Pedrollo 3 4 CP
Pedrollo 3 4 CP
3CPm 80
PERFORMANCE RANGE These pumps should be installed in a covered area, protected against
weather.
Flow rate up to 110 l/min (6.6 m3/h)
Dynamic head up to 50 m WARRANTY: 2 YEARS
(according to our general sales conditions).
OPERATING LIMITS
Suction lift up to 7 m STRUCTURAL CHARACTERISTICS
Fluid temperature up to + 40°C ● PUMP BODY:
Maximum ambient temperature + 40°C cast iron, with UNI ISO 228/1 gas threaded suction and delivery
openings.
● PUMP BODY COVER:
AISI 304 stainless steel serving also as mechanical seal housing.
● IMPELLERS:
CONSTRUCTION AND SAFETY STANDARDS: centrifugal radial flow type, made of "General Electric" Noryl®
technopolymer (approved for drinking water).
EN 60 335-1 EN 60034-1 ● MOTOR SHAFT:
IEC 335-1 IEC 34-1 AISI 416 stainless steel (AISI 430F for 4CP100).
CEI 61-150 CEI 2-3 ● MECHANICAL SEAL:
ceramic and graphite.
● MOTOR:
the pumps are coupled to an asynchronous, high efficiency PEDROLLO
induction motor of suitable size, which is quiet, closed and externally
ventilated, suitable for continuous duty. INSULATION class B.
PUMP INSTALLATION AND APPLICATIONS The thermal cutout relay (motor protector) is incorporated in
single phase motors.
These pumps are suitable for pumping clean water and fluids which are not Three phase motors require an adequate external motor protector, with
chemically aggressive to the pump components. connections according to current standards.
THEY ARE EXTREMELY RELIABLE, SIMPLE TO USE, QUIET AND ● PROTECTION:
VIRTUALLY MAINTENANCE-FREE, FINDING MANY USES IN
IP 44.
DOMESTIC APPLICATIONS, IN PARTICULAR THE AUTOMATIC
● REGISTERED MODEL nº VR9705.
DISTRIBUTION OF WATER FROM SMALL AND MEDIUM-SIZED SURGE
TANKS, FOR WATERING GARDENS, ETC.
30
PERFORMANCE CHART AT n= 2900 1/min
0 5 10 15 20 25 US g.p.m.
0 5 10 15 20 Imp. g.p.m.
55 feet
50
4CP80
150
45
4CP100
40
Total dynamic head H (m)
3CP80
35
3CP100
30 100
2CP80
25
20
15 50
10
0 0
0 10 20 30 40 50 60 70 80 90 100 110 l/min
0 1 2 3 4 5 6 m3/h
Flow rate Q
PERFORMANCE DATA AT n= 2900 1/min
Q 0 0.3 0.6 0.9 1.2 1.5 1.8 2.4 3.0 3.6 4.2 4.8 5.4 6.0 6.6
PUMP MODEL POWER m3/h
Single phase Three phase kW HP l/min 0 5 10 15 20 25 30 40 50 60 70 80 90 100 110
DIMENSIONS
PUMP MODEL DN1 DN2 DIMENSIONS mm
Single phase Three phase a f h h1 h2 n n1 w s
2-3CPm 80 2-3CP 80 1" 1" 102 323 175 134 41 148 116 12 9
4CPm 80 ––– 1" 1" 127 331 175 134 41 148 116 12 9
––– 4CP 80 1" 1" 127 323 175 134 41 148 116 12 9
3CPm 100 ––– 1" 1" 102 331 175 134 41 148 116 12 9
––– 3CP 100 1" 1" 102 323 175 134 41 148 116 12 9
4CPm 100 4CP 100 1" 1" 127 370 190 134 41 148 116 12 9
31