
Safety Notes Before You Begin............................................................. 2
Assembly ................................................................................................. 3
Program and Use.................................................................................... 3
Maintenance................................................................................................... 9
Disinfect and Sterilize ............................................................................ 9
Replace the O-rings .............................................................................. 10
Remove and Replace the Bulb ............................................................ 11
List of Figures
Figure 1 A-dec EA-51LT Electric Motor .................................................... 1
Figure 2 Align Motor Connection Tubes and Tubing
Connection Openings................................................................................... 3
Figure 3 Operator Status.............................................................................. 4
Figure 4 Program Handpiece Standard Mode Settings .......................... 5
Figure 5 Forward/Reverse Button ............................................................. 5
Figure 6 Endodontics Mode Touchpad Screen ........................................ 6
Figure 7 Change the O-ring on the Motor Tubing Terminal................ 10
Figure 8 Replace O-rings on the Motor ................................................... 10
Figure 9 Replace Motor Bulb..................................................................... 11
List of Tables
Table 1 Symbols ..........................................................................................iv
Table 2 Classification of Equipment ........................................................iv
Table 3 Environmental Specifications .....................................................iv
Table 4 Electric Motor, Air and Water Coolant Presets
(Standard Mode) ........................................................................................... 4
Table 5 Endodontics Mode Settings ......................................................... 7
Identification of Symbols
Symbol Description
Recognized by Underwriters Laboratories Inc. with respect to electric shock, fire and mechanical hazards
only in accordance with UL 60601-1 (2601-1) and under mutual recognition agreement with CAN/CSA C22.2,
No. 601.1.
Classified by Underwriters Laboratories Inc. with respect to electric shock, fire and mechanical hazards only
in accordance with UL 60601-1 (2601-1) and under mutual recognition agreement with CAN/CSA C22.2,
No. 601.1.
UL listed to UL 61010A-1, BS EN 61010-2-010 and Canadian (CAN/CSA C22.2, No. 1010.1-92) safety standards.
Attention, consult accompanying documents. No user serviceable parts. Attention, line voltage. Only licensed
electrician should remove cover.
Class II equipment.
Caution: Metal surfaces can be hot during and following the dry cycle.
Flammable Gasses: Not suitable for use in the presence of a flammable anesthetic mixture with air, oxygen, or nitrous
oxide, where such gasses may accumulate in concentration (closed space).
Electrical Rating
Type Specification
Volts: 100/110-120/220-240 VAC
Frequency: 50-60 Hz
Current: As configured and specified in equipment manual (products labeled 15A or greater
require dedicated circuit, identified in distribution panel).
Environmental Specifications
Temperature/Humidity Specification
Storage/Transportation Temperature: -40°C to 70°C (-40°F to 158°F)
Relative humidity: 80% for up to 31°C, decreasing linearly to 50% at 40°C
Indoor Use: Altitude up to 2,000M (6,563 ft.), installation category II, pollution degree 2.
(UL 61010A-1 and CAN/CSA C22.2, No. 1010.1-92 only)
Warranty
A-dec warrants all products against defects in materials or
workmanship for one year from time of delivery. A-dec’s sole
obligation under the warranty is to provide parts for the repair, or at
its option, to provide the replacement product (excluding labor). The
buyer shall have no other remedy. All special, incidental, and
coincidental damages are excluded.
A-dec warrants A-dec dental chair cylinders, both lift and tilt for ten
years from the date of purchase of the chair or the cylinder. This
warranty is retroactive to A-dec chair cylinders already in the field.
The warranty covers chair cylinders A-dec finds to have
manufacturing irregularities. Stool cylinders are covered under
A-dec’s one-year warranty.
Before using the EA-51LT Electric Motor, make note of all cautions
and warnings. Read the component descriptions, and become familiar
with the locations of features and controls.
• Feature descriptions
• Operation
• Adjustments
• Maintenance tasks
Intended Audience
This guide is intended for doctors and dental staff.
• Programmable speed and torque settings for ease of use and safety
• Auto-sensing with auto-forward, auto-stop and auto-reverse
• Up to 8 memory presets per handpiece position
• Separate A and B presets for two different operators
• Single-button push between endodontics and standard modes for
efficiency
Operating Instructions
This section describes how to operate the A-dec EA-51LT Electric
Motor:
Assembly
The EA-51 LT motor and handpiece easily assemble. To assemble:
NOTE If the motor fails to connect, remove it from the tubing. Push the
tubing nut back to the stop, then repeat Steps 1 and 2.
3. Check that the motor has engaged the tubing securely. The motor
and tubing should not separate with a gentle pull.
1. Push the handpiece onto the motor. If the handpiece is fiber optic,
be sure to correctly align the notch.
2. Check for a secure hold on the motor. The handpiece should not
come off with a gentle pull.
Standard Mode
Activate the electric motor by withdrawing the handpiece from the
holder. The settings that appear are the ones last used for that
handpiece position.
Table 4 Electric Motor, Air and Water Coolant Presets (Standard Mode)
1. Press the minus (-) and plus (+) buttons to adjust the RPM. The
RPM values appear in the display screen (see Figure 4).
2. If desired, use the toggle buttons on the touchpad to change air
and water settings.
3. To place the setting into memory (optional), press the Program
button, then press the memory button you want to set. Three
beeps confirm the setting.
A
D
K
L E
F F
H
G
(A) Memory Setting Indicator; (B) Water Coolant Button; (C) Air Coolant Button;
(D) Speed Limit Setting; (E) Forward/Reverse Indicator; (F) Memory Button;
(G) Forward/Reverse Toggle Button; (H) Program Button; (J) Use - and + Buttons to
Adjust Speed; (K) Water Coolant Indicator; (L) Air Coolant Indicator
NOTE You can also use the foot control as a forward/reverse toggle.
When the motor has stopped, tap the accessory (chip/air) button to change
the direction.
Endodontics Mode
In addition to handpiece speed adjustments, the endodontics mode
allows you to change a number of settings based on the specific file
and desired handpiece behavior. Icons in the touchpad window reflect
the settings (see Figure 6).
B
H
J
C
L
K
D
N
M
E
O
F
P
(A) Memory Setting Indicator; (B) Water Coolant Indicator; (C) Air Coolant Indicator;
(D) Operator Mode Indicator; (E) Memory Button; (F) Endodontics Mode Toggle
Button; (G) File Speed Limit; (H) Warning Beep Indicator; (J) Endodontics Light
Indicator; (K) File Torque Unit Indicator; (L) File Torque Limit;
(M) Forward/Reverse Indicator; (N) Handpiece Ratio Setting; (O) Torque Mode
Indicator; (P) Forward/Reverse Toggle Button
Table 5 lists and defines the touchpad window icons for Endodontics
mode:
Maintenance
This section contains information to:
1. Hold the new bulb firmly in the pliers with the flat side facing the
motor and the dot facing out.
2. Insert the bulb into the bulb holder and push into place with the
pliers handle.
3. Replace the motor sheath.
M
B maintenance
bulb replacement, 11 disinfecting and sterilization, 9
C O
changing settings operating instructions, 2
endodontics mode, 6 O-ring replacement
standrd mode, 5 Motor, 10
cleaning motor, 9 Motor tubing terminal, 10
D P
disinfecting motor, 9 programming
handpiece settings in
Endodontics Mode, 6
E handpiece settings in
EA-51LT Electric Motor Standard Mode, 5
bulb removal, 11 touchpad in standard mode, 4
bulb replacement, 11
factory preset speeds, 4
features of, 1 S
maintenance of, 9 safety notes, 2
operating instructions, 2 speeds, factory presets, 4
o-ring, replacement of, 10 standard mode
endodontics mode, 6 handpiece settings, 5
handpiece settings in, 6 usage in, 4
settings defined, 7 sterilizing motor, 9
F T
factory preset speeds, 4 touchpad
features of A-dec EA-51LT electric programming of
motor, 1 endodontics mode, 6
standard mode, 4
A-dec Inc. A-dec International Inc. A-dec United Kingdom A-dec Australia
2601 Crestview Drive 2601 Crestview Drive Austin House, 11 Liberty Way 41-43 Bowden Street
Newberg, OR 97132 USA Newberg, OR 97132 USA Nuneaton, Warwickshire CV11 6RZ Alexandria NSW 2015
Tel: 1.800.547.1883 Tel: 1.503.538.9471 England Australia
in U.S. & Canada www.a-dec.biz Tel: 0800 ADECUK (233285) within UK Tel: 61 (0)2 9699 4600
Tel: 1.503.538.7478 www.a-dec.com Tel: 44 24 7635 0901 outside UK www.a-dec.com.au
outside U.S. & Canada www.a-dec.co.uk
www.a-dec.biz
www.a-dec.com