Display Screens
Viewing and Clearing
Alarm Codes
µP-T
1. Press the ON key to
turn the unit ON.
1. Press the ON key to
turn the unit ON.
Remote
2. Press the SELECT key
repeatedly to show the
prompt and display
2. If the ALARM icon is
present, one or more
alarms have been
Control
screens.
The prompt and display screens will appear in the order shown
below:
detected.
To View Alarm Codes
1. Press the SELECT key to show the Alarm display screen.
Operating
[ALr] Alarm codes if present. If no codes exist this
screen will not appear.
[CYCLS] CYCLE SENTRY or Continuous mode
If more than one alarm code exists, each will be displayed for
several seconds. The alarm code shown here is alarm code 66-
Low Engine Oil Level.
Guide
prompt screen. [YES] - CYCLE SENTRY; To Clear Alarm Codes
[no] = Continuous
1. Correct the cause of the alarm code.
[dIS]* Discharge air temperature as measured by
2. Press the SELECT key to display the alarm code.
the discharge temperature sensor.
3. Press the ENTER key to clear the alarm code.
[coL]* Evaporator coil temperate as measured by
If more than one alarm code is present, the ENTER key must
the evaporator coil temperature sensor.
be pressed to clear each alarm code individually.
[tLH] Total amount of time in hours the unit has been
turned ON with the keypad On key (if enabled).
Consult the operating manual for your Thermo King unit to view
[EnH] Total amount of time in hours the diesel
the complete list of possible alarm codes and their definitions.
engine has run.
Consult unit operating, maintenance and parts manuals for
[ELH] Total amount of time in hours the electric
additional information on unit operation and maintenance.
motor has run (on units equipped with
Electric Standby).
[Hr4] Total accumulated hours on hourmeter 4 CAUTION: This is a quick reference guide. Keypad/Display Descriptions
(if enabled). Always refer to the operating manual for detailed
[Hr5] Total accumulated hours on hourmeter 5 instructions. Selecting CYCLE-SENTRY or Continuous Mode
(if enabled).
[Hr6] Total accumulated hours on hourmeter 6 Starting the Engine
The µP-T Microprocessor is used on:
(if enabled). • KD-II Smart Reefer Truck units
[oIL]* Diesel engine oil pressure. Initiating a Manual Defrost Cycle
• RD-II Smart Reefer Truck units
[Ent]* Diesel engine coolant temperature. • TD-II Smart Reefer Truck units
[rPn]* Diesel engine RPM. Viewing Prompt and Display Screens
• MD Smart Reefer Truck units
[bAt]* Battery voltage of the unit battery. • TS Smart Reefer Truck units
[bLIt] Backlight select (allows the driver to select Viewing and Clearing Alarm Codes
high or low backlight illumination level).
[dFI] Initial defrost interval.
[ddr] Defrost duration.
*Each prompt or display screen will remain on the display for
about 10 seconds. If no other key is pressed, the display will
then return to the Standard Display of box temperature and
setpoint. TK 50772 - PC Rev 1, 04-08 © Thermo King Corporation
µP-T Remote Control Features Selecting CYCLE-SENTRY or
Continuous Mode
1 2 3 4 5 10, 11 12 13