DN Series 250 TTW UL - 8 Inches
DN Series 250 TTW UL - 8 Inches
523
(20916")
73
LLI
7
NI
)
138"
)
ONS I
1 4"
35
(1734")
32
1
(
ONS I
(
M ENSI
M ENSI
OPTIONAL UPS
DI
)
181316"
(
477
DI
892 SAFE
(
)
WALL THICKNESS IN
1
)
)
4458"
1134
AREA OF UNIT
4314"
1099
(
(
206
ON
)
1316"
478 W.O.
(
(181316")
568
(2238")
PLAN
AREA OF UNIT
570 30
(22
7 (1316")
16") 1099
(4314")
OUTLINE OF OPTIONAL
ILLUMINATED SIGNAGE
)
16"
)
O.
281516"
992
)
33716"
29316"
1
741 W .
735
39
850
(
CE"
A
(
TERI
(
THOUT NOTI
GN CRI
)
1600
63"
36
)
16"
1458
(1716")
(
ONS AND DESI
7
57
SUBJECT TO CHANGE W I
NG
SEE W ALL OPENI
GHT NOTE
M ENSI
689 SAFE
)
2718"
)
26"
661
32 OPTIONAL UPS
CABLE ENTRY OPENING
764 REV.0
OF UNIT
(1534")
(818") (3518")
FI
SECTION
DN SERIES™ 250 WALK-UP
THROUGH THE WALL - 203mm (8") COLLAR
UL SAFE
L1316
* HEIGHT
746mm
DEPTH
74mm
A KEYPAD (CENTER KEY 5 PIP)
(2938") (21516")
774mm 156mm
B1 CASH IN / OUT
(3012") (618")
M ETRES
NCHES)
935mm 187mm
C CARD READER
(361316") (738")
LLI
951mm 165mm
NI
D RECEIPT PRINTER
N MI
(37716") (612")
ONS I
} 1058mm 201mm
ONS I
1024mm 190mm
M ENSI
1015mm 187mm
(
(391516") (738")
1122mm
232mm
(918")
222mm
E2 (DDC) TOP SOFTKEY
(44316") (834")
1136mm 226mm
(NDC) TOP SOFTKEY
(4434") (81516")
1220mm 255mm
E3 TOP OF SCREEN 15"
(48116") (10116")
RD ANGLE
ON
1111mm
PROJECTI
220mm
E4 CENTER OF SCREEN 15"
(4334") (81116")
743mm 68mm
THI
711mm 10mm
G HEADPHONE JACK
(28") 3
( 8")
709mm 15mm
H BAR CODE READER
(2778") 5
( 8")
739mm 62mm
I FINGERPRINT READER
(29116") (2716")
*
HEIGHT - FROM BOTTOM OF SAFE
DEPTH - FROM FRONT EDGE OF BEZEL
PAGE 2 OF 6
*
HEIGHT DIMENSIONS ARE FROM BOTTOM OF SAFE AND BASED ON INSIDE AND
EXTERIOR LEVELS BEING EQUAL. IN CASES WHERE AN INSTALLATION FRAME
(PLINTH) IS USED, DIMENSION WILL NEED TO BE INCREASED BY THE HEIGHT OF
THE INSTALLATION FRAME USED. SEE CUT SHEET 177-775 FOR INSTALLATION
FRAME DETAILS.
CE"
A
TERI
THOUT NOTI
GN CRI
E3
ONS AND DESI
E2
SUBJECT TO CHANGE W I
E4
E1
M ENSI
C
D
ALL DI
"
B1 F
I G
H A
764 REV.0
LE NO.177-
FRONT ELEVATION
FI
CONDUIT AND JUNCTION BOX REQUIREMENTS POWER REQUIREMENTS:
25mm (1") METAL CONDUIT FROM ALARM CONTROL CABINET JUNCTION THE TERMINAL REQUIRES A SINGLE-PHASE, THREE-WIRE UNSWITCHED POWER
1 BOX TO 102mm (4") SQ. X 54mm (218") DEEP JUNCTION BOX RECEPTACLE. WIRING TO THE RECEPTACLE MUST INCLUDE A THIRD-WIRE EARTH GROUND
L1316
(ALL BY OWNER'S E.C.(ELECTRICAL CONTRACTOR)). (CONDUIT GROUND IS NOT ACCEPTABLE). THE TERMINAL WILL PROVIDE A POWER CORD
WITH A COUNTRY SPECIFIC POWER PLUG. THE POWER SUPPLIED MUST BE AS SPECIFIED
3 BELOW.
OWNER'S E.C. TO RUN 19mm (4") LIQUID TIGHT FLEX METAL CONDUIT OR
2 3
19mm ( 4") RIGID CONDUIT FROM JUNCTION BOX TO CABLE OPENING IN SAFE. CHOOSE AND SUPPLY THE PROPER POWER FOR THE SITE:
100-127 VAC (+6%, -10%) AT 50 (±1%) Hz, SINGLE-PHASE
3
19mm ( 4") METAL CONDUIT AND UNSWITCHED ELECTRICAL SUPPLY TO 100-127 VAC (+6%, -10%) AT 60 (±1%) Hz, SINGLE-PHASE
102mm (4") SQ. X 54mm (218") DEEP JUNCTION BOX WITH RECEPTACLE 200-240 VAC (±10%) AT 50 (±1%) Hz, SINGLE-PHASE
3
WITHIN 2210mm (87") OF CABLE OPENING IN SAFE. (ALL BY OWNER'S E.C.) 200-240 VAC (±10%) AT 60 (±1%) Hz, SINGLE-PHASE
(SEE POWER REQUIREMENTS).
POWER TO THE TERMINAL IS TO BE A DEDICATED SERVICE AND MUST BE PROTECTED BY A
SAFETY QUICK-DISCONNECT DEVICE TO BREAK LINE VOLTAGE (SUCH AS A CIRCUIT BREAKER
M ETRES
JUNCTION BOXES MUST BE LOCATED WITHIN 2210mm (87") OF CABLE OPENING IN SAFE. THE MODULE BULK POWER SUPPLY AND PROCESSOR POWER SUPPLY WILL PROVIDE
N MI
ONS I
(LENGTH OF ELECTRICAL POWER CABLE PROVIDED WITH UNIT). LOCATE IN AN EASILY POWER CONDITIONING TO PREVENT THE TERMINAL FROM MALFUNCTIONING DUE TO
ACCESSIBLE AREA. SHORT-TERM AC POWER FLUCTUATIONS AS OUTLINED IN EN61000-4-11.
ONS I
BOXES CAN BE FLUSH MOUNTED WITH CONCEALED CONDUIT FOR NEW CONSTRUCTION OR
POWER USAGE:
M ENSI
BOXES CAN BE SURFACE MOUNTED WITH EXPOSED CONDUIT FOR EXISTING CONSTRUCTION.
MAX. USAGE
M ENSI
and BATTERY
AS NOTED (+400 WATTS)
SAFE DOOR FEATURES A POSITIVE RELOCKING DEVICE. ACCESS TO THE SAFE DOOR IS CHARGING
(
BELOW
DI
ALARM PROTECTION VALUES ABOVE ARE BASED ON MEASURED AVERAGES FOR THE CONFIGURATION LISTED.
PROJECTI
UL RATED SAFES ARE EQUIPPED WITH A SAFE DOOR SWITCH BY DEFAULT. ADDITIONAL
ALARM AND SENSOR PACKAGES ARE AVAILABLE TO MONITOR FOR VARIOUS ATTACK
HEAT OUTPUT CONFIGURATION:
VECTORS. CONSULT THE SYSTEM OPERATING GUIDE FOR FURTHER INFORMATION. 470 AVERAGE BTU/HR - USING 99KwH PER MONTH AS TYPICAL POWER CONSUMPTION.
THI
HEAT OUTPUT VALUE IS BASED ON APPROXIMATELY 240 TRANSACTIONS PER DAY AND
SIGNAL CABLE RUN CONSTRAINTS ASSUMES NO ADDITIONAL POWER CONSUMPTION OR HEAT CONTRIBUTION FROM
THE FOLLOWING CHART ITEMIZES THE PHYSICAL SPACING REQUIREMENTS OF THE SIGNAL HEATERS IN COLD ENVIRONMENTS.
CABLE RUN WITH RESPECT TO OTHER POWER AND ELECTRICAL EQUIPMENT CABLE RUN.
1,379 BTU/HR WHEN HEATER IS OPERATING.
POWER LINES IN GROUNDED CONDUIT STORAGE -10°C to 40°C (14°F to 104°F) 5 to 98%
WITH SIGNAL CABLES IN GROUNDED 30mm (1316") 76mm (3") 152mm (6")
CONDUIT
450
(171116")
1099
119
)
212"
(4314")
63
(41116") 101
(
CE"
A
(4")
TERI
THOUT NOTI
GN CRI
AIR VENTS
ONS AND DESI
)
31516"
OPTIONAL UPS
SUBJECT TO CHANGE W I
)
99
O.
281516"
)
29316"
741 W .
735
(
1
(
(
M ENSI
ALL DI
3
)
5618"
1425
"
3
(
ON PAGE 1 AND 4 OF 6
NG
)
24 8"
GHT NOTE
1
689 SAFE
1
)
)
2718"
26116"
(
661
764 REV.0
4
(
HEI
2
)
152
6"
(
LE NO.177-
73 (171116") (3518")
(278")
SIDE ELEVATION
FI
BACK ELEVATION
DN SERIES™ 250 WALK-UP
THROUGH THE WALL - 203mm (8") COLLAR
L1316 WALL OPENING DETAIL
UL SAFE
M ETRES
NCHES)
478 W.O.
84 84
5
(3516") 478 W.O. (316")
)
312"
88
(
O.
O.
)
)
29316"
741 W .
741 W .
2918"
CE"
A
TERI
(
THOUT NOTI
GN CRI
)
31116"
94
ONS AND DESI
(
SUBJECT TO CHANGE W I
NG
SEE W ALL OPENI
GHT NOTE
M ENSI
)
26"
26"
661
661
ALL DI
(8")
VERTICAL SECTION
LE NO.177-
FI
DN SERIES™ 250 WALK-UP
THROUGH THE WALL - 203mm (8") COLLAR
L1316
REQUIRED MINIMUM SERVICE AREAS
UL SAFE
1450 1450
(5718") (5718")
)
ONS I
39 8"
3938"
1000
1000
)
)
431116"
431116"
3
1110
1110
ONS I
(
M ENSI
(
50 50
M ENSI
50 50
(11516") (11516") (11516") (11516")
DI
(
DI
)
8258"
8258"
2099
2099
(
(
)
)
16"
211116"
550
550
11
21
(
(
)
)
381516"
381516"
989
989
RD ANGLE
ON
PROJECTI
(
REQUIRED WITH REQUIRED WITH
OPTIONAL UPS OPTIONAL UPS
THI
1149 1149
)
)
3678"
3678"
1 1
(45 4") (45 4")
937
937
(
(
PAGE 5 OF 6
PLAN PLAN
EXTERIOR SERVICE AREA LEFT EXTERIOR SERVICE AREA RIGHT
965 1936
(38") (76316")
WALL THICKNESS IN
11516"
CE"
A
TERI
AREA OF UNIT
50
THOUT NOTI
GN CRI
(
ONS AND DESI
SUBJECT TO CHANGE W I
O.
M ENSI
29316")
741 W .
ALL DI
(
)
"
65 8"
1654
1
)
56116"
1474
58"
(
1424
(
(
764 REV.0
)
27116"
)
688
26"
661
(
LE NO.177-
FI
SECTION
DN SERIES™ 250 WALK UP
THROUGH THE WALL - 203mm (8") COLLAR
L1316 UL SAFE ANCHOR LOCATIONS
450 SAFE
(171116")
58 58
(214") (214")
335
(13316")
M ETRES
NCHES)
LLI
NI
N MI
ONS I
ONS I
M ENSI
M ENSI
1 1
)
DI
112"
38
(
892 SAFE
DI
)
(
35 8"
1
2
(
CABLE ENTRY
OPENING
)
1678"
)
17"
428
432
(SEE NOTE)
(
)
1718"
)
435
1534"
400
(
(
RD ANGLE
ON
)
PROJECTI
41316"
1
)
1
458"
122
118
(
THI
337
55 (1314") 58
(2316") (214")
2 - (1) 22mm 7
(8") DIA. TEAR OFF SENSOR HOLE (FLOOR HOLE DRILL SIZE DETERMINED AT SITE)
PAGE 6 OF 6
16”) DEEP IN THE LOAD BEARING CONCRETE (SEE DETAIL). ANCHOR BOLTS MUST BE
15
MUST BE LOCATED AT LEAST 125mm (4
USED IN ALL (4) AVAILABLE ANCHOR HOLES. IF MOUNTING KIT IS NOT PROVIDED, USE EQUIVALENT FASTENING MATERIAL.
FLOOR
(4) SAFE FLOOR MOUNTING SETS
FINISH
)
4"
19
3
(
CE"
A
TERI
THOUT NOTI
GN CRI
M UM
16"
125
UL SAFE FLOOR
ONS AND DESI
15
NI
SUBJECT TO CHANGE W I
MI
(
M ENSI
ALL DI
MAXIMUM HOLDING CAPACITY. ADDITIONALLY, THIS HARDWARE MUST ATTACH TO A LOCALLY FABRICATED REINFORCEMENT
PLATE INSTALLED BELOW THE FLOOR TO PROVIDE ADDITIONAL STRENGTH. THE STEEL BACKING PLATE THICKNESS MUST
(2”). MACHINE-THREADED NUT AND BOLT MUST BE USED IN ALL (4) AVAILABLE ANCHOR HOLES.
BE A MINIMUM OF 13mm 1
LE NO.177-