The DN Series™ 250 Walk-Up Through the Wall ATM features a 203mm (8") collar and is UL certified for safety. It includes detailed installation requirements, power specifications, and consumer access dimensions, emphasizing the importance of proper wall opening and electrical setup. Additionally, it outlines physical security measures, alarm protection, and environmental conditions for optimal operation.

Uploaded by

daniel
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
83 views6 pages

DN Series 250 TTW UL - 8 Inches

The DN Series™ 250 Walk-Up Through the Wall ATM features a 203mm (8") collar and is UL certified for safety. It includes detailed installation requirements, power specifications, and consumer access dimensions, emphasizing the importance of proper wall opening and electrical setup. Additionally, it outlines physical security measures, alarm protection, and environmental conditions for optimal operation.

Uploaded by

daniel
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 6

DN SERIES™ 250 WALK-UP

THROUGH THE WALL - 203mm (8") COLLAR


L1316 CALL 1-800-999-3600 UL SAFE

CONSULT WITH DIEBOLD NIXDORF INSTALLATION/SERVICE


BRANCH FOR ADDITIONAL DETAILS AND INFORMATION.
M ETRES
NCHES)

523

(20916")
73
LLI

7
NI

450 SAFE (2 8")


N MI

)
138"

)
ONS I

1 4"
35

(1734")

32
1
(
ONS I

(
M ENSI
M ENSI

OPTIONAL UPS
DI

)
181316"
(

477
DI

892 SAFE

(
)

203mm (8") MAX.


35 8"

WALL THICKNESS IN
1
)

)
4458"
1134

AREA OF UNIT
4314"
1099

(
(

WALL OPENING HEIGHT NOTE


)

VERIFY INSIDE FLOOR AND EXTERIOR LEVEL HEIGHTS PRIOR TO


8 8"
RD ANGLE

206
ON

CONSTRUCTING WALL OPENING. IF INSIDE FLOOR LEVEL IS NOT


1
PROJECTI

EQUAL TO THE EXTERIOR LEVEL, REQUIRED OPERATING HEIGHTS


MAY NOT BE MET FOR ACCESSIBILITY STANDARDS
(ADA, CSA, CAE, CEN, ETC.). CALCULATE THE CONSUMER
THI

)
1316"

ACCESS DIMENSIONS ON PAGE 2 OF 6 FROM SAFE BOTTOM.


30

478 W.O.
(

(181316")

568

(2238")

PLAN

203mm (8") MAX.


WALL THICKNESS IN
PAGE 1 OF 6

AREA OF UNIT

570 30

(22
7 (1316")
16") 1099

(4314")

OUTLINE OF OPTIONAL
ILLUMINATED SIGNAGE
)
16"

)
O.

281516"
992

)
33716"

29316"
1

741 W .

735
39

850
(
CE"
A

(
TERI

(
THOUT NOTI
GN CRI

)
1600

63"

36
)
16"
1458

(1716")
(
ONS AND DESI

7
57
SUBJECT TO CHANGE W I

NG
SEE W ALL OPENI
GHT NOTE
M ENSI

689 SAFE

)
2718"
)
26"
661

PROVIDE VERTICAL AND HORIZONTAL


ALL DI

FLAT PLUMB SURFACE AROUND WALL


(
HEI

OPENING FOR PROPER INSTALLATION


"

OF THE ATM. SEE PAGE 4 OF 6

32 OPTIONAL UPS
CABLE ENTRY OPENING
764 REV.0

FRONT ELEVATION (114") POWER CORD -


477 LENGTH
(181316") 2210mm (87")
38
FROM SIDE
(112") 400
LE NO.177-

OF UNIT
(1534")

206 892 SAFE

(818") (3518")
FI

SECTION
DN SERIES™ 250 WALK-UP
THROUGH THE WALL - 203mm (8") COLLAR
UL SAFE
L1316

CONSUMER ACCESS DIMENSIONS

* HEIGHT

746mm
DEPTH

74mm
A KEYPAD (CENTER KEY 5 PIP)
(2938") (21516")

774mm 156mm
B1 CASH IN / OUT
(3012") (618")
M ETRES
NCHES)

935mm 187mm
C CARD READER
(361316") (738")
LLI

951mm 165mm
NI

D RECEIPT PRINTER
N MI

(37716") (612")
ONS I

} 1058mm 201mm
ONS I

(STD) LOW SOFTKEY


(411116") (71516")
M ENSI

1024mm 190mm
M ENSI

E1 (DDC) LOW SOFTKEY


(40516") (712")
DI

1015mm 187mm
(

(NDC) LOW SOFTKEY


DI

(391516") (738")

} (STD) TOP SOFTKEY


1156mm
(4512")

1122mm
232mm
(918")

222mm
E2 (DDC) TOP SOFTKEY
(44316") (834")

1136mm 226mm
(NDC) TOP SOFTKEY
(4434") (81516")

1220mm 255mm
E3 TOP OF SCREEN 15"
(48116") (10116")
RD ANGLE
ON

1111mm
PROJECTI

220mm
E4 CENTER OF SCREEN 15"
(4334") (81116")

743mm 68mm
THI

F CONTACTLESS CARD READER


(21116")
(2914")

711mm 10mm
G HEADPHONE JACK
(28") 3
( 8")

709mm 15mm
H BAR CODE READER
(2778") 5
( 8")

739mm 62mm
I FINGERPRINT READER
(29116") (2716")

*
HEIGHT - FROM BOTTOM OF SAFE
DEPTH - FROM FRONT EDGE OF BEZEL
PAGE 2 OF 6

*
HEIGHT DIMENSIONS ARE FROM BOTTOM OF SAFE AND BASED ON INSIDE AND
EXTERIOR LEVELS BEING EQUAL. IN CASES WHERE AN INSTALLATION FRAME
(PLINTH) IS USED, DIMENSION WILL NEED TO BE INCREASED BY THE HEIGHT OF
THE INSTALLATION FRAME USED. SEE CUT SHEET 177-775 FOR INSTALLATION
FRAME DETAILS.
CE"
A
TERI
THOUT NOTI
GN CRI

E3
ONS AND DESI

E2
SUBJECT TO CHANGE W I

E4

E1
M ENSI

C
D
ALL DI
"

B1 F

I G

H A
764 REV.0
LE NO.177-

FRONT ELEVATION
FI
CONDUIT AND JUNCTION BOX REQUIREMENTS POWER REQUIREMENTS:
25mm (1") METAL CONDUIT FROM ALARM CONTROL CABINET JUNCTION THE TERMINAL REQUIRES A SINGLE-PHASE, THREE-WIRE UNSWITCHED POWER

1 BOX TO 102mm (4") SQ. X 54mm (218") DEEP JUNCTION BOX RECEPTACLE. WIRING TO THE RECEPTACLE MUST INCLUDE A THIRD-WIRE EARTH GROUND
L1316
(ALL BY OWNER'S E.C.(ELECTRICAL CONTRACTOR)). (CONDUIT GROUND IS NOT ACCEPTABLE). THE TERMINAL WILL PROVIDE A POWER CORD
WITH A COUNTRY SPECIFIC POWER PLUG. THE POWER SUPPLIED MUST BE AS SPECIFIED
3 BELOW.
OWNER'S E.C. TO RUN 19mm (4") LIQUID TIGHT FLEX METAL CONDUIT OR
2 3
19mm ( 4") RIGID CONDUIT FROM JUNCTION BOX TO CABLE OPENING IN SAFE. CHOOSE AND SUPPLY THE PROPER POWER FOR THE SITE:
100-127 VAC (+6%, -10%) AT 50 (±1%) Hz, SINGLE-PHASE
3
19mm ( 4") METAL CONDUIT AND UNSWITCHED ELECTRICAL SUPPLY TO 100-127 VAC (+6%, -10%) AT 60 (±1%) Hz, SINGLE-PHASE
102mm (4") SQ. X 54mm (218") DEEP JUNCTION BOX WITH RECEPTACLE 200-240 VAC (±10%) AT 50 (±1%) Hz, SINGLE-PHASE
3
WITHIN 2210mm (87") OF CABLE OPENING IN SAFE. (ALL BY OWNER'S E.C.) 200-240 VAC (±10%) AT 60 (±1%) Hz, SINGLE-PHASE
(SEE POWER REQUIREMENTS).
POWER TO THE TERMINAL IS TO BE A DEDICATED SERVICE AND MUST BE PROTECTED BY A
SAFETY QUICK-DISCONNECT DEVICE TO BREAK LINE VOLTAGE (SUCH AS A CIRCUIT BREAKER
M ETRES

OWNER'S E.C. TO SUPPLY COMPATIBLE RECEPTACLE FOR COUNTRY


AT THE ELECTRICAL SERVICE PANEL. THE QUICK-DISCONNECT DEVICE (OR CIRCUIT
NCHES)

4 SPECIFIC PLUG-IN CONNECTOR SUPPLIED WITH UNIT. POWER CORD


BREAKER) MUST TURN OFF THE LINE VOLTAGE AT THE FOLLOWING AMPERAGE.
LENGTH 2210mm (87") FROM CABLE OPENING IN SAFE.
100-127 VAC (+6%, -10%) SERVICE, DISCONNECT AT 20 AMPERES
NOTE: 200-240 VAC (±10%) SERVICE, DISCONNECT AT 10 AMPERES
LLI
NI

JUNCTION BOXES MUST BE LOCATED WITHIN 2210mm (87") OF CABLE OPENING IN SAFE. THE MODULE BULK POWER SUPPLY AND PROCESSOR POWER SUPPLY WILL PROVIDE
N MI
ONS I

(LENGTH OF ELECTRICAL POWER CABLE PROVIDED WITH UNIT). LOCATE IN AN EASILY POWER CONDITIONING TO PREVENT THE TERMINAL FROM MALFUNCTIONING DUE TO
ACCESSIBLE AREA. SHORT-TERM AC POWER FLUCTUATIONS AS OUTLINED IN EN61000-4-11.
ONS I

BOXES CAN BE FLUSH MOUNTED WITH CONCEALED CONDUIT FOR NEW CONSTRUCTION OR
POWER USAGE:
M ENSI

BOXES CAN BE SURFACE MOUNTED WITH EXPOSED CONDUIT FOR EXISTING CONSTRUCTION.
MAX. USAGE
M ENSI

PHYSICAL SECURITY TERMINAL WITH


WITH HEATER
UL RATED ATM SAFES MEET THE ATTACK TEST REQUIREMENTS DEFINED IN UL 291-15. THE MACHINE STATUS CONFIGURED HEATER
DI

and BATTERY
AS NOTED (+400 WATTS)
SAFE DOOR FEATURES A POSITIVE RELOCKING DEVICE. ACCESS TO THE SAFE DOOR IS CHARGING
(

BELOW
DI

MANAGED BY AN INSTALLED MECHANICAL OR ELECTRONIC COMBINATION LOCK OR LOCKS (+130 WATTS)


THAT ARE UL CERTIFIED, VDS CERTIFIED CLASS 1 OR CLASS 2, AND/OR EN-1300 CERTIFIED
CLASS A OR CLASS B DEPENDING ON THE SYSTEM CONFIGURATION. CONSULT THE SYSTEM IDLE MODE (NO TRANSACTION) 120 WATTS 520 WATTS 650 WATTS
OPERATING GUIDE FOR FURTHER INFORMATION.
OPERATION (MAXIMUM) 330 WATTS 730 WATTS 860 WATTS
BUILDING AIR PRESSURE
BUILDING AIR PRESSURE DIFFERENCES AT THE TERMINAL INSTALLATION LOCATION AFFECT
THE INFILTRATION OF OUTSIDE AIR AND ACCOMPANY DIRT. THE TERMINAL WILL OPERATE TERMINAL CONFIGURATION:
THROUGH ITS FULL RANGE OF FASCIA TEMPERATURES -34º C TO 54º C (-29º F TO 129º F) WITH DIP CARD READER, RECEIPT PRINTER WITH RETRACT, CASH IN/OUT RM4V, 15”SUNLIGHT
ZERO (STATIC) OR POSITIVE AIR PRESSURE DIFFERENTIAL (MEASURED FROM THE INSIDE TO VIEWABLE DISPLAY, HIGH PERFORMANCE PC, CONTACTLESS CARD READER, BATTERY
THE OUTSIDE OF THE BUILDING AT THE TERMINAL INSTALLATION LOCATION). IF STATIC OR INSTALLED, CHECK DEPOSIT AND 400 W HEATER.
POSITIVE AIR PRESSURE CANNOT BE MAINTAINED, THE FASCIA LOWER LIMIT TEMPERATURE
THE POWER USE DEPENDS ON THE NUMBER AND TYPE OF DEVICES PRESENT IN
IS -20º C (-4º F). THE MAXIMUM NEGATIVE AIR PRESSURE ALLOWED IS 0.05" H O.
2 THE TERMINAL, AND THE TYPE OF TRANSACTION THE TERMINAL IS PERFORMING.
RD ANGLE
ON

ALARM PROTECTION VALUES ABOVE ARE BASED ON MEASURED AVERAGES FOR THE CONFIGURATION LISTED.
PROJECTI

UL RATED SAFES ARE EQUIPPED WITH A SAFE DOOR SWITCH BY DEFAULT. ADDITIONAL
ALARM AND SENSOR PACKAGES ARE AVAILABLE TO MONITOR FOR VARIOUS ATTACK
HEAT OUTPUT CONFIGURATION:
VECTORS. CONSULT THE SYSTEM OPERATING GUIDE FOR FURTHER INFORMATION. 470 AVERAGE BTU/HR - USING 99KwH PER MONTH AS TYPICAL POWER CONSUMPTION.
THI

HEAT OUTPUT VALUE IS BASED ON APPROXIMATELY 240 TRANSACTIONS PER DAY AND
SIGNAL CABLE RUN CONSTRAINTS ASSUMES NO ADDITIONAL POWER CONSUMPTION OR HEAT CONTRIBUTION FROM
THE FOLLOWING CHART ITEMIZES THE PHYSICAL SPACING REQUIREMENTS OF THE SIGNAL HEATERS IN COLD ENVIRONMENTS.
CABLE RUN WITH RESPECT TO OTHER POWER AND ELECTRICAL EQUIPMENT CABLE RUN.
1,379 BTU/HR WHEN HEATER IS OPERATING.

SEPARATION FROM OTHER CABLES


CLIMATIC ENVIRONMENTAL CONDITIONS:
TYPE OF ELECTRICAL RUN BELOW 2 KVA 2-5 KVA ABOVE 5 KVA

FLUORESCENT, NEON OR INCANDESCENT STATUS AIR TEMPERATURE RELATIVE AIR HUMIDITY


127mm (5") 127mm (5") 127mm (5")
LIGHTING FIXTURES
0°C to 40°C
UNSHIELDED POWER LINE OR INSIDE 10 to 85%
127mm (5") 305mm (1'-0") 610mm (2'-0") (32°F to 104°F)
ELECTRICAL EQUIPMENT
OPERATION
UNSHIELDED POWER LINES OR -40°C to 50°C
OUTSIDE 5 to 85%
ELECTRICAL EQUIPMENT WITH (-40°F to 122°F)
64mm (212") 152mm (6") 305mm (1'-0")
SIGNAL CABLES ENCLOSED IN
TRANSPORT -25°C to 60°C (-13°F to 140°F) 15 to 98%
GROUNDED CONDUIT
PAGE 3 OF 6

POWER LINES IN GROUNDED CONDUIT STORAGE -10°C to 40°C (14°F to 104°F) 5 to 98%
WITH SIGNAL CABLES IN GROUNDED 30mm (1316") 76mm (3") 152mm (6")
CONDUIT

SIGNAL CABLE INSTALLATION CONSTRAINTS: WEIGHT OF UNIT:


480 kg (1,058 LBS.)
RELATIVE CARE IS REQUIRED WHEN INSTALLING SIGNAL CABLES IN CONDUITS, UNLIKE POWER
AND LIGHTING CABLE, SIGNAL CABLES HAVE CONDUCTORS AND LIGHT INSULATION AND WILL ACTUAL WEIGHT OF THE TERMINAL WILL DEPEND ON THE
NOT WITHSTAND AS MUCH STRAIN IN INSTALLATION. CONFIGURATION OF THE TERMINAL COMPONENTS AND OPTIONS

450

(171116")
1099
119
)
212"

(4314")
63

(41116") 101
(
CE"
A

(4")
TERI
THOUT NOTI
GN CRI

AIR VENTS
ONS AND DESI

)
31516"

OPTIONAL UPS
SUBJECT TO CHANGE W I

)
99

O.
281516"

)
29316"
741 W .
735
(

1
(

(
M ENSI
ALL DI

3
)
5618"
1425
"

3
(

ON PAGE 1 AND 4 OF 6
NG
)
24 8"

SEE W ALL OPENI


612

GHT NOTE
1

689 SAFE

1
)

)
2718"

26116"
(

661
764 REV.0

4
(

HEI

2
)
152

6"
(
LE NO.177-

450 SAFE 892 SAFE

73 (171116") (3518")

(278")
SIDE ELEVATION
FI

BACK ELEVATION
DN SERIES™ 250 WALK-UP
THROUGH THE WALL - 203mm (8") COLLAR
L1316 WALL OPENING DETAIL
UL SAFE
M ETRES
NCHES)

203mm (8") MAX.


WALL THICKNESS IN
AREA OF UNIT
LLI
NI
N MI
ONS I
ONS I
M ENSI
M ENSI
DI
(
DI

478 W.O.

(181316") WALL OPENING HEIGHT NOTE


VERIFY INSIDE FLOOR AND EXTERIOR LEVEL HEIGHTS PRIOR TO
CONSTRUCTING WALL OPENING. IF INSIDE FLOOR LEVEL IS NOT
PLAN EQUAL TO THE EXTERIOR LEVEL, REQUIRED OPERATING HEIGHTS
MAY NOT BE MET FOR ACCESSIBILITY STANDARDS
(ADA, CSA, CAE, CEN, ETC.). CALCULATE THE CONSUMER
ACCESS DIMENSIONS ON PAGE 2 OF 6 FROM SAFE BOTTOM.
RD ANGLE
ON
PROJECTI
THI

PROVIDE VERTICAL AND HORIZONTAL


FLAT PLUMB SURFACE EXTENDED FOR
USE WITH ILLUMINATED SIGNAGE
PAGE 4 OF 6

84 84
5
(3516") 478 W.O. (316")

(181316") 203mm (8") MAX.


WALL THICKNESS IN
AREA OF UNIT
)
914"
236

)
312"
88

(
O.

O.

)
)

29316"
741 W .

741 W .
2918"
CE"
A
TERI

(
THOUT NOTI
GN CRI

)
31116"
94
ONS AND DESI

(
SUBJECT TO CHANGE W I

NG
SEE W ALL OPENI
GHT NOTE
M ENSI

)
26"

26"
661

661
ALL DI

PROVIDE VERTICAL AND HORIZONTAL


(

FLAT PLUMB SURFACE AROUND WALL


HEI
"

OPENING FOR PROPER INSTALLATION


OF THE ATM
764 REV.0

EXTERIOR ELEVATION 203

(8")

VERTICAL SECTION
LE NO.177-
FI
DN SERIES™ 250 WALK-UP
THROUGH THE WALL - 203mm (8") COLLAR
L1316
REQUIRED MINIMUM SERVICE AREAS
UL SAFE
1450 1450

(5718") (5718")

500 450 SAFE 500 500 450 SAFE 500


11 11 11 11 11 11
(19 16") (17 16") (19 16") (19 16") (17 16") (19 16")
M ETRES
NCHES)
LLI
NI
N MI

)
ONS I

39 8"

3938"
1000

1000
)

)
431116"

431116"
3
1110

1110
ONS I

(
M ENSI

(
50 50
M ENSI

50 50
(11516") (11516") (11516") (11516")
DI
(
DI

)
8258"

8258"
2099

2099
(

(
)

)
16"

211116"
550

550
11
21
(

(
)

)
381516"

381516"
989

989
RD ANGLE
ON
PROJECTI

(
REQUIRED WITH REQUIRED WITH
OPTIONAL UPS OPTIONAL UPS
THI

486 478 W.O. 186 186 478 W.O. 486

(1918") (181316") (7516") (7516") (181316") (1918")

1149 1149
)

)
3678"

3678"

1 1
(45 4") (45 4")
937

937
(

(
PAGE 5 OF 6

PLAN PLAN
EXTERIOR SERVICE AREA LEFT EXTERIOR SERVICE AREA RIGHT

965 1936

(38") (76316")

203mm (8") MAX.


)

WALL THICKNESS IN
11516"
CE"
A
TERI

AREA OF UNIT
50
THOUT NOTI
GN CRI

(
ONS AND DESI
SUBJECT TO CHANGE W I

O.
M ENSI

29316")
741 W .
ALL DI

(
)
"

65 8"
1654
1

)
56116"

1474

58"
(

1424

(
(
764 REV.0

)
27116"
)

688
26"
661

(
LE NO.177-
FI

SECTION
DN SERIES™ 250 WALK UP
THROUGH THE WALL - 203mm (8") COLLAR
L1316 UL SAFE ANCHOR LOCATIONS
450 SAFE

(171116")
58 58

(214") (214")
335

(13316")
M ETRES
NCHES)
LLI
NI
N MI
ONS I
ONS I
M ENSI
M ENSI

1 1

)
DI

112"
38
(

892 SAFE
DI

)
(

35 8"
1
2

(
CABLE ENTRY
OPENING

)
1678"
)
17"

428
432

(SEE NOTE)
(

)
1718"
)

435
1534"
400

(
(
RD ANGLE
ON

)
PROJECTI

41316"
1
)

1
458"

122
118

(
THI

337

55 (1314") 58
(2316") (214")

PLAN/SECTION SAFE FLOOR


1 - (4) 25.4mm (1") DIA. FLOOR MOUNTING HOLES

2 - (1) 22mm 7
(8") DIA. TEAR OFF SENSOR HOLE (FLOOR HOLE DRILL SIZE DETERMINED AT SITE)
PAGE 6 OF 6

ANCHORING SAFE TO CONCRETE FLOORS:


DIEBOLD NIXDORF RECOMMENDS (4) M20 ANCHOR BOLTS THAT ARE 170mm (61116”) LONG FOR PROPERLY SECURING THE
UNIT (PART #01750308241). THE OVERALL DRILLING DEPTH DEPENDS ON STRUCTURAL CONDITIONS. THE MOUNTING ANCHORS

16”) DEEP IN THE LOAD BEARING CONCRETE (SEE DETAIL). ANCHOR BOLTS MUST BE
15
MUST BE LOCATED AT LEAST 125mm (4
USED IN ALL (4) AVAILABLE ANCHOR HOLES. IF MOUNTING KIT IS NOT PROVIDED, USE EQUIVALENT FASTENING MATERIAL.

OPTIONAL TEAR-OFF SENSOR


M AX.

FLOOR
(4) SAFE FLOOR MOUNTING SETS
FINISH
)
4"
19
3
(
CE"
A
TERI
THOUT NOTI
GN CRI

M UM
16"
125

UL SAFE FLOOR
ONS AND DESI

15

NI
SUBJECT TO CHANGE W I

MI
(
M ENSI
ALL DI

SECTION THROUGH SAFE FLOOR


"

FOR ILLUSTRATION ONLY - NOT TO SCALE

ANCHORING SAFE TO STEEL FLOORS:


SYSTEMS INSTALLED ON A STEEL FLOOR CAN ALSO BE SECURED BY A MACHINE-THREADED NUT AND BOLT METHOD.
DIEBOLD NIXDORF RECOMMENDS THE HARDWARE BE ATTACHED THROUGH SUPPORTING STEEL POST OR BEAMS FOR
764 REV.0

MAXIMUM HOLDING CAPACITY. ADDITIONALLY, THIS HARDWARE MUST ATTACH TO A LOCALLY FABRICATED REINFORCEMENT
PLATE INSTALLED BELOW THE FLOOR TO PROVIDE ADDITIONAL STRENGTH. THE STEEL BACKING PLATE THICKNESS MUST
(2”). MACHINE-THREADED NUT AND BOLT MUST BE USED IN ALL (4) AVAILABLE ANCHOR HOLES.
BE A MINIMUM OF 13mm 1
LE NO.177-

ANCHORING SAFE USING AN INSTALLATION FRAME (PLINTH):


THE INSTALLATION FRAME MUST BE SECURED TO THE FLOOR USING (4) SUPPLIED THREADED RODS AT FOUR ANCHORING
POINTS (SEE CUT SHEET #177-775 FOR INSTALLATION FRAME DETAILS). THE SYSTEM SAFE IS SECURED TO THE INSTALLATION
FRAME USING (4) M16 X 40mm (1.57”) PAN HEAD SCREWS AND WASHERS (PART #01750308238). IF MOUNTING KIT IS NOT PROVIDED,
USE EQUIVALENT FASTENING MATERIAL.
FI