micro-tech
micro-tech
2 MICRO-TECH
SELF-EXPANDING STENTS SIMPLE TO RELEASE
Every stent from the MICRO-TECH Endoscopy In order to make release of the stent as
range is manufactured using high quality Nitinol easy as possible, the stents are preloaded
wire. The “thermal memory effect” of Nitinol causes on an introducer. The system can be ma-
the released stent to unfold into its predetermined nipulated intuitively and effortlessly. With
dimensions at body temperature. It therefore some stents you even have the opportu-
adapts to the anatomy and achieves the desired nity to correct the positioning of the stent
dilation of the stenosis in an optimum manner. during implantation.
MICRO-TECH 3
TRACHEAL AND BRONCHIAL STENTS
THE RIGHT SOLUTION FOR EVERY INDICATION
Through its diverse selection of self-expanding stents different lengths varying from 20 to 80 mm are avai-
for the respiratory tracts, MICRO-TECH can provide the lable. The stent’s spherical ends as well as their high
right solution for every indication. All in all, six different radial force ensure a firm hold and minimize the risk of
diameters ranging from 10 to 20 mm in addition to six migration.
SPECIFIC CHARACTERISTICS
• Self-expanding
• Nitinol mesh with atraumatic ends
• Excellent positional stability
• High radial force
• Resistant and elastic covering
• Fully covered stents available
• High radiopacity
• Guide wire-compatible up to 0.035 inches Spherical end Elastic covering
4 MICRO-TECH
SUCCESSFUL IN PRACTICAL USE
MICRO-TECH 5
SIX DIFFERENT DIAMETERS
ø 10 mm ø 12 mm ø 14 mm ø 16 mm ø 18 mm ø 20 mm
80 mm 60 mm 50 mm 40 mm 30 mm 20 mm
SPECIFICATIONS
ST05-102.10.020 10 12 20 10
ST05-102.10.030 10 12 30 20
ST05-102.12.020 12 14 20 10
ST05-102.12.030 12 14 30 20
ST05-102.12.040 12 14 40 30
ST05-102.14.020 14 16 20 10
ST05-102.14.030 14 16 30 20
ST05-102.14.040 14 16 40 30
ST05-102.16.040 16 18 40 30
ST05-102.16.050 16 18 50 40
ST05-102.16.060 16 18 60 50
6 MICRO-TECH
REF Ø centre mm Ø end mm Length mm Covering mm
ST05-102.16.080 16 18 80 70
ST05-102.18.040 18 20 40 30
ST05-102.18.050 18 20 50 40
ST05-102.18.060 18 20 60 50
ST05-102.18.080 18 20 80 70
ST05-102.20.040 20 22 40 30
ST05-102.20.060 20 22 60 50
ST05-102.20.080 20 22 80 70
ST05-103.08.020 8 10 20 20
ST05-103.08.030 8 10 30 30
ST05-103.10.020 10 12 20 20
ST05-103.10.030 10 12 30 30
ST05-103.12.020 12 14 20 20
ST05-103.12.030 12 14 30 30
ST05-103.12.040 12 14 40 40
ST05-103.14.020 14 16 20 20
ST05-103.14.030 14 16 30 30
ST05-103.14.040 14 16 40 40
ST05-103.16.040 16 18 40 40
ST05-103.16.050 16 18 50 50
ST05-103.16.060 16 18 60 60
ST05-103.16.080 16 18 80 80
ST05-103.18.040 18 20 40 40
ST05-103.18.050 18 20 50 50
ST05-103.18.060 18 20 60 60
ST05-103.18.080 18 20 80 80
ST05-103.20.040 20 22 40 40
ST05-103.20.060 20 22 60 60
ST05-103.20.080 20 22 80 80
ST05-101.12–20 / ST05-102.12–1
6/18 600 0.035 inch 2 Yes Yes
ST05-103.12–16
MICRO-TECH 7
TTS TRACHEAL
AND BRONCHIAL STENTS
PRECISE CONTROL DURING BRONCHOSCOPY
Our through-the-scope (TTS) tracheal and bronchial stents lengths are available. Each stent features a self-expanding
expand the MICRO-TECH range of self-expanding stents. Nitinol wire. Together with the uniquely braided stent
Unlike over-the-wire models, TTS stents allow easy and ends, this ensures maximum hold and minimizes the risk
safe stent placement when viewed directly through a of migration.
bronchoscope. Five different diameters and six different
SPECIFIC CHARACTERISTICS
8 MICRO-TECH
SUCCESSFUL APPLICATION IN PRACTICE
The stent is made from Nitinol wire, which is both highly flexible and re-
tains its shape. The tips at the stent ends have an angle of less than 90°,
which holds them in place inside the tissue and minimizes migration.
The extraction thread also allows the stent to be repositioned for ideal
placement in any situation.
FULLY COVERED
MICRO-TECH 9
FIVE DIAMETERS TO CHOOSE FROM
To ensure that the stent is ideally adapted to the patient‘s anatomy, it is available in five
different diameters, guaranteeing maximum hold as well as patient comfort.
ø 10 mm ø 12 mm ø 14 mm ø 16mm ø 18 mm
10 MICRO-TECH
SPECIFICATIONS
TTS STENTS
*1 XM: X-ray marking / *2 RA: rinsing attachment / *3 Lock: secures the insertion system during transport, storage and insertion
MICRO-TECH 11
CARINA-J-STENT
SUCCESSFUL RISK MANAGEMENT AFTER
PNEUMONECTOMY
MICRO-TECH introduces an additional special stent de- stent protects the surgical suture. At the same time, it
signed specifically for treatment of the respiratory tracts seals any existing suture insufficiencies and effectively
in the shape of the self expanding Carina-J-Stent. Due prevents suture stenoses. You can therefore reduce the
to its angled design in the form of a J, the stent can be risk of complications with the J-stent and accelerate the
perfectly placed in the trachea and main bronchus after patient’s healing process.
pneumonectomy has been performed. The fully covered
SPECIFIC CHARACTERISTICS
• Angled J-design
• Self-expanding
• Nitinol mesh with atraumatic ends
• Excellent positional stability
• High radial force
• Resistant and elastic covering
• Complete covering
• High radiopacity
• Guide wire-compatible up to 0.035 inches X-ray marking Covering
12 MICRO-TECH
SUCCESSFUL IN PRACTICAL USE
Released J-stent
SPECIFICATIONS
ST05-143.16.040 16 40 12 30 end-to-end
ST05-143.20.050 20 50 14 30 end-to-end
*1 RM – radiopaque markings / *2 IC – irrigation channel / *3 Lock – secures the introducer system during storage, transportation and introduction
MICRO-TECH 13
CARINA-Y-STENT
THE ORIGINAL
When it comes to bridging airway stenoses around the reliability and position stability. The newly developed in-
Carina, rely on the original Y stent: the Carina Y stent from sertion system also allows you to place the complex stent
MICRO-TECH. In 2006, MICRO-TECH was the first com- even more easily and precisely. With six different sizes,
pany worldwide to develop a self-expanding Y-Stent. the extended range offers you the ideal solution for every
and is now the only manufacturer able to offer you fully need. In addition to stents with a trachea diameter of 16
developed solutions and many years of experience. Thus and 20 mm, you also get stents with a diameter of 18 mm.
the innovative Y-design guarantees you a uniquely high
SPECIFIC CHARACTERISTICS
• Y-design
• Self-expanding
• Nitinol mesh with atraumatic ends
• Excellent positional stability
• High radial force
• Resistant and elastic covering
• High radiopacity
• Compatible for 2 guide wires of X-ray marking and covering Introducer system for easy
up to 0.035 inches positioning
14 MICRO-TECH
SUCCESSFUL IN PRACTICAL USE
SPECIFICATIONS
Length main bronchi mm
REF Ø trachea mm Length trachea mm Ø main bronchi mm right (no. covering) / left
CARINA-Y-STENT
ST05-152.16.040 16 40 12 20 (5) / 30
ST05-152.18.045 18 45 12 20 (5) / 30
ST05-152.20.050 20 50 14 20 (5) / 30
ST05-155.16.040 16 40 12 15 (5) / 30
ST05-155.18.045 18 45 12 15 (5) / 30
ST05-155.20.050 20 50 14 15 (5) / 30
*1 RM – radiopaque markings / *2 IC – irrigation channel / *3 Lock – secures the introducer system during storage, transportation and introduction
MICRO-TECH 15
Errors and technical modifications subject to change. Last updated: 15.12.2022