The XM-18D Intelligent Hatch Controller is an automatic multi-function incubator that utilizes microcomputer technology for precise temperature and humidity control, making it ideal for poultry and rare bird propagation. It features adjustable settings for temperature, humidity, and egg-turning intervals, with a user-friendly interface for easy operation. The device is designed for reliability and efficiency, with factory settings that can be restored if needed.

Uploaded by

alvaro santos
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
117 views8 pages

Owner Manual

The XM-18D Intelligent Hatch Controller is an automatic multi-function incubator that utilizes microcomputer technology for precise temperature and humidity control, making it ideal for poultry and rare bird propagation. It features adjustable settings for temperature, humidity, and egg-turning intervals, with a user-friendly interface for easy operation. The device is designed for reliability and efficiency, with factory settings that can be restored if needed.

Uploaded by

alvaro santos
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 8

Intelligent Hatch Controller

XM-18D

Operation Instruction
The automatic multi-function incubator researched and produced by our
company uses the more popular microcomputer-based technology (using
the latest micro-electronics technology and new components), equiping
with the imported digital temperature sensor and France moisture
sensitive capacitance humidity sensor, which makes this instrument
miniaturization, intelligent, high measurement accuracy. This incubator is
stable and reliable, time-saving, labor-saving, and easy-to-use. It is the
ideal incubation equipment for propagation of poultry and rare birds and
small and medium-sized hatchery.

一、Main Technical Index:


1.Temperature Measuring Range: 0-99℃
2.Temperature Measurement Accuracy: ±0.1℃
3.Humidity Measurement Range: 0—99%RH
4.Humidity Accuracy: ±3%RH
5.Number of signal-output: 7, (over-temperature, temperature control,
insufficient temperature, egg left-turning, egg right-turning, humidity
control, alarm)
6.The maximum output load current: temperature control, insufficient
temperature ≤ 8A/AC220V, over-temperature, egg left-turning, egg
right-turning, humidity control, alarm ≤ 1A / AC22
7.Number of egg-turning: the maximum record is 999 times.
8.cycle of egg-turning: adjustment of 0 – 999 minutes (the factory
default is 90 minutes)
9.egg-turning time: adjustment from 0 to 999 seconds (the factory default
is 180 seconds)
10.ventilation cycle: from 0 to 999 minutes
(the factory default is 120 minutes)
11.ventilation time: from 0 to 999 seconds (the factory default is 30
seconds)
12.Temperature measurement length: About 2 meters
二、Working Condition:
1.Working Voltage: AC 160V - 240V,50HZ
2.Relative Humidity: less than 85% RH
3.Environment Temperature: -10℃ - 60℃
三、Temperature and humidity settings instance: This method is very
simple, as long as you set up both points of temperature and humidity,
others will generate automatically. For example, a incubation control
room needs that the temperature is 38 ℃, humidity is 60% RH.

1
During normal working, press SET and lift your hand, a row of led
will display on the lower side of the controller. * * * t t
If you need to change the temperature value,
press to adjust, till to display the temperature 38 ℃ you
required. And then pressOK and raise your hand,
the led will display on the lower side of the * * * H H
controller. If you need to change the humidity
value, please press to adjust untill the required humidity
60% RH shows. And then press the keyOK, the controller will
automatically calculate and fill the parameters of temperature and
humidity, and finally return to normal working state.
四 、 Arbitrary temperature and humidity settings example
(which may change and automatically generate interval, but
generally do not use it)
During normal operation, press the key SET and don’t raise your

hand, and then press the key untill display


— — — P 1 and then raise your hand, set up the following
— — —
parameters:
 Set up over-temperature alarm: led display * * * P 1
as shown in right figure: “P1” is the over-temperature alarm value,
the alarm will be given if the temperature reaches this value. If any
change is needed, please press untill it displays the value
you required. And press OK and then raise your hand to save data,
and automatically move into the next parameter setting.
 Set up over-temperature value: led display * * * P 2
as shown in right figure: “P2” is the over-temperature value, the
exhaust fan will be started up when the temperature reaches this
value. If any change is needed, please press untill it
displays the value you required. And press OK and then raise your
hand to save data, and automatically move into the next parameter
setting.
 Set up upper limit value of temperature * * * P 3

2
control: led display as shown in right figure: “P3” is the upper
limit of temperature control. The heating will stop when the
temperature reaches this value. If any change is needed, please
press untill it displays the value you required. And press
OK and then raise your hand to save data, and automatically move
into the next parameter setting.
 Set up lower limit value of temperature * * * P 4
control: led display as shown in right figure: “P4” is the lower
limit of temperature control. The heating will start up when the
temperature droppes to this value. If any change is needed, please
press untill it displays the value you required. And press
OK and then raise your hand to save data, and automatically move
into the next parameter setting.
 Set up low temperature value: led display as * * * P 5
shown in right figure: “P5” is the low temperature value. The
standby heating will start up when the temperature droppes to this
value. If any change is needed, please press untill it
displays the value you required. And press OK and then raise your
hand to save data, and automatically move into the next parameter
setting.
 Set up insufficient-temperature alarm value: * * * P 6
led display as shown in right figure: “P6” is the
insufficient-temperature alarm value. The alarm will be given if the
temperature droppes to this value. If any change is needed, please
press untill it displays the value you required. And press
OK and then raise your hand to save data, and automatically move
into the next parameter setting.
 Set up over-humidity alarm: led display as * * * P 7
shown in right figure: “P7” is the over-humidity alarm value. The
alarm will be given if the humidity reaches this value. If any
change is needed, please press untill it displays the value
you required. And press OK and then raise your hand to save data,
and automatically move into the next parameter setting.
 Set up upper limit value of humidity control: * * * P 8

3
led display as shown in right figure: “P8” is the upper limit value
of humidity control. The humidification will stop when the
humidity reaches this value. If any change is needed, please press
untill it displays the value you required. And press OK and
then raise your hand to save data, and automatically move into the
next parameter setting.
 Set up lower limit value of humidity control: * * * P 9
led display as shown in right figure: “P9” is the lower limit of
humidity control. The humidification will start when the humidity
droppes to this value. If any change is needed, please press
untill it displays the value you required. And press OK and then
raise your hand to save data, and automatically move into the next
parameter setting.
 Set up low humidity alarm value: led * * * P P
display as shown in right figure: “PP” is the low humidity alarm.
The alarm will be given if the humidity droppes to this value. If
any change is needed, please press untill it displays the
value you required. And press OK and then raise your hand to save
data, and automatically move into the next parameter setting.
五、Egg-turning and calibration parameter setting
During normal operation, press the key SET and don’t raise
— — — F 1
your hand, and then press the key till display — — —

and then raise your hand, set up the following parameters:

Set up egg-turning — — — F 1 * * * F 1
— — —
interval: as shown: "F1" is two successive egg-turning interval

(unit: minute), if any change is nedded, please press

untill it displays the value you required. And press OK and then

lift your hand to save data, and automatically move to the next

parameter setting.
 Set up egg-turning time: led display as * * * F 2
shown in right figure: "F2" is the egg-turning time (unit: second),

4
which represents the time of turning eggs, if any change is
necessary, please press untill it displays the number you
required. And press OK and then lift your hand to save data, and
automatically move to the next parameter setting.
 Set up ventilation interval: led display as * * * F 3
shown in right figure: “F3” is the ventilation interval time (unit:
second), if any change is needed, please press untill it
displays the value you required. And press OK and then raise your
hand to save data, and automatically move into the next parameter
setting.
 Set up ventilation time: led display as shown * * * F 4
in right figure: “F4” is the ventilation time (unit: second), if any
change is needed, please press untill it displays the value
you required. And press OK and then raise your hand to save data,
and automatically move into the next parameter setting.
 Set up temperature calibration: led * * * F 5
display as shown in right figure: “F5” is the temperature
calibration value, this parameter may revise the temperature
deviation brought about by improper selection of temperature
measuring point. If any change is needed, please press
untill it displays the value you required. And press OK and then
raise your hand to save data, and automatically move into the next
parameter setting.
 Set up humidity calibration: led display as * * * F 6
shown in right figure: “F6” is the humidity calibration, this
parameter may amend the humidity deviation caused by improper
selection of humidity measuring point. If any change is needed,
please press untill it displays the value you required. And
press OK and then raise your hand to save data, and automatically
move into the next parameter setting.
☆ Number of egg-turning: led display as * * * F 7
shown in right figure: “F7” is the number of egg-turning, press the
key OK and then raise your hand to return to the normal working
state.
六、Egg-turning and Silencing Description

5
 Egg-turning Mode:
Automatic egg-turning:
Turn eggs automatically in accordance with the set egg-turning
interval and egg-turing time, turn left → interval → turn right
→interval → turn left ... ... alternation of egg-turning. The number
of egg-turning will display on the parameter F7, and will be zero if
the controller power is cut off. In order to ensure normal
egg-turing, please switch to the state of automatic egg-turing.
Manual egg-turning:
Press the key and do not lift your hand, the controller will
enter into the state of manual egg-turing after2 seconds. You're
your hand when it is adjusted to the desired location, the controller
will get into the state of automatic egg-turing.
The computer wil define automatically the direction of
egg-turning.
 Silencing function: when the controller give an alarm, press the
key and lift your hand, to remove the buzzer sound and alarm
output, but then the alarm indicator lamp still lights up; press the
key again and raise your hand, to restore buzzer sound and
alarm output control.
七、Restore Factory Settings
Press both keys of at the same time for more than three

seconds, the controller will display zero. Raise hand immediately

after hearing “Di” from the buzzer, the controller will automatically

restore the factory settings.


Factory Settings:
Reference temperature: 38.0 ℃; reference humidity: 60% RH;
cycle of egg-turning: 90-minute; time of egg-turning: 180 seconds;
ventilation cycle: 120 minutes; ventilation time: 30 seconds;
egg-turning state: automatic egg-turning

6
八、Controller Wiring Diagram:

Welcome to use our automatic incubator by computer!


Please pay attention to the following aspects in use:
1. The micro-computer controller has been made adjustment for
temperature, humidity, egg-turing, exhaust, etc. before leaving
factory, which meets settings required by incubation. Under
normal circumstances, you do not need to set up and may use it by
connecting the power supply. Factory settings: temperature 38 ℃,
humidity 60% RH; cycle of egg-turning: 90-minute, time of
egg-turning: 180 seconds; ventilation cycle: 120 minutes;
ventilation time: 30 seconds; egg-turning state: automatic
egg-turning.
2. If you need only to change the temperature and humidity
parameters, please refer to Section III in page 2 of this Manual.
Please do not set up other parameters in order to avoid operation
errors which may affect your usage and bring you f unnecessary
losses.
3. Temperature and humidity sensors are made of high precise and
micro-molecular materials, please do not make the sensor come
into contact with the water directly. The dust must be regularly
cleared on the surface of the sensor, or it will affect the
measurement accuracy.
4. The manufacturer should only assume the obligation for products
selled to users, but not undertake users’ other losses caused by
product failure.