specification
specification
Specification
SPECIFICATION
PROJECT : ONE STOREY RESIDENTIAL BUILDING
OWNER : AGUSTIN SORIANO & JEANE SORIANO
I. GENERAL CONDITION
ALL WORK INCLUDE UNDER LEADING SHALL BE SUBJECTED TO THE
GENERAL CONDITION OF THE ENTIRE OPERATION.
II. STAKE AND BATTER-BOARD
THE CONTRACTOR IS TO STAKE OUT THE BUILDING ACCURATELY AND
ERECT PERMANENT BATTER-BOARDS AT SUCH POINT THAT THEY WILL NOT
BE DISTURBED DURING THE CONSTRUCTION OF THE FOUNDATION.
III. CLEARING, GRADING AND FILLING:
THE CONTRACTOR SHALL CLEAR THE BUILDING SITE FOR THE
DISTANCE OF THREE (3) METERS IN ALL DIRECTIONS OUTSIDE OF THE
BUILDINGS LINES, WITHOUT EXTRA COMPENSATION. PROVIDED
HOWEVER, THAT THE OWNER SHALL NOT REQUIRE TO CLEAR BEYOND
AND EXISTING STREET, SHOULD BE NEARER THAN 3.0 METER TO ANY
POINT OF THE BUILDING LINES.
MASONRY WORKS
I. GENERAL CONDITION
THIS ITEM INCLUDES THE FURNISHING OF ALL LABOR AND MATERIALS
WHENEVER INDICATED IN THE PLANS AND DETAILED DRAWINGS COVERED BY
THE SPECIFICATION. USE CONCRETE HOLLOW BLOCKS 6X8X16 FOR EXTERIOR
AND 4X8X16 FOR THE INTERIOR WALLS, WITH THE CORRESPONDING FINISH
INDICATED IN THE PLANS. WHEN NOT INDICATED IN THE PLAN CEMENT
PLASTERS WITH PURE CEMENT FINISHED RECOMMENDED.
II. CONCRETE HOLLOW BLOCKS
WET THE HOLLOW BLOCKS THOROUGHLY BEFORE USING. THE FIRST ROW OF
THE BLOCKS MUST BE THOROUGHLY ANCHORED TO THE CONCRETE. THE
EXPOSED SURFACE OF THE CONCRETE HOLLOW BLOCKS, WITHOUT SPECIFIC
FINISH, SHALL BE FINISHED WITH A TOTAL OF 1/2INCH CEMENT MORTAR
CONSISTING OF ONE BAG PORTLAND CEMENT, AND FOUR (4) CUBIC FEET OF
CLEAN RIVER SAND PROPERLY SCREENED AND ALL THOROUGHLY MIXED
TOGETHER BEFORE THE NECESSARY AMOUNT OF WATER IS ADDED TO FORM
A WORKABLE MIX. CEMENT MORTAR HOLLOW BLOCKS SHALL BE COMPLETED
OR COMPLETELY FILED WITH THE ABOVED-MENTIONED CEMENT MORTAR OR
PER GRAVEL AS THE CASE MAY BE.
III. HOMOGENOUS FLOOR TILES
HOMOGENOUS FLOOR TILES SHALL BE USED WHEREVER SO INDICATED ON
THE PLANS. THEY SHALL BE UNGLAZED, FIRST CLASS QUALITY OF THE LOCAL
MANUFACTURER, WHILE 4 ¼ X 4 ¼ FREE FROM LAMINATIONS, SERRATED
EDGES, SHIPPED-OFF CORNERS AND OTHER IMPERFECTIONS, AFFECTING
THEIR QUALITY, APPEARANCES AND STRENGTH. THEY SHALL BE SOAKED IN
WATER AND EMBEDDED TO AN, FIRM AND PROPERLY SLOPED SURFACED ON
1:2 CEMENT MORTAR BASE. JOINTS BETWEEN TILES SHALL BE FILLED WITH
NEAT WHITE CEMENT AND CAREFULLY MIXED.
IV. QUALITY AND PROPORTIONING CONCRETE:
THE QUALITY OF THE PROPORTIONING CONCRETE SHALL BE AS PER BUREAU
OF PUBLIC WORKS STANDARDS.
CLASS A (1:2:4) CONCRETE MIXTURE FOR ALL FOOTING, FOUNDATIONS,WALL
FOOTING AND COLUMN.
CLASS B (1:2:4) MIXTURE FOR CONCRETE SLABS ON FILL.
(1:2) MORTAR MIX FOR ALL PLASTERING
(1:3:4) MIXTURE FOR THE CHB LAYING AND FILL.
TINNERY WORKS
I. GENERAL CONDITIONS
THE CONTRACTOR SHALL BE PROVIDED ALL ITEMS, ARTICLES, MATERIALS,
OPERATION LISTED, MENTIONED OR SCHEDULED ON THE DRAWINGS AND /ON
HEREIN, INCLUDING ALL LABOR. MATERIALS EQUIPMENT AND INCIDENTAL
NECESSARY AND REQUIRED FOR THEIR COMPLETION.
II. RIB TYPE SPAN ROOFING
ALL ROOF SHEETS SHALL BE PRE-PAINTED RIB-TYPE ROOFING.
III. RIDGE CAP AND ACCESSORIES
RIDGE FLASHING SHALL BE PRE-PAINTED SHEETS.
IV. LEADERS AND CONDUCTORS
LEADERS AND CONDUCTORS SHALL BE FORMED FROM THE #26 GAUGE G.I.
SHEET THAT MUST BE CONFORMED TO THE DRAWING AND WHERE SO
LOCATED.
ELECTRICAL WORKS
I. SCOPE OF WORKS
THE WORK COVERED BY THE SECTION OF THE SPECIFICATION CONSISTING IN FURNISHING ALL
LABOR, EQUIPMENT, SUPPLIES AND MATERIALS AND IN PERFORMING ALL OPERATIONS
NECESSARY FOR THE INSTALLATION OF COMPLETE INTERIOR WIRING SYSTEM. THE
INSTALLATION SHALL BE COMPLYING WITH THE APPLICABLE RULES OF THE NATIONAL ELECTRIC
CODE WHERE OTHERWISE NOTED ON THE DRAWING.
II. WIRING
BRANCHES CIRCUIT CONDUCTORS SHALL BE SMALLER THAN NO. 14 AWG
(AMERICAN WIRE GAUGE) EXCEPT THAT THE CONDUCTORS SHALL BE
CONTINUOUS FROM OUTLET OR JUNCTION BOXES.
OUTLET SHALL BE INSTALLED IN THE LOCATION AS SHOWN WITH THE
DRAWINGS. THE CONTRACTORS SHALL STUDY THE BUILDING PLANS IN
RELATION TO THE SPACES SURROUNDING EACH OUTLET IN ORDERS THAT HIS
WORK MAY BE FITTED TO THE OTHER WORKS REQUIRED BY THESE
SPECIFICATIONS.
III. WALL SWITCHES AND RECEPTACLES
ALL FLUSH SWITCHES SHALL BE QUITE-MATIC STANDARD TO TOGGLE TYPE
WITH BEVELED OR STAMPED FACE PLATES OF POLISHED OF LACQUIRED BAKE
LIT OF EQUAL.
IV. TESTS
AFTER THE INSTALLATION OF ALL ELECTRICAL SYSTEM AND REPORTED IN
WIRING BY THE CONTRACTOR TO BE STUDIED FOR ACCEPTANCE, TEST SHALL
BE PERFORMED IN THE PRESENCE OF THE ARCHITECT-INCHARGE FOR
ASSERTION WHETHER IT IS IN ACCORDANCE WITH THE REQUIREMENTS OF
THIS SPECIFICATIONS. SHOULD IT FAILS TO DO SO, THE CONTRACTOR SHALL
AT ONCE REMEDY ALL DEFECTS AND ERRORS AND ANY ADDITIONAL TEST
MAY BE REQUIRED SHALL BE DONE AT THE EXPENSE OF THE CONTRACTOR.
V. LIGHTING FIXTURES
ALL LIGHTING FIXTURES SHALL BE DONE BORNE FOR OUT BY THE OWNER.
REQUIREMENTS TO P.D. 1185, FIRE CODE OF THE PHILIPPINES.
ELECTRICAL WORKS
I. SCOPE OF WORKS
THE WORK FOR PLUMBING INSTALLATION SHALL BE INCLUDE THAT THE
FURNISHING OF ALL LABOR AND MATERIALS, TOOLS, EQUIPMENTS, AND
SERVICES NECESSARY FOR THE COMPLETION OF THE PLUMBING SYSTEM,
INCLUDING ALL FIXTURE AND CONNECTIONS OF DRAINAGE PIPE IS
PREFERRED TO INSURE DURABILITY. IT SHALL ALSO INCLUDE THE WATER
SERVICE TO ALL FIXTURES WITHIN THE BUILDING. THE WATER SUPPLY PIPES ,
READY TO SERVICE. THE WATER METER AND TAPPING TO THE MAIN WATER
SUPPLY SHALL BE AT THE COST OF THE OWNER.
PAINTING WORKS
I. GENERAL CONDITIONS
THE CONTRACTOR SHALL FURNISH ALL LABORS, TOOLS AND MATERIALS
NECESSARY FOR PAINTING OF ALL EXPOSED WOOD WORKS, AND CONCRETE
HOLLOW BLOCKS AND THE VARNISHING OF THE WOOD WORK TO BE
SPECIFIED BY THE ARCHITECT.
ALL PAINT MATERIALS SHALL BE SUBJECTED TO INSPECTION AND APPROVAL
OF THE ARCHITECT BEFORE ANY SUCH MATERIALS MAY BE USED. BOYSEN
PAINTS OR ITS EQUIVALENT SHALL USED IN THIS CONSTRUCTION WITH TWO
COATS FOR THE BOTH INTERIOR AND EXTERIOR.
II. WOODWORKS
WOOD SURFACES SHALL BE THOROUGHLY CLEANED, SMOOTHLY HAND
DRESSED AND SAND PAPERED BEFORE ANY PAINT OR FINISHES IS APPLIED.
ALL SAP, KNOWNS AND DEFECTS SHALL BE GIVEN A COAT OF SHER-LAC.
III. COLOR
ALL COLORS SHALL BE ACCORDANCE WITH THE SAMPLE TO BE APPROVED BY
THE ARCHITECT OR OWNER.