0% found this document useful (0 votes)
60 views8 pages

Guided-Wave-Radar-Level-Transmitter (1)

The document provides a detailed overview of various types of radar level transmitters, including guided wave radar and non-contact radar, along with their specifications and working principles. It outlines the measuring ranges, applications, and technical details such as accuracy, process temperature, and output signals for different models. Additionally, it includes ordering information and model selection guidelines based on specific tank/container characteristics and medium properties.

Uploaded by

sudhansu8behera
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
60 views8 pages

Guided-Wave-Radar-Level-Transmitter (1)

The document provides a detailed overview of various types of radar level transmitters, including guided wave radar and non-contact radar, along with their specifications and working principles. It outlines the measuring ranges, applications, and technical details such as accuracy, process temperature, and output signals for different models. Additionally, it includes ordering information and model selection guidelines based on specific tank/container characteristics and medium properties.

Uploaded by

sudhansu8behera
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 8

Bulletin No.

3300
Effective : Sept.. 2011
... the level & gas people
ISO-9001 : 2008 CERTIFIED COMPANY

RADAR LEVEL TRANSMITTER


GUIDED WAVE RADAR
NON CONTACT RADAR
HIGH FREQUENCY NON CONTACT RADAR
BRIEF INTRODUCTION OF GUIDED WAVE RADAR LEVEL TRANSMITTER

Product Description

Working principle
Guided wave radar transmitter works on the principle of time and travel (TDR). Radar wave
travels at the velocity of light. The flying time is converted into level signal via the electronic
components. The probe emits high frequency wave pulse which travels along a cable probe
or a rod probe. When the wave pulse reaches the medium surface, it will be reflected and
received by the receiver, and then the distance signal will be converted into level signals.

Input
The reflected wave pulse travels back along the
cable and arrives at the electronic unit. The
microprocessor will process the signals and
recognize the returned waves from medium
surface. The identification of correct return wave
signals can be done by the intelligent software. The
distance D from the medium surface is proportional to the
travel time: D=C X T/2 (C is velocity of light)
Due to the empty tank distance D is known, and then the level L is: L=E-D

Output
By setting of empty tank height E as zero point, the height of full tank F as full range point, and
other applicable parameter, the instrument will adapt into the working environment
automatically and correspond to output 4-20mA.

Measuring range F----measuring range


E----distance of empty tank
B----dead zone on the top
K----min. distance between probe and tank wall
Dead zone at top refers to the min. distance between the
highest medium position and the measuring reference
position (point).

Page No.2
Dead zone at bottom refers to the distance which cannot be measured accurately nearby the
bottom of the cable.
The distance between the dead zone at the top and the dead zone at the bottom is the effective
measuring distance.
Note:
Level measurement in a tank can be effectively performed only when the medium level within the
top dead zone and the bottom dead zone.

Introduction of Transmitter

Type : Rope
Application: liquid and solid powder.
Measuring range: 30m
Enclosure : Die Cast Aluminum
Process connection: thread, flange
Process temperature: -40°C~+250°C
Process pressure: -1~20Kg cm²
Accuracy: ±3mm
Repeatability: ±2mm
Frequency range: 100MHZ~1.8GHz
Signal output: 4-20mA/ HART (2-wire)
501E-32-A
Enclosure Protection : IP66

Type : Rod Probe


Application: liquid

Measuring range: 6m

Enclosure : Die Cast Aluminum

Process connection: thread, flange

Process temperature: -40°C~+250°C

Process pressure: -1~20Kg cm²

Accuracy: ±3mm
Repeatability: ±2mm
Frequency range: 100MHZ~1.8GHz

Signal output: 4-20mA/ HART (2-wire)

Enclosure Protection : IP66 501E-32-B


Page No.3
Type: Twin Cable
Application: solid powder.
Measuring range: 30m
Enclosure : Die Cast Aluminum
Process connection: thread, flange
Process temperature: -40°C~+250°C
Process pressure: -1~20Kg cm²
Accuracy: ±3mm
Repeatability: ±2mm
Frequency range: 100MHZ~1.8GHz
Signal output: 4-20mA/ HART (2-wire)
501E-32-C
Enclosure Protection : IP66

Type: Rod
Application: liquid
Measuring range: 6m
Enclosure : Die Cast Aluminum
Process connection: thread, flange
Process temperature: -40°C~+400°C
Process pressure: -1~40Kg cm²
Accuracy: ±3mm
Repeatability: ±2mm
Frequency range: 100MHZ~1.8GHz
501E-32-D
Signal output: 4-20mA/ HART (2-wire)
Enclosure Protection : IP66

Type: Rope/Rod
Application: corrosive liquids
Measuring range: 6m (for rod probe)/ 20m (for cable probe)
Enclosure : Die Cast Aluminum
Process connection: flange
Process temperature: -40°C~+120°C
Process pressure: -1~20Kg cm²
Accuracy: ±3mm
Repeatability: ±2mm
Frequency range: 100MHZ~1.8GHz
Signal output: 4-20mA/ HART (2-wire) 501E-32-E
Enclosure Protection : IP66
Page No.4
Type: Co-axial Rod
Application: liquids with lower dielectric constant or liquids with wave surface
Measuring range: 6m
Enclosure : Die Cast Aluminum
Process connection: thread, flange
Process temperature: -40°C~+250°C
Process pressure: -1~20Kg cm²
Accuracy: ±3mm
Repeatability: ±2mm
Frequency range: 100MHZ~1.8GHz
Signal output: 4-20mA/ HART (2-wire)
501E-32-F
Enclosure Protection Grade : IP66

General Specifications
— Working frequency : 100MHz~1.8GHz

—Application : Liquid, Solid Powder, Corrosive Liquid, Liquid with low die electric

— Power Supply : 24V DC (Power Range 12V~45V)

— Output Signal : 4~20mA Output Superimposed with HART® Protocol/ Field bus

— System : 2 Wire

— Load Resistance : 600 ohm HART®/ 575 ohm FF

— Fail safe/ Loop check : Provided 3.8mA or 21.6mA

— Relative Humidity : 0~100%

— Damping : Adjustable between 0~32 sec

— Response Time : >0.2 sec.

— Warm up Time : 3 sec.

— Sample : echo sampling 55 times /s

— Display : 4.5 Digit LCD

— Repeatability : ± 2mm up to 6 Mt.


± 6mm beyond 6 Mt.

l Sensing Material : PP / PTFE, SS316

l Insulation : PTFE or Ceramic

l Electrical Connection : ½” , ¾” NPT (F)

l Enclosure : Die cast Aluminum or Stainless Steel Page No.5


Relationship Between Different Mediums And The Measuring Range.
Medium
DK(ε) Solid particles Liquid Measuring range
group
cold concentrate, 3m (only for coaxial
1 1.4~1.6
e.g. N2CO2 probe)
Liquefied gas, e.g.
White lime Propane
2 1.6~1.9 Specials Cement Solvent 20m
Sugar Freon12/Freon
Palm oil
Normal cement,
3 1.9~2.5 Mineral oil, fuel 20m
Plaster
Benzene, styrene,
Grain, seeds
Toluene
4 2.5~4 Stone 25m
Furan
Sand
Naphthalene
Chlorobenzene,
Chloroform
Moist stone, mineral
5 4~7 Cellulose spray 30m
Salt
Isocyan hydrochloric
Acid. Aniline
Metal powder Liquid with water
6 >7 Carbon black Alcohol 30m
Coal Liquid ammonia

Model Selection Reference Table For Guided Wave Radar Level Transmitter
Antenna Dielectic Solid Solid
Model Application Liquid Accuracy Beam angle
diameter constant particles powder

Liquid 4mm 2.5~3.0 N.A N.A 20m 3mm N.A


501E-32-A
Solid 6mm 2.5~3.0 N.A 20m N.A 3mm N.A

501E-32-B Liquid 10mm 2.5~3.0 N.A N.A 6m 3mm N.A

501E-32-C Solid/Liquid Both 6mm 2.5~3.0 N.A 20mm 25m 3mm N.A

501E-32-D Liquid 10mm 2.5~3.0 N.A N.A 6m 3mm N.A


7mm
Liquid 2.5~3.0 N.A N.A 20m 3mm N.A
(Probe Cable)
501E-32-E
14mm
Liquid 2.5~3.0 N.A N.A 6m 3mm N.A
(Probe Rod)

501E-32-F Liquid 25mm 2.5~3.0 N.A N.A 6m 3mm N.A


Ordering Information

I II III IV V VI VII VIII IX X XI

Please Specify
Model Selection
501E-32-A / B / C / D / E / F..........
Electrical Classification
Weather proof............................................ W
Explosion proof.......................................... E
Intrinsically Safe......................................... I
Measuring Range
6 Mtr. ......................................................
Please Specify
10 Mtr......................................................
20 Mtr......................................................
30 Mtr......................................................
Output
4-20mA linear Output........................................ H
Fieldbus Output................................................. F

Process Connection
501E-32-A 501E-32-C
& & 501E-32-E 501E-32-F
501E-32-B 501E-32-D
A1 - 1½”NPT B1 - 3” Flange C1 -1½”NPT D1 - 2” Flange
A2 - 2” Flange B2 - 4” Flange C2 -2” Flange D2 - 3” Flange
Please Specify

A3 - 3” Flange B3 - 6” Flange C3 -3” Flange D3 - 4” Flange


A4 - 4” Flange B4 - 8” Flange C4 -4” Flange D4 - 6” Flange
A5 - 6” Flange C5 -6” Flange D5 - 8” Flange
A6 - 8” Flange
Others.....................................................................................J .........
Head Flange Material
CS.......................................................................................................................... 1
PP........................................................................................................................... 2
SS304.................................................................................................................... 3
SS316.................................................................................................................... 4
Temperature
Please Specify

Common seal/ (-40~+120)ºC............................................................................................... P


Seal for high temperature/ (40~+250)ºC with cooling fins................................................... G
Pressure (kg/cm²)...........................................................................................
Mounting
Top Internal........................................................................................................................................... T
External Cage ...................................................................................................................................... S

External Chamber (Optional)


CS........................................................................................................................................................................ A
SS304................................................................................................................................................................. B
SS316................................................................................................................................................................. C
N/A...................................................................................................................................................................... D
Chamber Process Connection
1
SW..................................................................................................................................................................................
Flange............................................................................................................................................................................
2
N/A................................................................................................................................................................................. 3
Data sheet for model selection
Tank/container information
Tank type:

□ Storage tank □ Reaction tank □ Separation tank □ Marine tank


Tank structure:
□ Tank material: □ Tank pressure:
Tank size:
Height of tank: m
Diameter of tank: m
Shape of tank top:
□ Arch □ Flat top □ Open □ Conic
Shape of tank bottom:
□ Tapered □ Flat □ Inclined □ Arch
Installation:
□ Top mounted □ Side mounted □ Bypass pipe mounted □ Wave guide pipe
mounted
Extension pipe at tank top (important information):
Pipe height: mm,
Pipe diameter: mm
Measuring medium
Medium name: □ Liquid □ solid □ mix medium
Medium temperature: ℃
Dielectric constant:
Adhesion: □ Yes □ No
Stirring: □ Yes □ No
Process connection
Thread: (□ G1½〞□ 1½〞NPT □ G2”A □ G1〞A □ 1〞NPT) □ Flange (ANSI= )
Power supply:
□ 24V DC 2-wire □ 220V AC
Output: □ 4-20mA □ HART □ Fieldbus
Display: □ With display and programmer □ Without display and programmer

V. AUTOMAT & INSTRUMENTS (P) LTD.


Regd. Off.:- AUTOMAT HOUSE:- F-61, Okhla Industrial Area, Works:- AUTOMAT HOUSE:- F-34, Okhla Industrial Area,
Phase-I, New Delhi-110020 (INDIA) Phase-I, New Delhi-110020 (INDIA)
Ph.: 91-11- 47627200 , Fax : 91-11-26819440 Ph.: 91-011- 46353500 , Fax : 91-011-26819440
Email : [email protected], [email protected], Email : [email protected], [email protected]
website : www.vautomat.com website : www.vautomat.com
BRANCHES IN BARODA, MUMBAI, KOLKATA, JAMSHEDPUR, SECUNDERABAD & CHENNAI