0% found this document useful (0 votes)
29 views3 pages

HVAC Inspection Checklists

The document provides a comprehensive set of HVAC inspection checklists designed to assist technicians in performing thorough inspections of various systems, including air conditioners, heat pumps, ductless mini splits, gas and electric furnaces, and tankless water heaters. Each checklist outlines specific inspection tasks to ensure proper functioning and identify necessary repairs. The checklists are compiled into a single PDF for convenience.

Uploaded by

fgpree2
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
29 views3 pages

HVAC Inspection Checklists

The document provides a comprehensive set of HVAC inspection checklists designed to assist technicians in performing thorough inspections of various systems, including air conditioners, heat pumps, ductless mini splits, gas and electric furnaces, and tankless water heaters. Each checklist outlines specific inspection tasks to ensure proper functioning and identify necessary repairs. The checklists are compiled into a single PDF for convenience.

Uploaded by

fgpree2
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

CHECKLISTS TO KEEP YOU ORGANIZED

HVAC Inspection Checklists


Using an HVAC inspection checklist helps you troubleshoot for your customers’ systems
consistently and thoroughly. We designed six different checklists to help you complete
thorough inspections—and they’re all rolled into one handy PDF.

1. Air conditioner inspection


Inspect the outdoor condensing unit
Inspect the condenser coil
Inspect the evaporator coil
Inspect the blower assembly
Check blower speed
Inspect lines for visible refrigerant leaks
Check the condensate drain pan for damage
Check air registers and ducts for cleanliness
Check for refrigerant leaks
Ensure that superheat and subcooling are correct
Inspect the drain line
Check for loose electrical connections
Verify that all equipment has the correct voltage
Inspect the suction and discharge pressure
Inspect belts for wear and tightness
Ensure the control panel works properly
Verify thermostat sensors are working properly
Take note of any necessary AC repair work

2. Heat pump inspection


Check the exterior for snow or ice buildup (winter/spring)
Check for dirt on outdoor coils
Ensure the pump is elevated from the ground and away from leaky gutters
Check for and repair air duct leakage
Take note of any necessary heat pump repair work

Jobber.com
3. Ductless mini split inspection

Outdoor unit
Check all wires and pipes on the outdoor condensing unit
Listen for excessive vibration on the condenser
Inspect the blower fan, motor, and electrical system
Check if the blower is running at the right speed

Indoor unit
Check all wires and pipes on the outdoor condensing unit
Listen for excessive vibration on the condenser
Inspect the blower fan, motor, and electrical system
Check if the blower is running at the right speed

4. Gas furnace inspection


Listen for excessive noise or vibration when furnace is running
Check that the blower fan is properly connected
Inspect the blower assembly for proper functioning
Check the air filter for dirt accumulation
Inspect the heat exchanger for corrosion, cracks, or damage in the ignitor, flame
sensor, and associated wiring
Listen for clicking in the spark ignitor (if installed)
Inspect wiring and control circuit
Check that wires are secured to the pressure switches
Check the cover panel for signs of water, corrosion, and blockage
Check that all furnace safety controls work properly
Inspect the gas piping and gas valve assembly
Check if vent connector pipes are securely fastened and supported
Check ductwork for damage and moisture accumulation
Verify correct voltage to furnace equipment
Verify supply and return air static pressures
Test and measure carbon monoxide around the furnace
Inspect thermostat operation and programming
Check inlet and outlet gas pressure
Cycle the furnace to check for proper operation
Take note of any necessary furnace repair work

Jobber.com | 2
5. Electric furnace inspection
Check that blower fan is clean, undamaged, and operating properly
Measure blower motor amp draw
Check air filters for dust and dirt
Check that all humidifier components are positioned properly
Check heat strips for corrosion, pitting, or burns
Measure heat strip amp draw
Verify the continuity of heat strips
Check that sequencers are operating properly
Check tightness of electrical wires and check for dead batteries
Inspect fuses
Inspect limit switches
Check ductwork for cracks, holes, and gas leaks
Test voltage across the thermostat’s terminals
Cycle the furnace to check for proper operation

6. Tankless water heater inspection checklist


Clean out sediment, dust, and oil from the water filter
Check for water leaks surrounding the system
Remove and clean dirt traps
Inspect and clean the burner
Inspect and clean the spark rod and flame sensor
Inspect and clean the combustion chamber
Check the hot water temperature
Check flame visibility and performance
Check if the relief valve is working properly
Flush the hot water system with white distilled vinegar