Secured Power Transmission With Loss and Theft Analysis

The aim of the project work is to monitor the load dispatched at the substation Vs total power consumption by all the users. Once if the above things are equal, the system is ok. If not, we have to find out where the loss or theft occurred. In this project work, for the demonstration purpose a small step-down transformer of 12V, 1 amps rating at secondary is considered and small bulbs are connected as a load.

Uploaded by

Girish Divya
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
268 views6 pages

Secured Power Transmission With Loss and Theft Analysis

The aim of the project work is to monitor the load dispatched at the substation Vs total power consumption by all the users. Once if the above things are equal, the system is ok. If not, we have to find out where the loss or theft occurred. In this project work, for the demonstration purpose a small step-down transformer of 12V, 1 amps rating at secondary is considered and small bulbs are connected as a load.

Uploaded by

Girish Divya
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
You are on page 1/ 6

SECURED POWER TRANSMISSION WITH LOSS ANALYSIS

Head office: 2nd floor, Solitaire plaza, beside Image Hospital, Ameerpet, Hyderabad
www.kresttechnology.com, E-Mail: [email protected] , Ph: 9885112363 / 040 44433434

AIM:
The aim of the project work is to monitor the load dispatched at the substation Vs total power consumption by all the users. Once if the above things are equal, the system is ok. If not, we have to find out where the loss or theft occurred.

PURPOSE:
The purpose of the project is to improve utilization of power for the existing system to save cost and to avoid the loss of source power.

BLOCK DIAGRAM: CONTROL SECTION:

Power supply

ZIGBEE TRANSCEIVER

PC

MAX 232

MICRO CONTROLLER

Head office: 2nd floor, Solitaire plaza, beside Image Hospital, Ameerpet, Hyderabad
www.kresttechnology.com, E-Mail: [email protected] , Ph: 9885112363 / 040 44433434

SUBSTATION SECTION:

POWER SUPPLY

LCD

GPS

MAX 232 ZIGBEE TRANSCEIVER

CURRENT SENSORS MICRO CONTROLLER

A VOLTAGE SENSORS D C

RELAYS

LOADS

POWER SUPPLY:

Step Down Transformer

Bridge Rectifier

Filter Circuit

Regulator section

Head office: 2nd floor, Solitaire plaza, beside Image Hospital, Ameerpet, Hyderabad
www.kresttechnology.com, E-Mail: [email protected] , Ph: 9885112363 / 040 44433434

DESCRIPTION: In this project a ZIGBEE communication system was developed in such a way that it will monitor the load of the substation continuously and that information is transferred to the control room. This system is based on a low-cost electronic device that can acquire and preprocess current & voltages and transmit processed key-information related to the load operation conditions. Information about operating parameters of loads can be sent to a central processing unit allowing knowledge of key-information of the load. In this project work, for the demonstration purpose a small step-down transformer of 12V, 1 amps rating at secondary is considered and small bulbs are connected as a load. In this project we are using current and voltage sensors for measuring load current and voltage respectively. All these parameters are converted into digital value by using ADC. If the parameters of the loads exceed the threshold value or any loss or theft occurred then immediately the relays at the substation get tripped automatically and the location of fault area will be displayed on LCD & PC. This location can be finding using GPS. About all the parameters of load values are continuously transmitted to control section using Zigbee communication. With the help of this kind of system, the maintenance staff of the department can have a continuous vigilance over the transformer.

HARDWARE COMPONENTS:

Microcontrollers Power supplies Relays Loads

Head office: 2nd floor, Solitaire plaza, beside Image Hospital, Ameerpet, Hyderabad
www.kresttechnology.com, E-Mail: [email protected] , Ph: 9885112363 / 040 44433434

ADC LCDs Zigbee Transceivers Current Sensors Voltage sensors GPS MAX 232 PC

SOFTWARE TOOLS:
Keil micro vision Embedded C Express PCB

APPLICATIONS: This project is used for protecting Transformers in sub stations, generating stations etc. Used for Industrial protection

RESULT: Hence, by implementing this project we can monitor the different parameters of loads using ZIGBEE Technology.

Head office: 2nd floor, Solitaire plaza, beside Image Hospital, Ameerpet, Hyderabad
www.kresttechnology.com, E-Mail: [email protected] , Ph: 9885112363 / 040 44433434

Head office: 2nd floor, Solitaire plaza, beside Image Hospital, Ameerpet, Hyderabad
www.kresttechnology.com, E-Mail: [email protected] , Ph: 9885112363 / 040 44433434

You might also like