0% found this document useful (0 votes)
33 views

NovaLCT-LED-Configuration-Tool-for-Synchronous-Control-System-User-Manual-V5.7.0

The NovaLCT User Manual provides comprehensive guidance on using the LED Configuration Tool for Synchronous Control Systems, covering software installation, device connection, user login, and screen configuration. It details various functions such as screen monitoring, management, maintenance, and troubleshooting, ensuring optimal performance of LED displays. The manual is designed for a wide range of users, including manufacturers, contractors, and technical support engineers, facilitating efficient configuration and management of LED screens.

Uploaded by

svagant112
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
33 views

NovaLCT-LED-Configuration-Tool-for-Synchronous-Control-System-User-Manual-V5.7.0

The NovaLCT User Manual provides comprehensive guidance on using the LED Configuration Tool for Synchronous Control Systems, covering software installation, device connection, user login, and screen configuration. It details various functions such as screen monitoring, management, maintenance, and troubleshooting, ensuring optimal performance of LED displays. The manual is designed for a wide range of users, including manufacturers, contractors, and technical support engineers, facilitating efficient configuration and management of LED screens.

Uploaded by

svagant112
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 146

NovaLCT

LED Configuration Tool for Synchronous Control System

User Manual
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

Contents
Contents .......................................................................................................................................................................................... i
1 Software Introduction ................................................................................................................................................................... 1
2 Software Installation .................................................................................................................................................................... 2
3 Device Connection ....................................................................................................................................................................... 3
3.1 Connect PC to Sending Card ................................................................................................................................................ 3
3.2 Connect NovaLCT to Sending Card ...................................................................................................................................... 3
4 User Login ................................................................................................................................................................................... 5
5 Screen Configuration ................................................................................................................................................................... 6
5.1 Load Configuration Files........................................................................................................................................................ 6
5.2 Configure a Screen Manually ................................................................................................................................................ 7
5.2.1 Step 1 Set Input Source............................................................................................................................................... 8
5.2.2 Step 2 Light a Screen ................................................................................................................................................ 10
5.2.3 Step 3 Connect Screen.............................................................................................................................................. 22
5.2.4 Step 4 (Optional) Save Configuration Files ................................................................................................................ 27
5.3 Set Redundancy .................................................................................................................................................................. 29
5.4 Enable 3D............................................................................................................................................................................ 32
5.5 Set Working Mode ............................................................................................................................................................... 34
5.6 Enable Zoom ....................................................................................................................................................................... 36
5.7 Set Audio Input .................................................................................................................................................................... 37
5.8 Set Performance Parameters .............................................................................................................................................. 38
5.9 Set Module Flash Parameters ............................................................................................................................................. 45
6 Brightness and Chroma Adjustment .......................................................................................................................................... 47
6.1 Calibration ........................................................................................................................................................................... 47
6.1.1 Set Online Calibration Parameters ............................................................................................................................ 47
6.1.2 Get Average Coefficients ........................................................................................................................................... 48
6.1.3 Manage Calibration Coefficients ................................................................................................................................ 49
6.1.4 Manage Double Calibration Coefficients .................................................................................................................... 53
6.1.5 Set Thermal Compensation ....................................................................................................................................... 54
6.2 Adjust Brightness ................................................................................................................................................................. 55
6.2.1 Adjust Brightness Manually ........................................................................................................................................ 55
6.2.2 Adjust Brightness Automatically ................................................................................................................................. 60
6.3 Adjust Multi-batch Cabinets ................................................................................................................................................. 63
6.4 Adjust Dark or Bright Lines .................................................................................................................................................. 68
6.5 Correct Brighter Pixels......................................................................................................................................................... 70
6.6 Set Advanced Color ............................................................................................................................................................. 71
6.7 Adjust Screen Effect ............................................................................................................................................................ 75
6.8 Set Image Booster Engine................................................................................................................................................... 77
6.9 Batch Check Calibration Effects .......................................................................................................................................... 81
7 Screen Monitoring ...................................................................................................................................................................... 83
7.1 Register Screens with VNNOX Care ................................................................................................................................... 83
7.1.1 Register Online Screens ............................................................................................................................................ 83
7.1.2 Register Offline Screens ............................................................................................................................................ 86
7.2 View and Configure Monitoring ........................................................................................................................................... 91
7.3 Configure Module Monitoring .............................................................................................................................................. 95
8 Screen Management ................................................................................................................................................................. 98
8.1 Multi-function Card Management ........................................................................................................................................ 98
8.2 Multiple-screen Management ............................................................................................................................................ 103
8.3 Prestore Screen ................................................................................................................................................................ 105
8.4 Receiving Card Relay ........................................................................................................................................................ 106
8.5 Screen Control .................................................................................................................................................................. 108
8.6 Controller Cabinet Configuration File Import ..................................................................................................................... 109
www.novastar.tech i
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

8.7 Module ID Settings ............................................................................................................................................................ 110


8.8 Set Device Communication Parameters ............................................................................................................................ 113
8.9 Sending Card Relay Settings ............................................................................................................................................ 114
8.10 Optical Port Settings ........................................................................................................................................................ 114
9 Screen Maintenance ................................................................................................................................................................ 116
9.1 Firmware Program Update ................................................................................................................................................ 116
9.2 LED Error Detection .......................................................................................................................................................... 118
9.3 Reset Run Time ................................................................................................................................................................. 120
9.4 Bit Error Detection ............................................................................................................................................................. 121
9.5 View Hardware Information ............................................................................................................................................... 122
9.6 Set Cabinet Dehumidification ............................................................................................................................................ 124
10 Plug-in.................................................................................................................................................................................... 127
10.1 Test Tool .......................................................................................................................................................................... 127
10.2 Calculator ........................................................................................................................................................................ 127
10.3 External Program............................................................................................................................................................. 128
11 Software Settings ................................................................................................................................................................... 129
11.1 Configuration Information Management ........................................................................................................................... 129
11.2 Set Main Window Starting Position .................................................................................................................................. 129
11.3 Configure the Save Function ........................................................................................................................................... 130
11.4 Cloud Server Configuration ............................................................................................................................................. 131
11.5 Test Tool Settings ............................................................................................................................................................. 131
11.6 Change UI Language....................................................................................................................................................... 132
11.7 Obtain Help Information ................................................................................................................................................... 132
11.8 Update Software .............................................................................................................................................................. 133
11.9 Export Log ....................................................................................................................................................................... 134
12 Troubleshooting ..................................................................................................................................................................... 135
12.1 Installation Problems ....................................................................................................................................................... 135
12.1.1 Failed to install NovaLCT of earlier versions.......................................................................................................... 135
12.1.2 .NET Framework is missing ................................................................................................................................... 135
12.1.3 "DeleteFile failed" error .......................................................................................................................................... 135
12.1.4 Prompts to run DPinst.exe ..................................................................................................................................... 136
12.2 Other Problems ............................................................................................................................................................... 137
12.2.1 "No Screen" displayed in NovaLCT ....................................................................................................................... 137
12.2.2 Permission error .................................................................................................................................................... 137
12.2.3 Failed to connect colorimeter ................................................................................................................................. 140
12.2.4 No available server for VNNOX Care .................................................................................................................... 141
13 FAQs ...................................................................................................................................................................................... 142
13.1 How do I set the proxy when NovaLCT needs to access WAN network? ........................................................................ 142

www.novastar.tech ii
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

1 Software Introduction
The LED display control systems are categorized into synchronous control system and asynchronous control system.
In synchronous control system, the images are played and controlled on the screen synchronously with the video
source (such as on PC or camera). In asynchronous control system, they are played and controlled asynchronously.
The program is pre-stored on the local playback device and then played according to the playback schedule.
No matter in which control system, the application scenario requires a piece of supporting software to configure the
control system. Based on the needs of different users, NovaStar has designed and developed an LED screen
configuration tool — NovaLCT.
As a basic screen configuration tool running on Windows, NovaLCT has the following features.
Easy to install
The latest installation package can be downloaded from NovaStar official website www.novastar.tech at any
time and it is quick and easy to install.
Practical functions
A lot of commonly used functions are provided, such as screen configuration, screen monitoring, redundancy
settings, brightness adjustment, multi-batch adjustment, dark or bright line adjustment, multifunction card
management and other configuration functions. Thanks to these functions, the screen can present optimal
display effect and is easy to manage and maintain.
Wide scope of applications
NovaLCT can be used to configure NovaStar synchronous control system products and multimedia players of
asynchronous control system. It meets different needs of screen manufacturers, contractors, distributors, rental
application clients, end users and technical support engineers.
Efficient configuration
After the PC and control system product are connected, users can perform any operations with the PC.
NovaLCT displays the corresponding functions and parameters according to the different hardware models and
programs. During configuration, various kinds of configuration files can be used to complete operations quickly.
If the configuration information is saved to the hardware, it will not be lost even after the hardware is powered off.

www.novastar.tech 1
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

2 Software Installation
Obtaining Software
Visit www.novastar.tech and choose DOWNLOADS > Software. In the NovaLCT area, download the needed version
of software installation package.

Figure 2-1 Obtaining software

Installing Software
Before installing NovaLCT, prepare a Windows PC and disable the antivirus software.
Unzip the installation package, run the .exe file and follow the setup wizard to complete the installation. If a firewall
prompt appears, choose to allow the installation.
If the PC does not have the serial port driver program or the program version is earlier, the NovaLCT installation
program will automatically install or update the program.

Verifying Installation

If the installation is successful, the shortcut appears on the desktop, and and icons appear on the
taskbar.

www.novastar.tech 2
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

3 Device Connection
3.1 Connect PC to Sending Card
Connect the PC with NovaLCT installed to the sending card with control cable (USB cable or Ethernet cable), as
shown in Figure 3-1. The MCTRL4K is used as an example of sending device.
All control commands, parameters and configuration files are transmitted with the control cable.
The PC can also be connected to multiple sending cards with control cable. After selecting a target communication
port in NovaLCT, you can operate the connected device.

Figure 3-1 Hardware connection example

3.2 Connect NovaLCT to Sending Card


If the hardware connection is normal and the sending card is operating normally, NovaLCT connects to the sending
card automatically. After successful connection, the NovaLCT main window displays the sending card quantity and
monitoring information about the control system, as shown in Figure 3-2.

Figure 3-2 Main window (Not logged in)

Click View Details of Device to view the communication port, device name, device quantity, SN, and take over the
control of other devices. If the communication port information contains IP address, NovaLCT communicates with the
device via Ethernet port. If it contains “USB” characters, they communicate via USB port. “SN” is the unique identifier
of the sending card.

Notes
Currently, the take over function is only available for MGT2000, MGT1000, MGT600. When a device is being
controlled by another instance of NovaLCT and is not available for connection by your NovaLCT, you can click
Take Over under Operation to assume control of the device.

Connection related operations:


Reconnect sending card
Choose System > Reconnect.
Restart server

On the taskbar, right click and click Restart.


www.novastar.tech 3
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

Set connection parameters

On the taskbar, right click , click Detect Config and set the marked parameters in the figure below.
- Auto detect controller: When this is checked, the software automatically detects the connected devices at
the specified intervals (Detect interval).
- Disable cascade communication: In a setup with devices connected in cascade, checking this option allows
the software to connect only to the first device and skip detection for other devices in the cascade,
improving connection efficiency. If unchecked, the software will perform connection detection for all devices.

www.novastar.tech 4
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

4 User Login
Sending Card Connected
If the sending card is connected, users can directly use the available functions without login. To use the advanced
functions, users must log in to NovaLCT.
Operations:
Choose User > Advanced Synchronous System User Login. Enter the password and click Login. The default
password is “admin”.
After successful login, the main window is shown as Figure 4-1.

Figure 4-1 Main window (Logged in)

Other Operations:
 To log out, choose User > Logout.

 To change the login password, choose User > Change Password.

Sending Card Not Connected


If the sending card is not connected and users want to learn about the functions, use the demonstration mode.
How to access demonstration mode:
Choose User > Demonstration Login. Enter the password “admin” and click Login.
Other operation:
Click View Details of Device, then in the pop-up window, click Change Device Type to switch the device in
demonstration mode.

www.novastar.tech 5
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

5 Screen Configuration
Notes
NovaLCT currently only supports configuring regular screens. Irregular screens are not supported.

5.1 Load Configuration Files


Applications
Load a cloud or local configuration file to finish screen configuration quickly.

Applicable Products
All receiving cards and sending cards

Prerequisites
 Load a cloud configuration file: The control computer is connected to the Internet.

 Load a local configuration file: The system configuration file (.scfg and .zip) is prepared.

Related Information
 The information in the cloud configuration file and local .zip file can be viewed in NovaLCT, but cannot be modified
before the information is sent to the hardware.
 The information in the local .scfg file can be viewed and modified in NovaLCT before the information is sent to the
hardware.

Operating Procedure
Step 1 On the menu bar, choose User > Advanced Synchronous System User Login. Enter the password and click
Login.

The default password is “admin”.

Step 2 Click or choose Settings > Screen Configuration from the menu bar to open the dialog box shown in
Figure 5-1.

Figure 5-1 Screen configuration method

Step 3 Choose a communication port.

If the PC is connected to multiple sending cards with control cable, there are multiple ports in the drop-down list.

Step 4 Perform any of the following operations as needed to load a configuration file.

Load from cloud platform

www.novastar.tech 6
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

a. Select Cloud Restore and select a node from the drop-down list.
b. Click Next to open the Restore Configuration File dialog box.

c. Select a tab as needed and send the configuration file to the hardware.
Sending Card: Click Send to HW to send the Ethernet port redundancy configuration file of the sending
card to the hardware.
Receiving Card: Select Send By Topology or Send By Physical Address, set the related parameters,
and click Send to Specified RV Cards to send the receiving card configuration file to the hardware.
When you have selected Select by Topology or List, if it is not convenient to select an area with the
software, you can select Select Operating Area on Screen to select the area on the display window.
Screen Connection: Click Send to HW to send the screen connection file to the hardware.
d. In the displayed dialog box, click Save to HW or Don’t Save to HW.
Load from local PC
a. Select Local Restore.
b. Click Browse, select a configuration file, and click Open.
c. Click Next.
For the .zip local configuration file, see the figures and steps in the Load from cloud platform section.
For the .scfg local configuration file, the loading progress will be displayed. After the file is loaded, the
dialog box shown below is closed automatically.

5.2 Configure a Screen Manually


For a common screen, set the input source, light the screen and connect the screen in order to complete the screen
configuration.

Notes
The screen configuration page in NovaLCT varies depending on the functions supported by the sending card
and receiving card.

www.novastar.tech 7
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

5.2.1 Step 1 Set Input Source

Applications
Set the input source type, resolution, refresh rate and bit depth for the sending card to make the screen display the
specified input source pixel to pixel.

Applicable Products
The V1160 and VX16s all-in-one devices, and other sending cards

Prerequisites
None

Related Information
If the resolutions of the sending card and screen are the same, the image can be displayed pixel to pixel.
If the refresh rate is too low, the screen flickers. A higher refresh rate helps stabilize the display image.

Operating Procedure
Step 1 On the menu bar, choose User > Advanced Synchronous System User Login. Enter the password and click
Login.

The default password is “admin”.

Step 2 Click or choose Settings > Screen Configuration from the menu bar.

Step 3 On the pop-up dialog box, select a communication port and choose Configure Screen. Then, click Next.

Figure 5-2 Screen configuration method

Step 4 On the Sending Card tab page, view the current display mode, as shown in Figure 5-3.

Figure 5-3 Input source information

www.novastar.tech 8
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

Step 5 Select Automatic Selection to allow NovaLCT to automatically select the input source according to the input signal,
or select an input source from the drop-down list.

Step 6 Click Send to send the configuration information to the hardware.

Step 7 In the Source Configuration area, set the input source type and the corresponding resolution. You can select a
resolution from the drop-down list or customize a resolution.

Step 8 Set the refresh rate and bit depth of input source.

After you change the refresh rate, you are advised to resend the performance parameters on the Receiving Card tab
page to avoid the problem that the receiving card cannot automatically fit the refresh rate.
The recommended input source bit depth is 8 bit.

Step 9 For the MCTRL660 PRO and MCTRL R5, you can perform the following operations to set input source backup if
necessary. Otherwise, skip this step.

1. Click Set next to Source Backup Setting.


2. Select Start source backup.
3. Set the input source backup relation and click OK.

Figure 5-4 Source backup settings

Step 10 Click Set to send the configuration information to the hardware.

Step 11 Click Refresh to confirm the result of input source setting.

Step 12 Click Save to save the configuration information to the hardware.

Step 13 After successful saving, choose whether to save the backup file to the local computer.

When the control computer can access the Internet, you can use the backup file to register screens to VNNOX Care.
For details, see 7.1.2.1 Register by Using Local Backup Files (Recommended).

This step is related with the configuration of the save function. See 11.2 Set Main Window Starting Position

Applications
Set the coordinates of the top-left corner of the main window of NovaLCT on the desktop, and make the window
display in the specified position when the software is started.

Applicable Products
N/A

Prerequisites
None

Related Information
None

www.novastar.tech 9
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

Operating Procedure
Step 1 On the menu bar, choose Settings > The Main Window Starting Position.

Figure 5-5 Setting starting position coordinates

Step 2 Set the coordinates of the top-left corner of the main window on the desktop, and click OK.

After the settings are done, the main window moves to the specified position. When next time NovaLCT is started, the
main window will be displayed in the target position.

Configure the Save Function.

Notes
You can click Restore Factory Settings on the Sending Card tab page to reset the sending card
configuration information to factory settings.

5.2.2 Step 2 Light a Screen

Notes
When using the A10s Pro receiving card, please refer to 5.2.2.2 Configuration through NCP.

www.novastar.tech 10
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

5.2.2.1 Configuration through RCFG

Note
In the Receiving Card tab of Screen Configuration, you can click Load from Cloud (VNNOX Care) or Load
from PC to load a receiving card configuration file (.rcfgx/.rcfg) and quickly up light up the screen. This section
outlines the steps needed for manual configuration.
When loading from the cloud, if the firmware version of the receiving card does not match the configuration file,
you may choose whether to upgrade the firmware.

5.2.2.1.1 Light Module

Applications
Set the receiving card parameters to light a new module.

Applicable Products
For receiving cards that support .rcfgx or .rcfg files

Prerequisites
 The receiving card firmware supports the module chip.

 The display settings on the PC are completed. For example, display settings on Windows 10 are shown in Figure
5-6 and Figure 5-7. The resolution of PC graphics card must be set to be greater than or equal to the screen
resolution based on the actual condition.

Figure 5-6 PC display settings 1

www.novastar.tech 11
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

Figure 5-7 PC display settings 2

Related Information
The module specifications are provided when the module is shipped. Users can also obtain the specifications from
the driver chip, decoding chip and pin definition on the module.
For example, the following information can be obtained from the module shown in Figure 5-8.
 Driver chip: 24 SUM2016GAS2 chips

 Data type: 2 groups of parallel RGB data

 Module type: Regular module

 Pixel quantity: 64 columns × 32 rows

 Decoding chip: 2 SUM74HC138 chips

Figure 5-8 Module example

Both regular and irregular modules are rectangular. If the module column quantity can be divided by 16 without
remainder, the module is a regular one.
An irregular module has any of the following features:
 Some output pins of the driver chip are not used.

www.novastar.tech 12
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

 The numbers of pixel rows or columns driven by each data group are different.

 The data groups do not drive the pixel rows or columns in order.

Operating Procedure
Step 1 On the Screen Configuration page, click the Receiving Card tab.

Figure 5-9 Screen configuration

Step 2 Click Smart Settings.

Step 3 Select option 1 and click Next.


 Option 1: Enter smart settings.

 Option 2: Load a module configuration file to quickly configure the module.

 Option 3: Load the module configuration file in the cabinet database to quickly configure the module.

After the configuration file is loaded, click Send to Receiving Card.

www.novastar.tech 13
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

Figure 5-10 Smart settings options

Step 4 On the Smart Settings Guide 1 page, set the parameters and click Next.

Figure 5-11 Smart Settings Guide 1

 Module Chip: Select the type of module driver chip. You can click Select chip type to open the chip table and
select the desired chip. If the table does not have the type of chip you want, select Common Chip.
 Data Type: Select the data type of the module. Parallel data indicates that the data of the RGB three colors is
transmitted parallelly, but serial data indicates that the data of the RGB three colors is transmitted serially.
 Module Type: Select the module type. Module type includes regular and irregular modules.

 Number of Driver Chips for One Scan and One Color: This parameter is available when irregular module is
selected. It is calculated by the following formula.
Number of driver chips for one scan and one color = Number of driver chips / Number of data groups / Number
of colors
 Quantity of Pixels: Set the quantity of pixel columns and rows on the module.

 Row Decoding Type: Select the row decoding type of the module. You can click Select a decoding type to open
the decoding type table and select the desired type. When the Parity Scan option is displayed, if only the odd or
even output of the decoding chip is used, please select this option.
 Hub Mode: Use the default value.

 Ghost Control Signal Polarity: Use the default value.


www.novastar.tech 14
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

Step 5 On the Smart Settings Guide 2 page, select one option based on the current display on the module and click Next.

When you are viewing the display on the module, view the first module loaded by the first receiving card connected to
the first Ethernet port.

Figure 5-12 Smart Settings Guide 2

Step 6 On the Smart Settings Guide 3 page, select the module display color switching mode and check whether the current
module display color is the same as the selected color.

Figure 5-13 Smart Settings Guide 3

 If they are the same, click Next to go to Step 7.

 If they are different, select a color corresponding to the module display color from the drop-down list to make them
the same.

Step 7 On the Smart Settings Guide 4 page, set the parameters based on the number of lighted rows (or columns) on the
module and click Next.

Figure 5-14 Smart Settings Guide 4

Step 8 On the Smart Settings Guide 5 page, set the parameters based on the number of lighted rows (or columns) on the
module and click Next.

www.novastar.tech 15
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

Figure 5-15 Smart Settings Guide 5

Step 9 On the Smart Settings Guide 6 page, view the flashing pixel in the first row on the module and click the
corresponding cell in the grid to draw the pixel position.

Generally, you only need to draw pixel position for the first row of pixels. If the flashing pixels are on the other row or
column, click the corresponding cells in the grid.
 Automatic Generation: Complete pixel position drawing for the first row of pixels quickly.

 Cancel: Clear the last pixel position drawing.

 Clear: Clear all the pixel position drawing.

 Lighted Pixels: Display the total number of lighted pixels on the current module.
 Unlighted Pixels: For regular modules, the value of this parameter is always 0. For irregular modules, a No
corresponding LED button is added to the page shown in Figure 5-16. When a pixel cannot be lighted during
pixel position drawing, you can click No corresponding LED and the number of Unlighted Pixels increases by 1.

 : Zoom out the grid.

 : Zoom in the grid.

Figure 5-16 Smart Settings Guide 6

Step 10 View the flashing pixel in the first column on the module and click the corresponding cell in the grid to draw the pixel
position (You can also use the keyboard arrow key to quickly draw the position), and click OK after the drawing is
done.

Generally, you only need to draw pixel position for the first column of pixels. If the flashing pixels are on the other row
or column, click the corresponding cells in the grid.

Step 11 Click Next and click OK.

Step 12 (Optional) Enter a module name and save the module configuration as a file or save the module configuration to the
cabinet database.

www.novastar.tech 16
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

In the future, you can load the module configuration file to quickly light the modules with the same specifications.
 Browse: Select the path to save the module configuration file.

 Change Cabinet Database: Open or create a cabinet database.

 View: View the module configuration file saved in the cabinet database.

 View Module: View the detailed information about the current module.

Figure 5-17 Saving module information

Step 13 Click Complete.

Notes
On the Receiving Card tab page, you can also perform the following operations.

 In the Module Information area, click to view the detailed module information. On the Details of
Module page, click Save Module to save the module configuration as a file.
 Click Restore Factory settings to reset the configuration information of all or specified receiving cards to
factory settings.
 Type “admin” to show the Save to factory area button. This button is used to save some parameters to
the factory area before delivering the cabinets to users. This function is supported only by some receiving
cards.

5.2.2.1.2 Set Cabinet

Applications
Set the size of the cabinet loaded by the current receiving card and the cascading direction of the modules in the
cabinet.

Applicable Products
For receiving cards that support .rcfgx or .rcfg files

Prerequisites
 A module is lighted. For details, see 5.2.2.1.1 Light Module.

 If the cabinet is irregular, the cabinet database file (.mcl) or module configuration file (.module) is prepared.

Related Information
If a cabinet is rectangle and the specifications of all the modules are the same, the cabinet is a regular cabinet,
otherwise it is an irregular cabinet. For an irregular cabinet, the configuration file must be used to construct the
cabinet.

Operating Procedure
Step 1 On the Screen Configuration page, click the Receiving Card tab.

Step 2 In the Cabinet Information area, perform the corresponding operations below based on the cabinet type.

www.novastar.tech 17
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

Figure 5-18 Cabinet information

Configure regular cabinet


Select Regular, set the cabinet width and height, and set the cascading direction of modules.
Configure irregular cabinet
a. If you need to configure row extraction position, select Big Control Mode. If Big Control Mode is not
displayed or you do not need to configure row extraction position, skip this step.
b. Select Irregular, click Construct Cabinet to open the dialog box shown in Figure 5-19.
c. If you have a cabinet configuration file (.mcl/.cabinet), click Load to configure the cabinet quickly. If you do
not have the file, preform the subsequent operations to manually configure the cabinet.
d. Set Data Groups of Cabinet according to the number of data groups actually used by the cabinet and
click Set.
e. Click From Cabinet Database or From File to load modules.
When loading modules from files, you can set the numbers of module rows and columns. The loaded
modules support the Ctrl+C, Ctrl+V, Ctrl+A, Delete, Ctrl+Z and Ctrl+Y keyboard shortcuts.
f. Adjust the positions of modules to let them form a cabinet whose size is consistent with the actual cabinet
size.
You can adjust the module positions by directly dragging the modules or using the functional buttons in the
Module Alignment and Module Spacing areas. Currently, the position adjustment operations cannot be
undone. You can also adjust the display scale of the module to zoom in, zoom out, or fit automatically as
needed in the Zoom section.
g. Select the data group one by one and double click the corresponding modules to connect them.
To display the test pattern by data groups, check the option Enable Data Group Display.
When selecting the data group, you can click the A key or D key on the keyboard to switch data groups.
After you double click the module, the module number is displayed. For example, (2, 2) indicates the
module is the second module of the second data group. Right clicking the module can cancel the
connection.
Functions in the Quick Operation area allow you to quickly number the selected modules and you do not
need to select data group first. The module positions after numbering may change and you can adjust
them if necessary.
h. Select Simple Mode or Advanced and configure one or more row extraction positions. If Big Control
Mode is not selected on the Receiving Card tab page, skip this step.
Simple Mode: Set the row extraction position of cabinet and click Add. For example, if you set the
parameter to 2, the second row in the cabinet will be extracted during row extraction and the second
column will be extracted during column extraction.
Advanced: Set the row extraction position of module and click Add. For example, if you set the three
parameters to 2, the second row in the second cascaded module connected to the second data group will
be extracted during row extraction and the second column in the second cascaded module connected to
the second data group will be extracted during column extraction.
i. After the configurations are done, click OK. If necessary, click Save to save the cabinet configuration
information to the cabinet database or save the information as a file.
j. (Optional) Click View Cabinet to view the cabinet information.

www.novastar.tech 18
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

Figure 5-19 Constructing irregular cabinet

Step 3 If cabinet rotation is required, click Set Rotation and select the rotation angle. If it is not required, skip this step.

After cabinet rotation is set, all the input sources will be rotated to display according to the set angle.

Figure 5-20 Set cabinet rotation

Step 4 After the settings are done, click Send to Receiving Card. In the displayed dialog box, select All Receiving Card or
specify receiving cards, and click Send.
 All Receiving Card: Send the receiving card configuration information to all the receiving cards loaded by the
current sending card. If you select Reset the Starting Coordinate of Receiving Card, the starting coordinates of
all the receiving cards will be reset to (0, 0). As a result, all the receiving cards display the top-left image of the
input source.
 Specify Receiving Card: Send the receiving card configuration information to the specified receiving cards by
topology or by physical address.

Figure 5-21 Sending parameters to receiving card

Step 5 After successful sending, click OK to close the prompt box. The screen is now lighted.

Step 6 (Optional) Click Save to File to save the configuration information as a receiving card configuration file (.rcfgx).

www.novastar.tech 19
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

5.2.2.2 Configuration through NCP

Applications
Configure the cabinet by loading NCP files. Additionally, you can read the cabinet information, restore the NCP, and
set the cabinet rotation and indicator status.

Applicable Products
For receiving cards that support NCP files

Prerequisites
 To load NCP files, ensure you have prepared the .ncp file and that its applicable model matches the current
receiving card in use.
 To restore NCP files, confirm that the receiving card model is A8s Pro and that the firmware version is V1.2.0.0 or
higher.

Related Information
None

Operating Procedure
Step 1 On the Screen Configuration page, click the Receiving Card tab for NCP Management.

Notes
If the Receiving Card tab defaults to the .rcfgx/.rcfg configuration interface, click NCP Management to enter
the NCP management interface.

Figure 5-22 NCP management

Step 2 Click Load NCP.

Step 3 On the pop-up window, click Browse to choose an .ncp file.

www.novastar.tech 20
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

Figure 5-23 Load NCP

Step 4 Select a cabinet file and display mode from the drop-down list and then click Load.

Step 5 Click Send to Receiving Card.

Step 6 On the pop-up window, select the target receiving cards and click Send.
 All Receiving Card: Send the receiving card configuration information to all the receiving cards loaded by the
current sending card. If you select Reset the Starting Coordinate of Receiving Card, the starting coordinates of
all the receiving cards will be reset to (0, 0). As a result, all the receiving cards display the top-left image of the
input source.
 Specified Receiving Card: Send the receiving card configuration information to the specified cards by sending
card, by topology, or by physical address.

Step 7 Click Save to HW.

Step 8 Do the following as required.


 Read cabinet information

Click Read Cabinet Info, set the receiving card address on the pop-up window, and then click OK.

 Restore NCP

a. Click Restore NCP.


b. On the pop-up window, select the receiving cards you want to restore.
On the Send by Topology tab, you can click Check Backup Files to check if there is a backup file in the
receiving card factory area.
c. Click Restore Specified Rv Cards to restore the backup file in the factory area to DDR.
d. Click Save to All Rv Cards.

www.novastar.tech 21
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

 Set cabinet rotation

Select Cabinet Rotation, set the rotation angle, and then click Send Parameters.
 Set receiving card indicator

Select Rv Card Indicator, choose between Enable or Disable, and then click Send Parameters.

5.2.3 Step 3 Connect Screen

Applications
Connect the receiving cards logically. Generally, one receiving card loads one cabinet. Therefore, this function is also
called connecting cabinets.

Applicable Products
 Configuration of standard screen: Applicable to all sending cards

 Configuration of complex screen: The DVI connector of the MCTRL1600 cannot be used to configure a complex
screen. You must use its DP 1.2 connector. The E8000 cannot be used to configure a complex screen.

Prerequisites
None

Related Information
In NovaLCT, you can configure up to 20 screens.
To configure a complex screen efficiently, you are advised to configure a standard screen first and then configure the
complex screen based on the standard screen.

Operating Procedure
Step 1 On the Screen Configuration page, click the Screen Connection tab.

www.novastar.tech 22
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

Step 2 Set the screen quantity and click Configure.

If the multiple output ports of the sending card load the different areas of the same screen, set the screen quantity to
1. If the multiple output ports of the sending card load different screens, set the screen quantity to the number of
screens loaded.

Step 3 On the Standard Screen page, set the column and row quantity of receiving cards. For example, set them to 10
columns and 5 rows respectively, as shown in Figure 5-24.

Figure 5-24 Column and row quantity of receiving cards

Step 4 Choose an output port.

Step 5 Set the receiving card size (loading capacity) and connection. For example, Figure 5-25 illustrates setting of the
receiving cards loaded by output port 1.
 Custom connection: In the table, click or drag the mouse.

 Quick connection: Click a connection pattern and drag the mouse to select an area in the table.

During connection, the loading capacity of all the receiving cards is the value you set by default. If necessary, you can
change the width and height of the loading capacity on the left.

Figure 5-25 Receiving card connection and size

www.novastar.tech 23
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

 Apply to Entire Column: Apply the loading capacity width of the selected receiving card to all the receiving cards in
the same column.
 Apply to Entire Row: Apply the loading capacity height of the selected receiving card to all the receiving cards in
the same row.
 Apply to the Current Port: Apply the current loading capacity width and height to all the receiving cards connected
to the current output port.
 Reset All: Reset all the receiving card connections and blanks.

 Hided Mapping Line: Hide the receiving card mapping line (namely the connections).

 : Mark the receiving card.

 : Return to the previous step of connection.

 : Clear all the connections of receiving cards connected to the current output port.
 Zoom: Zoom in or out the receiving card interface in the middle. When the interface is large enough, cabinet
related information is displayed.
 Port Capacity: View the usage rate of Ethernet ports.

Step 6 Set the specified receiving cards blank and set the blank size, as shown in the example in Figure 5-26. If you do not
need to set blank, skip this step.

Click a receiving card and select Set Blank to leave the position of that receiving card blank. Continue clicking or
dragging the mouse on the empty cabinets to set blank on the other positions.
The receiving cards that are left blank do not load the screen to display the image, which helps to realize
configuration of complex screen.
The blank size must be set based on the loading capacities of the neighbor receiving cards. For example, the display
effect of both connection lines in Figure 5-27 is N shape. The areas in red boxes are loaded by the neighbor receiving
cards. Therefore, their blank size is set to 0.

Figure 5-26 Setting receiving card blank

Step 7 Repeat Step 4 to Step 6 to set the receiving cards loaded by the other output ports.

www.novastar.tech 24
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

Figure 5-27 Configuration completed

Notes
To configure a complex screen efficiently, you are advised to configure a standard screen first and then
configure the complex screen based on the standard screen by following the operations below.
After the standard screen is configured, select Complex Screen. The Complex Screen page shows the
connection diagram of the standard screen. The connection diagram in Figure 5-26 is shown as the diagram in
Figure 5-28.
You can directly drag cabinets on the left or adjust data in the table on the right to let the configuration meet the
actual screen configuration requirements.

Figure 5-28 Configuration of complex screen

Step 8 Click Send to HW to send the configuration information to the hardware. If necessary, click Save to File to save the
configuration information as a file.

Empty cabinets cannot exist before saving configuration. You can set the empty cabinets blank.
Step 9 After the settings are done, click Save to save the configuration information to the hardware.

Step 10 After successful saving, choose whether to save the backup file to the local computer.

www.novastar.tech 25
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

When the control computer can access the Internet, you can use the backup file to register screens to VNNOX Care.
For details, see 7.1.2.1 Register by Using Local Backup Files (Recommended).
This step is related with the configuration of the save function. See 11.2 Set Main Window Starting Position

Applications
Set the coordinates of the top-left corner of the main window of NovaLCT on the desktop, and make the window
display in the specified position when the software is started.

Applicable Products
N/A

Prerequisites
None

Related Information
None

Operating Procedure
Step 1 On the menu bar, choose Settings > The Main Window Starting Position.

Figure 5-29 Setting starting position coordinates

Step 2 Set the coordinates of the top-left corner of the main window on the desktop, and click OK.

After the settings are done, the main window moves to the specified position. When next time NovaLCT is started, the
main window will be displayed in the target position.
Configure the Save Function.

Related Operations
 Detect Communication Status: Detect the status of connection between the receiving card and Ethernet port.

 Read the Number of Receiving Cards: Read the number of receiving cards connected to the current Ethernet port.

 Test Pattern: Display test patterns through the sending card, receiving card, or Ethernet port. Additionally, you can
perform screen controls like normal display or blackout.
 Enable Mapping: Enable the Mapping function. The Mapping function is for you to obtain the receiving card
connection information conveniently.
 Read from HW: Read the current configuration information in the hardware.

 Coordinate: Set the start position of the display image on screen.


 Virtual Mode: For modules with shared pixels (sub-pixels), you can check the Enable checkbox and then click
to set the parameters for virtual pixels.

www.novastar.tech 26
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

− Balanced Mode: Suited for standard display scenarios.


− Meeting Mode: Suited for displaying documents.
− Image Mode: Suited for displaying images and videos.
 Enable Sync: Used for the mosaic function of the all-in-one device

 Back Up System Configuration: Back up some system configurations, sending card configurations and receiving
card configurations to the local computer. This button is available for the MCTRL660 PRO device only.
 Restore System Configuration: Use the backup file (.pbk) to restore the system configurations, sending card
configurations and receiving card configurations. This button is available for the MCTRL660 PRO device only.

5.2.4 Step 4 (Optional) Save Configuration Files

Applications
After the screen configuration is done, save the configuration file of the online screen to the cloud (VNNOX Care) and
the local computer, or save the configuration file of the offline screen to the local computer.

Applicable Products
All receiving cards and sending cards

Prerequisites
To save the configuration files to the cloud, the following conditions must be met:
 You have a valid VNNOX Care account.

 The control PC is connected to the Internet.

Related Information
When saving the configuration files of a screen that is not registered with the cloud, the screen will be registered with
VNNOX Care automatically. During registration, NovaLCT will automatically enable Automatic Refresh and Link to
NovaiCare in the monitoring configuration. If you want to set the refresh period, please see 7.2 View and Configure
Monitoring.
The configuration files saved to the cloud include the receiving card configuration file (.rcfgx), screen connection file
(.scr), version file (.cfg), etc. The version file contains the version information about NovaLCT and the receiving card
program package.
The configuration files saved to the local computer include the system configuration file (.scfg) only.

www.novastar.tech 27
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

Operating Procedure (Online Screens)


Step 1 On the Screen Configuration page, click Save System Configuration File to open the dialog box shown in Figure
5-30.

Figure 5-30 Saving configuration files (online screen)

Step 2 Enter your VNNOX Care user name and password, set the screen name and system configuration file name, and
select a server node.

Step 3 After the parameter settings, click Save.

Step 4 After successful saving, close the prompt box.

Operating Procedure (Offline Screens)


Step 1 On the Screen Configuration page, click Save System Configuration File to open the dialog box shown in Figure
5-31.

www.novastar.tech 28
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

Figure 5-31 Saving configuration files (offline screen)

Step 2 Select a location from the control PC and click Save.

Step 3 After successful saving, click OK to close the prompt box.

5.3 Set Redundancy


Applications
Set device redundancy and Ethernet port redundancy to ensure high reliability of the control system in applications
like stage and conference center.

Applicable Products
 Redundancy: Applicable to all sending cards

 Hot backup verification: Applicable to the MCTRL4K, MCTRL R5 and KT8 sending cards

Prerequisites
Redundancy related hardware connection is done. The devices are cascaded before you set device redundancy and
Ethernet port redundancy between devices.

Related Information
Use the hot backup verification function to directly verify effectiveness of backup Ethernet ports without disconnecting
and reconnecting Ethernet cables.

Operating Procedure
Step 1 On the menu bar, choose User > Advanced Synchronous System User Login. Enter the password and click OK.

The default password is “admin”.

Step 2 Click or choose Settings > Screen Configuration from the menu bar.

Step 3 On the pop-up dialog box, select a communication port and choose Configure Screen. Then, select Next.

www.novastar.tech 29
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

Figure 5-32 Screen configuration method

Step 4 On the Sending Card tab page, perform any of the following operations as required.

Configure device redundancy


− Set a single device
Select Set as Primary or Set as Backup to set the current device as the primary or backup device.

− Set multiple devices


Click Set in the Redundancy area to open the Redundancy settings dialog box. Then, select Set as
Primary or Set as Backup. At last, select the sending cards you want to set and click Set.

Notes
To set a single backup device as the primary device, deselect Set as Backup first, send the settings to
the hardware and then select Set as Primary.
The sending card that is used in the completed screen configuration cannot be set as backup device. To
set it as backup device, you must delete the screen configuration information first.

Configure Ethernet port redundancy


a. Click Add to open the Redundancy Settings dialog box.

www.novastar.tech 30
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

b. Enter the serial numbers of the sending cards and output ports, and click Add.
For Ethernet port redundancy within a sending card, enter the same value for serial numbers of the
primary and backup sending card. For Ethernet port redundancy between sending cards, enter the actual
serial numbers of the primary and backup sending cards after they are cascaded.
c. After the configurations are done, click Close.

Step 5 (Optional) After Ethernet port redundancy is configured, perform the following operations to verify hot backup.

1. Click Verify to open the dialog box shown in Figure 5-33.


2. Select the sending card and click Enable Hot Backup Verification. If the display is normal, the backup
Ethernet port is effective, otherwise it is not.
3. After verification, click OK.
4. Click Disable Hot Backup Verification and click OK.
5. Close the Hot Backup Verification dialog box.

Figure 5-33 Hot backup verification

Step 6 Click Send to send the configuration information to the hardware, or click Save to save the information to the
hardware.

Step 7 After successful saving, choose whether to save the backup file to the local computer.

When the control computer can access the Internet, you can use the backup file to register screens to VNNOX Care.
For details, see 7.1.2.1 Register by Using Local Backup Files (Recommended).

This step is related with the configuration of the save function. See 11.2 Set Main Window Starting Position

Applications
Set the coordinates of the top-left corner of the main window of NovaLCT on the desktop, and make the window
display in the specified position when the software is started.

Applicable Products
N/A

Prerequisites
None

Related Information
None

www.novastar.tech 31
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

Operating Procedure
Step 1 On the menu bar, choose Settings > The Main Window Starting Position.

Figure 5-34 Setting starting position coordinates

Step 2 Set the coordinates of the top-left corner of the main window on the desktop, and click OK.

After the settings are done, the main window moves to the specified position. When next time NovaLCT is started, the
main window will be displayed in the target position.

Configure the Save Function.

5.4 Enable 3D
Applications
Enable the 3D function and set the related parameters to let users wearing 3D glasses enjoy stereoscopic images.

Applicable Products
The MCTRL4K, MCTRL1600, KT8, KT8E, KT16E, KT16C, MEE200 and MEE400 sending cards, and H series
products

Prerequisites
The 3D and low latency functions cannot be enabled at the same time. The low latency function must be disabled
before enabling 3D function.
The hardware connection is done and the 3D glasses are prepared.

Related Information
After the 3D function is enabled, the loading capacity of the sending card is reduced by half.

Operating Procedure
Step 1 On the menu bar, choose User > Advanced Synchronous System User Login. Enter the password and click OK.

The default password is “admin”.

Step 2 Click or choose Settings > Screen Configuration from the menu bar.

Step 3 On the pop-up dialog box, select a communication port and choose Configure Screen. Then, select Next.

www.novastar.tech 32
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

Figure 5-35 Screen configuration method

Step 4 On the Sending Card tab page, select Enable in the 3D Function area.

Figure 5-36 Enabling 3D

Step 5 Click Settings next to Enable to open the dialog box shown in Figure 5-37.

Figure 5-37 Setting 3D parameters

Step 6 Click Load from File to quickly configure the related parameters, or configure them manually.
 Video Source Format: Set the format of the video source to side-by-side, top-and-bottom or frame sequential
according to the format of the used video source.

www.novastar.tech 33
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

 Eye Priority: Set which image is sent first, the left eye image or the right eye image. Wear the 3D glasses and
watch the display. If the display is abnormal, set the parameter value to the other one. If the display is normal, the
setting is done.
 Mode Selection: Select the same or different signal sources for the left and right eye images. If there is only one
input source, this parameter is not displayed.
 Right Eye Start: Set the start position of the right eye image. When the video source format is side-by-side or top-
and-bottom and the left and right eye images are provided, this parameter can be set.
 3D signal emitter: If you use a third-party 3D emitter, select Enable third-party emitter. If you use the EMT200
emitter of NovaStar, do not select it.
 Signal Delay Time: Set the delay time of sending the synchronization signal from 3D signal emitter to the 3D
glasses. This setting ensures that the switching between left and right eye images of the 3D glasses is in sync
with the switching between the left and right images on the display. This parameter is applicable to both the
NovaStar and third-party emitters.

Step 7 After the configurations are done, click Save to save the configuration information to the hardware.

The 3D parameters take effect on the hardware immediately after they are configured. If they are saved to the
hardware, they will not be lost even after the device is powered off.

Step 8 (Optional) Click Save to File to save the configuration information as a file on the local computer.

5.5 Set Working Mode


Applications
Set the working mode to let the device switch to the sending card mode (also known as video controller mode) or the
fiber converter mode.

Applicable Products
The MCTRL660 PRO, MCTRL1600, H9, NovaPro UHD Jr, K16, and MCTRL R5 sending cards

Prerequisites
None

Related Information
For the MCTRL1600, H9, NovaPro UHD Jr and K16, after their working mode is set to sending card mode, you can
further set the working mode of their optical ports. The working modes of optical port include hot backup mode and
copy mode.
Figure 5-38 and Figure 5-39 are illustrations of the two optical port working modes, using the NovaPro UHD Jr as an
example.
 Hot backup mode: The sending card sends the two duplicate optical signals to the same display through the
primary and backup fiber converters to form a loop backup.
 Copy mode: The sending card sends the two duplicate optical signals to two displays through two fiber converters.

www.novastar.tech 34
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

Figure 5-38 Hardware connection for optical port hot backup mode

Figure 5-39 Hardware connection for optical port copy mode

Operating Procedure
Step 1 On the menu bar, choose User > Advanced Synchronous System User Login. Enter the password and click OK.

The default password is “admin”.

Step 2 Click or choose Settings > Screen Configuration from the menu bar.

Step 3 On the pop-up dialog box, select a communication port and choose Configure Screen. Then, select Next.

www.novastar.tech 35
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

Figure 5-40 Screen configuration method

Step 4 On the Sending Card tab page, click Set Working Mode.

Figure 5-41 Working mode

Step 5 Select the sending card and set the working mode to sending card mode or fiber converter mode.

Figure 5-42 Setting working mode

Step 6 For the MCTRL1600, H9, NovaPro UHD Jr and K16, after their working mode is set to sending card mode, if
necessary, set the working mode of their optical ports.

Step 7 Click OK.

5.6 Enable Zoom


Applications
Enable the zoom function and set the output resolution to let the image be displayed in a specified size.

Applicable Products
The KT8E, KT16E, KT16C, MEE200 and MEE400 sending cards

Prerequisites
None

Related Information
None

www.novastar.tech 36
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

Operating Procedure
Step 1 On the menu bar, choose User > Advanced Synchronous System User Login. Enter the password and click
Login.

The default password is “admin”.

Step 2 Click or choose Settings > Screen Configuration from the menu bar.

Step 3 On the pop-up dialog box, select a communication port and choose Configure Screen. Then, select Next.

Figure 5-43 Screen configuration method

Step 4 Click the Sending Card tab.

Step 5 Select Enable zoom and click OK.

Figure 5-44 Enabling zoom

Step 6 Set the output resolution.

Step 7 Click Set and click OK.

5.7 Set Audio Input


Applications
Set the audio input to HDMI or external audio.

Applicable Products
The sending card MCTRL2000

Prerequisites
None

Related Information
None

Operating Procedure
Step 1 On the menu bar, choose User > Advanced Synchronous System User Login. Enter the password and click OK.

The default password is “admin”.

Step 2 Click or choose Settings > Screen Configuration from the menu bar.
www.novastar.tech 37
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

Step 3 On the pop-up dialog box, select a communication port and choose Configure Screen. Then, select Next.

Figure 5-45 Screen configuration method

Step 4 Select the Sending Card tab.

Step 5 Select HDMI or External Audio from the drop-down list and then click Send.

Figure 5-46 Audio input

5.8 Set Performance Parameters


Applications
Set the performance parameters of the cabinet to let the screen present better display effect.

Applicable Products
All receiving cards

Prerequisites
None

Related Information
None

Operating Procedure
Step 1 On the menu bar, choose User > Advanced Synchronous System User Login. Enter the password and click OK.

The default password is “admin”.

Step 2 Click or choose Settings > Screen Configuration from the menu bar.

Step 3 On the pop-up dialog box, select a communication port and choose Configure Screen. Then, select Next.

www.novastar.tech 38
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

Figure 5-47 Screen configuration method

Step 4 Click the Receiving Card tab and click Read from Receiving Card to obtain the latest configuration information.

Step 5 If you have a receiving card configuration file (.rcfgx/.rcfg), click Load from File to complete the configuration quickly.
If do not have the file, preform the subsequent operations to manually configure the performance.

Step 6 In the Performance Settings area, set the performance parameters.

The performance parameters displayed in the area varies depending on the receiving card. The main parameters
include the followings.
 Refresh Rate: Indicates the rate of updating the image on the display. Increasing refresh rate reduces image
flickering, allowing for a more stable image.
 Grayscale Level: Indicates the shading of display. The higher the grayscale level, the more brightness levels the
display will have. For example, if the grayscale level is 16bit, the display can express 65,536 levels of brightness.
 Grayscale Mode: Indicates the grayscale display mode. It includes brightness first, refreshing rate first, grayscale
first and performance balancing.
 DCLK Frequency: Indicates the frequency of shift clock.

 DCLK Duty Cycle: Indicates the duty cycle of shift clock. Set it to 50% in general.

 DCLK Phase: Indicates the phase of shift clock. When there are mismatching or flashing pixels, adjust this
parameter to fix the problem.
 Refresh Rate Times: Indicates the times of refresh rate.

 Low Grayscale Compensation: Indicates the compensation for the grayscale in low grayscale conditions, allowing
for more precise grayscale.
 Row Blanking Time: Used to adjust the ghost problem of the scanning type display. If the ghost problem is serious,
increase the parameter value.
 Line Changing Time: Works with row blanking time to adjust the ghost of the scanning type display.

 Ghost Control Ending Time: Works with row blanking time and line changing time to adjust the ghost of the
scanning type display.
 Line break trimming: Works with row blanking time to adjust the ghost of the scanning type display.

 GCLK Frequency: Indicates the frequency of grayscale clock.

 GCLK Duty Cycle: Indicates the duty cycle of grayscale clock.

 GCLK Phase: Indicates the phase of grayscale clock.

www.novastar.tech 39
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

 Blanking Time Height: Used to eliminate the lower ghost

 Minimum OE Width: It is calculated from other performance parameters and can be viewed only.

 Brightness Efficiency: It is calculated from other performance parameters and can be viewed only.

Step 7 After the settings are done, click Send Performance Parameters to send the performance parameters to the
hardware.

Step 8 After the display effect meets the expectation, click Save to save the performance parameters to the hardware.

Step 9 After successful saving, choose whether to save the backup file to the local computer.

When the control computer can access the Internet, you can use the backup file to register screens to VNNOX Care.
For details, see 7.1.2.1 Register by Using Local Backup Files (Recommended).

This step is related with the configuration of the save function. See 11.3 Configure the Save Function

Data Group Exchange


This function is used to exchange every two data groups to adjust the display image. It can be performed only after
the smart settings are done and supports regular cabinets only. For example, after you exchange the data groups A
and B, data group A outputs the image of data group B, and data group B outputs the image of data group A.
Click Data Group Exchange, select all the receiving cards or specify one receiving card and click OK to open the
Data set exchange dialog box. If the module height is less than 8 or the width is less than 20, the data group
exchange is in group mode, otherwise it is in intuition mode.
The red table on the desktop indicates the original data groups. Each row is a data group. The first row is the first
data group.
To display the test pattern by data groups, check Enable Data Group Display and specify the data group number.
Intuition Mode
Select Enable data exchange and view the data group No. displayed on the screen. In the dialog box, double
click the rows with the same No. in the second column and change the numbers.
Example:
The receiving card has two data groups in parallel output. The screen displays 5 and 6, indicating that it outputs
the images of data group 5 and data group 6.
In the Data set exchange dialog box, change 5 to 1, 6 to 2, 1 to 5, and 2 to 6, as shown in the figure below.

Click Send. The screen displays 1 and 2, indicating that it outputs the images of data group 1 and data group 2
after data group exchange.
Group Mode
Select Enable data exchange and check whether the screen has a white area. If it has no white area, click No
flashing area. The white row in the red table moves to the next data group. If it has a white area, click the data
group you want to exchange in the Data set exchange dialog box.

www.novastar.tech 40
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

Example:
The receiving card has two data groups in parallel output. Click No flashing area multiple times and watch the
screen. When the white row in the red table moves to the fifth data group, the screen has a white area,
indicating that the screen outputs the image of data group 5.
In the Data set exchange dialog box, click the first data group. This exchanges data group 5 and data group 1.
The white row automatically moves to the sixth data group. Then, click the second data group in the Data set
exchange dialog box. This exchanges data group 6 and data group 2, as shown in the figure below.

After the settings are done, click Send to send the configuration information to receiving cards.

More Settings
Click More Settings to perform the following functions and set the extended attributes for the used chip.
Symmetrical/Data Group Extension
Set the output mode of data group, data group extension, hub mode and graphics output direction.

www.novastar.tech 41
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

− Output Mode: If the screen is very wide and the receiving card cannot load the entire width, set the output
mode to symmetrical outputs, triple strip outputs or quadruple strip outputs.
− Data Group Extension: If the receiving card supports data group extension, select the corresponding
option according to the actual condition.
− Ghost Control Signal: Use the default value.
− Hub Mode: Select a mode based on the receiving card specifications.
− Graphics Output: Use the default value.
Monitoring Card Data Line Adjustment
Adjust the data lines used by red, green, blue and virtual red LEDs during LED error detection.
Select Enable Adjustment of Monitoring Data Line and select Red, Green, Blue or Virtual Red from the
drop-down list. After the settings are done, click OK.

Additional Function
Enable or disable some additional functions of receiving card.

www.novastar.tech 42
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

The EMC function can be set to Disable, Weak, Medium or Strong. The other functions are described as
follows.
− Isolated Pixel Afterglow: Eliminate the afterglow problem of isolated pixels.
− Indicator Light of Receiving Card: Turn off the operating status indicator of receiving card.
− Shorten the synchronization time: Shorten the frame interval time during data output of receiving card.
− Brightness becomes strong slowly: Make the display become brighter slowly after the power is supplied.
− Linear: Increase the loading capacity of receiving card. The linear mode requires that the module
connection line is straight, the cabinet does not have data row extraction and the cabinet is not rotated.
− Auto Upload Module Calibration Coefficients: Once selected, if the control system detects a change in the
module ID upon power-up, it will automatically upload the calibration coefficients from the module flash to
the receiving card.
− Calibration Threshold: When the grayscale level is less than or equal to the specified level, use the
average calibration coefficients, other than the pixel level calibration coefficients. This fixes the display
problems in low grayscale after the screen is calibrated, such as mottling, color blocks and grayscale
spikes.
The R, G, and B values are hexadecimal and the largest value is FFFF. Before setting them, check the Y-
axis value corresponding to the X-axis value (the specified grayscale level) in the Gamma table in the
brightness adjustment function, and then convert the Y-axis value to hexadecimal value. If the device does
not support individual Gamma adjustment for RGB, set the R, G and B to the same value. The VR value
setting is optional.
The threshold coefficient is used to determine the transition mode of pixel level calibration below the
threshold value. The coefficient range is from 0.000 to 1.200, where 0 signifies no transition, rendering the
pixel level calibration ineffective straightaway. The larger the value, the more gradual the decrease in
effectiveness of the pixel level calibration.
− Delay Time of ABCDE Signals: Fix the problem that the afterglow cannot be eliminated because the
decoding signals are not synchronized. After the settings are done, click Apply.
Flash Arrangement
When the module has a flash memory, use this function to set the flash memory arrangement of cabinet. The
receiving card reads the calibration coefficients and module IDs from the flash memory via bus.
Before connecting the modules that have flash memory, obtain the bus No. A bus can cascade multiple modules.
Then, set the flash arrangement according to the actual connection order.

www.novastar.tech 43
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

a. Set the number of flash memory rows and columns. Generally, a module has one flash memory.
b. Click the bus No.
c. Set the width and height of the module controlled by the flash memory.
d. In the arrangement table, click the cells in order according to the actual module connection.
Right clicking a flash memory cell cancels the configuration of that flash memory. Clicking Back returns to
the previous operation. Clicking Apply to Current BUS sets all the flash memories connected to the
current bus to the same value.
e. Set the number of data groups of the module and the start coordinates of the flash memory.
f. Click Adjust Order to arrange the data group numbers as necessary.
g. If necessary, click the other bus to continue setting. After the configurations are done, click OK.
Monitoring Card Data Set Exchange
When the hardware connections of the monitoring card have errors, use this function to exchange the data
groups of the card without the need to reconnect the hardware.

a. Click Monitoring Card Data Set Exchange. In the displayed dialog box, select All Receiving Cards or
specify one receiving card and click OK.

www.novastar.tech 44
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

b. In the Monitoring card data set exchange dialog box, select Enable monitoring card data set
exchange.
c. Double click the row in the second column and change the value. For example, change 1 to 5, 2 to 6, 5 to
1, and 6 to 2, indicating that data group 1 is exchanged with data group 5 and data group 2 is exchanged
with data group 6.
d. After the settings are done, click Send to send the configuration information to the monitoring card.
Cabinet Information Settings
Set the weight, power, width, height, pixel width, pixel height and voltage of the cabinet base on the actual
situation.

5.9 Set Module Flash Parameters


Applications
Send or read the module flash parameters, and configure automatic readback upon power-up.

Applicable Products
For receiving cards that support read-write flash module.

Prerequisites
Modules with flash memory and the TBS 614 chip.

Related Information
None

Operating Procedure
Step 1 On the menu bar, choose User > Advanced Synchronous System User Login. Enter the password and click OK.

The default password is “admin”.

Step 2 Click or choose Settings > Screen Configuration from the menu bar.

Step 3 On the pop-up dialog box, select a communication port and choose Configure Screen. Then, select Next.

Figure 5-48 Screen configuration method

www.novastar.tech 45
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

Step 4 Click the Receiving Card tab and press the "NEC" (case sensitive) on your keyboard.

Step 5 Click the Write Flash Parameters that appears on the interface.

Figure 5-49 Receiving card

Step 6 Do the following as required.

Figure 5-50 Module flash parameters

 Send Parameters

Set the parameter version ID, and then click Save Parameters to Module Flash. In the Save Result dialog box,
you can check if the saving process was successful or not.
 Read Parameters

Click Read Configuration back to Rv Card, specify the location of the receiving card in the pop-up dialog box,
and click OK.
Check Parameter Readback to Rv Card on Power On and click Save Power-on Switch. If the parameter
versions of the module and receiving card are inconsistent when the control system is powered on, the
parameters in the module flash will be automatically read back to the receiving card.

www.novastar.tech 46
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

6 Brightness and Chroma Adjustment


6.1 Calibration
6.1.1 Set Online Calibration Parameters

Applications
Set parameters of displaying image and disable calibration or set calibration type during online calibration when
NovaLCT works with NovaCLB calibration software.

Applicable Products
 Full-grayscale calibration: Applicable to the A10s receiving card

 Low-grayscale calibration: Applicable to the A10s receiving card

 Dark or bright line correction: Applicable to the A8s receiving card

 Other functions: Applicable to all receiving cards and sending cards

Prerequisites
 Hardware setup is done.

 NovaCLB calibration software is installed.

Related Information
Screen calibration enables the brightness and chroma of LEDs to reach target values, allowing for balanced images
and better display effect.

Operating Procedure
Step 1 On the menu bar, choose User > Advanced Synchronous System User Login. Enter the password and click OK.

The default password is “admin”.

Step 2 Click or choose Tools > Calibration from the menu bar.

Figure 6-1 Screen calibration

www.novastar.tech 47
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

Step 3 Select the Single-Screen Mode tab or Combined-Screen Mode tab.

Step 4 In single-screen mode, select a communication port and screen. In combined-screen mode, skip this step.

Step 5 Set the displayed parameters.


 Position to Display Image: Choose to display the image of the primary or extended monitor on the screen.

 Device Response Time: In combined-screen mode, setting this parameter allows the display window to fit well
with the time for camera to take pictures.
 Method to Display Image: Select hardware test pattern or signal test pattern.

 Enable/Disable Calibration: You can select disable calibration, brightness calibration, chroma calibration, or full-
grayscale calibration. You can also select dark or bright line correction and low-grayscale calibration at the same
time. Click Save to apply your settings.

Step 6 If network monitoring succeeds, open NovaCLB and enter the local IP address and port number displayed on the
Online Calibration tab page of NovaLCT to connect NovaCLB to NovaLCT.

If network monitoring fails, click Reconnect, or change the port and then click Reconnect.

Step 7 (Optional) Click Export Log to export the communication log, or click Clear to clear the communication log.

6.1.2 Get Average Coefficients

Applications
Get the average coefficients of a specified area on a screen.

Applicable Products
All receiving cards

Prerequisites
None

Related Information
Offline calibration is not available for combined screens.

Operating Procedure
Step 1 On the menu bar, choose User > Advanced Synchronous System User Login. Enter the password and click OK.

The default password is “admin”.

Step 2 Click or choose Tools > Calibration from the menu bar.

Step 3 Select the Single-Screen Mode tab.

Step 4 Select a communication port and screen.

Step 5 Select the Offline Calibration tab.

www.novastar.tech 48
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

Figure 6-2 Offline calibration

Step 6 Specify an area where you want to get the average calibration coefficients.

Step 7 Click Get Average Coefficients.

Step 8 After the average calibration coefficients are obtained successfully, click OK.

Step 9 (Optional) Click Display or Hide to show or hide the display window.

6.1.3 Manage Calibration Coefficients

Applications
Upload, save, adjust, erase and reload calibration coefficients.

Applicable Products
 Full-grayscale calibration: Applicable to the A10s receiving card

 Low-grayscale calibration: Applicable to the A10s receiving card

 Dark or bright line correction: Applicable to the A8s receiving card

 Other functions: Applicable to all receiving cards

Prerequisites
 If you want to use a database file, you need to prepare it.

 Module flash management requires modules with flash memory.

Related Information
Calibration coefficient management is not available for combined screens.
Pixel level calibration database files fall into two types:
Screen calibration database file
Saves the coordinates and calibration coefficients of each pixel on a screen. After the location of a cabinet is
changed, the calibration coefficients cannot be uploaded to the cabinet.
Cabinet calibration database file

www.novastar.tech 49
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

Saves the coordinates and calibration coefficients of each pixel on a cabinet according to the cabinet number.
After the location of a cabinet is changed, the calibration coefficients can be uploaded to the cabinet according
to the cabinet number.
Module flash memory can store calibration coefficients and module IDs. In the event of network outage, you can hold
down the self-test button for 2 seconds to read the calibration coefficients in module flash memory back to the
receiving card.

Operating Procedure
Step 1 On the menu bar, choose User > Advanced Synchronous System User Login. Enter the password and click OK.

The default password is “admin”.

Step 2 Click or choose Tools > Calibration from the menu bar.

Step 3 Select the Single-Screen Mode tab.

Step 4 Select a communication port and screen.

Step 5 Select the Manage Coefficients tab.

Figure 6-3 Calibration coefficient management

Step 6 Perform the following operations as required. During the operation, you can select Disable Calibration, Brightness
Calibration, Chroma Calibration, or Full-grayscale Calibration on the left. Dark or Bright Line Correction and
Low-grayscale Calibration can also be selected at the same time. After saving, you can view the effect of applied
coefficients on the screen.

Upload coefficients
− Pixel level calibration database: Select the cabinet or screen calibration database file from the local
computer and fast or stably upload the calibration coefficients to receiving cards.
− Dark or bright line database: Select the dark or bright line correction database file from the local computer
and stably upload the calibration coefficients to receiving cards.
− Full-Grayscale Calibration Database: Select the full-grayscale calibration database file from the local
computer and stably upload the calibration coefficients to receiving cards.
Stable uploading takes more time than fast uploading, but it is more stable and reliable.
Save calibration coefficients to database

www.novastar.tech 50
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

Save the calibration coefficients in the receiving cards to an existing or new database. The coefficients for full-
grayscale calibration will also be saved if Full-Grayscale is selected.
Set coefficients for a new receiving card
Get calibration coefficients by uploading calibration database file or referring to one or more surrounding
cabinets. Adjust and save the coefficients to receiving cards as required.
Set coefficients for a new module
Get calibration coefficients by uploading calibration database file or referring to one or more surrounding
modules. Adjust and save the coefficients to receiving cards as required.
Adjust coefficients (Color is not uniform on screen)
Adjust the current calibration coefficients of receiving cards or adjust the coefficients by referring to the
surrounding area. After the adjustment, you can also apply the coefficients to other specified areas.
Erase or reload calibration coefficients
Erase the calibration coefficients in the application areas of receiving cards or reload calibration coefficients
from application areas. You are advised to back up the database file before erasing it.
Reset calibration coefficients
Set calibration coefficients to specified values.
Upload coefficients (for factory use)
Upload the calibration coefficients from the cabinet calibration database file to the matching cabinets based on
the imported or read cabinet ID. Export the full-screen cabinet ID file and the full-screen calibration database file.
For the module, read the module ID and upload the calibration coefficients from the module calibration database
file to the corresponding modules. While stable uploading takes longer than fast uploading, it is more reliable.
Module Flash
Check module flash memory status, view the calibration coefficients of modules and receiving cards, and save
calibration coefficients to the receiving cards and modules based on their addresses or the topology.
Type “admin” with your keyboard. The Save Calibration Coefficients to Module button is displayed.
− Coef Type: The calibration coefficient type, including brightness & chroma coef, low-grayscale coef, full-
grayscale coef, and adaptive coef.
− SPI Bit Rate Level: The speed level of reading and uploading the calibration coefficients, 4 levels included
− Auto Upload Module Calibration Coefficients: When this function is selected, if the system detects that a
cabinet ID is changed after the control system is powered on, the calibration coefficients in the module
flash memory will be automatically uploaded to the receiving card.
Upload thermal compensation coefficients
Import the thermal compensation coefficient file or read the coefficients from the hardware to adjust the red,
green and blue coefficients individually, and send and save the coefficients.
− Adjust: Set the stepping of adjusting the coefficients.
− Enable Temperature Calibration Coefs: Apply the coefficients and check the effect on the screen.
− Clear: Clear the pixel level brightness and chroma calibration coefficients.
− Export: Export the thermal coefficient file.
− Erase: Erase the thermal coefficients.

Notes
Types and causes of module flash memory check errors:
 Hardware Fault: Screen configuration or flash topology is not consistent with the actual condition.
 Communication Error: There is a problem with hardware connection.
 Flash Topology Error: The module does not have flash memory or no flash topology is configured in
Screen Configuration.
The Coef Type parameter value include brightness & chroma coefficient, low-grayscale coefficient and full-
grayscale coefficient. To set that parameter value to low-grayscale coefficient or full-grayscale coefficient,
ensure that both the driver chip and receiving card support low-grayscale coefficient or full-grayscale
coefficient.

Related Operations
During coefficient management, three methods are provided for you to select an area for coefficient management.
www.novastar.tech 51
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

Figure 6-4 Selecting an area for coefficient management

 Full screen: Manage the coefficients of the entire screen.

 Select by pixel area: Manage the coefficients of a specified area.

For full-grayscale calibration database file, the parameter Upload by area is displayed at the bottom of the page.
If you want to upload the data of full-grayscale database split by the split tool to a certain location, please select
Upload by area and set other parameters.
 Select by Topology or List: Manage the coefficients of a specified cabinet, module or pixels. For a standard screen,
a cabinet topology is displayed. For a complex screen, a cabinet list is displayed. If it is not convenient to select
an area with the software, you can select Select Area on Screen to select the area on the display window.
Two methods are provided for calibration coefficient adjustment. You can display or hide the color window during the
adjustment.
Simple Adjustment
As shown in Figure 6-5, drag the slider to adjust the values of red, green and blue. Click Advanced Adjustment
to open advanced adjustment page.
Advanced Adjustment
As shown in Figure 6-6, drag the slider to adjust the brightness, saturation and hue for red, green and blue, and
adjust color temperature. Click Simple Adjustment to go back to simple adjustment page.

Figure 6-5 Simple adjustment

www.novastar.tech 52
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

Figure 6-6 Advanced adjustment

6.1.4 Manage Double Calibration Coefficients

Applications
View calibration coefficients saved in the application area and factory area, get calibration coefficients in the factory
area, and save calibration coefficients to the factory area.

Applicable Products
The A5, A5s, A7, A7s, A8, A8s, A9s and A10s Plus receiving cards

Prerequisites
None

Related Information
Calibration coefficients can be saved in both the factory area and application area of a receiving card. A copy of
coefficients is saved in the factory area before a cabinet leaves the factory. The calibration coefficients usually used
by users are in the application area. If necessary, calibration coefficients in the factory area can be restored to the
application area.

Operating Procedure
Step 1 On the menu bar, choose User > Advanced Synchronous System User Login. Enter the password and click OK.

The default password is “admin”.

Step 2 Click or choose Tools > Calibration from the menu bar.

Step 3 Select the Single-Screen Mode tab or Combined-Screen Mode tab.

Step 4 In single-screen mode, select a communication port and a screen. In combined-screen mode, skip this step.

Step 5 Select the Double Calibration Coefficients tab.

www.novastar.tech 53
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

Figure 6-7 Managing double calibration coefficients

Step 6 Perform the following operations as required.

View calibration coefficients in application area


Click View calibration coefficients in application area, select Disable Calibration, Brightness Calibration or
Chroma Calibration, and view the application result of calibration coefficients on the screen.
View calibration coefficients in factory area
Click View calibration coefficients in factory area, select Disable Calibration, Brightness Calibration or Chroma
Calibration, and view the application result of calibration coefficients on the screen.
Get calibration coefficients in factory area
Click Acquisition of factory area correction factor to restore the calibration coefficients from factory area to
application area.
Save calibration coefficients to factory area
Type “admin” with your keyboard. A Save coefficients to factory area button is displayed. Click the button to
save the calibration coefficients in the application area to factory area.

6.1.5 Set Thermal Compensation

Applications
Enable or disable thermal compensation and adjust its application strength.

Applicable Products
Receiving cards: A8s Pro and A10s Pro

Prerequisites
The firmware version of the receiving card is V1.2.0.0 or above and includes thermal compensation coefficients.

Related Information
None

www.novastar.tech 54
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

Operating Procedure
Step 1 On the menu bar, choose User > Advanced Synchronous System User Login. Enter the password and click OK.

The default password is “admin”.

Step 2 Choose Settings > Thermal Compensation from the menu bar.

Figure 6-8 Thermal compensation

Step 3 Select a communication port from the drop-down list.

Step 4 To select the target cabinets, choose between Full Screen, Select by Ethernet Port, or Select by Cabinet.

Step 5 Toggle on Thermal Compensation and adjust the application strength.

Step 6 Click Save to HW.

6.2 Adjust Brightness


6.2.1 Adjust Brightness Manually

Applications
Manually adjust the scree brightness, Gamma, color temperature and color space to change the brightness and
chroma expressiveness of the screen in real time, meeting the environment condition and user needs.

Applicable Products
 Individual Gamma adjustment for RGB:

− If the bit depth of input source for the sending card is 8bit, the applicable receiving cards include the A4,
A4s, A5, A5s, A5s Plus, A7, A7s, A7s Plus, A8, A8s, A9s, A10s Plus, DH7512 and DH3208.
− If the bit depth of input source for the sending card is 10bit or 12bit, the applicable sending cards include
the MCTRL1600, MCTRL4K, MCTRL660 PRO, KT8, KT8E, KT16E, KT16C, MCTRL R5, MEE200 and
MEE400.

www.novastar.tech 55
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

 Gamma interlink: Applicable to receiving cards with TBS6332 or TBS6336 chips.

 Other functions: Applicable to all receiving cards and sending cards

Prerequisites
None

Related Information
Manual brightness adjustment is to set screen brightness manually. After NovaLCT is opened, you can directly
perform the steps in Operating Procedure. After logging in to NovaLCT, you can also perform the operations in
Custom Gamma, Custom Color Temperature and Custom Color Space of this section.
If the ambient brightness is high, adjust the screen brightness to a higher level to ensure clear display. If the ambient
brightness is low, adjust the screen brightness to a lower level to reduce light pollution.

Operating Procedure

Step 1 Click or choose Settings > Brightness from the menu bar.

Step 2 Select Manual Adjustment.

Step 3 Drag the slider to adjust brightness and select Grayscale or Contrast. You can also set Gamma Interlink if the
screen is using receiving cards with TBS6332 or TBS6336 chips.

Figure 6-9 Manual brightness adjustment

Step 4 Do the following as required:

Adjust Gamma and low grayscale slope


Drag the slider to adjust Gamma value and low grayscale slope.
Adjust color temperature
Choose Rough Adjustment and drag the slider to adjust the color temperature. Or choose Precise

Adjustment and click a custom color temperature to use it, such as .

www.novastar.tech 56
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

Adjust color space


Disable color space, enable a standard color space (PAL/NTSC), or enable a custom color space, such as

Notes
After logging in to NovaLCT, you can set custom Gamma, custom color temperature and custom color space.
For details, see Custom Gamma, Custom Color Temperature and Custom Color Space.

Step 5 After the configuration is done, click Save to HW to save the configuration to the hardware.

Custom Gamma
Step 1 On the Gamma Adjustment page, select Custom Gamma Adjustment.

Step 2 Click Configuration to open the dialog box shown in Figure 6-10.

Figure 6-10 Custom Gamma adjustment

Step 3 If the control system supports individual Gamma adjustment for RGB, select White to adjust the Gamma curves for
red, green and blue at the same time. Or, select Red Gamma, Green Gamma, or Blue Gamma to adjust the
Gamma curve for a single color. If the control system does not support individual Gamma adjustment for RGB, skip
this step.

Step 4 Perform any of the following operations as required to configure the Gamma curve.

Gamma readback
Click Readback to read the gamma information.
Load a Gamma configuration file
Click Load to load a Gamma configuration file.
Adjust the Gamma manually
Drag the slider to adjust the Gamma value and low grayscale slope.
Adjust the Gamma table manually
Double click a value in the Y column to edit the value, and select a value in the Y column and click Move Up or
Move Down.

Step 5 After the settings are done, click Send to send the configuration to the hardware.

Step 6 (Optional) Click Save to save the Gamma information as a configuration file.
www.novastar.tech 57
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

Custom Color Temperature


Step 1 On the Color Temperature Adjustment page, select Precise Adjustment.

Step 2 Click to open the dialog box shown in Figure 6-11.

Figure 6-11 Custom color temperature

Step 3 If you have a color temperature configuration file (.fcg), click Import to complete the configuration quickly. If you do
not have a color temperature configuration file, continue performing the following operations to manually complete the
configuration.

Step 4 Click Add to open the dialog box shown in Figure 6-12.

Figure 6-12 Adding color temperature information

Step 5 Click Add Brightness to open the dialog box shown in Figure 6-13.

www.novastar.tech 58
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

Figure 6-13 Adding brightness information

Step 6 Add color temperature information corresponding to the specified brightness values.

Current Gain is a color temperature parameter of modules. This parameter can be set when supported by module
chips. Brightness Component is a color temperature parameter of receiving cards. If Synchronize is selected, the
R, G and B parameters will be set to the same value. You can edit, delete and clear the color temperature information
if necessary.

Step 7 After the configuration is done, click Save to local to save the custom color temperature. A corresponding button will
be displayed next to Precise Adjustment.

Step 8 (Optional) Click Export to save the current color temperature information as a configuration file.

Custom Color Space

Step 1 On the Color Space Adjustment page, click to open the dialog box shown in Figure 6-14.

Figure 6-14 Custom color space

Step 2 Set the original color space.


www.novastar.tech 59
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

The white triangle represents the original color space. The target color space is configured based on the original color
space. You are advised to use a colorimeter to measure the original color space of the screen and then enter the
measured values in the original color space table.

Step 3 Perform any of the following operations as required to set custom color space.

Select a standard color space


Click PAL or NTSC to use one of the standard color spaces.
Select an existing custom color space

If there is a custom color space, click to use it. If not, click Import to import a custom color space, or click
to create a custom color space and then click to use it.
Adjust the color space diagram manually
Drag vertexes of the black triangle in the diagram on the left to adjust the target color space. If Draw black
lines and common color temperature points is selected, a black curve (color temperature curve) and some
common color temperature points (solid round spots) will be displayed in the diagram.
Adjust the color space values manually
Change the parameter values in the target color space table for precise adjustment.

Step 4 After the configuration is done, select Enable color space adjustment to apply the target color space, and click
Send to send the configuration information to the hardware.

Step 5 Click Save to HW to save the information to the hardware.

6.2.2 Adjust Brightness Automatically

Applications
Set rules for automatic brightness adjustment, allowing NovaLCT or sending cards to automatically adjust screen
brightness.

Applicable Products
All sending cards

Prerequisites
When screen brightness is adjusted based on ambient brightness, a light sensor must be connected to the sending
card or multifunction card.
If the light sensor is connected to the multifunction card, peripheral configuration needs to be completed on
multifunction card management page.

Related Information
After you configure the automatic brightness adjustment, two adjustment modes are provided.
Software adjustment mode
NovaLCT automatically adjusts screen brightness. This mode takes effect when the control PC is connected to
the sending card and monitoring is running. Combined-screen brightness, color temperature and Gamma must
be adjusted and night mode must be enabled with the software.
The adjustment process will be recorded as a log which can be exported and viewed in iCare of VNNOX cloud
platform.
Hardware adjustment mode
The sending card automatically adjusts screen brightness. This mode takes effect when the control PC and
sending card are disconnected or monitoring stops running.
Combined screens do not support this mode.
The adjustment process will not be recorded as a log.

Operating Procedure

Step 1 Click or choose Settings > Brightness from the menu bar.
www.novastar.tech 60
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

Step 2 Select Auto Adjustment.

Step 3 Click Wizard Settings.

If the auto adjustment table is configured, you can add, delete and modify items in the table, or click Light Sensor
Configuration to set light sensor information.

Step 4 Select an adjustment mode as required and click Next.

Advanced adjustment
Screen brightness is adjusted by time periods. You can choose to adjust screen brightness according to
specified brightness or ambient brightness.

a. Click Add.
a. Set the start time and adjustment method and then click OK.

b. Click More Settings to set color temperature and Gamma vale.


The options in the drop-down box next to color temperature are the custom color temperatures.
c. After the settings are done, click Cancel to close the dialog box.
As shown in the figure below, the two configuration items denote that screen brightness will be adjusted to
80% from 8:00 to 18:00 and adjusted to the corresponding values in the brightness mapping table
according to ambient brightness from 18:00 to 8:00 of the next day.

www.novastar.tech 61
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

d. If there is no Environment Brightness under Adjustment Method, click Finish. If there is Environment
Brightness under Adjustment Method, click Next and complete light sensor settings according to the
description in Light Sensor Adjustment below.
Light sensor adjustment
Screen brightness is adjusted according to ambient brightness. Set the corresponding relations between
ambient brightness and screen brightness in the ambient brightness mapping table.

a. Click Light Sensor Test to test the light sensors connected to the control system, including the light
sensors connected to all sending cards and multifunction cards.
If you want to clear the ineffective light sensor information, click Clear Failed Light Sensor Information.
b. (Optional) Select When the light sensor fails, the brightness should be adjusted to and set a
brightness value.
If this option is not selected, the screen brightness will keep the last updated brightness value when the
light sensor fails.

c. Click or , or click Fast Section Division to set the brightness mapping table.
Fast section division can equally divide the ambient brightness range and screen brightness range into the
specified number of segments.
d. (Optional) Select Opening to enable night mode and set the maximum brightness of the specified time
period.
When surrounding lights interfere with the light sensor or an exception occurs when the light sensor is
collecting ambient brightness data, screen brightness may be too high. This can be avoided in night mode.
If the start time and end time are the same, night mode takes effect all the time.
e. Click Finish.

Step 5 After the settings are done, click Save.

Step 6 (Optional) Click Export Log to export the brightness adjustment log in software adjustment mode.

Step 7 (Optional) Set the advanced parameters of auto brightness adjustment.

1. On the taskbar, click and choose Brightness Advanced Settings.

www.novastar.tech 62
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

2. Select Enable Brightness Gradient. Screen brightness will gradually change to the target value.
3. Set the cycle and number of times for the light sensor to measure ambient brightness.
For example, if the cycle is 60 seconds and number of times is 5, the light sensor will measure ambient
brightness every 60 seconds. After 5 times of measurement, NovaLCT will calculate the average of the
measured values without the maximum and minimum ones. This average value is ambient brightness. If
multiple light sensors are connected, NovaLCT will calculate the average of all the ambient brightness values.
4. Click Save.

6.3 Adjust Multi-batch Cabinets


Applications
Adjust the chroma of cabinets or modules from multiple batches to make the overall screen chroma more uniform.

Applicable Products
All receiving cards

Prerequisites
None

Related Information
None

Operating Procedure
Step 1 On the menu bar, choose Tools > Multi-batch Adjustment.

Step 2 Select Manual Adjustment.

If you have a configuration file, select Apply Adjustment File to quickly complete chroma adjustment for cabinets
from multiple batches.

www.novastar.tech 63
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

Figure 6-15 Multi-batch adjustment

Step 3 If no colorimeter is connected, select No Colorimeter. If a colorimeter is connected, select the colorimeter type and
set its measurement accuracy.

Step 4 Click Next.

Step 5 Set the parameters of a sample batch.

Figure 6-16 Setting sample batch

1. (Optional) Select Fixed Batches, Adjust Other Batches to The Batch.


Fixed sample batch is for reference and cannot be adjusted. All the sample batches can be adjusted without a
fixed batch.
2. Select a communication port and screen.
3. Select a position to display image.

4. Click to specify an operating area for the fixed sample batch.

www.novastar.tech 64
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

− Pixel: Perform operations in a specified area.


− Topology or List: Perform operations on a specified module or pixels. If it is not convenient to specify an
area with the software, you can select Select Area on Screen to specify an area on the display window.

5. Click , and in order to measure Brightness, Cx and Cy by using a


colorimeter and enter the measured values. If no colorimeter is connected, skip this step.

Step 6 Set other sample batches.

1. Import, add or delete other sample batches as required.


2. Select a sample batch and specify an operating area by following 4 in Step 5.
3. Enter the values measured by the colorimeter by following 5 in Step 5. If no colorimeter is connected, skip this
step.

Step 7 Click Next.

Step 8 View the preliminary adjustment result, select a result option and click Next. If no colorimeter is connected, skip this
step.

www.novastar.tech 65
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

Figure 6-17 View the preliminary adjustment result

Selecting Automatic Switching automatically switches the display color. Selecting Enable Correction allows you to
view the calibration result.
 If the calibration result is satisfactory, go to Step 10.

 If the calibration result is not satisfactory, go to Step 9.

Step 9 Fine tune the sample batch.

Figure 6-18 Fine tuning a sample batch

1. Select the sample batch to be displayed.


2. Select a display color.
3. Drag the slider to adjust brightness.
4. Select RGB or HIS and adjust the coefficients of red, green and blue.
You can click Withdraw to restore the coefficients.

www.novastar.tech 66
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

5. (Optional) Click Balanced and perform balanced adjustment for the sample batch in the dialog box that appears.
Click Balanced Description to see the detailed description of balanced adjustment.

6. Click Next.

Step 10 Select Adjust Color Temperature. Drag the slider to adjust color temperature and view the effect.

Figure 6-19 Adjusting color temperature

Step 11 After the adjustment is done, click Next.

Step 12 Click Add Areas to select the areas where the adjustment effect will be applied.

www.novastar.tech 67
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

Figure 6-20 Applying adjustment effect

Step 13 Click Display screen on LED display to view the adjustment effect.
 Enable Correction: After this option is selected, you can view the calibration result.

 Display All Batches: After this option is selected, all sample batches are displayed.

Step 14 Click Apply or Apply All.

Step 15 Click Save to Flash to save the configuration to the hardware.

Step 16 (Optional) Click Save File to save the configuration as a file (.lxy).

Step 17 Click Complete and OK.

6.4 Adjust Dark or Bright Lines


Applications
Adjust dark or bright lines between cabinets or modules to improve visual experience.

Applicable Products
All receiving cards

Prerequisites
None

Related Information
None

Operating Procedure
Step 1 On the menu bar, choose Tools > Quickly Adjust Dark or Bright Lines.

www.novastar.tech 68
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

Figure 6-21 Adjusting dark or bright lines

Step 2 By default, the software uses No Video Source and the hardware's test pattern. You can uncheck No Video Source
if needed.

Step 3 Click and then fill in the module width and height on the pop-up window to switch to module mode. You can also
click to switch to cabinet mode.

Step 4 For the calibration drop-down list ( ), make you choice between Off, Chroma Calibration, Brightness
Calibration, or Full-grayscale Calibration.

Step 5 Choose a test pattern color.

 : Show or hide the test pattern.

 : Show the test pattern on the main display or extended display.

Step 6 Drag the slider to adjust the screen brightness.

Step 7 Click or drag to select the edges you want to adjust. Set the adjustment precision and move the slider to adjust the
values. If you need to adjust by pixels, double-click the edge you want to modify, set the pixel range in the pop-up
window, adjust the precision, and move the slider to change the values.

 : Select the horizontal and vertical edges.

 : Only select the horizontal edges.


 : Only select the vertical edges.

 : Clear the effect of the selected edges.

 : Deselect.
 : Clear the effect of all edges.

 : Show or hide the flashing dashed lines on the screen.

 : Show or hide module/cabinet numbers.

 : Zoom out the topology.

 : Zoom in the topology.


 : Display the topology at a 1:1 ratio with the screen.

 : Auto fit the topology.

Step 8 Click Save to HW once you are done.

www.novastar.tech 69
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

6.5 Correct Brighter Pixels


Applications
Correct brightness of pixels that are brighter or darker than normal to fix the problem that the pixel brightness of the
screen is not uniform after calibration.

Applicable Products
All receiving cards and sending cards

Prerequisites
Cabinets of the screen are calibrated or the entire screen is calibrated and the cabinet or screen calibration database
file is saved.

Related Information
None

Operating Procedure
Step 1 On the menu bar, choose Tools > More > Brighter Pixel Correction.

Figure 6-22 Brighter pixel correction

Step 2 Select a screen.

Step 3 Select a position to display image.

Step 4 Set the brightness of the display window.

Step 5 Select a database type, for example, Cabinet.

Step 6 Click Browse and select a database file. For example, select a cabinet calibration database file and click Open.

Step 7 On the Topology page, select an area and then select the Simulation Diagram tab.

Step 8 Click brighter pixels or select the area where there are brighter pixels and click .

 : Click to select a brighter pixel.

 : Select brighter pixels by clicking and dragging the mouse to form a selection box.
www.novastar.tech 70
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

 : Select brighter pixels by clicking and dragging the mouse to form a selection oval.

Figure 6-23 Selecting brighter pixels

Step 9 Select Coefficient Adjustment or Advanced to adjust coefficients.

Step 10 After the settings are done, click Upload to save the configuration to the hardware.

Step 11 Click Save to HW to save the configuration to the hardware.

Step 12 (Optional) Click Save Database to save the configuration to the current database file.

6.6 Set Advanced Color


Applications
Improve the display effect of a screen by setting screen brightness, color space, color temperature, etc.

Applicable Products
 Color adjustment: Applicable to the NovaPro HD

 Other functions: Applicable to all sending cards

Prerequisites
None

Related Information
None

Operating Procedure
Step 1 On the menu bar, choose User > Advanced Synchronous System User Login. Enter the password and click OK.

The default password is “admin”.

Step 2 Choose Settings > Advanced Color Configuration.

Step 3 Click Import to quickly complete the configuration or continue performing the following operations to complete the
configuration manually.

Step 4 On the Factory Setting tab page, adjust parameters and then click Save to HW.

www.novastar.tech 71
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

Figure 6-24 Factory settings

 Current Gain: This is a module parameter and can be set when supported by module chips. Clicking Default
Value can reset the value.
 RGB Brightness: This is a receiving card parameter.

If Synchronize is selected, the R, G and B parameters will be set to the same value.

Step 5 Select Configure Color Space to set color space.

Figure 6-25 Configuring color space

www.novastar.tech 72
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

1. Set the original color space.


The white triangle represents the original color space. The target color space is configured based on the original
color space. You are advised to use a colorimeter to measure the original color space of the screen and then
enter the measured values in the original color space table.
2. Perform any of the following operations as required to set custom color space.
− Select a standard color space
Click PAL or NTSC to use one of the standard color spaces.
− Select an existing custom color space
If there is a custom color space, click to use it. If not, click Import to import a custom color space, or click
to create a custom color space and then click to use it.
− Adjust the color space diagram manually
Drag vertexes of the black triangle in the diagram on the left to adjust the target color space. If Draw black
lines and common color temperature point is selected, a black curve (color temperature curve) and
some common color temperature points (solid round spots) will be displayed in the diagram.
− Adjust the color space values manually
Change the parameter values in the target color space table for precise adjustment.
3. After the configuration is done, select Enable color space adjustment to apply the target color space, and click
Send to send the configuration information to the hardware.
4. Click Save to HW to save the configuration to the hardware.

Step 6 Select Color Temperature Table to set color temperature.

Figure 6-26 Color temperature table

1. Click Add to open the dialog box shown in Figure 6-27.


2. Click Add Brightness to open the dialog box shown in Figure 6-28.
3. Add color temperature information corresponding to specified brightness values.
Current Gain is a color temperature parameter of modules. The parameter can be set when module chips
support current gain. Brightness Component is a color temperature parameter of receiving card. If
Synchronize is selected, the R, G and B parameters will be set to the same value. You can edit, delete and
clear the color temperature information if necessary.
4. After the configuration is done, click Save to local to save the custom color temperature.

www.novastar.tech 73
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

Figure 6-27 Adding color temperature information

Figure 6-28 Adding brightness information

Step 7 For the NovaPro HD, select Color Adjustment to set the hue, contrast and saturation of the screen. This function is
not available for other products.

www.novastar.tech 74
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

Figure 6-29 Adjusting color

Step 8 (Optional) Click Export to save the configuration as a file.

6.7 Adjust Screen Effect


Applications
Enable 18bit+, ClearView and low latency, and set HDR parameters to improve display effect.

Applicable Products
 18bit+: Applicable to the A5s Plus, A7s Plus, A8, A8s, A10s Plus and DH7512 receiving cards

 ClearView: Applicable to the A8, A8s and A10s Plus receiving cards

 Low latency: Applicable to the A5s Plus, A6s, A8s, A10s Plus and AT60 receiving cards

 HDR: Applicable to the sending cards that support 10-bit or 12-bit input sources

Prerequisites
 During HDR settings, the hardware must support HDR and an HDR10 or HLG input source is also required.

 HDR and ClearView cannot be enabled simultaneously.

 Low latency and 3D function cannot be enabled simultaneously.

Related Information
18bit+ can improve LED display grayscale by 4 times, avoiding grayscale loss due to low brightness and allowing for
smoother images.
ClearView make texture, size, and contrast adjustments on different areas of the display image, creating a more
realistic image.
Enabling either sending card low latency or receiving card low latency can reduce the delay by one frame. Enabling
both can reduce the delay by two frames.

Operating Procedure
Step 1 On the menu bar, choose User > Advanced Synchronous System User Login. Enter the password and click OK.
www.novastar.tech 75
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

The default password is “admin”.

Step 2 Choose Settings > Adjust screen effect.

Figure 6-30 Screen effect adjustment (new)

Figure 6-31 Screen effect adjustment (old)

Step 3 In the pop-up window, perform any of the following operations as required.

Enable 18-bit mode (18bit+)


Select Enable 18-bit mode and click Save to HW.
Enable ClearView
Select Enable ClearView, drag the slider to adjust the value and then click Save to HW.
Enable low latency

www.novastar.tech 76
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

Select Enable sending card low latency and Enable receiving card low latency or either of them, and click
Save to HW. Enabling either of them can reduce the delay by one frame. Enabling both can reduce the latency
by two frames.
Set HDR Parameters (When sending and receiving cards support newer HDR versions)
Choose an HDR mode and configure the associated parameters.
- Screen Peak Brightness: This is the override value for the screen peak brightness. Ensure Override is
checked for it to take effect.
- PQ Mode: If ST2084 is selected, it indicates a 1:1 mapping of the video source's brightness, adjusting the
video’s brightness that exceeds the screen’s maximum to fit. If ST2086 is chosen, it indicates a linear
mapping, adjusting the video source brightness overall while maintaining the content’s brightness ratio.
- MaxCLL: This is the override value for the video source's maximum brightness. Make sure to check
Override for it to be effective.
Set HDR parameters (When sending and receiving cards support older HDR versions)
Select Enable, select HDR10 or HLG from the drop-down box and complete relevant settings.

6.8 Set Image Booster Engine


Applications
Using a professional color analyzer (also called light gun or colorimeter) to correct the cabinet's optical factors (such
as color gamut, brightness, grayscale, and color temperature) to achieve precise brightness control and accurate
color display.

Applicable Products
Applicable to the A8s-N, A10s Plus-N, A10s Pro receiving cards
Color management is also applicable to the A5s Plus and A7s Plus receiving cards

Prerequisites
When collecting screen data, if you select the auto or custom collection method, CA410-VP427, CA410-P427 or
CA410-P427H (use when the brightness exceeds 3000 nits) and the hardware connection must be completed.

Notice
Adjusting the receiving card parameters affects the display effect.

Related Information
When adjusting the effect parameters, it includes the color management, precise grayscale, and 22bit+ functions of
the image booster:
Color Management
With the help of NovaStar's unique color management algorithm, the this function will realign the LED screen's
color gamut to approximate the standard color gamut of BT.709, BT.2020 and D CI-P3, and eventually, the color
gamut is adjusted to be consistent with the video source, eliminating color deviation and reproducing natural
colors.
Precise Grayscale
With the help of professional optical instruments, individually correct the 65,536 levels of grayscale of the driver
IC to fix the display problems at low grayscale conditions, such as brightness spikes, brightness dips, color cast
and mottling and achieve pinpoint accuracy in grayscale control, allowing for a significant improvement in the
quality of LED display images.
22bit+
Harnessing the power of image quality algorithms, the bit depth of low shades of grayscales on the screen is
elevated, resulting in an incredible 64-fold surge in dynamic contrast. This process effectively addresses
common issues such as grayscale loss and contour lines that arise in case of insufficient grayscale on the
screen, allowing for richer grayscale shading and intricate detail presentation for on-screen images.
When you collect the screen data, ensure the colorimeter touches the screen closely. The hardware connection is
illustrated in Figure 6-32.

www.novastar.tech 77
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

Figure 6-32 Colorimeter connection

Operating Procedure
Step 1 On the menu bar, choose User > Advanced Synchronous System User Login. Enter the password and click
Login.

The default password is “admin”.

Step 2 On the main window, click next to the rightmost function icon to open the drop-down list and then click .

Step 3 On the Image Booster screen, click Please refresh and select device located at the top left corner.

Figure 6-33 Image booster

Step 4 In the Device Management dialog box, click Refresh and select a device from the drop-down options.

www.novastar.tech 78
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

Figure 6-34 Device management

Step 5 Select the target cabinets, or toggle on Select Port to select all the cabinets of the Ethernet port and then click OK.

You can also identify, update, or restart the cabinets through the interface where you choose cabinets via Ethernet
port.

Step 6 On the left of the screen, select a frame rate.

Step 7 Set Collection Acceleration and do the following according to the screen data collection method.
 Automatic

a. Set the collection method to Auto.


b. Select a colorimeter model from the drop-down list.
When the hardware connection is normal, the software will automatically establish communication with the
colorimeter after selecting a model.
c. Click Start to automatically collect the screen data through the colorimeter.
 Manual

a. Set the collection method to Manual.


b. Select Color Gamut, manually collect the screen data, and then double-click the color gamut value in the
table and modify it.
c. Select Brightness and then set the brightness before and after calibration.
d. Click Start to make the color gamut and brightness data take effect.
 Custom

a. Set the collection method to Custom.


b. Set the collection indicators.
c. Click Start to automatically collect the screen data through the colorimeter.
Notes
If an image quality file (.nrf/.vglcx) is available, you can click Import to import the image quality data and then
adjust the effect parameter.

Step 8 Under the Effect Settings, set the following parameters and view the effect on the screen.
 Target gamut

Select a target gamut from the drop-down list. To view the target gamut in the color gamut diagram, select
Target Gamut in the middle area of the Correct Cabinets screen.
Do the following to add custom gamut.

www.novastar.tech 79
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

a. Click on the right of the drop-down list to open the adding custom gamut window.

b. Enter a custom gamut name.


c. Select a baseline gamut from the drop-down list.
d. Double-click the cells in the table to change the gamut values or drag the vertex of the black triangle in the
color gamut diagram to modify it.
e. Click OK once you are done.

Select a custom gamut and then click to edit it, or click to delete it.
 Color Temperature

Drag the slider to set the color temperature, or set the value in the entry box.
 Magic Gray

Toggle switch to enable/disable this function. When this is enabled, 22bit+ and Precise Grayscale can be
selected. When the receiving card supports Image Booster 2.1, an Effect Settings button will appear on the
right side of the interface. Clicking this button will allow you to configure the relevant effect parameters in the
dialog box that appears.

www.novastar.tech 80
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

 Dynamic Booster

Toggle switch to enable/disable this function. When this is enabled, drag the slider to adjust the intensity of the
Dynamic Booster, and set the max brightness.
 Brightness

Verify the pre-calibration brightness, post-calibration brightness, and peak brightness, and also check if
brightness overdrive is supported.
Peak Brightness is the max brightness measured by the colorimeter.

Step 9 Click Export to save the configuration into a file.

Step 10 Click Send to send the configuration to the hardware, or click Save to HW to save the configuration to the hardware.

Step 11 If you want to evaluate the color precision, do the following.

1. Click Color Evaluation.

2. On the Evaluate Color Precision screen, select a gamut from the drop-down list and click Start Evaluation.
3. Select Display Demo.
4. Click any of the colors in the table and check their effect on the LED screen. Or, you can set the auto color
switching interval and then click Start Demo to check the effects of all colors on the screen.
− CIE31: The standard value of brightness, Cx and Cy of the color.
− Measured Value Before MGMT: The measured value of brightness, Cx and Cy of the color in the original
color gamut.
− Measured Value: The measured value of brightness, Cx and Cy of the color in the target color gamut.
− DeltaE: The deviation between the measured value and standard value.
5. Deselect Display Demo, click Export Report to save the evaluation result into a file.

6.9 Batch Check Calibration Effects


Applications
Batch check the effects of disabling calibration, brightness calibration and chroma calibration of multiple devices.

Applicable Products
All receiving cards and sending cards

www.novastar.tech 81
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

Prerequisites
None

Related Information
None

Operating Procedure
Step 1 From the menu bar, choose Tools > More > Device Settings.

Figure 6-35 Batch checking calibration effects

Step 2 In the device list, select the device of which you want to check the calibration effects.

Step 3 Select Enable/Disable calibration and click Setting.

Step 4 Click OK to close the prompt box.

Step 5 Select Disable calibration, Brightness calibration or Chroma calibration and check the corresponding display
effects on the LED screen.

www.novastar.tech 82
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

7 Screen Monitoring
7.1 Register Screens with VNNOX Care
7.1.1 Register Online Screens

7.1.1.1 Register via Saving Configuration Files (Recommended)

Applications
Register your online screens with VNNOX Care to perform centralized monitoring of the screen working status from a
remote place.

Applicable Products
All receiving cards and sending cards

Prerequisites
 You have a valid VNNOX Care account.

 The control PC is connected to the Internet.

Related Information
None

Operating Procedure
Step 1 On the menu bar, choose User > Advanced Synchronous System User Login. Enter the password and click
Login.

The default password is “admin”.

Step 2 Click or choose Settings > Screen Configuration from the menu bar.

Step 3 On the pop-up dialog box, select a communication port and choose Configure Screen. Then, click Next.

Figure 7-1 Screen configuration method

Step 4 On the Screen Configuration page, click Save System Configuration File to open the dialog box shown in Figure
7-2.

www.novastar.tech 83
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

Figure 7-2 Saving configuration files

Step 5 Enter your VNNOX Care user name and password, set a screen name and system configuration file name, and select
a server node at the bottom right.

Step 6 After the settings, click Save.

Step 7 After successful saving, close the prompt box.

Notes
During registration, NovaLCT will automatically enable Automatic Refresh and Link to NovaiCare in the
monitoring configuration. If you want to set the refresh period, please see 7.2 View and Configure Monitoring.

7.1.1.2 Register via Function Buttons

Applications
Register your online screens with VNNOX Care, or modify the earlier registration information and then re-register the
screens with VNNOX Care to perform centralized monitoring of the screen working status from a remote place.

Applicable Products
All receiving cards and sending cards

Prerequisites
 You have a valid VNNOX Care account.

 The control PC is connected to the Internet.

Related Information
When multiple screens are connected to the control PC, all these screens will be registered with VNNOX Care.

Operating Procedure

Step 1 Click or choose Tools > Monitoring from the menu bar to open the monitoring page.

You can also right click on the desktop taskbar and select Open MonitorSite to open the monitoring page.

www.novastar.tech 84
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

Figure 7-3 Monitoring

Step 2 Click Configuration to open the MonitorSite – Settings page.

Step 3 On the Refresh Period tab page, select Automatic Refresh and set the refresh period.

Step 4 Set the rereading times. 2 is recommended.

Step 5 Select Link to NovaiCare, click Save and then OK.

Figure 7-4 Monitoring configuration

Step 6 On the desktop taskbar, right click , select Exit and click OK.

Step 7 Click to start the monitoring function again.

www.novastar.tech 85
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

Step 8 Click or choose Settings > Cloud Monitoring from the menu bar.

Step 9 Click Register in VNNOX Care.

Step 10 Click Modify Registration.

Figure 7-5 Registration

Step 11 Select a server node, enter your VNNOX Care user name and password, and set the screen name.

Figure 7-6 Registration information

Step 12 Click Register.

Step 13 After successful registration, click OK to close the prompt box.

7.1.2 Register Offline Screens

7.1.2.1 Register by Using Local Backup Files (Recommended)

Applications
During the process of saving the screen configuration data, save the configuration files to the local PC. When the
control PC can access the Internet normally, use the backup files to register the screens with VNNOX Care.

Applicable Products
All receiving cards and sending cards

www.novastar.tech 86
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

Prerequisites
You have a valid VNNOX Care account.

Related Information
None

Operating Procedure
Step 1 On the menu bar, choose User > Advanced Synchronous System User Login. Enter the password and click
Login.

The default password is “admin”.

Step 2 Click or choose Settings > Screen Configuration from the menu bar.

Step 3 On the pop-up dialog box, select a communication port and choose Configure Screen. Then, click Next.

Figure 7-7 Screen configuration method

Step 4 On the Screen Configuration page, click Save.

Step 5 After successful saving, click OK to save the backup file to the local computer.

This step is related with the configuration of the save function. See 11.2 Set Main Window Starting Position

Applications
Set the coordinates of the top-left corner of the main window of NovaLCT on the desktop, and make the window
display in the specified position when the software is started.

Applicable Products
N/A

Prerequisites
None

Related Information
None

Operating Procedure
Step 1 On the menu bar, choose Settings > The Main Window Starting Position.

www.novastar.tech 87
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

Figure 7-8 Setting starting position coordinates

Step 2 Set the coordinates of the top-left corner of the main window on the desktop, and click OK.

After the settings are done, the main window moves to the specified position. When next time NovaLCT is started, the
main window will be displayed in the target position.
Configure the Save Function.

Step 3 After successful saving, click Close.

For devices with the same SN, NovaLCT uses the new file to overwrite the old file.

Figure 7-9 Saved successfully

Step 4 When the control PC can access the Internet normally, click on the main window and then click Local
Backup Files to open the dialog box shown in Figure 7-10.

www.novastar.tech 88
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

Figure 7-10 Local backup files

Step 5 Enter a remark.

The remark will be the name of the successfully bound screen. If the remark is empty, the device SN will be the
screen name.

Step 6 Select the backup file records of one or multiple devices and click Bind.

Step 7 Enter your VNNOX Care user name and password, select a server node and click OK.

After successful binding, the Binding Status of the corresponding device in the Local Backup Files dialog box
becomes Bound.

Figure 7-11 Binding to VNNOX Care

Related Operations

Both in the logged in and not logged in statuses, you can click and then Local Backup Files to open its
dialog box and check the device binding status and delete configuration files.

7.1.2.2 Register by Using Screen Monitoring Data

Applications
Export the configuration file of an offline screen. When the control PC can access the Internet normally, import the
exported configuration file to VNNOX Care to complete screen registration.

www.novastar.tech 89
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

Applicable Products
All receiving cards and sending cards

Prerequisites
You have a valid VNNOX Care account.

Related Information
None

Operating Procedure
Step 1 On the menu bar, choose User > Advanced Synchronous System User Login. Enter the password and click
Login.

The default password is “admin”.

Step 2 Click or choose Settings > Screen Configuration from the menu bar.

Step 3 On the pop-up dialog box, select a communication port and choose Configure Screen. Then, click Next.

Figure 7-12 Screen configuration method

Step 4 Choose a communication port.

Step 5 Select Configure Screen and click Next.

Step 6 On the Screen Configuration page, click Export Screen Monitoring Data to open the dialog box shown in Figure 7-
13.

Figure 7-13 Exporting screen monitoring data

www.novastar.tech 90
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

Step 7 Set a file name, click to select a location and click Save.

Step 8 After successful saving, click OK to close the prompt box.

Step 9 When the control PC can access the Internet normally, log in to VNNOX Care.

Step 10 Go to My Services > Screen Management to enter the screen management page.

Step 11 Click Add Screen, select the exported screen monitoring data file and click Upload.

7.2 View and Configure Monitoring


Applications
View the monitoring information and configure the monitoring parameters to monitor the statuses of sending cards,
receiving cards, receiving card temperatures, monitoring devices, as well as humidity, smoke, fans, power supplies,
cables, cabinet doors, modules, iCare within the control system, in order to detect abnormalities and handle them in
time.

Applicable Products
 Use monitoring card for monitoring: Applicable to the MON300 monitoring card. This card works with the MRV320
and MRV560 receiving cards.
 Use smart modules for monitoring: Applicable to the A4, A4s, A5, A5s, A5s Plus, A7, A7s, A7s Plus, A8, A8s, A9s,
A10s Plus, XC200, XC100 and B4s receiving cards. The smart module monitoring function is a customized
function of the receiving cards.
 Use hub products for monitoring: Applicable to the A4, A4s, A5, A5s, A7, A7s, A8, A8s, A9s, A10s Plus, XC200
and XC100 receiving cards. Using hub product for monitoring is an optional function of the receiving cards.

Prerequisites
 If you want to use the monitoring function of monitoring card, a monitoring card should be used between the
module and receiving card.
 If you want to use the email service, the SMTP server address and port must be known in advance.

Related Information
When the monitoring card is used, hub monitoring and smart module cannot be used. Hub monitoring and smart
module can be used simultaneously.

Operating Procedure

Step 1 Click or choose Tools > Monitoring from the menu bar to open the monitoring page.

You can also right click on the desktop taskbar and select Open MonitorSite to open the monitoring page.

www.novastar.tech 91
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

Figure 7-14 Monitoring

Notes
 Click Monitoring Refresh to manually refresh the monitoring information.

 On the desktop taskbar, right click and select Reload Screen to refresh the receiving card topology
diagram.

Step 2 Click the monitoring item on the left or at the bottom of the page to view the detailed monitoring information.

Step 3 Click Configuration to set the monitoring parameters.

Refresh Period

Set the necessary items as follows and click Save to save the settings.

www.novastar.tech 92
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

− Select Automatic Refresh to set the refresh period. The monitoring information will be refreshed based on
the set time period. If the screen is registered with iCare, this item must be selected.
− Set the reread times when the reading of the monitoring information from the receiving card fails.
− Select Link to NovaiCare to enable iCare to get the monitoring information.
Hardware Settings

Set the necessary items as follows and click Save to save the settings.
− Select Connect to Monitoring Card and set the monitoring items. Click Setting to set the number of
monitoring cards connected to each cabinet. The number is 0 or 1.
− Select Connect to HUB Monitoring and set the monitoring items.
− Select Connect to Smart Module and set the monitoring items. If the TBS 614 Chip is selected, you can
click Module Monitoring in the monitoring interface to view and configure the information related to the
module monitoring.
− Select Connect to HUB Monitoring and Connect to Smart Module, and then set the monitoring items.
Alarm

Set the alarm thresholds for temperature, fan rotating speed and voltage. When the threshold value is exceeded,
faults or alarms will be displayed. After the configuration is done, click Save to save the settings.

www.novastar.tech 93
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

Monitoring Control

Set the rules for automatic control of smoke, temperature and dual backup power supply. If the control type is
set to smoke, a multifunction card must be configured in advance. After the settings are done, click OK.
Email

Select Enable Email Notification. Set the necessary items as follows and click Save to save the settings.
− Set the condition for sending an email notification, namely how many times the same fault or alarm occurs
consecutively.
− Select Enable System Recovery Notification to send email notification when the fault or alarm recovers.
− Select Enable Sending System Report Email and click Send system report email regularly to set the
email sending period and time.
− Click Modify Sender to change the email service related settings.
− Add, edit or delete the recipients.
− Set where the email is sent from.
Email Log

www.novastar.tech 94
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

View or delete the email log. Enable the email notification function before log operations.

7.3 Configure Module Monitoring


Applications
Configure the module monitoring parameters to monitor the module's temperature, voltage, and bit error.

Applicable Products
All receiving cards.

Prerequisites
 The module is equipped with a TBS 614 chip.
 You have selected Connect to Smart Module in the monitoring configuration, and along with the TBS 614 Chip.

 You have completed the Flash Arrangement. For more details, please refer to 5.8 Set Performance Parameters

Related Information
None

Operating Procedure

Step 1 Click or choose Tools > Monitoring from the menu bar to open the monitoring page.

You can also right-click on the desktop taskbar and select Open MonitorSite to open the monitoring page.

www.novastar.tech 95
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

Figure 7-15 Monitoring

Step 2 Click Module Monitoring.

Step 3 On the Module Info dialog box, select Temperature, Voltage or Bit Error to view the corresponding monitoring
information. Click on the text link of the monitor result to view the details.

Related Operations:

 The monitoring information will be refreshed once when you select the items to be monitored. To refresh again,
click Manual.

 Screen Display: Click Normal display in the Action column to switch to Screen display, which will show the
test pattern in the load area of the corresponding receiving card.

 Clear Errors: Click Clear Errors in the respective column to reset the errors of the corresponding receiving card.
To reset the errors of all receiving cards in the list, click Clear in the top right corner of the interface.

www.novastar.tech 96
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

Figure 7-16 Module information

Step 4 (Optional) Select Auto Refresh and set the refresh interval.

Step 5 Click Thresholds.

Step 6 On the pop-up dialog box, set the alarm thresholds for temperature, voltage, and bit error. Clicking on Celsius or
Fahrenheit allows you to switch temperature units.

Figure 7-17 Thresholds

Step 7 Click Save once you are done.

www.novastar.tech 97
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

8 Screen Management
8.1 Multi-function Card Management
Applications
Configure the multifunction card, and perform power management, monitoring data viewing, peripheral settings,
program loading and audio management.

Applicable Products
The MFN300 multifunction card

Prerequisites
Hardware connections for the multifunction card are done.

Related Information
None

Operating Procedure

Step 1 Click or choose Settings > Multi-function Card from the menu bar.

Figure 8-1 Multifunction card management

Step 2 Click Add and select the connection type for the multifunction card.
 Serial Port Connection: Select this option when the serial port of the multifunction card is connected to the USB
port of the PC.
 Ethernet Port Connection: Select this option when the Ethernet port of the multifunction card is connected to that
of the sending card or receiving card.
You can also remove, refresh or rename the added connections.

www.novastar.tech 98
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

For serial port connection, you can perform the following operations:
 Modify Serial Port: Change the current serial port to the one that is not configured for the multifunction card.

 Replace Serial Port: Replace the current serial port with the one that is connected with the multifunction card.

Step 3 For serial port connection, choose a communication port and click OK.

For Ethernet port connection, choose a communication port and set other parameters as shown in Figure 8-2, and
then click OK.

Figure 8-2 Adding multifunction cards

Figure 8-3 shows the user interface of an Ethernet port connection that is added successfully. The following
procedure takes Ethernet port connection as an example to illustrate the function.

Figure 8-3 Ethernet port connection

Step 4 Use any of the following functions as needed.

Power Management

www.novastar.tech 99
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

− Read: Read the time from the multifunction card.


− Set: Set the multifunction card time to the PC time.
− Set Notes: Write notes for the power supplies.
− Start Delay: Set the delay time for powering on the multifunction card.
− Refresh: Read back the multifunction card information.
− Start All: Start all power supplies.
− Emergency Stop: Stop all power supplies. When the emergency stop operation is executed, automatic
control is invalid.
− Manual: Start or stop the power supplies manually.
− Automatic Control: Set the auto start and stop time for the power supplies.
− Software Control: Set the power control schedule. Click Edit to customize the power control list. Click View
Log to view the power control log.
− Advanced: Set the time for the automatic time synchronization between the multifunction card and PC.
Monitoring Data

www.novastar.tech 100
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

View the monitoring data of both multifunction card itself and its connected monitoring card.
Peripheral Device

Add the peripheral devices connected to the multifunction card, including the light sensors and external 3D
emitters.
Load Program

www.novastar.tech 101
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

Click Refresh to view the multifunction card model, FPGA version and FPGA note.
Type “admin” to access the options for program loading.
a. Select Load program for selected Multi-function Card or Load all programs for Multi-function Card.
b. Click Browse to select the program package.
c. Click Change to load the selected program.
d. Click Exit to hide the program loading options.

Audio Management

www.novastar.tech 102
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

Set the audio channel connected to the multifunction card, including the independent channel and HDMI
channel.

8.2 Multiple-screen Management


Note
The settings for multiple-screen management are only effective on your computer's NovaLCT. To apply them on
other computers, you will need to adjust the corresponding settings accordingly.

Applications
Combine multiple screens into a combined screen, allowing for easier brightness adjustment, screen calibration and
monitoring configuration, and higher working efficiency.

Applicable Products
All receiving cards and sending cards

Prerequisites
None

Related Information
The combined screen supports both auto and manual brightness adjustment.

Operating Procedure
Step 1 On the menu bar, choose User > Advanced Synchronous System User Login. Enter the password and click OK.

The default password is “admin”.

Step 2 Choose Settings > Multiple-screen Management.

www.novastar.tech 103
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

Figure 8-4 Multi-screen management

Step 3 Set the number of combined screens and click Configuration.

Step 4 Set the combined screen name and number of screens in the combined screen, and then click Configuration.

Figure 8-5 Configuration of combined screen

Step 5 Right click the first screen to pop up the window as shown in Figure 8-6. Choose a communication port and its
associated screen.

www.novastar.tech 104
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

Figure 8-6 Associated screen

Step 6 Do the same for other screens of the combined screen.

Step 7 Drag the screen to snap it to other screens.

Figure 8-7 Adjusting screen position

Step 8 After the settings are done, click OK.

8.3 Prestore Screen


Applications
Set the picture displayed on the screen during startup process, or displayed when the Ethernet cable is disconnected
or there is no video signal.

Applicable Products
All receiving cards and sending cards

Prerequisites
A picture in BMP, JPG or PNG format is prepared.

Related Information
None
www.novastar.tech 105
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

Operating Procedure
Step 1 On the menu bar, choose Settings > Prestore Screen.

Figure 8-8 Prestore picture settings

Step 2 Choose a communication port.

Step 3 Set a prestore picture.

1. Click Browse to select a picture.


2. Set the screen display effect and click Test Effect to view the actual effect.
− Screen Effect: The selected picture will be stretched, tiled or centered to fit the screen.
− Single Cabinet Effect: The selected picture will be stretched, tiled or centered to fit each cabinet of the
screen.
Select Extended Screen to display the picture on the extended screen.
3. Click Save to HW to save the prestore picture to the hardware.
4. Click Check Stored Picture to view the current prestore picture.

Step 4 Set the picture displayed during startup process, or displayed when the Ethernet cable is disconnected or there is no
video signal.

1. Select Enable in the Start-up Picture area and set how long the prestore picture is displayed for during the
startup process.
2. Set whether the screen is black, or displays the last frame image or prestore picture when the Ethernet cable is
disconnected.
3. Set whether the screen is black, or displays the last frame image or prestore picture when there is no video
signal.
4. After the settings are done, click Send to send the configuration information to the hardware.
5. Click Save to HW to save the configuration information to the hardware.

8.4 Receiving Card Relay


Applications
Set the receiving card relay status to manually connect or disconnect the circuit or let the circuit automatically
connect or disconnect, and reset the receiving card running time.

www.novastar.tech 106
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

Applicable Products
 Setting the receiving card relay status: Applicable to the MRV350 receiving card

 Resetting the receiving card running time: Applicable to all receiving cards

Prerequisites
None

Related Information
When the relay is closed, the circuit is connected. When the relay is released, the circuit is disconnected.
The running time is accumulated as the receiving card works, and will not be reset after the receiving card is powered
off.

Operating Procedure
Step 1 On the menu bar, choose User > Advanced Synchronous System User Login. Enter the password and click
Login.

The default password is “admin”.

Step 2 Choose Settings > Receiving Card Relay.

Figure 8-9 Setting receiving card relay

Step 3 Choose a communication port and perform the following operations as required.

Set receiving card relay


− Select Disconnected and click Send to disconnect the circuit.
− Select Connected and click Send to connect the circuit.
− Select Automatic and set the threshold temperatures for both connecting and disconnecting the relay, and
then click Send.
Reset receiving card running time
Click Timing Resetting to record the receiving card running time from 0.

www.novastar.tech 107
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

8.5 Screen Control


Applications
Set the screen display status. Use the test pattern to perform the screen aging test and detect problems. Control the
cabinet LCD backlight status.

Applicable Products
 Flipping: Applicable to the MCTRL660 PRO sending card

 Other functions: Applicable to all receiving cards and sending cards

Prerequisites
None

Related Information
None

Operating Procedure

Step 1 Click or choose Tools > Screen Control from the menu bar.

Figure 8-10 Screen control

Step 2 Perform any of the following operations as required.

Set screen display


Select Black Out, Freeze or Normal. When Freeze is selected, the screen always displays the current image.
Select test pattern
Select a test pattern from the drop-down list and click Send. The receiving card will display the selected test
pattern on the screen.
Set LCD backlight status
Select or deselect Turn off cabinet LCD and click Send.
Set receiving card indicator
Select or deselect Turn off Rv Card Indicator and click Send.

Step 3 When the MCTRL660 PRO is connected, select a flipping option for the image of the Ethernet port. The options
include Disable, Left-Right, or Top-Bottom. If other devices are connected, skip this step.

Step 4 Click Save once you are done.

www.novastar.tech 108
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

8.6 Controller Cabinet Configuration File Import


Applications
Save the receiving card configuration files to the sending card, so as to send the configuration files to the receiving
card on site by using the configuration file import function of the sending card.

Applicable Products
 Importing cabinet configuration files: Applicable to the device-level sending cards

 Renaming device: Applicable to the NovaPro HD, VX2, VX4, VX4S, VX5s, VX6s, K4, K4S, K6s, VD43, VX2U,
VX4U, K4U, K2U, VX2S, CVT4K-S, MCTRL4K, K16, H9, V1260, NovaPro UHD Jr, MCTRL1600, MCTRL R5,
MCTRL660 PRO and E8000

Prerequisites
The receiving card configuration files in .rcfgx or .rcfg format are ready. The cabinet must be a regular cabinet, and
cannot be in triple or quadruple strip output mode.

Related Information
None

Operating Procedure
Step 1 On the menu bar, choose Tools > Controller Cabinet Configuration File Import.

Figure 8-11 Importing cabinet configuration files

Step 2 Choose a communication port.

Step 3 Click Add Configuration File, select a configuration file, and click Open.

You can add configuration files for multiple receiving cards as needed. You can also delete and rename the
configuration file.

Step 4 If you need to specify one or multiple sending cards, click Advanced Configuration. Select the desired sending
cards in the displayed dialog box, and click OK. If you want to save the configuration files to all the connected
sending cards, skip this step.

www.novastar.tech 109
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

Figure 8-12 Advanced configuration

Step 5 After the settings are done, click Save the Change to HW to save the configuration files to the sending cards.

Step 6 After the files are saved successfully, click OK.

Step 7 If the renaming function is supported by device, you can rename the sending card as shown in Figure 8-13. If not
supported, skip this step.

Figure 8-13 Renaming sending cards

1. Select Enable Naming.


2. Choose a sending card and click Rename.
3. Enter the new name that contains only letters, and click OK.
4. Click Save to HW.

8.7 Module ID Settings


Applications
Set ID for the module containing a flash memory.

Applicable Products
The receiving cards that support module Flash or smart module

www.novastar.tech 110
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

Prerequisites
The Flash arrangement is completed as described in 5.8 Set Performance Parameters.

Related Information
Some modules do not support ID settings. For details, please contact NovaStar.

Operating Procedure
Step 1 On the menu bar, choose User > Advanced Synchronous System User Login. Enter the password and click
Login.

The default password is “admin”.

Step 2 Choose Tools > Module ID setting.

Step 3 Click Refresh to view the module IDs.

Figure 8-14 Viewing module IDs

Step 4 Type “admin” to access the ID setting pane.

www.novastar.tech 111
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

Figure 8-15 Setting module ID (regular screen)

Figure 8-16 Setting module ID (complex screen)

Step 5 Select the ID generation method and then click Generate to set IDs for all the modules. When manually setting the ID,
for regular screens, double click a single module and set its ID in the displayed dialog box, and then click OK; for
complex screens, double-click the cell of ID column, set the ID and click any other place of the interface.
 Prefix: Set the prefix of the module ID.

 Sort: Select the sorting type for the module IDs.

− Z-shape: Generate module IDs from left to right for all the rows from top to bottom. The ID format is
“receiving card number-module number”.
− N-shape: Generate module IDs from bottom to top for all the columns from left to right. The ID format is
“receiving card number-module number”.

www.novastar.tech 112
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

− Inverse Z-shape: Generate module IDs from right to left for all the rows from top to bottom. The ID format
is “receiving card number-module number”.
− Inverse N-shape: Generate module IDs from top to bottom for all the columns from left to right. The ID
format is “receiving card number-module number”.
− No.: The ID format is “receiving card number-Flash number”.
− Ascending: The module IDs are in ascending order.
− Descending: The module IDs are in descending order.
 By cabinet: Generate the IDs for all modules based on cabinets by Z type or N type, or number the modules by
“sending card number-output port number-receiving card number-Flash number”.

Step 6 After the settings are done, click Save to HW to save the configuration information to the hardware.

8.8 Set Device Communication Parameters


Applications
Configure the device's IP address and identify the device.

Applicable Products
The MCTRL700 Pro sending card

Prerequisites
None

Related Information
None.

Operating Procedure
Step 1 On the menu bar, choose User > Advanced Synchronous System User Login. Enter the password and click
Login.

The default password is “admin”.

Step 2 Choose Tools > Device Communication

Figure 8-17 Device communication

Step 3 Do the following as required.

Set device IP
Click Set IP and configure the device's IP address..
Identify device
After using the locate feature, the red light on the target device will flash, helping you easily spot it.
- To identify multiple devices: Select Identify Device and then choose the numbers of the devices you want
to find.
- To identify a single device: Select Identify for the specific device you want to find.

www.novastar.tech 113
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

8.9 Sending Card Relay Settings


Applications
Set the status of the sending card relay to turn on or off the power of the receiving card.

Applicable Products
The KT8 sending card

Prerequisites
None

Related Information
When the relay is closed, the circuit is connected. When the relay is released, the circuit is disconnected.

Operating Procedure
Step 1 On the menu bar, choose User > Advanced Synchronous System User Login. Enter the password and click
Login.

The default password is “admin”.

Step 2 Choose Tools > More > Sending Card Relay.

Figure 8-18 Sending card relay

Step 3 Choose a communication port and a sending card.

Note: When the sending cards are cascaded, multiple sending cards are displayed in the list.

Step 4 Check the relay status and perform the following operations as required.
 Click Start to connect the circuit.

 Click Stop to disconnect the circuit.

8.10 Optical Port Settings


Applications
When automatic pairing between two CVT10 devices fails, set the optical ports of those devices respectively to make
pairing succeed.

Applicable Products
The CVT10 fiber converter

Prerequisites
None

www.novastar.tech 114
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

Related Information
When the sending card has no optical ports, two CVT10 devices must be used for photoelectric conversion. The two
CVT10 devices can pair automatically. After successful pairing, they can transmit data normally.

Figure 8-19 Photoelectric conversion between two CVT10 devices

Operating Procedure
Step 1 On the menu bar, choose User > Advanced Synchronous System User Login. Enter the password and click
Login.

The default password is “admin”.

Step 2 Choose Tools > More > Optical Port Settings.

Figure 8-20 Optical port settings

Step 3 Choose a communication port.

Step 4 Click Enable.

www.novastar.tech 115
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

9 Screen Maintenance
9.1 Firmware Program Update
Applications
Check the device firmware program version, and update the program.

Applicable Products
All receiving cards and sending cards

Prerequisites
The program update package is prepared.

Related Information
In the Screen Configuration interface, click Program Update. In the popup window, you can either click Cloud
Update to match and install the firmware package automatically, or select and load a package manually. Alternatively,
you can click Local Update to load and install the firmware package from your computer.

Figure 9-1 Program update

Operating Procedure
Step 1 On the menu bar, choose User > Advanced Synchronous System User Login. Enter the password and click
Login.

The default password is "admin".

Step 2 Click , or type "admin" or "123456" to open the program loading window as shown in Figure 9-2.

www.novastar.tech 116
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

Figure 9-2 Program loading

Step 3 Choose a communication port.

If you need to reconnect the sending card, click Reconnect.

Step 4 Specify the viewing range and click Refresh to view the current program version of the hardware.
 Refresh All: View the program versions of all the sending cards and receiving cards.

 Refresh Specified: View the program versions of the specified sending cards and receiving cards.

If the module has an MCU, select Refresh Module MCU to view the MCU version.

Figure 9-3 Viewing program version

Step 5 Click Browse, select a program package, and click OK. If you select an integrated firmware package for the receiving
card (which includes firmware for multiple receiving cards), follow these steps:

In the Update Program interface, select the appropriate driver IC and decoding method based on your actual
requirements, then either match the package file automatically or choose it manually, and click Update.

- Auto match: Select Auto Match, and the software will automatically select the appropriate package file based on
the receiving card model, and the specified driver IC and decoding method.

www.novastar.tech 117
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

- Manual selection: Unselect the Auto Match, and manually choose the required package file from the list.

Step 6 Click Advanced, select the items to be updated, and click OK.

Step 7 Click Update.

Step 8 Set to update the programs of all receiving cards or the specified receiving card, and then click OK.

Figure 9-4 Selecting send mode

Step 9 After the programs are updated successfully, click OK.

Note
If the receiving card supports program readback, click Read-back of receiving card program to save the
receiving card program to a specified location.

9.2 LED Error Detection


Applications
Detect the damaged LED lights and locate them on the screen.
www.novastar.tech 118
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

Applicable Products
 Use monitoring card for Led error detection: Applicable to the MRV320 and MRV560 receiving cards

 Use smart module for Led error detection: Applicable to the A4, A4s, A5, A5s, A5s Plus, A7, A7s, A7s Plus, A8,
A8s, A9s, A10s Plus, XC200, XC100 and B4s receiving cards. The smart module Led error detection function is a
customized function of the receiving cards.

Prerequisites
 The module driver chip must be support LED error detection.

 If you want to use the Led error detection function of the monitoring card, the module driver chip must support
1/16 scan or below, and the MON300 monitoring card is required between the connection of module and the
MRV320 or MRV560.

Related Information
None

Operating Procedure
Step 1 On the menu bar, choose Tools > Led Error Detection.

Figure 9-5 Led error detection

Step 2 Choose a communication port.

Step 3 Set Led error detection parameters.


 Detection Type: The detection types supported by the driver chip

 Threshold Voltage: The threshold voltage of the driver chip, which can be set based on the information provided
by the screen manufacturer
 Current Gain: Select whether to enable the current gain function. Click Change Setting to adjust the current gain.

 Bi-Color LED Error: Select whether to detect only the red and green LED lights.

Step 4 Click Conduct led error detection for full screen, or select a cabinet on the screen topological diagram and click
Led error detection selection.

Step 5 After the detection is done, click OK.

www.novastar.tech 119
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

Figure 9-6 Result of the Led error detection for the whole screen

The number displayed on the topological diagram indicates the number of the faulty LED lights. Hover the mouse
over the topological diagram to view the detailed Led error detection information.

Step 6 Double click a cabinet in the topological diagram to access the interface shown in Figure 9-7.

Figure 9-7 Result of the Led error detection for all the modules

Step 7 Select a red module, and select Red A, Green, Blue or Red B (virtual red) on the right to view the faulty LED lights
which are shown in black.

9.3 Reset Run Time


Applications
Reset the receiving card run time displayed on each cabinet LCD.

www.novastar.tech 120
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

Applicable Products
All receiving cards

Prerequisites
None

Related Information
The run time is stored in the receiving card and displayed on the cabinet LCD.

Operating Procedure
Step 1 On the menu bar, choose Tools > More > Reset Run Time.

Figure 9-8 Resetting run time

Step 2 Choose a communication port and a screen.

Step 3 Click Reset.

9.4 Bit Error Detection


Applications
Check the bit error rate information and signal-to-noise ratio of the receiving card's Ethernet port communication.

Applicable Products
 Error rate detection: Applicable to all receiving cards.
 Ethernet disconnection count: Applicable to A10s Pro.
 Signal-to-noise ratio detection: Applicable to A10s Pro.

Prerequisites
None

Related Information
None

Operating Procedure
Step 1 On the menu bar, choose Tools > More > Bit Error Detection.

Step 2 Navigate to the Error Rate Info tab and then click Manually as shown in Figure 9-9.

www.novastar.tech 121
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

Figure 9-9 Bit error detection

Step 3 If the communication is abnormal, perform any of the following operations as required. If the communication is normal,
skip this step.

View error details


Click the link in the Error Details column and view the detailed error information in the displayed dialog box.
Locate display area
Click Locate to view the display area on the screen.
Clear errors
Click Clear Errors to reset the error quantity to 0.

Step 4 If the receiving card model is A10s Pro, navigate to the Signal-to-Noise Ratio tab, click Manually, and then check
the detection results. If you're using a different receiving card model, you can skip this step.

Step 5 (Optional) Select Auto Refresh and set the refreshing period.

9.5 View Hardware Information


Applications
Set the current time of the hardware, and view the sending card SNs and hardware program version information.

Applicable Products
All receiving cards and sending cards

Prerequisites
None

Related Information
Currently only hour, minute and second can be set, but the date cannot be set.

Operating Procedure
Step 1 On the menu bar, choose Settings > Hardware Information.

www.novastar.tech 122
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

Figure 9-10 Hardware information

Step 2 Choose a communication port.

After a communication port is selected, the current hardware time will be refreshed automatically. You can also click
Read to manually update the hardware time.

Step 3 If you want to set the current time of the sending card to that of the computer, click Set; otherwise, skip this step.

Step 4 Click Reread to view the sending card SNs.

Step 5 Specify the refreshing range, and click Refresh to view the current program version of the hardware.
 Refresh All: View the program versions of all sending cards and receiving cards.

 Refresh Specified: View the program versions of the specified sending cards and receiving cards.

If the module has an MCU, select Refresh Module MCU to view the MCU version.

www.novastar.tech 123
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

Figure 9-11 Viewing program version

9.6 Set Cabinet Dehumidification


Applications
Dehumidify the cabinet that has been stored for a prolonged period or left unpowered for an extended duration.

Applicable Products
All receiving cards and the sending card MCTRL4K

Prerequisites
None

Related Information
None

Operating Procedure
Step 1 On the menu bar, choose User > Advanced Synchronous System User Login. Enter the password and click
Login.

The default password is “admin”.

Step 2 Select Settings > Cabinet Dehumidification.

Step 3 Select a communication port and click Next.

www.novastar.tech 124
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

Figure 9-12 Select the communication port

Step 4 Toggle on the Cabinet Dehumidification switch ( )

Figure 9-13 Cabinet dehumidification

Step 5 Click Edit. In the pop-up dialog box, set the dehumidification strategy and click OK.

Figure 9-14 Set dehumidification strategy

 Brightness: The corresponding screen brightness when the dehumidification duration reaches a certain range.

 Duration: Duration for dehumidification.

www.novastar.tech 125
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

 Power-off Time: The duration of the sending card power-off time.

 Display Content: The displayed content on the screen during the dehumidification.

− White Screen: Display a white screen.


− From Input: Display the current video source.

Step 6 Select a dehumidification strategy and then select an execution mode.


 On next power-on: If Based on sending card power-off time is not selected, the screen will enter the
dehumidification mode upon the next power-on, based on the user-selected strategy. If Based on sending card
power-off time is selected, the screen will automatically match the dehumidification strategy based on the
duration of the sending card power-off time, and enter the dehumidification mode upon the next power-on.
 On power-on: If Based on sending card power-off time is not selected, the screen will enter the
dehumidification mode upon each power-on, based on the user-selected strategy. If Based on sending card
power-off time is selected, the screen will automatically match the dehumidification strategy based on the
duration of the sending card power-off time, and enter the dehumidification mode upon each power-on.
 Execute now: Start dehumidification now.

Step 7 Click OK once you are done.

www.novastar.tech 126
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

10 Plug-in
10.1 Test Tool
Applications
Show test patterns on the screen to assess the screen's functionality and pinpoint any potential issues.

Applicable Products
All receiving cards and sending cards

Prerequisites
When the display window is large, it is recommended you use an extended display to display the test pattern for
easier operation of the software.

Related Information
None

Operating Procedure

Note
You can choose to use either the old or new version of Test Tool via Settings > Test Tool Settings in the menu
bar.

Click or choose Plug-in > Test Tool from the menu bar to open Test Tool.

 For more detailed instructions on the new version of Test Tool, please refer to Test Tool User Manual.

 For the old version of Test Tool, you could adjust the test pattern size based on the screen size, as well as
modify the test pattern position, and show/hide the test pattern in the Window tab. Additionally, you could
customize the test pattern further in the Pure Color, Gradual Change, Grid, and Orientation tabs.

10.2 Calculator
Applications
Open the Windows calculator for users to do the necessary calculations.

Applicable Products
N/A

Prerequisites
None

Related Information
None

Operating Procedure
On the menu bar, choose Plug-in > Calculator to open the Windows calculator.

www.novastar.tech 127
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

10.3 External Program


Applications
Add the shortcut icons for the commonly-used programs to NovaLCT user interface.

Applicable Products
N/A

Prerequisites
None

Related Information
None

Operating Procedure
Step 1 On the menu bar, choose Plug-in > External Program.

Figure 10-1 External program

Step 2 Click .

Figure 10-2 Adding external programs

Step 3 Select the program path and enter the command line parameter as required, and then click OK.

If the external program is successfully added, the shortcut icon of the program will be displayed in Figure 10-1.

Notes

Select an external program icon and click to remove the program.

Step 4 Click OK.

www.novastar.tech 128
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

11 Software Settings
11.1 Configuration Information Management
Applications
Import and export the NovaLCT configuration files for quick configuration in NovaLCT..

Applicable Products
N/A

Prerequisites
None

Related Information
None

Operating Procedure
Step 1 On the menu bar, choose Settings > Configure Information Management.

Figure 11-1 Configuration file management

Step 2 Do the following as required.

Import Configuration File


Click Import Configuration, browse for the configuration file (.zip), and click Open.
Export Configuration File
Click Export Configuration, choose a save path, enter the file name, and then click Save.

11.2 Set Main Window Starting Position


Applications
Set the coordinates of the top-left corner of the main window of NovaLCT on the desktop, and make the window
display in the specified position when the software is started.

Applicable Products
N/A

Prerequisites
None

Related Information
None

www.novastar.tech 129
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

Operating Procedure
Step 1 On the menu bar, choose Settings > The Main Window Starting Position.

Figure 11-2 Setting starting position coordinates

Step 2 Set the coordinates of the top-left corner of the main window on the desktop, and click OK.

After the settings are done, the main window moves to the specified position. When next time NovaLCT is started, the
main window will be displayed in the target position.

11.3 Configure the Save Function


Applications
Configure the Save function that is in the Screen Configuration dialog box.

Applicable Products
All receiving cards and sending cards

Prerequisites
None

Related Information
None

Operating Procedure
Step 1 On the menu bar, choose Settings > Screen Configuration Backup Settings.

Step 2 Select an option and click Save.

Figure 11-3 Save to HW configuration

www.novastar.tech 130
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

11.4 Cloud Server Configuration


Applications
Configure the cloud server address to VNNOX Care or a custom domain name. The custom domain can only be used
to restore the configuration file from the cloud when setting up the screen and does not support other cloud-based
functions.

Applicable Products
All receiving cards and sending cards.

Prerequisites
To configure the server address as a custom domain name, you need to have an available domain.

Related Information
None

Operating Procedure
Step 1 On the menu bar, choose Settings > Server Configuration.

Figure 11-4 Server configuration

Step 2 Select VNNOX Care or select Custom domain name and enter you domain name.

Step 3 Click OK once you are done.

Step 4 Restart the NovaLCT for the change to take effect.

11.5 Test Tool Settings


Applications
You can choose to use either the old or new version of Test Tool.

Applicable Products
All receiving cards and sending cards.

Prerequisites
None

Related Information
The Test Tool is for displaying test patterns on the screen.

www.novastar.tech 131
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

Operating Procedure
Step 1 On the menu bar, choose Settings > Test Tool Settings.

Figure 11-5 Test Tool settings

Step 2 Select a version for the Test Tool and click Save.

11.6 Change UI Language


Applications
Change the UI language for NovaLCT.

Applicable Products
N/A

Prerequisites
None

Related Information
NovaLCT supports Deutsch, English, Spanish, French, Japanese, Korean, Portuguese, Russian, Thai language,
Traditional Chinese and Simplified Chinese.

Operating Procedure
On the menu bar, choose Language and select the target language from the sub-menu.

11.7 Obtain Help Information


Applications
Check the user manuals, update log and software information of the current version of NovaLCT, and contact online
customer service.

Applicable Products
N/A

Prerequisites
None

Related Information
None

www.novastar.tech 132
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

Operating Procedure
Choose Help from the menu bar and do the corresponding operations below as needed.
Check User Manuals
Choose User Documents and select the desired user manual.
View Update Log
Choose Update Log to view the update log in the displayed dialog box.
View Software Information
Choose About to view the software version and copyright information in the displayed dialog box. If needed,
click the link to visit the official website of NovaStar.
Contact online customer service
Choose Online Support. On the displayed page, chat with the customer service online.

11.8 Update Software


Applications
When the Internet is available, download the NovaLCT update package from the cloud and install it.

Applicable Products
N/A

Prerequisites
The control computer is connected to the Internet.

Related Information
None

Operating Procedure
Step 1 From the menu bar, choose Help > Online Update.

Notes
If NovaLCT is not up to date, after NovaLCT is opened, an “Online Update” dialog will be displayed.
If there is an available new version, an icon is displayed in front of the Online Update menu name.

Figure 11-6 Online update

Step 2 Click OK.


www.novastar.tech 133
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

Step 3 Click Get Update.

Step 4 After the update package is downloaded, click Install Update and wait for it to complete.

Figure 11-7 Installing update

11.9 Export Log


Applications
Export the logs of NovaLCT.

Applicable Products
N/A

Prerequisites
None

Related Information
None

Operating Procedure
On the menu bar, choose Help > Export Log. On the pop-up window, choose a save path and click OK.

www.novastar.tech 134
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

12 Troubleshooting
12.1 Installation Problems
12.1.1 Failed to install NovaLCT of earlier versions

Problem
The installation of NovaLCT fails when the version to be installed is earlier than the current version.

Possible Causes
None.

Solution
Uninstall the current version, and then install the earlier one.

12.1.2 .NET Framework is missing

Problem
When installing NovaLCT, you run into a system prompt like "To run this application, you must first install one of the
following versions of the .NET Framework." (This typically appears on computers that have not previously installed
NovaLCT.)

Possible Causes
The required .NET Framework version is missing on the computer where NovaLCT is installed.

Solution
Visit NovStar's official website (www.novastar.tech) and download the required .NET Framework.
Download path: Downloads > Software > Framework

Figure 12-1 Download .NET Framework

12.1.3 "DeleteFile failed" error

Problem
When installing NovaLCT, you run into a system prompt like "An error occurred while trying to replace the existing file.
DeleteFile failed with code 5. Access denied."

www.novastar.tech 135
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

Possible Causes
The monitoring daemon is still running after shutting down NovaLCT, causing some files to be unable to be deleted.

Solution
Open the task manager, right-click on "MonitorDaemon", select "End task" from the pop-up menu, then click "Retry"
to proceed with the installation of NovaLCT.

Figure 12-2 Task manager

12.1.4 Prompts to run DPinst.exe

Problem
At the end of the installation process for NovaLCT, when starting the installation of the driver, you run into a system
prompt like "You need to run the 64-bit version of DPinst.exe on this computer. Please contact the software developer
who provided you with this software package." (This typically appears on computers that have not previously installed
NovaLCT.)

Possible Causes
The required driver is missing on the computer where NovaLCT is installed.

Solution
Proceed with the installation disregarding the issue at hand. Once completed, test if NovaLCT is able to connect to
the device via the USB cable.
 If you are able to connect to the device with no issue, there is no need for any further action as NovaLCT can be
used as intended.
 If you are unable to connect to the device, visit NovStar's official website (www.novastar.tech) and download the
required driver. Please contact NovaStar if the problem persists after installing the driver.
Download path: Downloads > Software > Driver

Figure 12-3 Download driver

www.novastar.tech 136
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

12.2 Other Problems


12.2.1 "No Screen" displayed in NovaLCT

Problem
“No Screen” is displayed in NovaLCT as shown in Figure 12-4.

Figure 12-4 No screen

Possible Causes
Failed to read screen configuration or no screen has been configured.

Solution

 If the LED screen has been configured already, click and select the Screen Connection tab, and then
click Read from HW to read the configurations from the LED screen.
 If the screen has not been configured yet, configure it first.

12.2.2 Permission error

Problem
After NovaLCT is installed on the system disk of the computer that runs Windows 8 or later version, some functions in
NovaLCT cannot work normally.

Possible Causes
File permission denied.

Solution
Here, we use Windows 10 as an example to illustrate how to solve this problem.

Step 1 Right click the desktop shortcut of NovaLCT and select Open file location.

www.novastar.tech 137
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

Step 2 Go back to the upper level of current file directory, that is, “\Nova Star\NovaLCT”.

Step 3 Right click the Bin folder and select Properties.

Step 4 Select the Security tab.

Figure 12-5 Security

Step 5 Check whether there is current user or Everyone in the Group or user names area.
 Yes: Go to Step 11.

 No: Go to Step 6.

Step 6 Click Edit to open the dialog box shown in Figure 12-6.

Figure 12-6 Changing permissions

Step 7 Click Add to open the dialog box shown in Figure 12-7.

www.novastar.tech 138
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

Figure 12-7 Selecting users or groups

Step 8 Click Advanced to open the dialog box shown in Figure 12-8, and click Find Now.

Figure 12-8 Advanced settings

Step 9 Select current user or Everyone in the search result, and click OK.

Step 10 Click OK.

Step 11 Select all for the Allow column and click OK.

www.novastar.tech 139
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

Figure 12-9 Setting permissions

Step 12 Click OK and close the properties dialog box.

12.2.3 Failed to connect colorimeter

Problem
The colorimeter connection fails when the colorimeter is used to automatically measure the original color space of the
screen.

Possible Causes
 The colorimeter connection is abnormal.

 The model of the colorimeter selected is incorrect.

Solution
Step 1 Check whether the hardware connection of the colorimeter is normal.

When the colorimeter model is CS-100A, follow the subsequent descriptions to make sure the colorimeter auto mode
is turned on.
Turning on auto mode: Set switch to ON while pressing the F button. When you see a C letter on the LCD, the auto
mode is turned on, which is shown in Figure 12-10.

Figure 12-10 Setting CS-100A colorimeter

 Normal: Go to .
www.novastar.tech 140
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

 Abnormal: Reconnect the colorimeter and make sure the colorimeter can work normally.

 Check whether the colorimeter model selected in NovaLCT is correct.

 Correct: Go to Step 2.

 Incorrect: Select the correct model.

Step 2 In NovaLCT, click Connect to reconnect the colorimeter.

12.2.4 No available server for VNNOX Care

Problem
No available server from the dropdown list for VNNOX Care services.

Figure 12-11 VNNOX Care services

Possible Causes
The network or antivirus software may be the cause of the issue.

Solution
You can try the following methods to resolve this issue:
 Disable your computer's firewall or your company's network firewall and try again. Or try from a different computer
if the problem persists.
 Uninstall the antivirus software (release the quarantined files) and reinstall NovaLCT.

www.novastar.tech 141
NovaLCT LED Configuration Tool for
Synchronous Control System User Manual

13 FAQs
13.1 How do I set the proxy when NovaLCT needs to access WAN network?
Question
When NovaLCT in LAN network needs to access WAN network, how to set the proxy?

Answer

Step 1 On the taskbar, right click and choose System Setting.

Figure 13-1 Setting proxy

Step 2 Select Enable Proxy.

Step 3 Enter the proxy address and port.

Step 4 Click Test Proxy.

Step 5 After the test succeeds, click Setting.

www.novastar.tech 142

You might also like