structuralsamplecantileverbeam
structuralsamplecantileverbeam
5-16mmØ TOP BARS 2-16mmØ TOP BARS 4-16mmØ TOP BARS 2-16mmØ TOP BARS
4-16mmØ TOP BARS 2-16mmØ TOP BARS 5-16mmØ TOP BARS 5-16mmØ TOP BARS
PROJECT TITLE / LOCATION : CAD BY: PREPARED BY : REVIEWED & SUBMITTED : RECOMMENDED : APPROVED : SHEET CONTENT : SHEET NO.:
TRUSS-2
TRUSS-3
SIDE ELEVATION
TRUSS-3
TRUSS-3
TRUSS-3
TRUSS-1
TRUSS-3
SCHEMATIC DRAWING OF TRUSS
TRUSS-2
PROJECT TITLE / LOCATION : CAD BY: PREPARED BY : REVIEWED & SUBMITTED : RECOMMENDED : APPROVED : SHEET CONTENT : SHEET NO.:
C'
C
EAVES FASCIA DETAIL
SECTION C-C'
STAIR SLAB DETAIL
SECTION SECTION
@ SUPPORT @ MIDSPAN
COUNTER DETAIL
PROJECT TITLE / LOCATION : CAD BY: PREPARED BY : REVIEWED & SUBMITTED : RECOMMENDED : APPROVED : SHEET CONTENT : SHEET NO.:
1
VICINITY MAP
20.1000
SLOPE = 1/1 0
0 SLOPE = 1/1
SANITARY ENGINEER
PRC No. PTR No.
2 3 4
SEPTIC TANK DETAIL CATCH BASIN DETAIL SITE DEVELOPMENT PLAN
PROJECT TITLE / LOCATION : CAD AND DESIGNED BY: CHECKED BY: REVIEWED & SUBMITTED : RECOMMENDED : APPROVED : SHEET CONTENT : SHEET NO.:
3.00
3.00
3.00
3.00
roof slope
8.00
8.00
8.00
8.00
2.35
2.35
2.35
2.35
roof slope
2.65
2.65
2.65
2.65
1 2 SECOND FLOOR SEWER, VENT & STORM 3 4
GROUND FLOOR SEWER, VENT & STORM DRAINAGE LINE LAYOUT PLAN LOWER ROOF VENT & STORM DRAINAGE LINE LAYOUT PLAN UPPER ROOF VENT & STORM DRAINAGE LINE LAYOUT PLAN
DRAINAGE LINE LAYOUT PLAN
NOTE :
13.10 5.60
3.83 3.68 5.60
3.00
3.00
8.00
8.00
2.35
2.35
2.65
2.65
SANITARY ENGINEER
PRC No. PTR No.
5 6 SECOND FLOOR COLD WATER LINE 7 LOWER ROOF VENT & STORM DRAINAGE LINE 8 9
GROUND FLOOR COLD WATER LINE LAYOUT PLAN AIR VENT DETAIL LAVATORY DETAIL
LAYOUT PLAN LAYOUT PLAN
PROJECT TITLE / LOCATION : CAD AND DESIGNED BY: CHECKED BY: REVIEWED & SUBMITTED : RECOMMENDED : APPROVED : SHEET CONTENT : SHEET NO.:
e
slop
of
ro
3 4
CLEAN OUT DETAIL GUTTER DRAIN (DOME TYPE) DETAIL
SANITARY ENGINEER
PRC No. PTR No.
1 7 8
ISOMETRIC PLAN FLOOR DRAIN DETAIL AIR CHAMBER DETAIL
PROJECT TITLE / LOCATION : CAD AND DESIGNED BY: CHECKED BY: REVIEWED & SUBMITTED : RECOMMENDED : APPROVED : SHEET CONTENT : SHEET NO.:
4. ALL WIRE SHALL BE COPPER AND THERMOPLASTIC INSULATED TYPE "THHN" UNLESS
OTHERWISE INDICATED IN THE PLAN. THE MIN. SIZE OF WIRE FOR POWER & LIGHTING
CIRCUIT HOMERUN SHALL BE 3.5mm AND 600 V SMALLEST RACEWAY SHALL BE 20mm Ø
TRADE NOMINAL SIZE
5. ALL OUTLET BOXES SHALL BE PVC GAUGE 16 DEEP TYPE W/ FACTORY KNOCKOUTS.
6. ALL MATERIALS TO BE USED SHALL BE NEW AND OF APPROVED TYPE FOR THE
PARTICULAR LOCATION.
PARTICULAR LOCATION.
VICINITY MAP
7. GROUNDING SYSTEM SHALL BE PROVIDED TO ALL LIGHTING & POWER CIRCUIT AS PER
PHILLIPPINE ELECTRICAL CODE REQUIREMENTS. AND IT SHALL HAVE A GROUNDING
RESISTANCE NOT EXCEEDING 5 OHMS.
8. UNDERGROUND CONDUIT SHALL BE BURIED 600mm BELOW FINISHED GRADE LINE AND
SHALL BE ENCASED IN 20.69 MPa CONCRETE AT A MINIMUM 76mm THICKNESS ALL
AROUND.
9. MOUNTING SYSTEM OF WIRING DEVICES SHALL BE AS FOLLOWS :
A. LIGHTING SWITCH - 1.40 M. ABOVE FINISH FLOOR
B. CONVENIENCE OUTLET - 0.30 M. ABOVE FINISH FLOOR
C. SAFETY SWITCH - 1.80 M. ABOVE FINISH FLOOR
D. TELEPHONE AND CATV - 0.30 M. ABOVE FINISH FLOOR
E. WALL LAMP - 2.0 M ABOVE FINISH FLOOR
F. PB - 2.5 M ABOVE FINISH FLOOR
G. EL OUTLET - O.5 M BELOW CEILING LINE
PROJECT TITLE / LOCATION : DRAWN & PREPARED BY: REVIEWED & SUBMITTED : RECOMMENDED : APPROVED : SHEET CONTENT : SHEET NO.:
F
MDP
F
04
h
I
R
AIRCON
m l k
F
1.5hp MDP
R
E
g 05
E
W
R
W
MDP
A
03
A
AIRCON
L
W
j
e f
L
MDP MDP
L
MDP
A
2.0hp 06 MDP FGL
02 EL
L
L
L
i
MDP
01 c d
a b
GROUND FLOOR
ACU LAY-OUT
GROUND FLOOR 4 - 16 mm vertical bars w/
LIGHTING LAY-OUT 10 mm ties spread at 3 - 0.05
MCCB
FGL 3 - 0.10, 3 - 0.15 rest at 0.20 m.oc
GROUND FLOOR
POWER LAY-OUT
4 - 16 mm Bothways
t u
s
CONCRETE
AIRCON
DP
GFCI ENCASING 3
r 01 EL 4 D (diameter of uPVC conduit)
DP
02 EL DP
DP
2.0hp 06 D (diameter of uPVC conduit)
03
uPVC Conduit 3
n n DP 4 D (diameter of uPVC conduit)
DP
DP EL
04
r
p
DP DP
07 05
EL
0.5hp
AIRCON 1.5hp AIRCON
SECOND FLOOR
LIGHTING LAY-OUT SECOND FLOOR
SECOND FLOOR
POWER LAY-OUT ACU LAY-OUT CHECKED ,SIGNED & SEALED BY :
PROJECT TITLE / LOCATION : DRAWN & PREPARED BY: REVIEWED & SUBMITTED : RECOMMENDED : APPROVED : SHEET CONTENT : SHEET NO.:
PLAN
F
10mmØ BARS STAINLESS
COLUMN COLUMN STEEL HANDLE OF
I
GROUNDING GROUNDING CONCRETE COVER
COLUMN
R
GROUNDING GROUNDING ROD
GROUNDING ROD COLUMN
FGL
GROUNDING WALL MOUNTED
E
TO OTHER GROUND ROD OUTDOOR UNIT
W
50mmØ BARE COPPER WIRE
3/4Ø GRAVEL
WEEPHOLE
A
COLUMN EXOTHERMIC WELD
GROUNDING ROD GROUNDING COLUMN
L
GROUN BAR GROUNDING
L
EXPANSION BOLT WITH NEMA 3R
LOCK NUT AND WASHERS FLAT BAR 40mm X 5mm THK.
GROUNDING ROD
COLUMN COLUMN BOLT WITH NUT AND WASHERS 10mm
GROUNDING GROUNDING SOLDERLESS TERMINAL LUGS COPPER CLAD STEEL
GROUNDING ROD GROUND BUS 40 X 300 X 10mm THK. 16mmØ X 3m
TO PB
EXPANSION
BOLT
GROUND WELL DETAIL
TO GROUNDING SYSTEM FLAT BAR 40mm X 5mm THK. ANGLE BAR
AT GROUND FLOOR
GROUND BUS 40 X 300 X 10mm THK.
PAINTED FINISH
TO GROUNDING SYSTEM
AT GROUND FLOOR
GROUNDING ROD
COPPER CLAD STEEL
16mmØ X 3m
25mmØ uPVC
SECOND FLOOR
GROUNDING LAY-OUT
GROUNDING DETAIL
SIDE ELEVATION
IT
UN
IL
CO
N
CU
FA
AC
FRONT ELEVATION
PROJECT TITLE / LOCATION : DRAWN & PREPARED BY: REVIEWED & SUBMITTED : RECOMMENDED : APPROVED : SHEET CONTENT : SHEET NO.:
M
2-50 sqmm THWN 2 + 1-38 sqmm THWN2
in 50mm Ø RSC
150AT / 150AF, 2P
BOLT - ON
150AT / 150AF, 2P
BOLT - ON
FACP SPARE
100AT / 125AF, 2P
BOLT - ON
PANEL MDP
230V, 1Ø, BOLT-ON TYPE
NEMA 3R ENCLOSURE
1 - 38 mm2 THHN2 WIRE
PROJECT TITLE / LOCATION : DRAWN & PREPARED BY: REVIEWED & SUBMITTED : RECOMMENDED : APPROVED : SHEET CONTENT : SHEET NO.:
VICINITY MAP
PROJECT TITLE / LOCATION : DRAWN & PREPARED BY: REVIEWED & SUBMITTED : RECOMMENDED : APPROVED : SHEET CONTENT : SHEET NO.:
BE
AL
WEATHER PROOF
LL
50mA
4V
DC
2
F I R E W A L L
SMOKE DETECTOR FIRE ALARM BELL FIRE ALARM MANUAL
STATION
pwd ILE
toilet
F
I
R
E
FIRE ALARM CONTROL PANEL
W
MDP
AC POWER
07
FIRE ALARM ZONE DISABLE SOUND 1
A
BATTERY FAULT SOUND DISABLE SOUND 2
L
AF
ZONE 1 OPERATING INSTRUCTIONS
L
ZONE 2 1 SILENCE KEY
TURN OFF THE EXTERNAL SOUNDER
ZONE 3
2 MUTE KEY
SILENCES THE INTERNAL PIEZO
ZONE 4 SOUNDERS
ZONE 6
4 RESET KEY
RESETS THE SYSTEM
ZONE 7
5 MODE KEY
ZONE 8 ENTER THE PROGRAM MODE
SECOND FLOOR
GROUND FLOOR FDAS LAY-OUT FIRE ALARM CONTROL PANEL
FDAS LAY-OUT 4 ZONES
FIRE EXTINGUISHER HEIGHT
EQUIPMENT DRAWING
SMOKE SMOKE
DETECTOR 6" FIRE DETECTOR
ALARM BELL
LEGEND:
F FIRE EXTINGUISHER, 10 LBS.
FS FIRE ALARM MANUAL STATION
FIRE ALARM
SD MANUAL STATION
SMOKE DETECTOR
HD HEAT DETECTOR FIRE ALARM
CONTROL PANEL
2 ZONES
B FIRE ALARM BELL
FACP FIRE ALARM CONTROL PANEL, 2 ZONES
END OF LINE RESISTOR
PROJECT TITLE / LOCATION : DRAWN & PREPARED BY: REVIEWED & SUBMITTED : RECOMMENDED : APPROVED : SHEET CONTENT : SHEET NO.:
GROUND FLOOR F
I
R
E
W
A
L
L SECOND FLOOR
AUXILIARY LAY-OUT AUXILIARY LAY-OUT MISCELLANEOUS DRAWING
PROJECT TITLE / LOCATION : DRAWN & PREPARED BY: REVIEWED & SUBMITTED : RECOMMENDED : APPROVED : SHEET CONTENT : SHEET NO.: