Driver Dali LHP1710W - 220-400V - E3 - DALI - CM - 9290 - 028 - 69706

The document provides a comprehensive datasheet for the LHP1710W 220-400V E3 DALI CM LED driver, detailing its electrical input and output specifications, control methods, and operational parameters. It includes information on wiring, insulation, operational temperatures, lifetime, and safety features. Additionally, it outlines installation guidelines, surge immunity, and regulatory compliance for effective integration into lighting systems.

Uploaded by

torka
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
837 views8 pages

Driver Dali LHP1710W - 220-400V - E3 - DALI - CM - 9290 - 028 - 69706

The document provides a comprehensive datasheet for the LHP1710W 220-400V E3 DALI CM LED driver, detailing its electrical input and output specifications, control methods, and operational parameters. It includes information on wiring, insulation, operational temperatures, lifetime, and safety features. Additionally, it outlines installation guidelines, surge immunity, and regulatory compliance for effective integration into lighting systems.

Uploaded by

torka
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 8

LED High Power

Datasheet + application instructions guide

Sport and Stadium drivers


LHP1710W 220-400V E3 DALI CM

9290 028 69706

June 2022
Electrical input data

Specification item Value Unit Condition


Rated input voltage range 207 ... 424 Vac Performance range with reduced output current up to 1.8A
Rated input voltage range 212 ... 424 Vac Performance range with full output current up to 2.0A
Rated input voltage 220/230/380/400 Vac 220Vac: only with reduced output current up to 1.8A
Rated input frequency range 50/60 Hz DC (emergency) input voltage operation not supported
Rated input current 8.0/4.6 A @ rated output power @ rated input voltages
Max. input current 9.0 A @ rated output power @ minimum performance input voltage
Rated input power 1820 W @ rated output power @ rated input voltage
Power factor ≥ 0.9 @ rated output power @ rated input voltage
Total harmonic distortion ≤ 20 % @ rated output power @ rated input voltage
Efficiency typ. 95/96 % @ input voltage 230/400Vac input voltage @ Vout/Iout = 285V/2A

Input voltage AC range 198 ... 440 Vac Safety operational range
Input frequency AC range 45 ... 66 Hz Safety operational range
Standby Power, Psb 0.48 W No-glow mode
Insulation input to output None

Electrical output data

Specification item Value Unit Condition


Regulation method Constant Current 3x output channels
Output voltage 170 ... 285 Vdc 0.1A < output current < 1.2A: Vout range = 170 ... 285V.
1.2A < output current < 2.0A: Vout range= 200 ... 285V
Rated output power 1710 W All three channels running at full power
Output working voltage max. 550 V
Output current 0.1 ... 2 A Per channel incl. dimming
Output current min programmable 1.2 A
Output current tolerance ±5 % +/- 20% including dimming down to 0.1A
Output current ripple LF ≤4 % Ripple = peak / average < 3kHz
Output current ripple HF ≤ 20 % Ripple = peak / average > 3kHz
Output PstLM ≤ 0.03 In entire operating window incl. dimming
Output SVM ≤ 0.002 In entire operating window incl. dimming
Output power 17 ... 570 W Per channel incl. dimming

Electrical data controls input

Specification item Value Unit Condition


Control method Dynadimmer, DALI, SR, Coded Mains Output current ampl. dimming DALI acc. IEC62386 DALI-2 Part 101/102/207/250/251/252/253

Dimming range 1.7...100 % Acc. D4i. See www.digitalilluminationinterface.org/products. See


design-in guide at www.philips.com/oem for controllability details
Isolation controls input to output Reinforced Acc. IEC61347-1

SR output voltage max. 22.5 V

SR guaranteed current 52 mA

SR maximum current 60 mA

Logistical data

Specification item Value


Product name LHP1710W 220-400V E3 DALI CM
Logistic code 12NC 9290 028 69706
Pieces per box 1
Weight (kg, incl. housing) 6.28

2
Wiring & Connections

Specification item Value Unit Condition


Input wire cross-section 1.5 ... 4.0 / 16 ... 11 mm2 / AWG WAGO2624, solid / stranded wire
Input wire strip length 10 ... 12 mm

DALI-SR wire cross-section 1.0 ... 2.5 / 18 ... 14 mm2 / AWG WAGO739, solid / stranded wire
DALI-SR wire strip length 8 ... 9
Output wire cross-section 1.0 ... 2.5 / 18 ... 14 WAGO2624, solid / stranded wire
Output wire strip length 10 ... 12
Maximum LED output cable length 200 m Between driver and luminaire, with 8-wire 8G2.5 cable

Maximum LED output cable length 50 m Between driver and luminaire, with 7-wire 7G2.5 cable

Insulation

Insulation Mains Housing DA/+24V interface LED output + NTC


Mains Basic Reinforced None
Housing Basic Basic Basic
DA/+24V interface Reinforced Basic Reinforced
LED output + NTC None Basic Reinforced

Operational temperatures and humidity

Specification item Value Unit Condition


Ambient temperature -40 ... +45 ºC Higher ambient temperature allowed as long as Tcase-max is
not exceeded.
Tcase-max 75 ºC Maximum temperature measured at Tcase-point
Tcase-life 75 ºC Measured at Tcase-point

Relative humidity 10 ... 90 % Non-condensing

Storage temperature and humidity

Specification item Value Unit Condition


Ambient temperature -40 ... +85 ºC
Relative humidity 5 ... 95 % Non-condensing

Lifetime

Specification item Value Unit Condition


Driver lifetime 50,000 hours Measured temperature at Tcase-point is Tcase-life.
Maximum failures = 5%

Max. mains switching cycles 3 switches Average per day over the specified lifetime

3
Dimensions

Programmable features

Specification item Available Default setting Condition


Set Adjustable Output Current (AOC) Yes 1.2A
LED Module Temperature Protection (MTP) Yes ON Approved NTC type: Murata NCP18XH103F03RB
Driver Temperature Limit (DTL) Yes ON, shutdown disabled
Adjustable Light Output (ALO) Yes OFF
Luminaire Info (DALI part 251) Yes —
Constant Light Output (CLO) Yes OFF
DALI 253 M (DALI part 253) Yes —
Minimum dim level Yes 8.3% 8.3% with default AOC; 5% at max. AOC, 1.7% with low-dimming enabled

Integrated Dynadimmer Yes OFF


SR PSU (DALI part 250) Yes ON
OEM Write Protection (OWP) Yes OFF

Coded Mains Yes OFF

Features

Specification item Value Remark Condition


Open load protection Yes
Short-circuit protection Yes Only between LED+ and LED- ; duration max. 15min
Hot wiring No
Suitable for fixtures with protection class I per IEC60598
Over temperature protection driver Yes Automatic recovering

+24V auxiliary power supply (DALI part 150) Yes


Energy metering (DALI part 252) Yes Accuracy: 4%

Note: software updatable (in background, over DALI; with wireless SR module: OTA update)

Certificates and standards

Specification item Value


Approval marks CE / ENEC / SR / D4i / DALI 2 / Independent / RCM / UKCA / WEEE
IP and IK classification IP66 when fully assembled with cable glands / IK08

4
Inrush current

Specification item Value Unit Condition


Inrush current Ipeak 20/30 A Input voltage 230/400Vac
Inrush current Twidth 200/300 us Input voltage 230/400Vac, measured at 10% Ipeak
Driver is equipped with inrush-limiting feature SoftStart

MCB type Rating Max. recommended number of LED drivers


Any 10A 1/1
Any 13A 1/2
Any 16A 1/2
Any 20A 2/3
Any 25A 2/4
Any 32A 3/5
Any 40A 4/7
Any 50A 5/8
Any 63A 6/11
Max. amount of drivers is based on steady-state input current at
rated input voltage = 230V/400Vac with 20% MCB current
derating.

Driver protective conductor current

Specification item Value Unit Condition


Typical protective conductor current 1.5/1.8 mArms At 230V/400Vac 60Hz acc. IEC61347-1
LED module contribution not included

Surge immunity

Specification item Value Unit Condition


Mains surge immunity (diff. mode) 10 kV L - N acc. IEC61000-4-5, 2 Ohm, 1.2/50us, 8/20us
Mains surge immunity (comm. mode) 10 kV L/N - PE: acc. IEC61000-4-5, 12 Ohm 1.2/50us,8/20us
DA+ - DA-/SGND acc. IEC61000-4-5, 2 Ohm, 1.2/50us, 8/20us
Control surge immunity (diff. mode) 2 kV
+24V - DA+ & DA-/SGND acc. IEC61000-4-5, 42Ohm, 1.2/50us, 8/20us
DA+ & DA-/SGND - PE acc. IEC61000-4-5, 12 Ohm 1.2/50us,8/20us
Control surge immunity (comm. mode) 4 kV
+24V & DA+ & DA-/SGND - PE acc. IEC61000-4-5, 42Ohm, 1.2/50us, 8/20us

Operating window / driver overheating behavior

Note: thermal shutdown by default disabled

5
Power factor versus output power

Efficiency versus output power

THD versus output power

6
Important driver application & design-in warnings and instructions
Multi-channel operation:
- All three output channels share a common LED+ terminal
- Each channel can deliver an output current of 0.1 ... 2.0A (incl. dimming)
- Output channels cannot be connected in series
- Configured output current value (AOC) applies to all three channels simultaneously
- Output loading in Watt of the channels is allowed to be inequal
- Allowed forward voltage range of the connected LED module is dependent on output current (per channel):

a range of 200 ... 285V is supported between 1.2 and 2.0A


a range of 170 ... 285V is supported between 0.1 and 1.2A
- Dual-channel operation is supported: the driver has to be configured accordingly to prevent false partial lamp failure.
- Channel #1 must remain active since the MTP feature is embedded in this channel.

MTP feature:
- In case the MTP feature detects a missing NTC, the LEDs will blink 8 times before normal operation is resumed without thermal LED module derating.
- Approved NTC type: Murata NCP18XH103F03RB.

Output turn-off:
- Since the driver output is not insulated from the mains input, a faint glow can be seen from the LED modules when the driver is turned off via a DALI OFF
command. A driver-internal relay will disconnect the LED modules 90s after the DALI OFF command to eliminate glow.

Fusing information:
This driver is equipped with a SoftStart inrush current limiter. As a consequence, the limit on the number of drivers connected to an MCB/melting fuse is
based on the steady-state input current DVIXQFWLRQRIWKHUDWHGLQSuWYROWDJHs

Servicing:
Immediately after mains power-off, a voltage up to 650V may be present between either output and earth. This voltage will drop below 48V after no more
than 60 seconds. It is recommended to service the driver after this period of time.

Integration:
- The driver shall be integrated :
- In a mast: hooks are provided to hang the driver vertically with cable glands at the bottom side.
- In a cabinet: hooks or screws can be used to fixate the driver vertically with cable glands at the bottom.
- On the bracket of the luminaire: screws and fixing plates are provided to fixate the driver.

Cabling:
Three cables can be connected to the driver through corresponding cable glands to ensure IP66 rating:
− Cable gland for mains entry cable is M25, supporting a cable diameter range of 13 ... 18mm
− Cable gland for DALI cable is M20, supporting a cable diameter range of 6 ... 12mm
− Cable gland for LED cable output is M25, supporting a cable diameter range of 13 ... 18mm
The DALI cable gland is plugged with a blind cover by default. This cover must only be removed once a DALI cable is connected.

Surge immunity:
A bridge wire is by default inserted in two adjacent connector terminals. See the connection diagram at p.3 of this document. This wire must not be removed in
the final application in order to maintain specified driver surge immunity. Temporary removal is allowed during dielectric strength testing of the driver above
600Vac ("hi-pot testing") to prevent a false negative test result. This bridge wire must be reconnected as soon as this test has been finished. Failure to do may
result in premature driver and luminaire failure in the final application.

Use of a D4i/SR sensor with auxiliary 24V input:


- A Zhaga Book 18 receptacle is mounted on the top of the driver housing to enable mounting of a local D4i/SR sensor.
By default, this receptacle is not internally wired to the driver DA SR interface. A separate wiring loom is included as accessory.
The tinned wire ends of the wiring loom are intended to be pressed into the Zhaga connector, The other ends of the wiring
loom are equipped with crimped ferrules, intended to be inserted into the DA+, DA-/SGND and +24V connectors of the driver.

Supported control wiring options:


− Per remote D4i/SR sensor: via a 3-wire cable, connected to the DA SR interface. Max allowed cable length = 30m. Cabling must be running inside the cabinet or
inside the pole.
− Per local D4i/SR sensor and Zhaga receptacle: connected internally by wires to the DA SR interface. Wiring loom is included as accessory, intended to be
assembled by the installer. In that case the DALI cable gland cover must not be removed in order to maintain specified driver IP rating.
− Per remote DALI controller: via a 2-wire long-distance cable connected to the DA SR interface. Max allowed cable length = 300m. Only the use of the DA-/SGND
and DA+ lines are supported excl. the +24V line.
Remark:
The driver supports multiple control options. However, only one option can be used at a time:
− control by an external DALI controller connected via an external cable
− control by an external D4i/SR sensor connected via an external cable
− control by a local D4i/SR sensor mounted on the Zhaga receptacle.

7
Warning: the driver is NOT allowed to be covered with insulation material or
to be in contact with combustible materials. Minimum required clearance
between top and both sides of the driver are listed below:

RCM independent control gear classification

Regulation AS/NZS 60598.2.2 Applies when the control gear is built inside constructions

Clearance type Description Distance

Height clearance to building element Minimum distance between the top of the control 150mm
(HCB) gear and any building element above it

Minimum insulation clearance Minimum distance between the top of the control 150mm
(MIC) gear and the building insulation above it

Side clearance to building element Minimum distance between the side of the control 50mm
(SCB) gear and any building element

Side clearance to insulation Minimum distance between the side of the control 50mm
(SCI) gear and any building insulation

RISK OF FIRE BUILDING INSULATION MUST NOT COVER THE CONTROL GEAR

©2022 Signify Holding, IBRS 10461, 5600 VB, NL. All rights reserved.

The information provided herein is subject to change without notice. Signify does not give any representation or warranty as to the
accuracy or completeness of the information included herein and shall not be liable for any action in reliance thereon. The information
presented in this document is not intended as any commercial offer and does not form part of any quotation or contract, unless otherwise
agreed by Signify.

Philips and the Philips Shield Emblem are registered trademarks of Koninklijke Philips N.V. All other trademarks are owned by Signify
Holding or their respective owners.

Date: June 23, 2022

www.philips.com/oem