The MP100(S)-1 generator, powered by a Perkins 1104C-44TAG2 engine, offers a rated power of 100 kVA for prime use and 110 kVA for standby. It features a digital control system, operates at a frequency of 50 Hz, and is designed for environmental conditions with ambient temperatures between +5°C and +40°C. The generator includes various specifications for fuel consumption, dimensions, and alternator features, along with options for customization and additional equipment.

Uploaded by

muhamadakkawi
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
29 views3 pages

MP100(S)-1(1104C-44TAG2)specification

The MP100(S)-1 generator, powered by a Perkins 1104C-44TAG2 engine, offers a rated power of 100 kVA for prime use and 110 kVA for standby. It features a digital control system, operates at a frequency of 50 Hz, and is designed for environmental conditions with ambient temperatures between +5°C and +40°C. The generator includes various specifications for fuel consumption, dimensions, and alternator features, along with options for customization and additional equipment.

Uploaded by

muhamadakkawi
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

Model: MP100(S)-1

Powered by Perkins

Applicable Standards
 ISO 8528-5:2018
 GB/T2820.5-2009
 CE

General Information Prime power Standby power


Rated Power (kVA) 100 110
Environmental Conditions
Power Rating (kW) 80 88
 Ambient temperature: +5°C~+40°C
Frequency (Hz) 50  Altitude: ≤1000m
Engine Model 1104C-44TAG2 Remark: If your conditions are different
from the above, please contact our
Engine Speed (RPM) 1500 sales.
Phase 3
PF 0.8
Control System Digital Factory Inspection
 Complete design and quality inspection
400/230
Rated voltage (V)  0%, 25%, 50%, 75%, 100%, 110% load
(According to customer requirements) test.
Fuel tank capacity operating time ≥ 8h @ 75% load  Function test.
 Protection test
110% load 24.9

Fuel Consumption 100% load 22.6


(L/h) 75% load 17.1
Painting Process
50% load 11.8
 MPMC has the most advanced
automatic spraying / powder coating
production line, and is equipped with
various sandblasting equipment to
ensure higher quality.
 Canopy painting: Henkel pretreatment
process and world famous brand
AkzoNobel powder.
 Base Frame painting: Sandblasting
process and AkzoNobel powder
(Hempel paint is optional).
Dimension and Weight
MP100-1 MP100S-1
Model
Open type Silent type
Length (L) mm 2375 2800
Width (W) mm 750 1130
Height (H) mm 1500 1580
Dry weight (kg) 1250 1720
Tank capacity (L) 180 280
The loading capacity (40'HC) 15 units 8 units
Note: Specifications and illustrations are subject to revision without notice.

www.mpmc-china.com
Engine Specifications
Engine model & manufacturer 1104C-44TAG2 (Perkins)
Emission Certification -------

Number of cylinders 4

Cylinder arrangement In-line

Cycle Four stroke

Aspiration Turbocharged

Bore x Stroke 105 X 127 mm

Displacement 4.41 L

Compression ration 18.2 :1

Prime power /speed 93.6 kW/1500 rpm

Standby power /speed 103 kW/1500 rpm

Speed governor Electronic

Cooling system Forced Water Cooling Cycle

Frequency droop ≤ 3%

Total lubrication system capacity 8L

Coolant capacity (engine only) 7L

Fuel consumption 100% load 205 g/kW.h @1500 rpm

Starter motor DC 12V

Charge alternator DC 12V


 Heavy duty diesel engine  Starter battery (with lead acid) including rack and cables
 Anti-vibration mount  Flexible fuel connection hoses
 Replaceable fuel filter, oil filter & air filter  Exhaust silencer and bellows
 Cooling radiator and fan  Operation manuals and circuit diagram documents

Alternator Specifications
Alternator

Number of phase 3

Power factor (Cos Phi) 0.8

Poles 4

Insulation type H class

Winding Pitch 2/3

IP rating IP23

Bearing Single bearing

Voltage regulator A.V.R

Coupling Flexible disc

www.mpmc-china.com
Control Panel
DSE 4520 MKII
Auto start and auto mains failure control module
(Alternator frequency & can speed sensing)
Key benefits
 Ultimate size to feature ratio.
 Automatically transfers between mains (utility) and generator.
 Hours counter provides accurate information for monitoring and
maintenance periods.
 User-friendly set-up and button layout for ease of use.
 Multiple parameters are monitored simultaneously which are
clearly displayed on the largest back-lit icon display in its class.
 The module can be configured to suit a wide range of applications.
 Compatible with a wide range of CAN engines including Tier 4.
 IP65 rating (with optional gasket) offers increased resistance to
water ingress.

Key features
 Auto Start and AMF mode in one module.  4 configurable digital inputs.
 J1939-75 support and CAN alarm ignore function.  Configurable staged loading outputs.
 Alternator frequency & CAN speed sensing in one variant.  3 engine maintenance alarms.
 Largest back-lit icon display in its class.  Engine speed protection.
 Heated display option.  Engine hours counter.
 Real time clock provides accurate event logging.  Engine pre-heat.
 Fully configurable via the fascia or PC using USB communication.  Engine run-time scheduler.
 Extremely efficient power save mode.  Engine idle control for starting & stopping.
 3 phase generator sensing.  Tier 4 engine instrumentation screens.
 3 phase mains (utility) sensing  Battery voltage monitoring.
 Compatible with 600 V ph to ph nominal systems.  Start on low battery voltage.
 Generator/load power monitoring (kW, kVA, kVar, PF).  Configurable remote start input.
 Accumulated power monitoring (kWh, kVAh, kVarh).  1 alternative configuration.
 Generator overload protection.  Comprehensive warning, electrical trip or shutdown protection
 Generator/load current monitoring and protection. upon fault condition.
 Fuel and start outputs (configurable when using CAN).  LCD alarm indication.
 4 configurable DC outputs.  Event log (50)
 3 configurable analogue/digital inputs

Options
Engine Alternator Fuel System Generating Set
□ Deepsea, ComAp, Smartgen
□ Water Jacket Preheater □ PMG excitation □ 12 / 24 hour base tank
etc. controller
□ Oil Preheater □ Space heater □ Bunded fuel tank
□ Oil manual pump □ Winding temperature □ External fuel tank □ Trailer
measuring □ Automatic fuel feeding □ Tools with the machine
□ Switch between external tank
and base tank (three-way valve)
ISSUE 1 @ MPMC CN

Follow us
https://www.facebook.com/mpmcgroup
https://www.linkedin.com/company/mpmcpowertech/
https://www.youtube.com/user/MPMCGenerator
MPMC POWERTECH CORP. All information in this document is substantially correct at time
[email protected] | www.mpmc-china.com of printing and may be altered subsequently. Final weight and
Photographs are for illustrative purposes only and may not reflect final dimensions will depend on completed specification.
specification.

You might also like