0% found this document useful (0 votes)
3 views

srs2026c

The document provides detailed specifications and safety warnings for various refrigerator models, including the SR-S2026C(D) to SR-S2229C(D). It outlines product dimensions, electrical components, and operating principles, as well as instructions for assembly, disassembly, and repair methods. Safety precautions are emphasized to prevent hazards such as electric shock and fire.

Uploaded by

Heru susanto
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
3 views

srs2026c

The document provides detailed specifications and safety warnings for various refrigerator models, including the SR-S2026C(D) to SR-S2229C(D). It outlines product dimensions, electrical components, and operating principles, as well as instructions for assembly, disassembly, and repair methods. Safety precautions are emphasized to prevent hazards such as electric shock and fire.

Uploaded by

Heru susanto
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 105

Model : SR-S2026C(D) SR-S2226C(D)

SR-S2027C(D) SR-S2227C(D)
SR-S2028C(D) SR-S2228C(D)
SR-S2029C(D) SR-S2229C(D)
SR-S20NTC(D) SR-S22NTC(D)
SR-S20BTC(D) SR-S22BTC(D)
SR-S20DTC(D) SR-S22DTC(D)
SR-S20FTC(D) SR-S22FTC(D)

SERVICE “°"™
REFRIGERATOR
1. Product Specification oo... ccccccccccessescseseeesneesesseetteiensenseesseet 2
2. Safety Warning & Caution ooo... ccccesssssseeessussssseeceessnnnen 3

3. Specification of Electric COMPONENES oestrone 5

A. Circuit Dig Gra ec. cases. Sag hkitastetiass


chests tater 7
5. Dimension & Part Name of Refrigerator 0... eee 9

6. Freezing Cycle & Cold Air Circulation


Course in Refrigerator ............ eeOre mTCe: 15
7, Function & Operating Instruction of Refrigerator .................... 17
8. Operating Principle of Circuit oo. ecscesssesssseceessesseeeseceecien 26
9. Trouble Checkup & Repair Method o.oo... eccenee 34
10. Operation Principle & Repair Method of ICE-MAKER .......... 50
11: Reference. 2. cceu desescsnntensssieensciecnclia
rarascceotiscoth decades 55
12. Disassembly Method of Freezer & Refrigerator .................. 60
13. Method of Hinge up Assembly & Disassembly ................ 63
14. Refrigerator Exploded view & List ooo ccccee 64
15. Machine Room Assembly Specification 0. 89

16. Disassembly & Assembly Method of Internal Part of


Electric:Field Box. .::...cccccecsatwinn
Ghia ditsieieneenagthe 90
17. Installation Method of Water Supply Tube cee 91
18. Installation of the Water Dispenser Line oo... 92
19. PCB Circuit Diagram and Service Components List ............ 93
20. Specification of Principal Part of Circuit 0.0...ee 94

N(
t
ii
N
lM
N
ie
eoMrn
1. Product Specifications.

Item Specification

SR-S2026C(D) SR-S2027C(D) |SR-S2028C(D) |SR-S2029C(D)


Model SR-S20NTC(D) |SR-S20BTC(D) |SR-S20DTC(D) |SR-S20FTC(D)
Basic Basic& H/B Dispenser | Dispenser& H/B

Net dimension(W XH XD) 908mm x 719(724)mm x 1760mm

Rated Frequency and Frequency 230~240V/50Hz

Motor Rated Consumption Power 160W

Eiectric Heater Rated Consumption Power 365W

Kind of Refrigerator Indirect Cooling Method Refrigerator

we Refrigerant HFC-134a
rant inp 190gr
(4-STAR)

Product Weight 111Kg 111Kg 117Kg 117Kg


Specification

SR-$2226C(D) |SR-$2227C(D) SR-$2228C(D)| SR-S2229C(D)


SR-S22NTC(D) |SR-S22BTC(D)} SR-S22DTC(D)| SR-S22FTC(D)
Basic Basic’& H/B Dispenser: | Dispenser& H/B


Net

Z
Inside: | -

“Refri
az
372
E
372
Outer Size (width: -depth X height) 908mm x 754(759)mm x 1760mm
Rated Frequency and Frequency 230~240V/50Hz
Motor Rate ‘Cons mption Power 155W 160W
Electric Heater Rated Consumption Power 365W
Kind ofRefrigerator Indirect Cooling Method Refrigerator

. Refrigerant HFC-134a
Refrigerant InputAmount 190gr
FreezerPerfomance (4-STAR)
, pide Weg eo 121Kg 121Kg 127Kg 127Kg
2. SAFETY WARNINGS

Read all instructions before using this product and keep to the instructions
in order to prevent danger or property damage.

CAUTIONWARNING SYMBOLS DISPLAYED SYMBOLS


pale
||
0)
if

| Indicates that a means “Prohibition”.


i
._ danger of death
JA Warning or serious injury | | means “Do not disassemble”.
exists. |
5 means “No contact”.
| means “The things to
Indicates that a risk | be followed”.
»_ Of personal injury means “Power cord should be
|/\ caution or material damage | unplugged from the consent”

CHOSSS
{
exists. means “Earth to prevent Electric
|
be __ Shock”, —!

Warning |
Do not insert the power plugs Do not disassemble, Do not bend the power cord
for many products at the repair or alter. with excessive force or do not
same time. have the power cord pressed
olt may cause fire or abnormal by heavy article.
@May cause abnormal operation which leads to injury. She BS
generation of heat or fire. oMay cause fire.

Prohibition Do not
disassemble

Do not install the refrigerator Make sure of the earth. Pull the power plug out to
in the wet place or the place exchange the interior lamp
which water splashes. lf earthingisnot done, it will cause of the refrigerator.
breakdown and electric shock. ;
@ Deterioration of insulation of electric © It may cause electric shock.
parts may cause electric shock or fire.

&.‘
(<>)
SS

|
/\ Caution
Do not put bottles or kinds of Do not store narrow and Do not store pharmaceutical
glass in the freezer. lengthy bottles or foods ina products, scientific materials,
small multi-purpose room. etc., in the refrigerator.
Freezing of the contents may inflict a elt may hurt you when refrigerator oThe products which temperature
wound. door is opened and closed resulting in control should not be stored in the
falling stuff down. ;

S
refrigerator.

Prohibition. {2 > >


S
uvwv° =, SsomoOSs a Prohibition,

Do noi store articles on the Use the rated components On repair, make sure that the
product. on the replacement. wires such as harness are
© Opening or closing the door may @ Check the correct model, rated bundled tightly.
cause things to fall down, with may voltage, rated current, operating © Bundle tightly wires in order not to
inflict a wound. temperature and so on. be detached by the external force and
then not to be wetted.

Prohibition (|

On repair, remove completely After repair, check the Check if there is any trace
dust or other things of assembled state of indicating the permeation
housing parts, harness parts, components. of water.
and check parts. elt must be in the same assembled olf there is that kind of trace, change
Cleaning may prevent the possible state when compared with the state the related components or do the
fire by tracking or short. before disassembly. necessary treatment
such as taping
using the
insulating tape.
3. Specifications of Electric Components

items Specification

Models - SR-S20..~SR-S22..
Freezing Capacity (4 STAR)
Model DK182Q-L2U
Compressor Starting type R.S.C.R
is
® Oil Charge FREOL ea - 15 (ESTER)
iss Freezer SPLIT FIN TYPE
2 Evaporator -
LY Refrigerator SPLIT FIN TYPE
S5 7
“. Condenser
7
Forced and natural convection type
,
a
5 Dryer Molecular sieve XH-9

Capillary tube 0.82 x 3000, 5.5 Kg/em@


Refrigerant HFC-134a
Temperature Selection ON(‘C) OFF(‘C)

eT
THERMISTOR :

8 ae -15.0
| / Model. :/| Temperature Selection ON(‘c) OFF(‘C)
5
=
a
LM
eee
a0 ee: 3
S| THERMSTOR ce a
= -| (RSENSOR) go: 4.0 2.0
Room ©
Temperature
Components
Sensor SQDAT 7c 8.0 6.0
‘@© | FistDeltost Cycle(Concurrent defrostofF andR) Ahr + 10min
Oo Defrost Cycle(FRE) = = 12 ~ 38 hr (vary according to the conditions used)
3= “vias Defrost Cycle(REF) = «=~ 6~19hr (vary according to the conditions used)
O.:- Pause time ete 40 +O min
Ss F Defrost- Model THERMISTOR (502AT)
s |. Sensor SPEC 5.0K) at 25°C
8 R Defrost Model THERMISTOR (502AT)
ra Sensor SPEC. 5.0K0 at 25°C
Defrost
Components
Related
Rated 2 s2..:. AC 250V 10A
| Thermal-Fuse
Operating temperature 72+4C
Items Specifications
Model SR-S2026, $2226] SR-S2027, $2227] SR-S2028, $2228 [SR-S2029, $2229
e SA-S2ONTC,S22NTC} SR-S20BTC, S22BTC |SR-S2ODTC,S22DTC |SA-S2OFTC. S22FTC
Defrost-Heater(FRE} Conducting a F Defrosting | _200 W : 200 W
DefrostHeaterPEF) —100w | 10
DRAIN HeaterFRE) 25 W 28
1
DISPENSER Heater - f= BW 5W
HOME-BAR Heater - 10W - | 10w
Thermal-Fuse for preventing
overheating of Freezer Defrost-Heater
AC 250V 10A 72+4C
Thermal-Fuse for preventing
overheating of Refrigerator Defrost-Heater

Compressor DK182Q-L2U
Condenser for ]Running| 350VAC-5¢F
a | (Package type) :
a J531035E330M3B5.2
| Starting-Relay -
g 33.0 +20%
S | Model ATMORSRFBYY-53
5 Over-load Relay 130 +5
iu 69 49°C

MOTOR-BLDC(FRE) 240V/50Hz UDQMOO2H4ASS


MOTOR-BLDC(REF) 240V/50H2z UDQMOO2H4ASS
MOTOR-BLDC (Circuit) 240V/50Hz UDOMOO2H4ASS
Lamp({FRE) AC240V/30W

Door Switch (HOME-BAR) AC250V 0.5A

BSBN (BRASS SCREW)


te ee
4. Circuit Diagram ;

For Basic & With Home Bar Models (SR-S2026, $2027, $2226, $2227/S20NTC,S20BTC,S22NTC,S22BTC) j

PANEL PCB MAIN PCB ogcpost-nearere


N
THERMO-FUSE,F ? b
a R ED 0 & |RED
Os FILT R
@ BLK]] [RED
S
& & |PNK P-CORD,R
wi
@ (BLU sptul > ICE MAKER HEATER
@ & lPpAP
Gg:
a
> IGRY
2 (WHT GAY] “1
@ & |seLu
@ 2 {waik
@ WED
a WIBLU OVERLOAD
PROTECTOR
® RED,
Pie As aes eS ne as cl
RED |p
@
D
NT
prep (RED)

EXT-SENSOR;—aa— ;

a ©3| | g FMOTOR(BL DIC).


{| Lo
BLK} tS RNOTORIEL DIC) wo
al C-MOTOR(BL D/C)

F-DOOR Siw
gets FSENSOR
r-0008 sw Leggs
BLK
2h 21s |ERT
71 RSENSOA RED
SW” R/DEF-SENSOR
ev

W/BLK F/LAMP. GRY

yet R/LAMP GRY |


a
Cry
Sy,
LS ano AP Oe cen cee ae ae IN,Sere

iReference:
Top ReeP eee

RED-RED WHT-WHITE
BLU-BLUE YEL-YELLOW
ORG-ORANGE BLK-BLACK
| P/BLU-PINK/BLUE PRP-PURPLE
BRN-BROWN W/BLK-WHITE/BLACK
PNK-PINK S/BLU-SKY/BLUE
GRY-GRAY E-EARTH
W/BLU-WHITE/BLUE W/RED-WHITE/RED
For Dispenser & With Home Bar Models (SR-S2028, $2029 $2228, $2229/S20DTC, S20FTC,S22DTC,S22F
TC)
eristeemniac easir EAN RATES OE NF TRON Oe meOE POR a AREER ESN ORM BL ERAN GREINER oy NORA EO

PANEL PCB MAIN PCB DEFROST-HEATER.F THERMO-FUSE


K 3

T
if&]
1 RED o\e——— E |reo
' 2 2. -
4 3 P-CORD.F DEFROSTHEATER.R THEAMo-FUSE.A| SED
t 4 VU BK np BUR] | __ [RED
|
:5 a
a
PCOKDR BLK R
ED EO
REC @eAe

Z
5 14-PIN
nis Cd
ff ICE MAKER PIPE HEATER OE
:
g E sau 274s yt :
& i RED
fi
z At
z OVEREOAD
PROTECTOR
REO
H RED! d
Sa
SR-S2029, $2229 . GRY
{CE-MAKER KIT -20FTC,S22FTC
1 7

! EecroTon DISPENSER SOLENOID


! asl, Lx
EJECT-SENSOR ICE SOLENOID
wet |_| ae
_
ees Coe = |
1 HORIZONTAL SW ¢+-—< pee RED
1 ICEFULLSW +0 : a
i AUGER-MOTOR |
ee a eee ICE CUBE SOLENOID |

EXT-SENSOR/—Gao— (D) a PJ] cryWATER-SOLENOID


VALVE —WATER-Sav
® 2
ices] Le} [o-8} @ /-—H “wOTOR|eL DE) BIK ee .
© |TLt RMOTORTELDT) — oy
GRY

F-DOOR SW
ad
o a, 4

POSIT Toe FSENSOR


BAS ,.
R-DOOR SW aA F/DEF-SENSOR | |: >
Moy old | BLK
2
2 a
3 RSENSOR ||
15 WIBLK _F/LAMP a GRY RED |
RLY
exp RIDEF-SENSOR ||

YeL_R/LAMP ey GAY

2Referencé3
RED-RED WHT-WHITE
| BLU-BLUE YEL-YELLOW |
ORG-ORANGE BLK-BLACK |
P/BLU-PINK/BLUE PRP-PURPLE
BRN-BROWN W/BLK-WHITE/BLACK
PNK-PINK S/BLU-SKY/BLUE
GRY-GRAY E-EARTH
W/BLU-WHITE/BLUE W/RED-WHITE/RED
5. Dimension & part name of refrigerator

5-1) Product Dimension (SR-S2026, $2027, $2226, $2227/S20NTC,S20BTC,S22NTC,S22BTC)

621.5

375.5
403

SR-S2027, $2227)
-S20BTC,S22BTC

SR-82026C, 52027C/S20NTC,S20BTC(D)

SR-S2026D, S2027D/S20NTC(D) S20BTC(D)


SR-S2226C, S2227CISZ2NTC, S22BTCID)
SR-S2226D, S2227D/S2NTC(D),S22BTC(D)
5-2) Product Dimension (SR-S2028, $2029, $2228, $2229/S20DTC,S20FTC,S22DTC,S22FTC) 2

521.5

403

(SR-S2029, $2229)
-S20FTC,S22FTC

SR.$2028C, $2029C/S20DTC, S20FTC(D)


$A-S2028D, $2029D!S200TC(D} S20FTC(D}
SR-$2228C, $2229CIS22DTC, S22FTCID)
SA.$22080, S22290'S200TC(D} S22FTCID)
5-3) Part Name (SR-S2026, $2226/S20NTC,S22NTC)
OO

FREEZER — . REFRIGERATOR --

© LAMP-INCANDESCENT @ COVER-GUARD
@ SHELF LAMP-INCANDESCENT
@ GUARD © SHELF
@® TRAY-ICE& ICE @ TRAY-CHILLED ROOM
© CASE-BASKET @ TRAY-EGG
© COVER-LEG, FRONT @ GUARD
® CASE-VEGETABLE

ti |
5-4) Part Name (SR-S2027, $2227/S20BTC,S22BTC) }

FREEZER” REFRIGERATOR”

@ LAMP-INCANDESCENT @ COVER-GUARD
@ SHELF LAMP-INCANDESCENT
@ GUARD ® SHELF
® TRAY-ICE & ICE @ TRAY-CHILLED ROOM
© CASE-BASKET @® TRAY-EGG
© COVER-LEG, FRONT @ GUARD
@® CASE-VEGETABLE
@® HOME-BAR
5-5) Part Name (SR-S2028, $2228/S20DTC,S22DTC)

FREEZER REFRIGERATOR

@ ICE-MAKER COVER-GUARD
@ ICE-CHUTE © SHELF-WINE
@ LAMP-INCANDESCENT @ LAMP-INCANDESCENT
® SHELF @ TRAY-CHILLED ROOM
© GUARD @® SHELF
© CASE-BASKET ® TRAY-EGG
@ COVER-LEG, FRONT @ GUARD
® CASE-VEGETABLE

:
5-6) Part Name (SR-S2029, $2229/S20FTC,S22FTC)

“J

REFRIGERATOR ©
@® ICE-MAKER COVER-GUARD
@ ICE-CHUTE @ SHELF-WINE
@ LAMP-INCANDESCENT @ LAMP-INCANDESCENT
@® SHELF @ TRAY-CHILLED ROOM
@ GUARD @ SHELF
© CASE-BASKET @ TRAY-EGG
@ COVER-LEG, FRONT ( GUARD
(@) CASE-VEGETABLE
(@ HOME-BAR
6. Freezing Cycle & Cold Air Circulation Course in Refrigerator

6-1) Freezing Cycle


rc

COMPRESSOR — WIRE-COND — SIDE CLUSTER PIPE - HOT PIPE ~ DRYER


— CAPILLARY TUBE— REFRIGERATOR EVAPORATOR— FREEZER EVAPORATOR
— ACCUMULATOR— SUCTION PIPE - COMPRESSOR

REFRIGERATOR EVAPORATOR
SIDE CLUSTER PIPE

ae 7 ee
Pe ' %
eee | SS.

Pa | Tee

ann ee =
PO

ee |
ACCUMULATOR 7 f _

~ a"

“ i
| |

| SUCTION PIPE — eee |


ee . Hor-piPH
FREEZER ee ;
EVAPORATOR a
COMPRESSOR
WIRE-CONDENSER] |
6-2) Cold Air Circulation Course in Refrigerator (Cold Air Passage Circulation Course) aewee!

"REFRIGERATOR
7. Function & Operating Instruction of Refrigerator

7-2) Temperature Control Function )

1) Basic and with Home Bar Models

FREEZER REFRIGERATOR

papa
Kiki

REFRIGERATOR

a a om
IZHZI

7-2) Temperature Control Function )


® Temperature selecting function of freezer
1) At initial Power On, -20°C is selected automatically.
2) Select one button for 13 levels of -14°C ~-26°C.
3) 1°C drops per each pressing of temperature selection button of freezer.

Display
Change

@ Temperature selecting function of Refrigerator


1) At initial Power On, 3°C is selected automatically.
2) Select one button for 9 levels of 7°C ~-1°C.
3) 1°C drops per each pressing of temperature selection button of Refrigerator.

Division | Atintial — One Time Press . 4 Times


Smee 5 TimesPress a8 TimesPress

IC 4
Display aa
Change - |

* Reference (terms explanation)


1)F Room: freezer 2) R Room: Refrigerator 3) F-FAN: fan motor in
freezer 4) R-FAN: fan motor in Refrigerator 5) COMP: compressor
* Reference
Temperature of table on previous page is temperature of center part of
1/3 height of Refrigerator/Freezer compartments. It is temperature data at
unload state. When actually used, temperature may differ according to
surrounding condition and use frequency. The table displays general
characteristic of temperature.

7-3) Function of Quick Freeze & Vacation ,

@ Select extra Quick Freeze & Vacation button.


@ Whenever Quick Freeze & Vacation button is pressed, selection/ cancellation
(corresponding lamp On/Off) is repeated.
@ When Quick Freeze & Vacation is selected, temperature setup of freezer and
Refrigerator does not change.
@ Atstate of selecting Quick Freeze & Vacation, change of temperature setup of freezer
and Refrigerator is possible.
@ Quick Freeze Function
1) When Quick Freeze function is selected, COMP and F-FAN operates
continuously for 2 and haif hours.
2) While Quick Freeze function is working, Refrigerator operates under
present setup condition.
3) When Quick Freeze function is completed (after continuous operation of
COMP, F-FAN for 2 and half hours), Quick Freeze lamp lights out
automatically and operates according to setup temperature of freezer.
@ Vacation Function
1) When Vacation is selected, Refrigerator fan is turned off.
2) Though Vacation function is selected, Refrigerator fan does not turned off
but turned on for initial 5 minutes.
3) When Vacation function is selected and Ice Timer is set, Vacation function
completes automatically when Ice Maker works by Ice Timer function.
Then Refrigerator fan operates according to temperature setup of
Refrigerator. (explained in detail at |ce Timer function)
4) Vacation function is selected/ canceled by Vacation button. It can be
canceled by temperature control button of Refrigerator while Vacation function
is selected.
5) While Vacation function is working, Vacation lamp is ON, and temperature
display of Refrigerator is OFF.

* Reference
If Quick Freeze function is selected when freezer temperature is over -10°C
and Refrigerator temperature is over +10°C like the condition of initial
Power ON, Refrigerator Fan becomes OFF until freezer temperature
drops under certain temperature. When freezer temperature becomes
under certain temperature, Refrigerator Fan operates.
7-4) Alarm Function

® Button Touch Sound (“Ding-Dong” Sound)


1) Input confirmation sound of “Ding-Dong” sounds when each button of
Control Panel is pressed.
2) “Ding-Dong” doesn’t sound if more than two keys are pressed at the
same time or buttons are wrongly operated.

@ Door-Open Alarm Sound (“Ding-Dong” Sound)


1) If door of freezer or Refrigerator remains open over 2 minutes, alarm
sounds ten times.
2) If door remains open continually afterward, alarm repeats ten times per one minute
cycle.
3) Alarm stops immediately when door of freezer or Refrigerator is closed.

® Forced Operation & Forced Defrost Alarm Sound (“Beep” Sound)


1) If forced operation or forced defrost is selected, “Beep” sound occurs.
2) If forced operation is selected, alarm sound occurs until automatic
cancellation (after 24 hour’s forced operation) or cancellation function is
selected.
3) Also in case of forced defrost, alarm sound occurs until defrost is
completed (including pause) or cancellation function is selected.

7-5) Defrost Function )

® At time of initial Power On, defrost function works for both freezer and Refrigerator at
the same time, when integrating time of Comp On is over 4 hours.
@ Afterward defrost cycle is changeable according to use condition or surrounding
environment from 6 hrs. to 38 hrs..
@ After completing the initial defrost, PRE-COOL function works for 20 min. to minimize
temperature increase by defrost work. However, PRE-COOL function is determined
according to temperature in Refrigerator at the point of defrost time.
® If F-room temperature is over -21°C, PRE-COOL function works for F-room. If F room
temperature is below -21°C, PRE-COOL function does not work.
7-6) Test Function
Ree Sabet ee a ee PS i Pe TE

@ Test function is for test, process inspection and SVC of PCB and product.
e After selecting test S/W and confirming function of product, turn on power switch
again to operate self-inspection function.
® if you press Quick Freezer Key on Display Panel and temperature control Key in
R-room for more than 8 seconds, all Displays will be turned off and continue
operating in Test Mode. At this moment, if any key is pressed among freezer
temperature control key, Refrigerator temperature control key, quick freeze key or
vacation key, it operates as the test button. ,
+ F-room : Freezer, R room : Refrigerator

@® Forced Operating Function


1) In the state where display panel was converted into test mode, if test button
is selected once, COMP will operate immediately without 5 minute
delay function. Therefore, forced operation is conducted at the very moment
of COMP OFF, over load may be caused. Please be careful.
2) If forced operation is selected, freezer and Refrigerator is set to automatic,
and the temperature of freezer is set to “-26°C” and Refrigerator is set to
“14°C”, Comp and F-fan operates continuously, and R-fan in Refrigerator is
controlled by “1°C” setup.
3) Forced operation is valid for 24hrs. That is, if 24hours. pass after
selecting forced operation, simultaneous defrost in both Refrigerator and
freezer is automatically carried out. And normal operation is carried out
by present setup of Refrigerator and freezer.
4) Cancellation of forced operation in the middle of working is possible by
turning on Power after turning it off (resetting), or by selecting test cancel
mode shown in the item 3 below.
5) When forced operation works, alarm sound will continue until forced
operation is completed. There is no alarm cancel function.

@ Forced Defrost Function


1) In the state of forced operation, if display panel is converted into test mode and
press the test button once more, forced operation is cancelled immediately,
and evaporator defrost function of Refrigerator operates.
2) At this time, beep alarm sounds for 3sec. at the point of defrost, and
0.75sec. ON/0.25sec. off sound occurs during forced defrost function
of Refrigerator works.
3) If above defrost function of Refrigerator is maintained, it operates normally
after defrost is completed.
4) While forced defrost function of Refrigerator operates, pressing the test
button once more enables simultaneous defrost for both freezer and
Refrigerator.
5) At this time, beep alarm also sounds for 3sec. at the point of defrost, and
0.75sec. ON/ 0.25sec. off sound occurs continually until simultaneous
defrost of F and R is completed.

@® Test Cancel Mode


1) In the state of simultaneous defrost of freezer and Refrigerator, if display panel
is converted into test mode, and test button is pressed once more, defrost
of both freezer and Refrigeration is cancelled immediately and resumes
normal operation .

%* Reference
It works step by step in test function. It does not change from 1 step
(forced operation) to 4 step (test cancel mode) directly. It operates
corresponding function only after it goes through the previous step. While
test function works, it is most desirable to turn off main power and then turn it on.
7-7) Self-diagnosis Function _,

® Self-diagnosis Function at the time of initial power is on.


1) When the initial power is applied to Refrigerator, all lamps light and conduct
self-diagnosis function internally.
2) If result shows no fault, display will go into the initial normal lighting state.
3) If result shows any fault, corresponding led is turned on and off and alarm :
sounds.
4) Error sign of self-diagnosis continues until all defects of parts are repaired
or self-checkup function is cancelled.
5) If all corresponding parts are repaired completely, display will go into the
normal mode state.
6) After repairing Refrigerator, turn on switch again after turning it off to
make it sure if Refrigerator is properly repaired.
7) Therefore, in case open & short related problem of sensor needs to be
confirmed during A/S, turn off the power of Refrigerator and turned it on
again to operate self-Diagnosis function. Then sensor function can be
checked.
8) When any defect occurs, corresponding display signs are shown as in the
following chart.

[nol Items Corresponding LED Defect Content

ICE-MAKER REFRIGERATOR Defect of wire connecting system due 0 |when temperature sensing of R-
badness
Ste ofet
Oper/Short
rhea related aspect of . 7
sensor is more than +50°C and less
SENSOR Sensor which isequipped at the
than -50°C
;
a YS beneath of ice-making bowl :
: ; REFRIGERATOR Missing sensor housing of R-room, Defect is indicated when temperature
palsy ry 4 contact defects, disconnection of wires, | sensing of R-sensor is more than +50
“Sensor defect of short-circuit sensor itself, etc. | ‘C and less than -50°C.

Retrigerator ’ REFRIGERATOR Missing sensor housing of R-room, —_{Defect is indicated when temperature
defrost i)
mi contact defects, disconnection of wires, |sensing of R-sensor is more than +50°C
elrost Sensor ( defect of short-circuit sensor itself, etc. |and less than -50°C.
SS

: REFRIGERATOR Interference of Fan due to frost, etc., [Occurrence of the case where Fan Motor of
a4 Ran motor mt et ccia pebsee 108 ers Jinner fefrigerator room becomes to operate
Error mi 4 : . : under about 600rpm at the normal operation
20 UL disconnection, etc. condition or stops driving,
a
ICE-MAKER GEEROEne Defect of micro SMW in Gear box, When normal operation is not done until ice-
05 pm po motor, gear and other defect in wire _| isolating motion is attempted 3 times (only
KIT )_G L! system ice-making function model corresponds).
Outside Air om a eae elt
lyseleit Badness is indicated when temperature sensing
06 f : Liha : xs of Outside Air Sensor is more than +50°C and
Sensor f 4 disconnection
ofwires,defect of short-circuit sensor less than -50°C.
< itseff, etc.
Freezer FREEZER Missing sensor housing in F-room, | Defect is indicated when temperature
4 contact defects, disconnection of wires, |sensing g of F-sensor is more than +50°C
F- <> 7
Sensor JU defect of short-circuit sensor itself, etc. |and less than -50'C.
te
——|
FREEZER Missing defrost-sensor housinginevaporator of | Defect is indicated when temperature
08 Freezer mi im F- room, contact defects, disconnection of wires,! sensing of F-sensor is more than +50°C
defrost-sensor im( y_t delect of short-circuit sensoritself,etc .
|and fess than -50'C.
| F-fan motor FRE eZee Interference of Fan due to frost, etc., {Occurence of the case where Fan Motor of inner freezer
09 pim me un-insertion of connector, roort becomes to operate under about 600rpm at the
[ Error (me disconnection, etc. normal operation condition or stops driving.
C-fan motor FR EEZER Ps ct |Genneeesof the case where Comp Cooling Fan
10 im mG co Motor becomes to operate under about 600rpm al
Error mi imif et [tenormal operation condition or stops driving,
Note) This self-Diagnosis works only when the oper/short related aspect of sensor is bad. Minute
feature change of sensor is not judged as defect if it does not get rid of the extent of temperature
sensor described in Remark so that it is indicated as normal.
®@ Self-Diagnosis Function in Normal Operation
1) Under normal operation of Refrigerator, if you press “Quick freeze” and
“Vacation” button at the same time for 6sec., temperature setup display
will proceed On/Off blink of all for 2sec. at 0.5sec. interval.
If you press “Quick freeze” and “Vacation” button continuously at the
same time for about 8sec. including 2sec. of repetition of LED’ s On/Off,
self-Diagnosis function is selected.
2) At this moment, it goes into self-Diagnosis function with “Ding-dong”
buzzer sound.
3) When Error occurs, it is restored to normal state regardless of defect
repairing after signal lasts for 30sec. (“Ding-dong” buzzer sound).
4) While it is operating self-Diagnosis function, it does not accept input of
button.

7-8) Load Condition Indicating Function }


® In normal operation, if you press “Quick freeze” and “Vacation” button
at the same time for 6 sec., all setup display of freezer and Refrigerator
are turned on. If you hand off from the button at this moment, temperature
setup display of freezer and Refrigerator will proceed On/Off blink of all for
2sec. at 0.5sec. interval. While On/Off blink is processing, if you press the
temperature setup button, it goes into load condition indicating function
(with ding-dong buzzer sound).
@ Load condition indicating mode shows from which load Micom signal
outputs at present. However, it only shows that micom signal is outputted
and does not confirm whether load is actually operating or not. That is,
even if load is displayed as it is operating, load may not operate because
of actual defect of load or defect of relay on PCB. During A/S, you can
use this function by applying the main function.
® Time required to indicate is 30 sec.. After 30sec., it is automatically
restored to the setup state before its function.
@ Corresponding display indication about load condition is shown as in the
following table.

* Load Mode Check List

NO} Display Content Operation Content Press both buttons 6sec, simultaneously, all LED lights are
turned on and off twice.
@ |R-fan high R-fan high speed operation indication At this time press button @.
R-fan low R-fan low speed operation indication gece
‘|R-Dei-Heater R room deftost-heater operation indication
|
Start Mode indication operation stage (Not important) O FREEZER REFRIGERATOR | O
Overload Mode when ambient temperature is more than 34°C @ ® |
Low-temperature Mode Ther ambient temperature isless than 17°C | Oli ®
| Comp Comp operation indication Opt ® Ont ®
F-fan high | F-fan high-speed operation indication O ® i) O
F-fan low F-fan low-speed operation indication +
F-Def-Heater F room defrost-heater operation indication a
C-fan high C-fan high-speed rotation operation indication * For load under operation, corresponding LED lights on.
C-fan low C-fan low-speed rotation operation indication
7-9) Function of Ice/Water Dispenser when they are equipped. }
SO PR RNR RENE UR aoe

@ This function only applies to a model equipped with ice-maker.


@ This function is limited to a model from which ice and water can be taken out
from outside without opening door.

@ Cube Ice / Crushed Ice/ Stop (Off) Function


1) At the time of intial power on, when inside temperature of freezer is more than 5°C,
Cube Ice LED light on display is lit on, and Crushed Ice LED light keeps light-off
state. But when power is turned on, if inside temperature of freezer is less than 5‘C,
Micom recalls form of ice which was set up before power off so that it displays the
memorized ice form. .
2) “Cube” — “Crushed” — “Ice Off’ is selected in turn by ice selecting Key.
3) In case of selecting “Crushed” mode, it operates Gear Motor to eject crushed ice
to outside when ice lever operates as ice is made in the bowl of ice machine.
4) In case of selecting “Cube” mode, Gear Motor and ice solenoid operate to eject
cube ice to the outside when.ice lever operates as ice is made in the vessel of
ice machine.
5) If “Ice Off” is selected, it stops only ice-making function of ice-maker so
that ice is not made.
@ At the moment of selecting “Ice Off’, ice-making function stops. But, if it is in
the process of ice-isolating, returning to horizontal state and supplying
water, it maintains stoppage state after water supply is completed.
@ Even when “Ice-Off" function is operating, ice eject lever operates normally.
This is not a defect. Therefore, remained ice in the ice container can be used
normally.

© Ice Timer Function


1) If you press ice timer button, it is automatically set to Ice-Off mode regardless of
present setup condition of ice mode (Cube / Crushed / Ice Off), and ice lamp is
turned on. And time is set to 3 days on temperature control display of freezer at first.
And each time you press the ice button, the number increases one by one. And if it
reaches 30 days, it resumes from 3 days.
2) Among ice timer functions, if you press ice selecting key, ice timer function
is cancelled.
3) If reservation is made by ice timer button, setup temperature of freezer returns to
temperature display of freezer after S5sec.. At this moment, if ice timer button is
pressed again, it displays the previous reserved date again.1-2 days before the
reserved date is completed, ice maker starts operating. And when the reserved date
is completed, more than half of ice bucket is filled.
4) If ice timer is reserved and vacation function operates, vacation function
ends at the same time when ice timer function ends.
5) The following are examples for use.
in case of selecting vacation function only
If you press “vacation” button, Refrigerator will not operate and freezer will operate
only. In case you Select this function, take out all foods in the Refrigerator. And “ice
Off” is automatically selected among ice modes, so ice bucket should be empty and
water supply valve should be turned off.
In case of selecting ice timer function only
In case you press “Ice Timer” button to select date as explained above, and not
selecting “Vacation” function so that Refrigerator continues to operate, ice mode is
selected as “Ice Off” and ice is stored in the bucket when you return. Therefore, do
not lock the water supply valve.
In case of selecting both vacation and ice timer function
In case you press “Ice Timer” button and “Ice Timer” button to select date to select
date as explained above, or if you press “Ice Timer” button to select date and press
“Vacation” button afterward, Refrigerator does not operate but freezer operates only,
and ice mode is automatically selected as “ice Off”. So you must take out all foods in
Refrigerator, empty ice in the ice bucket, check water leakage on valves, other hoses
and connection parts without locking water supply valve. When “Vacation” function is
cancelled, Refrigerator resumes its operation.

@ Ice Dispenser Function (Cover Ice Route Solenoid Valve)


1) After 8sec. from initiai power on, solencid of ice exit operates once. This is the
function to prevent interruption of electric service when ice exit is open. So this is not
a defect.
2) With turning the dispenser S/W from on to off and ice ejecting is
completed, 5sec. after turning off S/W, ice exit is closed because. cover ice
route solenoid of ice dispenser operates.

@ Water Dispenser Function


1) This function is a system of direct connection with water supply. When water lever is
pressed, water solenoid valve which is equipped at the right side of machine room
opens so as to operate to eject water. However, it has no function to conirol on
Micom PCB. Therefore, if there happens any defect at water eject function, check
and repair solenoid itself, wire connecting connector, connecting tube and state of
water supply.

©) Water Filter Indicator Function


1) After the initial power on, indication lamp is displayed in green light. After 5 months
passed, it is displayed in orange light, and 1 month after this, it is displayed in red
light. This is memorized by EEPROM in Micom PCB, so it counts the passed time
continually though the power is turned on again after it was turned off.
2) If you press ice selecting button and ice-making stop button at the same time for
25sec. continuously, indication lamp lights in green color. And it becomes orange
after 5 months from this moment. And it displays red after 1 month from the
moment.
3) If you press ice selecting button and ice-making stop button at the same time for 5
sec., indication lamp is turned off and water filter indicator function stops. At this
moment, passed time is not counted.
4) At the state where the function is stopped, if you press ice selecting button and ice-
making stop button at the same time for 25sec. continuously, “Green” light is turned
on and water filter indicator function will resume. And it becomes orange light after 5
months from this moment. And it displays red light after 1 month from the moment.
7-10) Restoring Function of Operation State in case of Power Stoppage )
1) In case power is applied to prevent customer from nonsense call about
initialization of freezer and Refrigerator at -20°C and 3°C respectively when
a momentary power stoppage (not a long-term power stoppage) occurs
while Refrigerator is operating, it operates in two ways. The first one is
initialization by judging the temperature of inside of freezer, and the second
one is restoration of operation state.
2) At the initial power on, in case temperature of the inside of freezer is
judged as about less than +5°C, it is regarded as momentary power
stoppage during operation. Therefore, functions related with panel display
such as Quick Freeze, Vacation, Freezer setup, Refrigerator setup, Ice
timer, Form of ice, etc. are restored.
3) At the initial power on, in case temperature of the inside of freezer is about
more than +5°C, it is regarded as long-term power stoppage: In this case,
panel display is initialized (Quick off, Vacation off, Freezer is set to -20°C,
Refrigerator is set to 3°C, Ice timer off, Cube selecting).
4) Ice timer function and water filter indication function are not initialized in
case of power stoppage. But during power stoppage, time count does not
progress because Micom in PCB does not operate because power source is
not supplied.
8. Operation Principle of Circuit

8-1) Power Source Part

When power is supplied, electric wave is rectified through BD1 to generate voltage of
about DC 300V.Top S/W is automatically switched to the optimum condition according to
load condition of the second part.
When electricity flows between D and S of the top S/W, electricity is generated inside
the trans, and wnen the power between D and S is turned off, electricity which is
deserted at trans is transmitted to the second part.
This process is repeated to maintain the fixed voltage of 12V by C102 of the second
part. This power supplies electricity to power source of 5V, relay and display, and it
allows operation of main PCB possible.
8-2) Oscillation Circuit Part

Terminal Oscillation Frequency

Xout(#31)

Itis oscillation circuit for synchronism clock generation and time calculation on
information sending/receiving of internal elements. It does not carry out its normal
function because timing system of MICOM alters in case the specification of resonator
changes.

8-3) Reset Circuit Part )

M ;
| | Terminal | Voltage |

| C Vee DC 5V
O
M RESET | DC SV

Reset circuit is a circuit which allows the whole program operate on an initial
position by initializing several parts such as RAM inside of MICOM when power is
applied to MICOM. When power is supplied, the reset terminal voltage becomes
several tens us “LOW” state compared with Vcc voltage (DC 5V) of MICOM, and it
maintains “HIGH” (Vcc voltage) state in normal operation condition.
8-4) Door S/W Sensing Circuit

Terminal Voltage MICO’?

DOOR CLOSE | 5V (HIGH:

DOOR OPEN OV (LOWI

DOOR CLOSE | OV (LOW!


R-Room = ee
DOOR OPEN 5V (HIGH!

For door open sensing of F room, ® of CN30 is connected to the ground. For @, Vec(DC
5V) is supplied through resistance R404(4.7K), and “LOW” (OV)/" HIGH(5V) is applied to
MICOM by open/close of the F room door so that it can sense open/close of the F room
door. For door open sensing of R room, © of CN30 is connected to the ground. For ©,
Vec(DC 5V) is supplied through resistance R403(4.7K0), and “LOW” (OV)/” HIGH(5V) is
applied to MICOM by open/close of the R room door so that it can sense open/close of
the R room door. At this time, if there is any defect at the door S/W, the corresponding
fan inside the Refrigerator does not work or alarming function works. Therefore, the door
S/W must be checked in case of A/S. That is, if door opens, the corresponding fan inside
the Refrigerator stops without fail. When connection point of S/W has defect, MICOM
judges that door is open so that it stops the fan though the door is closed.

8-5) Temperature Sensing Circuit Part )

pe )
FSENSOR *-CVMS $ =
ee
a Wi TS MICOM terminal Voltage |
FDEF SENSOR -eap~101 eS WwWToei PIX. =56 (F-SENSOR) iow !
marr eee se : [PI #37 (F-DEF-SENSOA ly |
es le ter 7 . PIN. =58 (R-SENSOR) shanti
= he : PIN =9 (R-DEF-SENSOR) i
pe aaa ~ Weige Ph =40 (ExTSENSOR)
ie
Sensor uses thermistor which has temperature coefficient of negative resistance. When
temperature rises, resistance value gets smaller, and when temperature falls, resistance
value gets larger. R306~R310, C301~C3085 are parts for noise prevention, which are not
related to temperature sensing characteristic. In case of F-SENSOR, if setup voltage
inputted to MICOM Referred to as Vf, Vf= (Rth*Vcc)/(R303+Rth). Here, Rth is
resistance value of thermistor corresponding to temperature. See conversion table of
“Refer 6” of this manual on resistance and voltage of sensor about temperature for
Reference. As terminal voltage of MICOM corresponding to temperature is also
designated, Refer to it at A/S time.
8-6) Key Scan & Display Circuit Part

PANEL PCB

@ Key Scan and Display Operation


As is seen on each wave form of the following, send “HIGH” output in an
order of MICOM PIN NO #3—-#4—-#5—#6—#7—#8 for 2msec in a cycle
of 12msec using six terminals of MICOM NO #3, 4, 5, 6, 7, 8. This signal
appears onto output terminal through input terminal of ICO5(UDN2981 or
KID65783AP). At this time, peak-to-peak voltage of the spherical wave is
about 11V(DC RMS1.5), and form of output wave form is like the drawing 1.

Mog \ 10msec \
V bute la as3
GRID #1 [rv

VIG i
GRID#2 | | | ; | ||

GRID #3
Ce bs 4
r] ae 7] |

Vel ae oe ai ; |
GRID#4 | ' 3 | ||

GRID#S a| i toi cae 7 7

@) Key Scan
When the wave form of GRID#2 is outputted, this signal is provided to SW6 button
through the resistance of 10K0. When SW6 is pressed at this time, signal gets smaller
by R501(12k2), and about 4.5V of peak-to-peak voltage is applied to MICOM.
MICOM judges that the wave form of GRID#1 is inputted, and changes function
corresponding to SW6 KEY. In this way, each wave form of GRID is recognized.
8-7) Load Operation Circuit Part

L
waldo
oz

¢
RED fax
OE:
EATER
£
GAN

RO, —aa BLK [ARSENE GRY

BLK|er — ee L

[ICE WAKER PIPE HEATER)

es<a o)
: [oseecnenta”H
DISPENSER HEATER S/W
BLK:
Ga WRK
®

aes
PRP
ICE SOLENOD-VALYE

Faw

AUCER MOTOR
On®
‘CUBE SOLENOID

When “HIGH” signal is applied to INPUT terminal of ICO3(KID65003AP) from MICOM


PIN NO #16(P07), IC is turned on. At this time, V12(DC12V) which is applied to the one
terminal of coil of COMP relay flows to ground through output of ICO3. Then core
generates magnetic field to turn on the connection point, and it applies voltage of 230V
to COMP foad to turn on COMP. When MICOM PIN NO #16 changes to “LOW” state,
electricity cannot flow to COMP relay coil because IC is turned off. So relay connection
point becomes to OFF state and stops COMP.
@ COMP & F,R Defrost Heater Inter-operation Explanation

COMP RELAY

Like the above block diagram, operation of F, R defrost heater is determined according
to the operation of relay for COMP. When COMP relay is connected to NO terminal,
COMP operates. However, in case of F, R defrost heater, electricity does not pass
through the heater though relay works. But, if COMP relay is connected to MC terminal,
COMP does not operate and heater gets electricity according to operation of F, R
defrost relay.
* Purpose of application of above circuit: It aims to interrupt electricity passage through
F, R defrost heater even though F, R defrost relay is bad while COMP is operating.
8-8) BLDC Motor Operation Circuit Part }

ee Sasa wh
BLOC FAN MOTOR

ae
BLOC F-FAN

| ee
VS tb ot
7D703 2702 D7

a In case Fan Motor is locked, therefore, when Fan Motor is constrained to less than
about 600rpm in order to prevent over-current to the power source group, PIN #39,
#38 and #37 sense it so that they can stop Fan Motor operation.
If Fan Motor operation is stopped by this function, it becomes to re-operate every 10
second. If Motor Connector is separated under the state where the power source is
applied during service, Micom recognizes it as Fan Mctor is constrained so ihat
Micom can stop Motor. Then Motor resumes to operate afier 10 seconds.
However, there are a part of products which re-operate every aboui 5 minute among
the products which were manufactured in February and March.
Therefore, when the product is completely repaired, confirm the repaired state with
power-ON again after power-OFF if possible.
8-9) Various Option Function )

m When pressing the temperature control s/w of freezer and vacation s/w for 12 sec.
continuously at the same time, display is converted into option setup mode.
When display is converted into option setup mode, every display except for
temperature display of freezer and Refrigerator turns off like the following.

REFRIGERATOR

rite

= On display like the above, temperature display of Refrigerator indicates items of


option, and temperature display of freezer indicates setup value for each
item.For the temperature display of Refrigerator, when temperature control s/w is
pressed, option items increase, and when vacation s/w is pressed, option items
decrease. For the temperature display of freezer, when temperature control s/w
is pressed, option setup value increases, and when vacation s/w is pressed,
option setup value decreases. If waiting for 20sec. after changing option by
controlling s/w, option setup value is saved to EEPROM, and option setup mode
is canceled automatically and restored hormal display. For example, if you want
to shift temperature of Refrigerator by -3°C by controlling option, follow the
processes of below. =

1) Press temperature control s/w and vacation s/w of freezer for more than
12 sec. simultaneously : all displays become off except temperature
display of freezer and Refrigerator.
2) Pressing temperature control s/w of Refrigerator for one time, “1” is
indicated on Refrigerator display : If indication “1” is displayed on
Refrigerator display, it shows temperature setup of Refrigerator, and
current temperature setup value of Refrigerator is indicated on
temperature display of freezer.
3) If temperature display of freezer indicates “9” this time, check value
which is set at present from the table in the next page. In this case,
you can see that temperature is changed to +1.0°C compared to the
Standard temperature according to the table : Here, in order to change
by -3.0°C, (+1.0°C) + (-3°C) = -2.0°C is calculated.
4) Now Refer to the table on the next page to change temperature to
-2°C.. Press temperature s/w and quick freeze s/w of freezer for
temperature control display to indicate “4”: Waiting for 20sec. after
setup, MICOM saves setup value to EEPROM and returns to the
normal display and cancel option setup mode.

* Caution
When product is delivered, option function is set to EEPROM from the plant,
therefore, Refrain from intentional change except for special case. Option
function setup is completed only after it is returned to the normal display after
20sec.. So do not turn power off before display returns to the normal state.
8-10) Option Related to Temperature }

m= Freezer Temperature Change Table @® Example


: , , - When set to -2.5°C, compared with the standard
Set item | Refrigerator display | temperature of freezer

al
Freezer temperature g i FREEZER REFRIGERATOR

0” |
i

change mode

Temperature change Freezer display Temperature change Freezer display

- 10°C | ta | + 15°C Bice |


Q -15C | 3" | + 20 “ie
| - 20°C “4” | + 25°C | "12"
- 25°C | es | + 30°C aes |
30°Ca ee] ‘6 [ + asc 14" |
;

- 850 ! oe [tao "18"

m= Refrigerator Temperature Change Table( @: corresponding lamp is on,


@: corresponding lamp is off)

@ Example
- When set to +2.5°C, compared with the
Set item Refrigerator display standard temperature of Refrigerator

Refrigerator temperature “yn | ee i)


change mode | uF {
CN a }

Temperature change Freezer display | Temperature change | Freezer display


0 | ‘o” | + 05°C ‘g”
| 05 ea | + 10°C “Q"
- 10°C | Z | + 15 “10” |
= 15 | nc | + 20°C a
- 20°C ! “ar | + 280 "12° !
ee | ‘Sr | + 30°C “13” |
LE - 30°C | ‘6° | + 35°C "14" :
- 35°C | 7 | + 40°C "45" i
8-11) Option Related with Ice Maker )

# Following options are applied only for models which are equipped with ice maker.

u Itis water supply time option that operates


when the flow sensor for time control « Itis the temperature of ice making sensor
function of water-supply for ice maker is out which checks whether the ice of ice-maker of
of order (identical with DIP s/w of existent temperature change of ice making sensor
ZIPEL). freezes completely.
Set item Refrigerator display Set item Refrigerator display ”
Ice maker water supply time Ice making temperature
Water supply time Freezer display Temperature change Freezer display
7C 0

ead

. oF

4"

@ Example
- When ice making sensor is set to -10°C
“ 11 n

FREEZER REFRIGERATOR

19sec ay ut |
“a 13”
( (

u When Refrigerator temperature display indicates “2”,


the data indicated on the freezer temperature display is
the function which is not used in this model so that @ Example
additional adjustment is not necessary. - When water supply time is set to 9sec.
u lf Refrigerator temperature display is not selected

5 UU 3
FREEZER REFRIGERATOR

more than “2” during option function is setting among


models which are equipped with dispenser and ice-
maker, replace the main PCB assembly.

Note: If Refrigerator temperature control s/w and vacation sw are used, several other options except the
above functions are set. However, those points are omitted because they are not necessary part at the
A/S time as they are items related with Refrigerator control function (Do not set options other than the
above A/S manual contents).
9. Trouble Diagnosis & Repair Method

1. Check whether power cord is normally connected before repairs.


2. Practice checkup on the basis of Reference in the next page.

230V AC FUSE
Disconnection?

* power cord terminal connection Replace FUSE

Check cord assembly


connection.
is voltage abou!
DC 320V applied to both
BD1+terminals ?
; Replace PCB pattern
>< Caution and BD1.
As high pressure current more
than DC300Vgenerates on the Sssage DC5.8
power part of main PCB, take applied between, top s/w
great care in case of checkup 223Y ‘C-S ?
and measurement. Replace PCB
assembly.
s voltage 12 N
applied to both terminals

Replace D104(D105)
(S3L20U)(D10SC9M)
Is voltage 5V
applied to both terminals
of C1032
Replace REG1 (7805).

Does panel PCB


’ operate normally?

xlead wire cable, door (connect ® ae ae assembly


at HINGE-UP part) @ Replace panel PCB
Does {oad of relay
and so forth operate
normally ? Y
@ Replace the
corresponding relay
@ Check connection of
lead wire
1. When power is applied initially, COMP works after 3~6 sec.. However, when COMP turns off during
its operation, COMP doesn’ t work for Smin..
2. COMP doesn’ t work during defrost
3. If freezer sensor is not connected, itis sensed as low temperature and COMP doesn’ twork.

Check after 5 min.

Does COMP
drive at forced
operation?

Is freezer sensor
Is MICOM #1501 normal?
HIGH applied?(5V Y Repair open and
connection state

ls temperature ~ N
sensor of main PCB is
Is C03 #14 LOW normal?
applied?(0V - Repair sensing part
and replace PCB
Replace IC03 and repair Control cord and repair

=
connection state
Replace COMP relay
and repair

Replace COMP RELAY

!s contact state of
Connector CN70, CN71
is normal?
Complete insertion of
Connector

Replace COMP ASS’ Y


and repair
[corAssembly and Connection Stat
1. At the initial power on, cooling operation is normally carried out. However, after a certain time
passes (when defrost time comes), badness occurs on Refrigerating and freezing work. It is
a case where there is defect on defrost part. Checkout whether there is defect on defrost
system by Referring this trouble diagnosis.

x Refer to 7-7 self-diagnosis


function of main function.

A Is F, R defrost
ay inwok sensor normal by
self-diagnosis?
Replace and repair the
corresponding sensor
Is F, R defrost
poe heater normal by
v elf-diagnosis?
« Refer to load defect checkup on Check temperature fuse, heater
this manual Ref 3. itself, cord disconnection, cord
contact state
Is temperature
of corresponding defrost sensor
Y below -5°C?

x Judge in accordance with Ref 4


and Ref 8 on this manual.

Perform forced defrost for F and R


oe simultaneously.
y
x Refer to 7-6) test function of the
main function.
Is power applied
to each defrost heater?

Reference

1. Ifeach EVA-SENSOR of F room and R room has open or short-related defect, electricity
does not flow to defrost heater and it returns to normal operation after pause time passes.
Therefore, if the period when defrost heater does not work accumulates, Refrigerating and
freezing badness results.
2. If temperature fuse which is a safety device is turned off, or defrost heater has wire
disconnection, or relay on PCB is bad, defrost is done by natural temperature rise. In this
case, period of COMP off according to defrost becomes very long so that badness on
Refrigerating and freezing function results. |
N Does it return to
old operation after heating fo’
Y certain time?
Recheck troubles of corresponding
sensor that does not return.

| Normal
x When temperature of F, R
defrost sensor reach more than +5'°C
and +15°C by heating, terminate
heating and convert into cooling (8)
operation after pause.

Is connection terminal
of MAIN-PCB part normal?.

Repair connection terminal


Check troubles on corresponding
defrost heater relay, badness of PCB,
and defect on normal/close terminal
connection of COMP RELAY.
« Refer to load operation circuit
part and checkup method on
Replace and repair bad relay or relay defect on Ref 2
replace PCB ASS’ Y
9-4) Self-diagnosis Abnormality Occurs )
ATELY NTL ID LCE ILE PEPE TES ARE GE EEEMT IERIE OEE ADSI

@ When abnormality on outer temperature sensor occurs

~ Is insertion of
main PCB connecter(CN31)
normal?
Repair badness on
connector contact or
omission
$ outer temperature
x Reference 4. ensor forging normal?

Replace temperature
sensor
Is voltage input of
ICOM PIN #60 normal?

Check main-PCB cold


lead or short
No defect on PCB and temperature
sensor. Recheck connector contact
badness

@ When abnormality of temperature sensor of Refrigerator occurs

$ outer temperature
« Reference 4 - sensor forging normal?
Replace temperature
sensor.
\s insertion of
MAIN-PCB connector{CN30}
normal?
Badness on connector
contact. Re-insert.
Isconnection cord
between main-PCB connector
(CN30} sensors?
Disconnection of wire
between connector and
sensor.
is input voltage of
MICOM PIN #58 normal?

Check cold lead, short,


lead touch.
No defect on PCB and temperature
sensor. Recheck connector contact
badness
@ When abnormality on defrost sensor of Refrigerator occurs.

{s_insertion of
MAIN-PCB connector(CN30)
normal?

Repair contact badness on


connector(CN30) and un-
inserted part
x Reference 4-- ls defrost sensor
forging normal?

Replace temperature sensor

Repair the un-inserted


Connecter or contact badness.
N
MICOM PIN#59 normal?

Check cold lead, short and


lead touch
No defect on PCB and temperature
sensor. Recheck connector contact
badness

@ When abnormality on temperature sensor of freezer occurs

Is insertion of main-PCB
connector{CN30) normal?

Repair contact badness on


connector(CN30) and un-
inserted part.
Is defrost sensor
x Reference 4 -.-
forging normal?

Replace temperature sensor


IS connection
between defrost sensor and
connector normal?

Repair the un-inserted


Connecter or contact badness.
Is voltage input of
MICOM PIN#56 normal?

Check cold lead, short and


lead touch
No defect on PCB and temperature
sensor. Recheck connector contact
badness
© When abnormality on defrost sensor of freezer occurs

Is insertion of
MAIN-PCB connector(CN30)
normal?
Repair contact badness on
connector(CN30) and un-
inserted part.
Is defrost sensor
x Reference4 - ;
forging normal?

Replace temperature sensor


i$ connection
between defrost sensor and
‘onnector normal?

Repair the un-inserted


Connecter or contact badness.
Is voltage inputo:
MICOM PIN#57 normal?

¥ Check cold lead, short and


No defect on PCB and temperature sensor. lead touch
Recheck connector contact badness

9-5) When alarm is continuously ringing )


PRR AE ARENT DNAS OTROS RPT IAM AP ARID RIEL MAE I TMT EGP T LER LE tH OFT 'GATEN Sh IPERS RRA AOI PO REE ARIE IEEE BPI

@ When Ding-Dong sound continuously occurs

|s there any
penetration of moisture to
door siw?

Do input voltages N
of MICOM PIN #45, #46
hange?
(DOOR OPEN/CLOSE! : : :
Yy Repair cord disconnection and
badness DOOR S/W
Is insertion of N
MAIN-PCB connector(CN30)
normal?

Reference

- Alarm for freezer/Refrigerator door open continues for 10sec. at the initial door open. After 2 min. of
initial opening, it alarms for 10sec. by the min.
cycle when doer remains open (10 times of Ding-Dong sound).
@ When “Beep-Beep” sound continuously occurs

Isn’ t forced
operation or defrost
elected?
Cancel forced operation or
defrost.
Does buzzer
sound occurs ifpower
is reset?

MAIN-PCB is normal
Check dirt insertion and short on test
jumper part inside of the MAIN-PCB

+ Sound of “Beep-Beep” does not occur except abnormalities due to forced operation, defrost or
self-diagnosis abnormality.
* In case of self-diagnosis abnormality, it is easy to check because it is indicated on panel-display.
If “Beep-Beep” sound continues to ring though panel display is normal, it is considered that
forced operation or defrost is selected.

@ Incase PANEL-DISPLAY is not lit

fs connector
insertion of HINGE-UP cover
normal?
Re-insert connector, repair
badness on contact
Is insertion of MAIN-PCB
connector(CN50) normal?

Re-insert connector inside

i.
of the MAIN-PCB.

Re-insert connector, repai


Y badness on contact.
Replace PANEL-DISPLAY |
@ When key selection of PANEL-DISPLAY is not available

ls connector insertion
of HINGE-UP oe of freeze

« Repair on the basis of Re-insert connector.


connection diagram of electric Repair contact badness
wire assembly cabinet-door of
Reference 1.

Re-insert CN50 connector,


correct and repair.

Re-insert connector,
correct and repair.

Reassemble PCB base,


resolve pressed part.

Isitbadness of *
70501 or short-related defect on the
MAIN-PCB
Replace and repair
20501.
ls GRID signal
inputted tomc M PORT

x Check if corresponding GRID Replace and repair the


signal is inputted when PANEL-PCB MAIN-PCB ASS’ Y
SMW button is pressed. Repair corresponding button of
PANEL-PCB, or replace PANEL ASS’
Y PCB
9-6) When FAN does not work }

@ When FAN of freezer(F-FAN) does not work (when COMP operates normally by temperature).

Is COMP in “off” state?

Allow forced operation.

« Check only at the condition where


Refrigerator door is closed.

Check sensing circuit on PCB related


with F-DOOR S/W. Replace and repair. :

x Judge on the basis of


abnormality of DOOR S/W in F-FAN is normal.
“check item” of this manual Ref 5. -
Y

Badness of fan itself. Replace


and repair

x Refer to checkup method of relay


badness on Ref 2. Re-insert connector and
A repair.

“Check cooling fan only at the condition of selecting forced operation necessarily.”
1. When COMP is turned off, cooling fan of freezer(F-FAN), cooling fan of Refrigerator(R-FAN),
COMP, and cooling fan of COMP mostly retains “off” state. However, in case of R-FAN, it can
operate for some period of time by natural defrost function if COMP is turned off.(it operates
depending on temperature condition of Refrigerator)
2. Evenat forced operation condition, R-FAN is not always turned on (including normal operation)
and retains “off” state if temperature of Refrigerator room is reached the set temperature.
3. When the door of freezer and Refrigerator is closed after opening, each fan has its delay time. That
is, fan stops immediately when door is opened during its operation, and operates again after
delay of about 10sec. or 1min. (when outer temperature is over 35‘C) when the door is closed,
@ When Refrigerator fan (R-FAN) does not work (when temperature sensing function in
Refrigerator room is normal).

Is COMP in “off” state?

Let forced operation. |

Open refrigerator door to raise


temperature inside of refrigerator

Is R-FAN tumed off?

Check sensing circuitonPCB |:


related with R-DOOR S/W. Replace} :
and repair.

v Y
x Judge on the basis of
R-FAN is normal
abnormality of DOOR S/W in
“check item”of this manual Ref 5.

N Badness on fan itself. Replace


Y and repair.
Is contact
of CN72 on the PCB
normal?

Y: Re-insert connector and repair.


Replace and repair the MAIN-PCB
ASS’ Y
There exists the risk of electric shock when replacing the lamp inside of
Refrigerator. Replace and repair at only “power off’ state.

9-7) When lamp inside of Refrigerator is not lit.

Ts connector contac
inside of Refrigerator

Re-insert connector and


repair.

Replace LAMP in the


Refrigerator.

pay
Check and repair R-DOOR S/W.

y to socket of R-LAMP and repair.


x Check on the basis of
abnormality checking method for
DOOR S/W of Ref 5.
There exists the risk of electric shock when replacing the lamp inside of freezer room. Replace and repai
at only “power off” state.

9-8) When lamp inside of freezer is not lit. )

Is connector
contact inside of freezer
Y normal?

x Inside of cover of FREEZER-LAMP Re-insert connector and


repair.

Replace LAMP in the


freezer.

Yy
Check and repair F-DOOR SW. Y
Check if voltage of 230V is applied
y to socket of F-LAMP and repair.
«Check on the basis of abnormality
checking method for DOOR S/W of Ref 5.
9-9) Abnormality diagnosis method for ICE-MAKER )

Power Resource
Is DC electricity Badness of power! Replace the
Terminal Check
3V, 12V) normally outputted? resource terminal MAIN-PCB

Is ICE-MAKER
dish horizontal?
Disconnect
connector like “<~
Ref. 8
Badness on
motor

Is TEST SMW(both ends Badness on


of 2: and ©) open? TEST S/W
Kit Check (CN90
Terminal WIRE
HARNESS)

S horizontal S(W(both Badness on


ends of © and 8) open? MICRO S/W

is ice-check
S/W(both ends ~ Badness on
of 3 and @) open? MICRO SW

Sensor Check S iee-gject sensor


<{both endsofF andZ)within rangewritten o
Badness on ice-
(Ref. 4) eject sensor
tableofRet. 8?

Pressog lestsw ct orethen


Motion Check URS. does perfor: e-eect
andharzon's Badness on kit
suai igen sourd of DoeDong” ASS'Y

Replace kit
ASS’Y
9-10) When cube and crushed ice are not normally operated. 7
aed
Sart cc SPP AS PSPSPS SADA Dt PTNACA RY SESE ATRIA SHEAT, BAS NE NEAT IEE AEA BERNADETTE, PI ER IN ME LAMAN oD RPC EE

@ When cube ice does not come out when cold cube ice is selected.

When cube ice is


selected, does cube ice
ome out?
Isn't freezer door open? Close
the door if it is open.

hen ice lever is~


operating, does cube ice

Is micro port #20 on


MAIN-PCB “HIGH"?

Replace and repair MAIN-PCB


ASS'Y

Is relay K76 turned on?

Replace and repair relay RY76.


Does drill motor
solenoid inside of freezer operate
normally?
Check tead wire and repair
defected part

ls tap water normally supplied?

Re-check the water supply


point.

Reference

*When motion system is normal, however, if there is no ice in the ice container, ice does not come
out. Please ensure whether there is ice in the ice container.
9-11) When solenoid which is cover ice-route delay device does not work )

Pre-checkup

1. Check whether solenoid automatically operates for 0.3sec. regardless of open/close of cover
ice-route 8 sec. after initial power on.
2. Check whether Hinge-up connector contact is normal.

iththe intial power on,


No defect on S/V control PCB ASS'Y does MICOM #18 onPCB indicate HIGH”
and wire system state for0.3se0.?

Check and repair MICOM control port is normal


hen ice lever.is
devices such as pressed, doesitmaintain
stopper lever &
support, etc
thepoint
inital power on, does 1003 utindicate “LOWE
Check ICE SW. salefor0.350?
Check and repair
Badness of IC03.
wire connection Exchange
system Exchange defected parts
after checking SSR71 or
S cover closed replace PCB ASS’Y. =
after about Ssec. by SIV Utilize checkup
operation? rnethod for SSR
defection of Ref. 2

No defect on cover ice-route control


system

+ S/V is abbreviation of Solenoid Valve |


10. Operation Principle & Repair Method of ICE-MAKER

10-1) Operation Principle of ICE-MAKER

Performance of motion to retain horizontal level


of ice-making dish for initial power apply or for
restoration from stoppage of electric current.

ice-eject motor
stop
Reverse-
rotation of ice-
eject motor
Wait for 1 cycle Performance of ice-separation regardless of
(under -7°C)
water supply to ice-making dish by waiting for 1
cycle.

Ice-eject step
After ice-making is finished, motion of ice-
separation from ice on dish into storage
container. Ice-separation is performed by
checking the horizontal s/w, and the signal
change of ice-inspection s/w and the changed
time. They should be checked together in parallel.
Water supply
step

After ice-making is finished, motion to supply ice-


. making water to ice-tray using water valve.

This step means the period from when water


supply is finished to when it is judged that water
tumed into ice completely. This is judged by
parallel checkup of temperature and time.

Y
Test step Function for cases which are needed for forced
operation for the purpose of operation test, A/S,
and cleaning.lce-separation motion and water
supply motion are conducted continually and this
step should have priority than any other
operations.

|
10-2) Ice-maker Test Function )
5. Test Function
@ It is function for the case which needs forced motion for the purpose of cleaning and
so on at the time of operation test and A/S. This function is performed when the test
s/w which is equipped with the body of automatic ice-maker itself, is pressed for
more than 1.5 sec..
1) Test button does not go into test function during ice-eject, levelling for horizontal
position and water supply. It operates in the horizontal state. It does not operate at
the state where ice is fully filled. Only after ice full mode is cancelled and ice-check
s/w is off, test function operates.
2) When test button is pressed in the horizontal state for more than 1.5sec., ice-eject
motion starts immediately regardless of conditions of ice-making
container. Therefore, if test function operates in the state where water does not
freeze yet, water may be poured. So, care should be taken. After ice-eject motion,
1cycle of water supply is carried out in horizontal levelling movement. Therefore, the
problems of ice-eject movement, horizontal levelling movement, and water supply
can be checked by the test button. At this time, when the test function operates
normally, buzzer sound “Ding-Dong” occurs and starts water supply function. Hence,
if buzzer sound “Ding-Dong” doesn’t occur, it may be considered that there is some
abnormality so that check and repair are indispensable.
3)When water supply is finished, it operates in normal cycle of ice-making—
ice-eject— horizontal restoration— water supply in order.

<Case Where Test Function does not Work>

Remark

Turn ice-check lever On — Off.

6. Function according to F-Room Door Open


@ This is function to minimize noise occurrence by stopping operation basically
when door F-room opens.
1) If F-room door opens while ice-eject or horizontal levelling is working, the function
stops immediately at this point of time. When the door is closed, function operates
normally.
2) In case water is being supplied, normal function is performed regardless of door
open of F-room.
3) Accordingly, when F-room door is opened to check, if tray leans or its angle deviates
from horizontal position, it is considered that it stops during ice-eject or horizontal
levelling movement. It doesn’t matter to judge it as a defect if it is not in horizontal
position after more than 30sec. passes when F-room door is closed to keep
horizontal state after water supply. In case it stops by F-room door open while it is
operating, Test function doesn’t work because it is actually working. So, after
finishing water supply, test function operates.
10-3) ICE-MAKER Circuit Part (Limited to equipped model)

TMP87CK40
eer eee
we ew eK

ICE-MAKER KIT

EJECT-MOTOR

nN
THERMISTOR(EJECTING)

HORVINV Sw

LEVER SAW

on

Above ice-maker circuit is one about a kit which is equipped at the freezer. Water
supply to ice-making container is performed by operating AC solenoid which is
located in the machine room through relay so that water is supplied by open/close
time of valve. This circuit is H/W for embodiment of functions such as eject of ice-
making container, horizontal levelling, ice-making temperature sensing and full-ice
sensing. Temperature sensing part is identical to that of the main H/W, and
horizontal(Hor/Inv) S/W, Ice-check(Lever) S/W and sensing circuit are identical to
those of the main HW. So, explanation about this is omitted here, and only ice-eject
motor driving circuit part is explained.
When rotating motor in the counter-clockwise direction(CCW), if signal of
Micom Port No #10 is outputted to High. When pressure of IC05 is applied,
the voltage is applied of +12V by output of ICO5 17, and the current is supplied to
1C04 of @ through motor. At this time, © terminal of 1C04 is connected with CCW
Port together so that output port of the corresponding IC04 @ is turned on.
Therefore, current flows to the ground and motor rotates inversely.
When it moves to clockwise direction(CW), CW Port #9 is outputted by “HIGH”. The
functions of ice-eject and horizontal levelling are performed by the operation of IC
Port through right direction rotation movement.
For the points related with operation of above circuit, refer to the explanation of ice-
maker function of our SVC Manual.
10-4) Designation of major components of Ice-Maker

\CE-MAKER, KIT

(EJECT-MOTOR) SUPT-RUBBER

TRAY-ICE
({EJECT-SENSOR) ( )

TEST-SWITCH
FIXER-SENSOR

KNO8-TOUCH COVER-SENSOR
GUIDE-ICE

10-5) Operation of Ice-Maker

1. Connect the water-supply line to the supplying valve of the refrigerator to


supply water.(See the water tube connection procedure)

2. Push bucket to the end so that guide-ice of ice-maker is not in contact with the
end of bucket.(If the end of bucket is in contact with the guide-ice of the ice-maker,
the ice-maker will determine that there is enough ice and does not make ice
thereafter.)

3. With a newly installed refrigerator, allow about 6 hours for the refrigerator to
make ice normally and discard the made ice several times to remove impurities.

4. To get enough ice stored in the storage bin, use the ice dispenser normally after
operating the ice-maker for about 24 hours.

SUPT-ICE, MAKER,

BUCKET

ICE-MAKER KIT

Push the bucket to the end so that the


GUIDE-ICE of the ICE-MAKER is not in
contact with the end of bucket.
10-6) Disassembly of Ice Maker k

1. Pull out the bucket from the freezer.

2. Disassemble the SUPT-ICE MAKER, which fixes the ice-maker, and the wire housing
in the rear of the maker.

3. Disassemble by lifting the SUPT-ICE and FIXER-CASE in the front of the maker up
(® direction) and pulling the ICE-MAKER KIT out to the front (@ direction).(Do not
disassemble each component of the ICE-MAKER KIT. Otherwise, the setting value
may be changed.)

SUPT-ICE, MAKER

Wire housing

10-7) Assemblyof Ice-Maker

1. Fit the rear rising of the ICE-MAKER KIT to the front slot of the TRAY ICE.

2. Lift FIXER-CASE at the front of the SUPT-ICE MAKER up. (@ direction)

3. Place the top rising of the ICE-MAKER KIT to the slot of SUPT-ICE MAKER for
insertion.

4. Push the front of the ICE-MAKER KIT while maintaining the position.
(Be careful. If you overpush the ICE-MAKER KIT, the fixed rising of the SUPT-
ICE MAKER may be damaged.)

5. When the front of the ICE-MAKER KIT is sagging, it means the assembly is not right.
At that case, perform the assembly again.

FRONT SLOT

FIXED RISING
ICE MAKER KIT TOP RISING
11. Reference ,

Reference No. 1) Electric Wire Assembly Cabinet-door Connection Drawing )

Connected at HINGE-UP part of freezer

MAIN PCB PANEL PCB


ASSY ASSY

Reference No. 2) Test Method of Relay Defect

5 Gorfact Pol 2 Contact Point ie Point


First, separate housing which isconnected to load
No . : Oo pe Oo connection part(Main PCB CN70~CN71). Check the
Cc +s .
aes —<— following items (Judge by voltage and resistance value).
— CN71
S| 1, Judge whether relay moves or not by measuring
elie) caus JeoO =——
= .
voltage of both coil+ terminals. .
; "_ Checlayp alter separation 2. Judge whether SSR moves or not by measuring
Se Trigger Terminal voltage of two trigger terminals.
eet Tenis ; 3. Load contact point of two terminals are measured by
Note} NC—-Normal Close(C Terminal and Common ON Terminal) resistance value. Whether there is fault or not is
NO—Normal Open(C Terminal and Common OPEN Terminal) © judged by comparing with voltage conditions of coil
C —Common Terminal and trigger.

ContactPoint]ci and Trigger Two Terminal Voltage| Two Terminal Contact Point
DC about 12V Between C and NO} 0 2 (SHOST)—Normal
3 Contact (Movement Condition) Between C and NCI oo 9 (QPEN)—3Normal
Point i
Relay DC About OV Between C and NO} © 2 (OPEN) Normal |

koiop-onaiaan) Between C and NC} 0 9 (SHORT)—»Normal


P Contact Pint DC About 12V(Load Movement condition) Cladus
et Tinmis |QQ (SHORT)—Normal
Relay DC About 12V(Load Stop Condition) (naa ei » 9 (OPEN]Normal
DC About 12V(Load Movement condition) | CavaPorisBeenFinminds|AboutKY~5 kt(SHORT)—Nommal “|
SSR :
DC About 12V(Load Stop Condition) CoadPa BeenIe mins|co Q {OPEN} Normal
Note) SSR: Solid State Relay (No Contact Point Electric Type Relay)
Reference No. 3) Load Defect Checkup }

After separating power cord from power


source plug socket, separate connectors
CN10, 70, and 71 of the main PCB, and
check the following items.

1. Measure load terminal and resistance value


between terminals like the following to check
whether there may exist defects of load and
electric wire connection.

Load Terminal Fault Item Remark


F-Defrost |Between CN70@) | 09 | Badness oflemperatur, fuse, heater, electric
wireshort-circuit
Heater and CN10@ | 09 | Badness of temperature, fuse, heater,
andelectric wire disconnection
R-Defrost | Between CN716 | 09 | Badness of motorcollandwireshort-circuit
Heater andCN10@ | <9 | Badness of motorcolandwireshort-circuit
Ice Solenuid | Between CN71@ | 02 | Badness of coilandwireshort-circuit
(Machine Room) | andCN10@ | co9| Bachness ofcoilandwireshort-circuit VM Application Mode!
Cube Solenoid |BetweenCN71@ | 09 | Badness ofcoll and wire short-circuit
andCN10@ | > | Badness of collandwireshort-circuit \/M Application Model
id |Between CN71 | 0g | Badness of coilandwire short-circuit sant :

| Augen |Baer §
009 [| ~~]
Baasalee taind
|08|Badiness ofcoil and wireshort-circuit
"Aon os
MOTOR | andCNi0 | 9 | Badness
ofcoilandwie short-circuit UM Application Model

"Seen [oaeati [oschet


——————ug
eand
HEATER | siybuelalRowsit }co9| Badness of heaterwireshor-circuit
Note) COMP parts can be changed by Capacitor, PTC, and Over Load Protector. Therefore, they
coving cesar)

are checked by existence of movement.

Reference No. 4) Fault Check Method of Various Sensors 2


SS a SAE cs SSS TRS“ SAY Pa lS ASR AUER SPERSNTEL SO”

After separating connector from the MAIN-PCB,


CN30 measure resistance of sensor forging, and judge
Freeze Sensor fault existence.
F-Defrost Heater
1. Freezer Sensor CN 30, measure resistance value between
MAIN PCB and
Refrigerate Sensor Heer 2. Retrigerator Sensor CN30, measure resistance value between
R-Defrost Heater and
SIS)
EXSICISISCISY
3. F-Defrost Sensor CN30, measure resistance value between
OH CN31 and
4. R-Defrost Sensor CN30, measure resistance value between
and
HOS
5. Outside Air Sensor CN31, measure resistance value between
and
Measurement after Separation | 6. Compare above measurement value with temperature of
location of each sensor. Also compare with sensor resistance
and voltage conversion table about temperature of Ref. 8 of
this manual. And judge whether there is any defect.
At this time, when measuring « 2 or 02, check wire assembly
condition.
Reference No. 5) Check Door S/W Fault & Ice Lever S/W Check Method )

| Check in state that power is applied.


| Door S/W is 2 contact-point circuit;
| one contact-point senses door
| open/close with DC 5V on PCB, and

FROM POORceazvensw| ao
| the other contact-point lets refrigerator
inside lamp fluorescent On/Off.

(R-Room Lamp Part)


1. When refrigerator door is opened, check whether lamp is lit up or not. If it is normal,
check whether lamp lights out or not when pressing DOOR S/W in the state that R-
DOOR is open. If any faults are found, check DOOR S/W of R-ROOM door.

(MAIN-PCB Sensing Part for R-ROOM Door Open )


1.Check voltage by applying “+” terminal to CN30 and “-” terminal to .
2. When R-ROOM door is opened, if about DC 5V is measured, it is normal.
3. When R-ROOM door is closed, if about DC OV is measured, it is normal. If any faults
are found, check DOOR S/W and wire connection system.

(F-Room Lamp Part)


1. When freezer door is opened, check whether lamp is lit up or not. If it is normal, check
whether lamp lights out or not when pressing door S/W in the state that F-DOCR is
open. If any faults are found, check door S/W of F-ROOM door.

(MAIN-PCB Sensing Part for F-ROOM Door Open )


1.Check voltage by applying “+” terminal to CN30 and “-” terminal to .
2. When F-ROOM door is opened, if about DC 5V is measured, it is normal.
3. When F-ROOM door is closed, if about DC OV is measured, it is normal. If any faults
are found, check DOOR S/W and wire connection system.

(ice Eject Lever)


1. In case ice is not ejected though ice eject lever which is installed at the front part of
freezer, check like the following.
2. First, check fault existence of F-ROOM DOOR SM. If no defect is found, separate
CN31 connector on the MAIN-PCB. Apply “+” terminal to and “-” terminal to, and check
resistance. Check it becomes 0 2 when ICE LEVER S/W was pressed. When it is
always oo regardless of ON/Off of S/W, check wire system and connection system.
Reference No. 6) Resistance of Sensor about Temp. & Voltage Conversion Table )

Voltage inputted to Micom Port differs according to H/W structure. This


specification is standardized one
by voltage which is applied at the time when
100-F grade of partial pressure resistance is used. ~ = oe
Corresponding Micom Port Voltage Specifications when Sensor is Open : DC about
5V(Vcc Level)Corresponding MicomPort Voltage Specifications when Sensor Short :
DC about 0V(Ground Level) anes uo a

2
Fa
2 108 |

4.235

a6
“ia
;
. 15.328 3.025

ssn
27 09

26 42.733 4.051

20 40.626 4.012

297
Fan)
aid
i)
alr

“24 ;=

“23 3.93 So

22 3.888 01

“21 286 02

“20 28 03
-19 38 04

“18 28.838 3.712 05

2.518
:mn=|~N
a 2.468

“15 29.040 3.573 9.375 2419 31 4072

“14 23.906 3.525 32 3.938

“13 22.832 3.477 8.673 2.322 300


Reference No. 7) Forced Operation and Defrost Input Method h
(Forced Operation)
itis a function to operate COMP and F-fan immediately regardless of freezer temperature.
1. When pressing Quick Freeze S/W and Cold room Temperature Control S/W on the Panel together more than
8sec., all displays become Off. And, four temperature corresponding S/W(Quick Freeze, Vacation, Freezer
Temperature Control, Refrigerator Temperature Control) operate by test button.
2. In the above state, when pressing any one among four control S/W once, forced operation starts.
(Forced Defrost)
It is a function to make R defrost or R and F defrost at a time regardless of defrost time,
1. In state of forced driving, when pressing the S/W once, R room alone is defrosted. And, if pressing it once
more, simultaneous defrost of R and F is performed.: Buzzer sound occurs at forced defrost, too.
2. After making Power Off and let it be On again, cancellation is made.

Reference No. 8) Circuit Par Service Material List


<Eject Motor Check>

Check Method for Motor when EJECT


MOTOR does not operate.
EJECT MOTOR .
1. Disconnect CN90 from MAIN PCB.
MAIN PCB 2. Check the resistance value between (@) and
ASSY
@ of CN9O, connector, of Load Terminals.
3. If the resistance value is between 18 and
22 Q, itis normal.
4. If the value is 0 Q, itis SHORT fault. Check
the wire connection state and Motor.
5. If the value is o Q, it is OPEN type and
check the wire connection line.

<TEST Operation method>

This is for check whether the Motor operates


normally and whether water is normally
supplied.
PCB PANEL 1. When S/W in the KIT inside the Freezer is
pushed, TEST operation will starts. More
8 Pieces of Wire detailed instruction of Test operation, refer to
TEST S/W
the section of the ICE-MAKER TEST functions.

Reference No. 9) Circuit Part Service Material List

CODE-NO Product Name Quantity | Remark


| 1 | DA4i-o0024a 1 Basic Type
DA41-00027A MAIN PCB ASS’ Y 1 ioe & Water Disp Tyne
Basic Type
DA41-00020B fT Fe aWaterDispTipe
[6 DAs2101080" | FROutsideROOMAirSENSOR
Senso
[-7_|paae-1o1ogn | F-EVASENSOR | _5O2AT(@40mm) [1
S02AT(370mm)
| 9 | DA27-00002A NOISE FILTER CAN TYPE
|10 | 3301-00016 FERRITE CORE Common Use
12. Disassenbly Method of Freezer & Refrigerator

12-1)RIN Disassembly
Nee IN 8
Method of Freezer
ATOR: nn RAREGI
& Refrigerator
AE AE ARATE
NS SORIA
Accessories
ERE EIT SCR OE ITE a AE ERATE ST
pA RENNES EAE NENA 1ITE
TPR ENN TESTI peusicsomemmoenner
cit

Sensor Cover - Dispenser (SR-$2028, $2029, $2228, $2229). . -.. ¢Deodorizer Cover...
ieee cagcas y oie eaibdbpeade E04
Dry Room Cover

@ After rotating cover “B’ in the left direction and e Dispenser(SR-S2028, $2029, $2228, e Press the jaw which is placed at the outside of @ After deviating from the jaw of cover by pressing
pulling it out, release screw with a (+)screwdriver. $2229)lift the front cover and take out. deodorizer cover and pull out. it to the left, lift it upward and pull out.

tioD =

|Interior Lamp of Freezer (Basic) Shelf


Deviate the jaw of interior lamp cover by pressing it in @ Draw the shelf. Lift the shelf at the point where it is
the arrow direction of with (-) screwdriver or similar caught, and pull it out.
tools.
Turn the interior lamp in the left direction and pull it
out.

RE Pi fe rae es CONE

@ Grab multi-purpose compartment with two hands


e Unscrew the lamp with (+) driver-and deviate and lift up. Take it out.
the projection jaw.
@ Replace the lamp in inner refrigerator room by
disassembling Lamp-Cover.

o Cd
ae Sal e Cd

5 Nell o”
cd at7

Ic@Storage Container &Ice Container =" = BES? Leg front


COVER »? Vegetable and Fruit Box .
(SR-S2026,S2027,$2226,S2227) @ Pull vegetable and fruit box forward with
e After opening doors of freezer and refrigerator,
@ After pulling the ice storage container forward, disassemble three screws on leg cover, and pull it grabbing handle of it. Lift it up a little at the
take it out. Then, pull ice container forward and out. point of jaw, and take it out.(@)
take it out. ~ = @ When inserting @ Pull forward and
ana leg cover, set itto take out the cover
three grooves and of vegetable and
assemble screws. fruit box.(@)
J2-2) Disassembly of Cooler Part of Freezer Room a eee TY: 12-3) Disassembly of Cooler Part of Refrigerator Room _
ME PUA 8 CANS! ATE GARD SEMEL CE OROEERE I

a a ae ——--—-— os 4

1. Using (-)screwdriver or similar tools, | 1. Using (-)screwdriver or similar tools,


disassemble the cover of inside lamp. disassemble the cover of inside lamp.

ae
2. Separate cover-sensor B by turning to
2. Separate cover-sensor B by turning to the left, and disassemble screw of
the left, and disassemble screw of cover-sensor A using (+) screwdriver. | h
cover-sensor A using (+) screwdriver.

“)P
3. After disassembling the housing of C
temperature sensor and inside lamp, °
3. After disassembling the housing of remove the fixed screws (5 spots).
temperature sensor and inside lamp, And, pull forward the lower part of
remove the fixed screws (5 spots). cover-multi with hands.
And, pull forward the lower part of
cover-multi with hands.

4. Deviate the jaw part of deodorizer


cover (left - right) and disassemble it.

4. Grip the upper part of the front cover of


cooler. Pull it carefully in the arrow
direction. Deviate the jaw part of cover
and pull out. 5. Remove the fixed screws (4 spots) of
the front cover of cooler using (+)
screwdriver. Deviate the jaw part of
cover by pulling it carefully in the arrow
direction.

5. Disassemble motor and heater housing


from the wire terminal which is
assembled at the inside of upper side.
6. Disassembie motor and heater
housing from the wire terminal which
is assembled at the inside of upper
side.
12-4) Temperature Control Part

_ §R-S2026, $2027, $2226, $2227


Basic & with Home-Bar type

Housing

Cover control Rear

PCB Transparent Window


Cover control Front

$R-S2028, $2029, $2228, $2229


Dispenser & with Home-Bar type

Housing

Cover control Rear

PCB
Transparent Window

Cover contro! Front


@ Disassemble the projection jaw using a ©) @ Disassemble wire housing connected to
screwdriver to the groove of lower part of PCB. Disassemble PCB plate at the
Control Front Cover. projection jaw.
@ Assembly is done by reverse order of
disassembly.
13. Method of HINGE-UP Assembly & Disassembl

1. HINGE-UP ASS’Y Structure

FIXER-HINGE, UP
HINGE-UP ASS'Y

EARTH LINE

erecten tinesstp Slee

weet ne Pte nega Phena Te centea acacia aeetarae a

HINGE-UP ASS'Y

REINF-HINGE, UP

est
Ne
SERN
PN
PO
ETE
EEN
emer
TAT
een
TERETE
OU
EY
é
SO TE nme eee ea eee aR mR Se : 1 RENT ATA MN arrE REE NEETRIM

2. HINGE-UP ASS’Y Method


1)After inserting HINGE-UP ASS’Y to REINF-HINGE UP in the direction, combine it by rotating it in
the direction.
2)After inserting FIXER-HINGE UP to REINF-HINGE UP in the direction, assemble it by rotating it
in the direction.
3. HINGE-UP ASS'Y Disassembly Method
+ Disassemble it in reverse order of assembly method.
2 co) 0%
= a ae ® 7 Dm® tneo oO ten uup7Qa
somal ent co)Cr) > & = aoadaL
Lael

14-1) Freezer Room Exploded View (SR $2026, $2027, $2226, $2227/S20NTC,S20BTC,S22NTC, S22BTC)
= Accessory Parts of Freezer Room (SR-S2026, $2027, $2226, $2227/S20NTC, S20BTC,S22NTC, $22BTC)
' Specification Remark

3
& on© = 8

3 125V/250V, 5A, PAB, WHT

5 > (DEFROST SENSOR)

3
6-2

aan comma Rw
6-3
ER

[peso eoaanern 8 ae
COVER-MULTI FRE, ASSY | PP 1

iI
a SENSOR-ASSY GOAT, TEMP CAP
TYPE

EEE
1

1
9-7 SEAL-COVER MULT FRE | ‘L", HOMO-PE, 1035 1
DA72-00159C |SEAL-COVER MULT FRE | °R°, HOMO-PE, 1035

10 CAP-SCREW SILICON
" COVER-EVAP FRE, ASSY | PP, 220V
11

11-2} DA31-00016A FAN-CIRCUIT ABS, 995

11-3} DA61-20128A |SPRING-FAN STS27, 10.1.0, P17.8

11-4) DA63-00153B }COVER-EVAP, FRE PP =


ee

11-5] DA63-00184A |COVER-MOTOR

11-6] DA63-00423A | GROMMET-MOTOR NBR, BLK


Ee

11-7} DA67-00158A |CASE-MOTOR PP, BLOC


6002-000215 |SCREW-TAPPING TH+, M4x 16, ZPC(YEL), MSWR10
EF
Indicated part is for electrical safety components
Product Name Quantity
1

|
= 1

mle

ole

fener eae
ee eee,
CASE-BASKET, UP PP

° 5 1

16-1 |DA64-000S0A eat

Parfons |siarmeions |
DA66-00047A |TRAY-ICE. ASSY

18-1 |0A61-20136A |SPRING-ICE, MAKER

DA66-00032A |TRAY-ICE

_ 8-4 |DA71-00059A | FIXER-TRAY, ICE

DA67-00186A |CASE-ICE CUBE, ASSY —_—ae

DA63-00179A |COVER-TRAY HIPS

19-2 |DA67-00155A |CASE-TRAY, ICE GPPS


14-2) Refrigerator Room Exploded View(SR -$20 ~ $22.)

SR-S2028. S2029,S200TC.S20FTC
$2228, $2229.S22DTC.S22FTC
Reet aa ghee aay ee ee ee ea
« Accessory Parts of Refrigerator Room(SR-S20..~S22..)

DASG-00066E |EVAP-REF, ASSY ee


4-1 |DA32-10109N |SENSOR-ASSY Rae
4-2 |DA47-10118A |THERMO-FUSE, ASSY
4-3 |DA71-00082A |FIXER-SENSOR
5 |4713-01123 |LAMP-INCANDESCENT
DA63-00218A COVER-MULTI REF, ASSY ba ee
6-1 |DA32-10105H SENSOR-ASSY aaa eeen
6-2 |DA47-40112Y |LAMP-HOLDER
6-3 |DA63-00188A |COVER-MULTI, REF po
[omens
a orca
secien mnar
marr [aw
[ewe [2
[1 |
|
[eon eacortmr Jeremie [1 |
;
s{e|e|
401 UDGMOOZHAASS, 2660-pm
|

STSI7. 1D. PI78

DA67-00158A | CASE-MOTOR PP, BLOC 1

6002-000215 | SCREW-TAPPING TH, M4x 16. ZPCCYEL), MSWR1

40-9} 6002-000471 | SCREW-TAPPING THA, M4x12, STS304 1


oe indicated part is for electrical safety components
NO | CODE-NO Product Name Remark

0-10 DA72-00142A |INS-COVER EVAP REF, A


0-1 DA72-00143A |INS-COVER EVAP REF, B 1
—s
ow
|>-1 DA72-00229A
|—
nm |SEAL-AIR REF, UP 1
4 0A63-00365B |COVER-PURIFIER L, ASSY 1
— ibe 0A02-90106J |CATALYST-LTC LTC, $$-400-15-2, T.15 1
=.1-2| DA63-00163A |COVER-PURIFIER, L 1
12 |DA63-00366B |COVER-PURIFIER R, ASSY 1
12-1] DA02-90108) |CATALYST-LTC 1
12-2} DA63-00164A |COVER-PURIFIER, R i
13 |0A67-40250F |TRAY-UTILITY i
4 |DA67-00148A
— |SHELF-REF, LOW 1
5 |DAG7-00149A |SHELF-REF, UP [pe+cass
| ||

6 |DA66-00038A |TRAY-CHILLLED, ROOM 1


17 |0961-601838 |RAIL-LOW L, ASSY
17-1| DAG1-60179A |RAIL-LOW, L
17-2| DA63-40256B |GROMMET-RAIL
:18-1 DA61-60180A |RAIL-LOW, R B
Oo> &
oD = © oo D 2 Ce a OQ= pe)
aa >

18-2 DA63-40256B |GROMMET-RAIL


19 |0A63-10942A |COVER-VEG, LOW 1
{>

20 |DA67-00184A |CASE-VEG UP. ASSY 1


20-1 |DA63-00175A |COVER-VEG FRONT, A 1
20-2] DA63-00177A |COVER-VEG FRONT, B i
20-3} DA64-00085A |KNOB-MOIS, CONTROL __ HIPS |
0-4] 0967-00152A |CASE-VEG, UP
De]
1
21 |DA67-00185A |CASE-VEG LOW, ASSY 1
No1-1 |DA63-00175A |COVER-VEG FRONT, A HIPS
t
N = ho DA63-00177A |COVER-VEG FRONT, B GPPS
21-3} OA64-00085A |KNOB-MOIS, CONTROL HIPS
21-4 | DA67-00153A |CASE-VEG, LOW —
=

DA67-4-250C |TRAY-UTILITY GPPS NTR


DA67-00145A |SHELF-WINE HIPS 1
DA71-20252A | FIXER-GROMMET, DOOR ABS, W9175 2
DA74-00056C |TANK-WATER, ASS’ Y HP-PE 1
14-3) Unit Exploded View(SR-S20. ~$22..)

vy c
On ao On Sf
nunOn
NN oO ww
oo
NN NNNN EEaa
On NNaaOO Ee
roconevo[Petre
| Soin [oma]
a Part List of Unit Exploded View (SR-S20..~S22..)

>

a
DA63-00201B lcoveRHNce UL SC-97527R, S/AWHTE i
iW

toe) i

: 7
1

- ,
— 7
B
Z&|S8

Fe[ovat nee
;}0Iolo
O;ODU
©

7 DAG0-10123E |SCREW-TAP, TITE

Poca joommans
=
x
:
sae [orton ,
2 ova laweraceioner
sama |e |
==

|
S|

124} 6021-00162 |NUT-HEXAGON 2 Ma ZPCCYED, SMC

2}
h> DABO/O146A |SOREW-MACHINE HWH, MOx16, ZPC2, SWRCHIOA

123) DA/1-00131A |BRACKET-HINGE. LOW Za


1

13

=oe=nm
2s

ZsoPnm

—=S

=44 | DA61-00085A

: Indicated part is for electrical safety components


P| orm lonern isms id
Fe)oxsane [omc ideas
[s[oemer fame
Sone
femas
Cr
Es mR
[
a A aan ICE
000213

DAB3-10362A |COVERRELAY BLK. HOOK TYPE

000156 |CABLE-CLAMP DAMC-103, SPC’, PE FOAM

yA S PROTECTOR-O/L ATM26ERFBYY-£3

2 DA36-100138
ose

WARAE
NL i
es
ABE
aeae fs a
*DKIB2QH2U

oe
caus [sare
jw)ABO-IOIOZA
a
funuwaevacn
|«|
|SCREW-EARTH

2 =
oO SOREW-TAP, TITE HH, M6x16,ZPC2-Y

&

in
CASE-PCB. PANEL PP

o_o
DAZ1-00155A | FIXER-MAI. PCB RD-PVC. 120 NIR

= e

DA41-00027A T1.61974123, MAIN PCB ASSY CE & WATER DEP

AE
é
© FILTER-EML AC LINE 250V, 10A, 330000pF, 38 x 50mm

DAS3002124 |COVER-PANEL. PCB

DA87-00176A |CAP-DRAIN. SUB

DA7400044A, |HOSE-DRANN, SUB

4 Rae

sNUEUUUUREEERAAEREN
@
CODE-NO Specification Quantity Remark
Ey DA72-001764 |SEAL-COND FOAMPE, T.?
Bly

DA63-40171B AR BLK

| |_orsesrr0 MRK
ATe-0OO7EC
|
|e

J
UST 9.478
ae | DA73-30102A Cu 0018851102

aoDARIAN
||
-

DA63-00278C SBHGI, T04

8 z HIPP, SC-97527R, S/WHITE

SLO NR
©
sa
53 |oascotasa |PreFRE
HO wareAssy r
|. om 7m
DA/1-20207A |FIXER-VALVE WATER s 3
DAB60-301044 |NUT-WATER LINE

ie
|a: A73-00070C | PIPE-WATER. LINE LOPE, L2300

215
(2 é
38 | DA74-40149C |VALVE-WATER. ASSY

DA72-002288 |SEAL-WATER PPE

60 | DAS3-00432A |COVERPIPE WATER. ASSY


14-4) Freezer Room Exploded View (SR-S2028, $2029, $2228, $2229/S20DTC,S20FTC,S22DTC,S22FTC) }
ASIST.»
SoA I

wee
eww
wr
aw
ew
New
eee

or
ii
a Part List of Freezer Room (SR-S2028, $2029, $2228, $2229/S20DTC,S20FTC,S22DTC,S22FTC)

3
ars
7
: 1
7
ot

on

|
COVER-LAMP, FRE pp

= zw
oO> rona3 ro)= a>fo> COVER-SENSOR, B BS

;
DA63-002318 |COVER-MULTI FRE, ASSY | PP, ET-PJT ae
1
(Freezer Inside Sensor)

0/A63-00363A |COVER-MULTI, FRE eo 1

“L’, HOMO-PE, 70.35

"R’. HOMO-PE, 10.35


P ~s DA72-00226C | SEAL-AIR FRE, UP OJC-3000, 7.7

10 | DAS7-30367B |CAP-SCREW SILICON

COVER-EVAP FRE. ASSY ET-PJT 240

MOTOR-FAN(BLDC) UDOMOOZHAASS, 2650rom

ABS. 995

SPRING-FAN STS27, 1.1.0. P17.8

DA63-00153B |COVER-EVAP, FRE oD


ry
fea
11-5} DA63-00184A |COVER-MOTOR PP, BLDC
11-6; DA63-00423A |GROMMET-MOTOR NBR, BLK
11-71 DA67-00158A |CASE-MOTOR PP, BLDC
6002-000215 |SCREW-TAPPING TH, M4x16,ZPC(YEL), MSWR10
DA72-00227A |SEAL-AIR EVAP, FRE OJC-3000, BLK. 7.5
DA72-00141A |INS-COVER EVAP, FRE
Indicated part is for electrical safety components
el ney oe a ae See
fa[owen lenrecer sr fern ip |
Feifoncarm common memafar Sif |
a [onsennec|comaerser
newtsens |
feslonraneiclowcasetie
[we Sd |
Pos[onranesslexraser
onasvfesa PP
rofonsenrae|covnesser
eweams
: i a
14 |DA67-00179C |SHELF-FRE UP, ASSY eres Tl kl |

fzloworn|sarne
i [weeas [1 |
fis[owronouloerme
ons feou f+)
Fsifonoalmmoar
[eno *t 2 |
sz[ware|sesre
ior [ws
[aor oerne one ewan Td
wilowraom|musar
[eno «2 |
pealveemeomereion
[ws
DA61-70253B |SUPT-ICE,MAKER

DA71-20252A |FIXER-GROMMET,DOOR ABS,W9175

se leer are ome


DA59-00136A |CRUSHER-ICE,ASSY leret Tt |

21-1 |DA65-20121A |CLAMP-HELIX,DISP 2 eee

DA31-20123A DE-DISPENSER STS420-J2,T2.0

Nh DA31-20009A DE-DISPENSER PC.SR-S7240,0D113,T2

nN re DA31-20120C BLADE 518420-J2, 12.0

DA72-60314A SEAL-POM CRUSHER MID, POM

1-6 |DA71-20231A |FIXER-GUARD


Ro -| POM, W9236E

DA31-20122A |BLADE STS420-J2, SR-S7180, 72.0


CODE-NO Product Name Specification Quantity} Remark
21-8 STS420-J2, SR-S7180, 720
21-9 ST$420-J2SR-S7180.12.0
nN1-0]0A72-608134] SEAL-POM | ST9420-J2.5R-S7180.12.0
11} DA31-201208 |BLADE
EE

Nm= STSH002. SX-S7180, 720


0A31-20120A |BLADE
E

STS420-J2, SR-S7180, 72.0 a)


:

No

1-14) DA70-201808 STS304T1.0


1-16]DA63-10016A |COVER-CRUSHER.OISP—_| PC/ABSSC-90417R
EG

Fes

RS-16| 0A71-7003A PC/ABS


EE

tg] oAgo-e0rg6a [PIN


RM
RD] | STS9040D24151.75%-S7180
'- g]OAGO-4O116A |WASHER-PLAIN
EE

Nm => IC200028T05STS
1-20]0AB0-901254 |RING
ia] SK-SHSR-ST1E0
1-24
EE

S|
THMALIOSTS3O4
ie EE

1-23} DA66-30138A |LEVER-DISPENSER


No POM,W9236E.DELRINS
21-24) DA72-60315A |SEAL-EPDM
+

BUCKET DISPEPOM 1 aa
1-25 6002-000471 |SCREW-TAPPING THMAL12STS304 2 |
DA66-30145A |LEVER-CUBE MSWR10,-.G-PUT.EPC3,DISPENSER 1
DA61-20139A SPRING-ICE.MAKER STS304I00.7,P 15. = 1
DA71-10010A REINF-ACTUATOR.DISP

21-29) 6002-000475 |SCREW-TAPPING THM4,L20,STS304


-30; DA63-00180A |COVER-ICE,BUCKET.A HIPP
21-31] DA63-00181A |COVER-ICE,BUCKET,B GPPS W9540B
DBE SOIISN (CASE DUCES MOTOR, ASSY HIPS, ET-PUT
DA67-00144A |CASE-MOTOR HIPP, AUGER i 1
DA31-10141D |MOTOR-GEARD

DA74-40154C |VALVE-SOLENOID

Ioa72-603480 SEAL-FOAM PE

GEAR-SOLENOID

SADOLE-SOLENOID
S7S304, L22, 002.8, 70.35 a

,
PLATE-D/AUGER, DISP $1$304

DA47-40112V UL-SPEC, PBT 5VA E14 Lae

22-17} DA39-00083A EXP, ET-PUT


VYOWHYVH
14-6) Freezer Room Door Exploded View (SR-S2026, $2027, $2226, $2227/S20NTC, S20BTC,S22NTC,S22BTC)

©
Hl
= Part List of Freezer Room Door Exploded View (SR-$2026, $2027, $2226, $2227/S20NTC,S20BTC S22NTC,S22BTC)
NO} CODE-NO Product Name Specification Quantity

DAS FOAM-DOOR FRE. ASSY EMBO, SC-$7527T S/WHITE. SOMM


1
DAS4-00604B |FOAM-DOOR FRE. ASSY EMBO. SC-975277 S/WHITE. 8oviM j Sait
goAR e 2B |HANOLE-TRIM, UP ABS, SC-97527R j C-TYPE
DA64-00176B |TRIMHANDLE CONNECT, UP
S& 5 ies) HANDLE-TRIM, MID ABS, SC-$7E27R :
DAS4-001778 TRIMHANDLE CONNECT. LOW =) A8S i
|] HANOLE-TRIM, LOW ABS, SC-97527R
=5
g:
oo SCREW-TAPPING FH2, M4x14,STS304
|
‘TYRE

Eee:
HANDLE-BASE, LOW HIPS
HANDLE HPS, SC-S7527R
—_— DA71-00056A |REIN-HANOLE. MD SBHGI, 11.4
12 | 6002-00470 _|SCREW-TAPPNG THA, M410. ZPC,SWRCHIBA
6002-00468 _|SCREW-TAPPING PHOS, MOX18 ZPOCYEL
DA71-C00684_| STOPPER-DOOR SPI, T3 BLK
5 |oreccorran [owns pom oe
6001-00715 |SOREW-MACHINE TH Mox16,ZPCCYEL), SWRCH'8A Ro

A63-30231G | GASKET-DOOR FRE ASSY SF-PVC, MAGNET-85g


sscomm
AB3-00191B |COVER-CONTROL. FRONT
ABS, SC-S7827R | tT
Fonesonana [oomrcora.e arse | |
FL

a
sr}fojerfofsewfea]{
|
am
orprmnNsi
Om;
&
w

monn [renpme (iar cpasy ||


oveetmnew [aoe (ws tt |
one3-002134 |GUAROBOTTLE FREUP HPP,SMM 1
DAse-00214A |GUARO-BOTTLE FRE. UP HIP, GNM =a
DAS300169A | GUARD-BOTTLE FRE. LOW
oo
DAS3-00169A | GUARD-BOTTLE rn& LOW
|
as

0A84-000978 | HANDLEBASE, L°
NS
NO}

OASACOIOOR |HANOLETAM LP ABSSCT |


DAS¢-000068_| HANDLE-BASE, iO
||
es
DA71-00077_| REINF-HANDLE. #2
DAS4-000068 |HANDLE-BASE. LO
RENF-HANDLE. H oes < i
LOW

HANDLE-TRM, 0
TRIMHHANDLE CONNECT. MO
14-7) Refrigerator Room Door Exploded View (SR-S2026, $2028, $2226, S2228/S2
S20DTC,0NTC,
S22NTC,S220TC)
°]
ia art List of Refrigerator Room Door Exploded View (SR-S2026, $2028, $2226, S2228/S20NTC,S20DTC,S22NTC,S22DTC)
NO} CODE-NO Product Name Specification

98 |FOAM-DOOR REF, ASSY EMO, SCSTSITT, S/WHTE SOWM SS SES


688 |FOAM-DOOR REF. ASSY EMBO, SC-V67T, S/WHITE SEMM
z/8|&28 |HANDLER UP ABS, SC-TBITT, SANHITE
ise) 0A64-001788 |TRIMMHANDLE. CONNECT, UP fon
DA6d-O0081A msscommsmme| 1 ||

a
6 |_bastani778 a ieee
HONOLETRM LOW [aes soem smere ||
jscrewrwepnc xtc | |
8
&|8
perce |WacesAc iow ws |

ni
©

oe
sewers | |
renrHnoLe MD [swsu | tT
jscrewaeenc [mixin sor |g]
le)
ealelels/s
Bliss
e BIE
/S|8 SCREW-TAPPING PHOS wexLie ZecvermanrR | 4 ||
|14|partowea [storpooR ss spak =| tt |
te | sopranos [soRewmoHNE [TH Mexte oven suaciren | 2 |
17 |0n6s-302326_|GASKETOOOR
REF.ASSY (SEAN MAE beaectet = al
vg8 onesooigsn_[coveuro
| lems | t_e
peegor7er |COMRGURD farsa | _( cg
DABS00G8A ee
UARO-BOTTLE REF. UP
= co

GUIDE-BOTTLE, REF PP, 125

S |
2 |
2
DAB400100A8 |HANDLE-TRIM. UP ABS, SC-G7527R |

DLE-BASE, MID ABS, SC-S7527R |


DA?1-00077A |RE F-HANDLE, MD
29 DLE-BASE, LOW
30 | 0A71-00078A |REINF-HANDLE, LOW
31 | 0A64-00088 |HANDLE-TRIM, MO 1
DASLOOIGEA [TRMHANDLE CONNECT.MO_ [aes
| |
14-8) Freezer Room Door Exploded View (SR-S2028, $2029, $2228, $2229/S20DTC,S20FTC,S22DTC,$22FTC) }
pF OTRETR
= Part List of Freezer Room Door Exploded View (5R-52028, $2029, $2228, S2229/S20DTC,S20FTC,S22DTC,S22FTC)
CODE-NO

ti
©
:
558 |FOAM-DOOR FRE, ASSY EMBO, SC-97527T S/WHITE.
© a 006648. |FOAMOOOR FREASSY vga. SC-VBUTT SWHTE, &
é S
3 ©
pesos [TRMHANOLE cowECT.UP es
x5
péd-000818
an pBtOoi77B |TRawaNoue connect.cow fas
Q!l9o = dT
HANDLE-TRIM LOW

We
=

g 938A |HANOLE-BASE, UP HPS

A {i

€/2|8|8oe
es so
FENEHANDLE MO FE leepee ce Lee
alg5/5 TPNG (TH, Max10.°C,SARCHIGA
s0020068 |SCREW-TAPENG Paesvexamov | a |
[4 |owrvoonan [stormncoon fomax tt |
ie i rr ae
|16|coonemoris |screwweorne | nexte ere simone | 2 ||
|18|onmsaniaie [oomrcowme. mor ||
eessomem
ones |covmcomme. 8 ome | |
2 |omer [rove tk premasy | ot |
HPP
DAGOZIMA |GUARD-BOTTLE FRE, UP
23 DAS3-001694 |GUBRO-ROTTLE FRE. LOW
DABS-0169A pee FRE. LOW
DAG7-00163A._ |CAP-CHLTE, ICE
DAS7-00162A. |CAP-CHUTE. CE

71.6 * 190 * 70
HIPS, K2007
DAG6-00087A | COVER-TRIMRECESS ABS, SC-97627,S/WHT
PP, T2
SC-97527,S/WHT
TRAY-DISPE NSER
LN SC-$7527,S/WHT
Indicated part is for electrical safety components
:[oom [verecee oame
me)art List of Refrigerator Room (SR-S2028, $2029, $2228, $2229/S20DTC,S20FTC,S22DTC,S22FTC)

34 | DABt-00086A [LEVER-DSPENSER, ICE | ABS,SC-S7507R 1


35 |oasscmnsea |Leveosr, sue |sticON Saat 2 —
36 | 0871-00073 |SPRING-LEVER DISP, WATER sue 72 ft PO
37 | DATI-O0I81A_ |LEVER-DISPENSER,WATER resscam =f tf
38 | 0A71-000728 |STOPPER-LEVER ero ft fl

Poa [annie Javosenen [1


39 | 0067-00163 |GUIDE-LEVER resscamarza =f tf

41 | DA74-10268) | VALVE-SOLENOID CUBE-SN2,SR-S8586B,220-24 Ce. a


42 | DA61-70234A | SUPT-TIME DELAY HIPS S/WHT 71 eae
3402-000t65 |SWITCH-DISPENSER DECO 250VAC 6A 1 —
WIRE-DISPENSER S/W
ee
14-9) Refrigerator Room Door Exploded View (SR-S2027,S2029, $2227,$2229/S20FTC,S22BTC,S22FTC)
a Part List of Refrigerator Room Door Exploded View (SR-S2027,$2029, $2227,$2229/S20FTC,S
22BTC,S22FTC)
NO} CODE-NO Product Name Specification Quantity) Remark
DAS1-006598 |FOAMDOOR REF, ASSY EMBO, SC-S7527T, 50VM FUSER

i
DAS1-006568 FOAMAOOOR REF, ASSY EMBO. SC-STBOTT 85MM RINT ry C

DA64-000828 |HANDLE-TRIM, UP ABS, SCSTEQIR. S(WHTE ‘D’-TYPE


DAG4-00176A |TRIMHANDLE CONNECT. UP [ABS Nor
DA4-0008 =[ou] HANOLE-TRIM, MID ABS, SCSTSQIR. SHITE
5
L
A64-00177A TRIMHANDLE CONNECT, LOW ABS NeOr

::
l HANDLE-TRIM, LOW ABS, SC-O7527R. SAWHITE
SOREW-TAPPING FH Max14,STS304 i
DA64-00083A |HANDLE-BASE, UP
f
ae
© =x

i
ABS, SC-97827R, S/WHIE
=
a

a: = iw) SBHGI, 71.4


6002000470 |SCREW-TAPPING

:
TH+, M4x10,2PC, SCRCHIBA 3

PH+2S, MoxL18 ZPC(YEL), MAWR

Ea
14 DA71-00068A SPI, 73 BLK
~

6 DAG4-00122A CAM-HINGE POM, 640788


8 | 6001-00715 | SCREW-MACHINE TH MOx16, ZPOCYEL), SWRCHIBA
[al
3 2
fe

17 | DA63-30232G | GASKET-DOOR REF, ASSY SF-PVC, MAGNET-86g


a

DAS3-00199A | COVER-GUARD GPPS, 50MM 1


DA63-00176A | COVER-GUARD FE
DAG63-00168A GUARD-BOTTLE REF, UP
— FLEEAC
| DA63-00167A GUARD-BOTTLE REF, UP FE SAC
DA66-90112A TRIM-GUARD

DA71-00000A |GUIDE-BOTTLE. REF

DA63-00173A |GUARD-BOTTLE REF, LOW


Fs OE COE
DA63-00172A | GUARD-BOTTLE REF, LOW

DA61-00108A
Indicated part is for electrical safety components
NO! CODE-NO Product Name Specification Quantity} |Remark

2A DA67-00304A |HOME-BAR,FOAM SC-97527T S/WHITE 1

2 DA66-00089A |ARM-HOME BAR R,ASSY ee 1

Haag) DA67-30271A | CAP-HOME BAR, ARM NY-60, S/WHITE 2

2]

28

23

3
,
:
:
=< re)
olaTs) = o (*) = w oc°ors}£ <x42)i?oO£ = (79)Q.@ oO= o cS= Soc

15-1) Please remove fixed screw of cover of machine room of Refrigerator rear low part.

WYK
AEN
QO
ACS
©
X,
LaO®
°
®

15-2) Machine Room Assembly Specification

Electric Field Box


Lis
Y

Condensing Unit

Cooling Fan
16. Disassembly & Assembly Method of Internal Part of Electric Field Box

15-1) Please cut-off the power supply of refrigerator. )

(+) driver

PCB-MAIN ASSY
17. Installation Method of Water Supply Tube

10; Check the amount of supplied water toe icemaker: (The Method to control the amount of water supply to the ice maker]
1) Remove the upper ice maker
from the refrigerator. 1. First, change control panel to option change mode.
Press “Freezer Temperature” button and “Vacation” button simultaneously for about 12
seconds, temperature display will change to option change mode with beep

2. The number of right display, refrigerator temperature display, is the kind of option. Press
“Refrigerator Temperature” button, the number increases. Also, press “Vacation” button,
the number decreases. Set the number to 3.

3. The number of left display, freezer temperature display, is the data of each option. Press
“Freezer Temperature” button, the number increases. Also, press “Quick Freeze” button,
2) When the test button is pressed, the ice cube container is turned and then water is the number decreases.
out from the tap of the ice maker where water is supplied. At this time, check the Set the number to desired number, two digit, as reght table.
amount of water.(see the picture)
If there is over-supply of water, the ice cube will be made in attached form of 2 to
4 ice cubes. If there is less-supply of water, the ice cube will be made in small size.
When this happens, you may encounter inconvenience while using. This is not a
problem in the refrigerator. It is the problem of water pressure in the water pipe
and occurs frequrently. When this problem occurs, control the amount of water
supply by the following method.
the amount of water

vets we 4. Setting the option and data, please wait until control panel is changed to the control mode
automatically.

:Notice ea
;When setting the amount of water
- supply, do not select the large amount
'of water supply. Set step-by-step.
(Water can be over flowed.)

5. If the option control is completed, check the amount of supplied water in the Ice Maker.

CHECK OF THE SUPPLIED WATER

If the controlled amount of water supply is slightly below the optimum level, it is O.K. to use.
18. Installation of the water dispenser line

1) For automatic operation of the ice maker, water pressure of 1.4~4.5 kgf/ai is required.(It is 2. Connect the water tube to the conpler 6. Fix the purifier.
acceptable if the disposable paper cup(180cc) can be filled up with water within 10 second.)
2) The water tube can be used by cutting to the desired length. Make sure that the tube is not Insert the waterfube into the conpler. 1) Fix the purifier as shown int he TER TL EES
bent. picture on the right.
3) Make the maximum length of the water tube to be 12m, if possible. If the length is over 12m,
it will cause a problem to supply water because of decrease of water pressure.
4) Locate the water tube at the area without heat.
5) The purifier is just for filtration. It will not work as sterilizer of microorganisms.
6) If the refrigerator is installed in the area with low water pressure(below 1.4 kef/at),
additionally purchased booster pump may be installed in order to compensate the shortage
of pressure. PURIFIER LOCK
STATION
7) The life cycle of purifier depends upon the condition of the usage, but we recommend that
you change it every 6 months. So we recommend that you install it at the place to access
easily for changing.
8) To supply water to the storage tank inside the refrigerator, press the cold water button for 3. Select the purifier location for installation 7. Connect the water tube to the refrigerator.
about 2 or 3 minutes and make cold water drop from the cold water outlet.
1) Select the location of the purifier. 1) Remove the back cover of BACK COVEROF CONNECT NUT
9) In order to avid possible leakage, seal every joined area using sealing tape. 2) Cut water tube considering the
A TUBE INLET SIDE TO PURIFIER
the refrigerator. REFRIGERATOR
10) The water tube should be connecfed to the cold tap water. distances between Purifier and 2) Connect the water tube to —WATER TUBE
waterworks tap, and Purifier and the valve as shown in
# Check the components water valve of Refrigerator the picture.(The connector is
(At this time, it must be cut at a located at right side of the
reght angle.) machine room in the back of
Sealing Tape
(0203-00399)
3) Insert water tubes of inlet side and the refrigerator.)
outlet side of Purifier. 3) When connected, check
whether there is any leakage.
A On leakage, reassemble them.
A TUBE INLET SIDE TO PURIFIER

a
Rubber packing .
iit

Wyn <=,
Clip AX8EA 4. Remove the residuals inside the purifies. 8. Put the water tube in order
Screw-tapingX12EA (DA65-20110B)
(6002-000213)
1) Open the main water valve to 1) Using the clip “A” and “B” fix
i WI
He
J eae
ve? check whether water is running the water tube to the wall.
Purifier.... 4 be ee
ae, \ BPE i through the water tube from the 2) When the water tube is put in
(DA29-10105B)
water inlet side of the purifier. order, make sure there are any
Si FES ra Purifier lock 2) Leave the faucet open until clean forced bending and pushing
: i; station
(DA73-10466F) water is running out. against the water tube.
Tightening band (6502-000156)

WATER TUBE
1. Connect coupler to the water tap. A OUTLET SIDE OF PUFIFIER
The water tube should be connected
1) Close the main water tap. to the cold water pipe. If it is connected
2) Connect the coupler to the tap water. to the hol water pipe, it may cause
some problems in the Functioning of
3) Every joint should be taped with sealing
tape.(see the picture)
5. Fix the purifier lock station. 9. Complete the installation of the water dispenser line

1) Hold the purifier lock station 1) Turn on the refrigerator and press
against the lock hole of right- the left side lever until water is
+ If the coupler doesn’t fit to lower side in the back of the coming out through the water
the existing water tap, consult the
refrigerator and fix it tightly tube.(approximately 2~3minute)
closest authorized service dealer and
purchase the right couplers for the
using screw. (Press it until the initial air outing
proper installation.
purifier lock station phenomenon disappear.)
2) At this time, check any possible
purifier lock station leakage on the joints of the water
tube. After putting the water
tube in order, move the refrigerator
to the desired location. Once the
refrigerator is located, do not move
the refrigerator as possible.
19. PCB circuit diagram and Service Components LIST

L N ae -
tk SMPS
wel |
[rare | - e@
ae
sop
shad wey eek nol. MAIN PCB
|
te in
: ode Ls ee
:
i s

at + me ' tz
pa CHOKE COIL
l
PANEL PCB
o s 180)
|me Dae oto SS BO
ws
Bee
T=] 4 sy [2 Be
GUN
i
™ VARI
3 i
—t
OC
ag pas

wi
DHODOOO
OOOO

CN70
YW396-094V WHT
teopBiiicc case on pSeae eee eS ete!
REO: ESV} F-DET HEATER QUICK FREEZE S/W)

THERMAL FUSE.

~Ooxt© *(-OEF-HET) ms
REL ES

Pl cca
ae ala pe? eae
HOML BAR HEATER
(id)0
bag sued Por
2

Soaarns
ACD:

BL
1 (5)0< 2) (7) P10
‘ RCO
J
H AFD a 1CE_SOLENOI-VALVE a
1
' amy
1

ate oo AUGFR MOTOR


' 3
i CUBE SOLENOID-VALVE
1
1
O} |© cN71
YW396-09AV REL
i
1
' UDN2981A,KID657B3AP KIDES003AP TRANSISTOR
1

ICE MAKER KIT


‘KS0880-Y

'
'
'
'
'
'
TMP87CK40N

'
=)
u ‘

1N4007=4-0705 ac] R709 A708 ZA707 CFAN HIGH


5g ;

ig [nt
we one, | 1 HORIZONTAL S/W
R714 ANSE SRI RIG 10K 03 F-FAN 4
POK-F 10K-F 2 TOK aT G2)Pe
'
O~ oO
( ACEAEVER S/W

A ea
()
ae [ere 3 4
1
5 ives a 1
@
Cy ge ee a eee reer 207032ZD702ZD701 ‘

N30 vec aw
Sve wr Le ne (05) Pee
C205 Dispenser type
Hf g 8 a

CO
©_
bisa R403 =
oa nr
WA ME) PES

1A

a3 #8
R38
OOO
© oe cme | 2S)
2LaN3?
Pac
CIRCUIT DIAGRAM
CN31
‘SM4WW250-02_ WHT

OO
20. Specification of Principal Part of Circuit

20-1) REGULATOR OC
RA
s
most
3-TERMINAL 1A POSITIVE
TO-220
|
i
VOLTAGE REGULATORS !I

The KA78XX series of three-terminal


positive regulators are available in the TO-
220 package and with several fixed output es, |
voltages, making them useful in a wide See,

range of applications. Each type employs


internal current limiting, thermal shut-down Be 7 Ae i
and safe area protection, making it | ; SE, sea

essentially indestructible. If adequate heat : Re A |


sinking is provided, they can deliver over !
|
t

1A output current. Although designed |


primarily as fixed voltage regulators, these
devices can be used with external
components to obtain adjustable voltages tinput 2GND = 3:Output
and currents. Aa ht SP eet St

= ORDERING INFORMATION

tier
us FEATURES
* Output Current up to 1A Operating Temperature |
¢ Output Voltages of 5; 6; 8; 9; 10; 11; 12;
15; 18; 24V KA78XX |TO-220,
Tes 0~ 4125 !
* Thermal Overload Protection KA78X O- 20| zl
¢ Short Circuit Protection
* Output Transistor SOA Protection KA78XX| |TO-220 -40~ +1250 _ |

« BLOCK DIAGRAM

INPUT

Oo
1
'
|

CURRENT SOA
: GENERATOR PROTECTION

| STARTING REFERENCE ERROR -


CIRCUIT VOLTAGE AMPLIFIER 4

$
|
THERMAL
PROTECTION
| GND
| O —O
ABSOLUTE MAXIMUM RATINGS (1.=25'c unless otherwise specified)
|
eeCharacteristic
Input Voltage (for
Vo = 5V to 18V) 35
(for Vo = 24V)
Thermal Resistance Junction-Cases
Thermal Resistance Junction-Air

Operating Junction Temperature Range KA78XX/A 0~ +125


KA78XXI -40 ~ +125
Storage Temperature Range

ELECTRICAL CHARACTERISTICS KA7805/I


(Refer to test circuit, Taw < Ts < Tux, lo = 500mA, Vi = 10V, Ci = 0.33yF, Co = 0.1yF, unless otherwise specified)

KA78051 | KA7805 ;
Characteristic Test Conditions - Unit
Min Typ |Max|
Min]Typ[Max

Output Voltage 5.0mA < 1.0A, Po < 15W


Vi=7V to 20V
Vv: = BV to 20V .

|) W=7Vt025V
Line Regulation
Vi=BVto 12V Tie
| lo=0.5mA to 1.54
Load Regulation AVo
[a = 250mA to 750mA

Quiescent Current lo Ts = 25°C


lo= 5mA to 1.0A

Quiescent Current Change Alo Vi= 7V to 25V }0.3/1.3 | mA


Area |
Vi= 8V to 25V 0.3} 1.3 |
Output Voltage Drift AVod AT lo = 5mA -0.8| -0.8 ! mV/C
Output Noise Voltage Vn f = 10Hz to 100KHz Ts = 25°C 42 42 | 2 2N
Ripple f = 120Hz |
RR 62 |73 62 |73 BB
Rejection Vi= 8 to 18V
Dropout Voitage Vo lo= 1A, Tr = 25°C le 2 | V
Output Resistance Ro | f = 1KHz 15 15 | mQ
Short Circuit Current Isc Vi = 35V, Ta = 25°C 230 230 mA
Peak Current lex Ts= 25°C 2.2) 2.2 i A |

* Ten « T: « Tax

KA78XXI : Twn = -40°C,


Tuax = 125°C
KA78XX, Tun = OC, Tux = 125°C
* Load and line regulation are specified at constant junction temperature.
Changes in Vo due to heating effects must be taken into account separately.
Pulse testing with low duty is used.
ABSOLUTE MAXIMUM RATINGS (1.= 25° unless otherwise specified)

Input Voltage (for Vo = 5V to 18V)


(for Vo = 24V) V
Reic | ‘CW

[8 | ew]
Thermal Resistance Junction-Cases

Operating Junction Temperature Range KA78XX/A 0~+125 Cc


KA78XX\ 40~4125 °°
Storage Temperature Range -65 ~ +1 50° 1 Cc 7

ELECTRICAL CHARACTERISTICS KA7805/i


(Refer to test circuit, Tam < Ts < Twax, lo = 500MA, Vi = 10V, Ci = 0.33¢F, Co = 0.14F, unless otherwise specified)

Min
Ts = 25°C 4.8) 5.0} 5.2
Output Voltage Ve 5.0mMA < 1.0A, Po < 15W
Vi = 7V to 20V : .0 (5.

Vi = 8V to 20V ; |
Line Regulation AV ; moc AV
9 |100) | 9 |100,
Load Regulation AVo

Quiescent Current lo Ts = 25° T5.0 8 | to ~ |


lo = 5mA to 1.0A 05; 0.0305|
Quiescent Current Change Vi = 7V to 25V j [0.3/1.3 | Alo |
| ! Vi= 8V to 25V ie ee
Output Voltage Drift AVdAT | lo = 5mA 08] | [0.8] AV/AT)
Output Noise Voltage lv | f = 10Hz to 100KHz Ta = 25°C [42 | Ve |
Ripple - f = 120Hz ae ae |
Rejection Vi = 8 to 18V ae ee Cee eee
Dropout Voltage Vo | lo = 1A, Ts = 25C 2 | 2 i Ve
[
Output Resistance TOR | f = 1KHz |15 [ 115; of Re 1
Short Circuit Current a lc | W=85V, Ta= 25°C [230/ [jeaol bse
Peak Current 1 VK T= 25C 12.2 [2.2 Vex |
+ Tun < Ta < Teax
KA78XXI 2 Twin = -40C, Toax = 125C
KA78XX, Twn = 0'C, Tex = 125°C
+ Load and line regulation are specified at constant junction temperature.
Changes in Vo due to heating effects must be taken into account separately.
Pulse testing with low duty is used.
ELECTRICAL CHARACTERISTICS KA7812/I
(Refer to test circuit, Tun < Ts < Tux, lo = 500MA, Vi = 19V, Ci = 0.33nF, Co = 0.1xF, unless otherwise specified)

Characteristic Test Conditions


|Min]Typ Max! Minj Typ Max)
| T. = 25°C 14.5] 12 12.511.5! 12 12.5)
Output Voltage Ve | 5.0mA < 1.0A, Po < 15W} | i Vv
Vi = 14.5V to 27V 14 12 126
Vi= 15.5V to 27V 11.4) 12 12.6

Line Regulation
W= 14.5 to 30V /10 [240] | 10 [240
/ mV
Vi= 16 to 22V 3.0 /120 13.01120 |

Load Regulation
lb=SmAto15A | [11 [240] | 11j240]
mV
lo=250mA to 750mA 5.0/120 5.01120
Quiescent Current lo Ty = 25°C 5.1] 8 5.11 8 mA
| fo=SmAto1.0A =| —-: 10.1] 0.5 0.1/0.5 |
Quiescent Current Change | Allo Vi = 14.5V to 30V 1.0! mA
Vi= 15V to 30V 0.5| 1.0
Output Voltage Drift | AVol AT lo= 5mA 1 i-1 ! mV/'C
Output Noise Voltage Vw | f=10Hzto 100KHz,Th=25'C! | 76 | 176 | wv
Ripple | f = 120Hz |
ee RR 55 |71 55 |71 | dB
Rejection Vi = 15V to 25V: [4 |
Dropout Voltage Ve lo= 1A, Ts = 25°C 2 i eet
—1 —- u —+— a
Output Resistance Ro f= 1KHz 18 18 mQ
Short Circuit Current le | | Wi=85V, Ta= 25°C 230 | 1230 mA
Peak Current li Meer T= 25°C 2.2 te 12.2 | A
* Twin < Ts < Tax

KA78XXI : Tw = -40°C, Twax = 125°C


KA78XX, Tun = OC, Tux = 125°C
* Load and line regulation are specified at constant junction temperature.
Changes in Vo due to heating effects must be taken into account separately.
Pulse testing with low duty is used.
20-2) RESET IC (KA7533)RED POEL a NE INN RINE AT BAIS STN Id7 ECE OAR FLT SEE EE INET RENE NO OEE: AUS UNRAR A TA OH re”

3.3V VOLTAGE DETECTOR | TO-92


The KA7533 prevents error of system from
supply voltage below normal voltage level
at the time the power on and instantane
ous power off in systems.

« FEATURES
* Detecting against error operations at the
power ON/OFF.
+ Resetting function for the low voltage
microprocessor.
* Checking low battery. 1:Input 2:GND 3:Output
= sa Se a haces

r ORDERING INFORMATION
| Device Operating Temperature |
|KA7539Z |TO-92 | -30~ 475°C

7
'
i
|
|
i
« BLOCK DIAGRAM
|

- ©
Vec
(INPUT)

GND
ns ABSOLUTE MAXIMUM RATING (= 25)
Characteristic
Supply Voltage
Detecting Voltage
Hysteresis Voltage
Operating Temperature
Storage Temperature -50 ~ +150
Power Dissipation 200
Detecting Voltage Temperature Coefficient

= ELECTRICAL CHARACTERISTICS (1-25)


Max Unit
Detecting Voltage Vosr Ri= 2002, Va < 0.4V 315 | 33 | 345 | Vv
Low Output Voltage Ri = 200Q 02 °° V
Output Leakage Current Vee = 15V 01 | WwW
Hystersis Voltage Ri = 200Q 30 50 100 mV
Detecting Voltage
Temperature Coefficient
Ri = 200 2 +01 %IC
Circuit Current (at on time) Vee = Voetoun-0.05V
Circuit Current (at off time) Icom Vee = 5.25V - 30 50
Threshold Operating Voltage | Vaworm | Ri= 2002, Va < 0.4V 0.6 0.8 1.0 V
“L” Transmission Delay Time} To | Ri=1.0KQ, C= 100pF 10 15 “S
“H” Transmission Delay Time} Tow | Ri=1.0KQ, Ce= 100pF 15
or |

20 4S
Output Current (at on time [)} Tou: Vee = Voerwmn - 0,05V, Te = 25°C 10 18 28 mA |
Output Current (at on time ])| Voc = Voeraany - 0.05V,
Tour sn ge 30 mA
Tc = -30 ~ +75
20-3) DRIVER IC (KID65783AP) ;

KEC
KOREA ELECTRONICS CO.,LTD,
SEMICONDUCTOR | KID65783AP/AF
TECHNICAL DATA BIPOLAR LINEAR INTEGRATED CIRCUIT

8CH HIGH-VOLTAGE SOURCE DRIVER

The KID65783AP/AF is comprised of eight source current transistor array.


This driver is specifically designed for fluorescent display applications.
Applications include relay, hammer and lamp drivers.

FEATURES
+ High Output Voltage : Vec=50V(Min.).
Output Current (Single Output) Iour : -500MA(Min)
® PIN CONNEASTION (TOP VIEW)
«Output Clamp Diodes.
- Single Supply Voltage.
+ Input Compatible With Various Types of Logic.
+ Package Type-AP : DIP-18pin.
«Package Type AF : FLP-18pin.

DESIGNATION
KID65783AP/AF | ‘TTL, 5V CMOS
MAXIMUM RATINGS (Ta=25°C

Saas
CHARACTIC SYMBOL

Cc a
Prats
Cantino | vw | a |
Cenpdni Fanon | | 0 | ¥at

Power Dissipation pe W : x KID65783


:n=1
Porat,
Operating Temperature
Storage Temperature
(Note) The input and output parasitic diodes cannot be used as clamp diodes.

w ELECTRICAL CHARACTERISTICS(Ta=25°C ,Vcc=5V)


CHARACTERISTIC SYMBOL TEST CONDITION min. |TYP. |MAX. |UNIT
Output Leakage Curret Icex ei Vee=Vee wax. Vin=0.4V Ta=25C fi : 100 uA
Vin = Vin(ON), lout = -350MA, : : 2.0
Output Saturation Voltage | Vce(sat) 2 Vin = Vinton). lout = -225mA - | - [a9] v

Vin=2.4V = 36 52 uA
Input Current Iin(ON) 3
Vin =3.85V - 199 260
hw (on) Vet =2.0V, lout = 1350mA : : 20
input Voltage 4
lin(OFF) lout = -500uA 08
Supply Current ln(ON) 3 Vin = Vin(on), Vcc = 50V : : 25 |maAfen
Clamp Diode Reverse Current 5 va=50V : - 50 et
7 —
CGtamp Diode Forward Voltage 6 IF=350MA ae 20 ¥
Turn-On Delay Vec=Vec max, AL = 1252 -_ | 215 : 7
Turn-Off Delay £ Ci=15°F > 18 us
20-4) DRIVER IC (ULN2003A) )

HIGH-VOLTAGE, HIGH-CURRENT
DARLINGTON ARRAYS
Ideally suited for interfacing between low-level logic circuitry and multiple
ULN20XXL peripheral power loads, the Series ULN2000A/L high-voltage, high-current
Darlington arrays feature continuous load current ratings to 600 mA for
each of the seven drivers. At an appropriate duty cycle depending on
ambient temperature and number of drivers turned ON simultaneously,
ULN29XXA typical power loads totaling over 260W(400mA x7, 95V) can be controlled.
Typical loads include relays, solenoids, stepping motors, magnetic print
hammers, multiplexed LED and incandescent displays, and heaters. All
devices feature open collector outputs with integral clamp diodes.

The ULN2001A device is a general-purpose array that may be used with


external input current limiting, or with most PMOS or CMOS logic directly.

The Series ULN20 x3A/L has series input resistors selected for operation
directly with 5V TTL or CMOS. These devices will handle numerous
interface needs-particularly those beyond the capabilities of standard logic
buffers.

Dwg. No. A-9594 The Series ULN20 x4A/L features series input resistors for operation
directly from 6 to 15V CMOS or PMOS logic outputs.

The Series ULN200 xA/L is the standard Darlington array, The outputs are
ABSOLUTE MAXIMUM RATINGS | capable of sinking 500mA and will withstand at least 50V in the OFF state.
Outputs may be paralleled for higher load current capability. The ULN2013A
Output Voltage, V-¢ device is similar except that it will sink 600mA. The Series ULN202 x A/L
(ULN200X", ULN2013A) ........ 50V will withstand 95V in the OFF state.
(ULN202X") oo eeeeeseecccescenssens 95V
Input Voltage Viy ...ssssseccscesssseses 30V These Darlington arrays are furnished in 16-pin dual in-line plastic
Continuous Output Current, |,
(ULN200X*, ULN202X") ... 500mA packages (suffix A) and 16-lead surface-mountable SOICs (suffix L). All
(ULN2013A) .....esssssssssssesse 600mA devices are pinned with outputs opposite inputs to facilitate ease of circuit
Continuous Input Current, |,.... 25mA board layout.
Power Dissipation, Pp
(one Darlington pair) ............. 1.0W
(total package) ........... See Graph
= FEATURES
Operating Temperature Range. + TTL, DTL, PMOS, or CMOS Compatible inputs
Tyheseadtiins ashacess -20C to +850 + Output Current to 600mA
Storage Temperature Range, + Output Voltage to 95V
iPonnewreere renee? -55C to +150 * Transient-Protected Outputs
« Dual In-Line Plastic Package or Small-Outline IC Package
Note that the ULN2000A Series (dual
in-line package) and ULN2000L
series (small-outline IC package) are
electrically identical and share a X = digit to identity specific device. Characteristic shown applies to family of devices with

P07)
common pin number assignment. remaining digits as shown. See matrix on next page.
Es
| PARTIAL SCHEMATICS
Vogimax) 50V 50V
ULN2001A (Each Driver)
lian) 500mA 600mA
© COM Logic Part Number
General Purpose
PMOS, CMOS ULN2001A*
5V ULN2003A* ULN2023A*
Dwg. No. A-9595 TTL, CMOS ULN2003L* ULN2013A* | ULN2023L
6-15V ULN2004A*
ULN20X3A/L (Each Driver)
CMOS, PMOS ULN2004L* ULN2024A
“Also available for operation between -40°C and +85'C.
To order, change prefix from ‘ULN’ to ‘ULQ’.

Dwg. No. A-9651


t

ULN2OX4AVL (Each Driver)

ALLOWABLE
PACKAGE
DISSIPATION
POWER
IN
WATTS
Dwg. No. A-9898A
AMBIENT TEMPERATURE IN ‘C
Dwg. No. GP-006

x = Digit to identify specific device. Specification shown applies to family of devices with
a remaining digits as shown. See matrix above.
20-5) RELAY (VSB-12TB) )
A EAE © © @
16 Amps. Miniature
Slim Type Power Relay

= FEATURES
+ All or Nothing Relay
* UL, CSA, VDE, SEV, SEMKO, IMQ,
OVE, BSI Recognized
* Working Class : C
+ Type of Service : Continuous Duty
* Heavy Duty 16A Miniature Power Relay
¢ UL Class B(130°C) Insulation
* High Isolation in Small Package
- Insulation Distance : 8mm
- Dielectric Strength : 5,000VAC
(between coil and contacts)
- Surge Strength : 10,000V
« Low Power Consumption and Stationary Contact
high Sensitive Type Available (VSB-S) Terminal(Break)

* Washable (With Tape) Type Available

= SPECIFICATIONS
CONTACT GENERAL
+ ATTANGEMENE o..tecescsseseesee 1 Form A (SPST-NO) or + Insulation Resistance ........... Min. 1,000M2 at 500V0C
1 Form C (SPDT) + Dielectric Strength... 1,000VAC 1 minute
1] cc Silver alloy IMQ (2 {between open contacts)
* TYPO wees . Single Type 5,000VAC 1 minute
+ Resistance {initial) .. Max. 200mQ (at 6VDC 1A) (between coil and contacts)
+ Ratings (resistive) + Surge Strength .....c-secssesseeses 10,000V
Nominal L0ad w.........ssseeee. TBA 250VAC or 30VDC IMQ Ww {at 1.2 x 50x standard surge wave)
Max.Switching Power... - 4,000VA, 480W + Temperature Range................ Standard Type + 30°C to +65'C
Max. Switching Voltage . . 880VAC, 150VDC {at nominal Voltage) High sensitive Type :-30'C to+75'C
Max.Switching Current . 16A © TIME VANUC cao eecsessseccscecssssees Operate Max. 20ms
Max.Carrying Current ............. 16A (at nominal voltage) Release Max. 10ms
Max. Switching Load(+1) ......... SVDC 100mA + Vibration Resistance
« Life Expectancy te)9)-1¢-11
6) 10 to 55 Hz,
MECHANICA .....-.s.sscsseseerneecenee OX 10° operations double amplitude of 1.5mm
ELOCHICAD ..seeseosssesseeusssesenseees 1X 10% operations (at nominal load) ENMQUTANCE os ecessesseeseessseeseseeee 10 to 55 Hz,
double amplitude of 1.5mm
COIL + Shock Resistance
+ Nominal Voltage eevee 310 100VDC MiSOPerAatiON ne nrcreeeenrens 100 mis’ (11 1ms)
+ Nominal Power (at 20C).......... Standard Type 0.70 0. 0.75W Endurance . 1,000 ms? (6+ fms)
High sensitive Type : 0.53W * Unit Weight . Approx. 189
* Operate Power (at 20°).......... Standard Type = 0.35 to 0.37W # ENCIOSULE wossesssseseessesseseseceesseee Polybutylene Terephthalate(PBT)
High sensitive Type : 0.26W eee ;
* Operate & Release Voltage ... Please see Coil Data Chart Sapa eens bey epg rovesaiedeesenea bane ache =e
+ Max. Contious Voltage .........-.. Please see Characteristic Data according to switching frequencies, environmental conditions and expected feliability levels.
«SAFETY STANDARD &
FILE NUMBERS
UL 508 (File No. £56140. E108658)
C22.2 No.0, No.14 (File No. LR35579)
VDE 0435, 0631, 0700
VSB [310100VDC| 16A 30VDCI25OVAC, Resistive
Please be noted that UL/CSA rating may Pilot duty
C150 |
differ from the Standard ratings.
Please request when the approval
markings are required on the cover.

« ORDERING INFORMATION
VSB-12STB -— Enclosure
B_ : Flux Free Type
© : Washable Type (with tape)
Contact Arangement
M_ : 1 Form A (SPST-NO)
T :1 Form C (SPDT)
Coil Sensitivity
Ni: Standard Type
S _ : High Sensitive Type
Nominal Voltage
Type
Note) 1. Actual making omits the hyphen (-) of («)

«COIL DATA CHART


Coil Nominal Coil Resistance Must Operate Must Release Coil Nominal
ORDERING CODE Voltage Q+10% Voltage Voltage Power
VDC (at 20°C) V DC (at 20°C) V OC (at 20°C) W (at 20°C)
3 12.5 21 0.3 U.72
5 36 3.5 0.5 rao
© 50 5 } tr?
2. 115 c r 01.50
ra 84 12 0.79
ig 14 0.70
So 1.8 x70
no
Cc 2.4 U.70
S 25,9 3.6 6.50
” 4.8 Ort

6.0 0.70
a)

Sensitive
High
Type
A Safety Instruction on Service

@ Unplug the refrigerator before making any repair or any replacement.


C> Avoid the electric shock.

@ Use the rated components on the replacement.


[> Check the correct model, rated voltage, rated current, operating temperature and so on.

@ On repair, be sure that the wires such as harness are bundled tightly and are not
permeated by water---
> Bundle wires tightly in order not to be detached by the external force.

@ On repair, remove completely dust, particles or other things on housing parts, harness
parts, and check parts.
t> Cleaning may prevent fire by tracking or short.

@ Check if there is any trace indicating the permeation of water.


C> If there is that kind of trace, change the related components or do the necessary
measure such as taping using the insulating tape.

@ After repair, check the assembled state of parts.


c> It must be in the same assembled state when compared with the state before
disassembly.

@ Check the surrounding conditions of the installed refrigerator.


Cc» When the refrigerator is located at humid or wet place, or the installed state is unstable,
change the location. ,

@ If needed, do the grounding


> Especially, if there is a possibility of the electric leakage, this appliance must be
properly grounded.

@ Do not allow consumers to use one consent for several plugs.

@ Check whether the power cord is placed under other appliance and so, damaged, frayed
squeezed.
->Repair immediately the defective power plug or consent.
=>Make sure that the power cord does not come to be placed under other appliance or
squeezed.

@ Do not allow consumers to keep bottles or the likes in the Freezer Room or to keep foods
in unstable state.

@ Do not allow consumers to repair the appliance for themselves.

@ Do not allow consumers to keep other things except food.


>>Medicines and other materials for research : this appliance will not maintain the Strictly
controlled condition.
=>Volatile material(alcohol, benzene, ether, LP gas etc.) : possibility of explosion