0% found this document useful (0 votes)
15 views24 pages

Product Information FLOWSIC600 XT Gas Flow Meters en IM0066865

The FLOWSIC600-XT is an advanced ultrasonic gas flow measuring device designed for custody transfer applications, offering maximum measurement accuracy and long-term stability. It features innovative technologies such as i-diagnostics™ for intelligent diagnostics and PowerIn Technology™ for continuous operation during power failures. Available in multiple versions, it meets various national and international standards, ensuring compatibility and ease of integration into existing systems.

Uploaded by

nadirabh2008
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
15 views24 pages

Product Information FLOWSIC600 XT Gas Flow Meters en IM0066865

The FLOWSIC600-XT is an advanced ultrasonic gas flow measuring device designed for custody transfer applications, offering maximum measurement accuracy and long-term stability. It features innovative technologies such as i-diagnostics™ for intelligent diagnostics and PowerIn Technology™ for continuous operation during power failures. Available in multiple versions, it meets various national and international standards, ensuring compatibility and ease of integration into existing systems.

Uploaded by

nadirabh2008
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 24

P R O D U C T I N FO R M AT I O N

FLOWSIC600-XT
THE PERFECT MATCH

Gas flow meters


FLOWSIC600-XT: THE PERFECT MATCH
Just how can the market leader for reliable, maximum precision ultrasonic gas flow measuring devices get
any better? The answer is easy: by carefully listening to and consistently responding to the requirements
of individual users.
With four device versions, the FLOWSIC600-XT is able to meet any application requirement as a stand-
alone or system solution – and deliver best possible measuring performance at the same time. Along with
its groundbreaking design, this product family impresses with innovative intrinsic value: i-diagnostics™ the
built-in solution, which delivers intelligent application diagnostics and PowerIn Technology™ continues to
take measurements and save valuable data for up to three weeks in the event of a mains power failure.
FLOWSIC600-XT delivers the ideal combination of maximum measurement accuracy, long-term stability,
and unrivaled operational safety, yet is entirely unassuming.

2 U l t r a s o n i c g a s f l o w m e a s u r i n g d e v i c e s | SIC K 8018938/2017-12
Subject to change without notice
8018938/2017-12 U l t r a s o n i c g a s f l o w m e a s u r i n g d e v i c e s | SIC K 3
Subject to change without notice
FLOWSIC600-XT Gas flow meters

Measurement data reliability and Simple device integration – even Quick and easy device commis-
availability in compact systems sioning and checks
The FLOWSIC600 ultrasonic gas flow Continuous improvement of ultrasound i-diagnosticsTM helps make device
measuring device already provides technologies is a tradition at SICK, commissioning and status checks
best-in-class long-term stability in ex- Germany. The FLOWSIC600-XT boasts quick and easy, and provides extensive
treme ambient conditions, and now the state-of-the-art measurement technolo- flow meter and application diagnostics
FLOWSIC600-XT combines the features gy, meaning it delivers extremely precise during operation. Should maintenance
of its predecessor with unprecedented measurement results. Compliant with ever be required, the intelligent solution
usability. It meets all the requirements ISO 17089 and AGA9 and compatible assistant provides support. The built-in
for safe and stable custody transfer gas with its predecessor the FLOWSIC600, it infrared interface means measured
measurement throughout its service life. can be integrated successfully into any value and diagnostics data can be
Measurement and diagnostics data and system. Plus, the new FLOWSIC600-XT accessed in no time, making servicing
status changes can be recorded perma- Forte meets the requirements of com- quick and efficient.
nently in six accessible data archives, pact installations and complies with
and the FLOWSIC600-XT’s PowerIn Tech- all of the specifications of OIML R 137
nology™ ensures that measurements Classes 1.0 and 0.5.
continue to be taken and data stored in
the event of a mains power failure.

4 U l t r a s o n i c g a s f l o w m e a s u r i n g d e v i c e s | SIC K 8018938/2017-12
Subject to change without notice
Gas flow meters FLOWSIC600-XT

FLOWSIC600-XT – PROVIDING YOU WITH THE PERFECT GAS FLOW


METER FOR ANY APPLICATION
Each of the ultrasonic gas flow meters in the FLOWSIC600-XT product family has been designed for
custody transfer applications and fulfills the requirements of all the common national and international
standards. There are four device versions to choose from to meet specific gas flow meter performance
requirements. Determining which one to use varies, which is why our performance-oriented classification
of the FLOWSIC600-XT, -XT Forte, -XT 2plex, and -XT Quatro is the ideal first step in ensuring there is a
focus on the task at hand and customer requirements, allowing a unique solution to be provided. All of the
FLOWSIC600-XT versions can be installed with ease into any custody transfer measurement application
with a nominal width of between 3 and 48 inches, and they can also be conveniently connected to all of
the most popular flow computers on the market.

FLOWSIC600-XT FLOWSIC600-XT Forte


The FLOWSIC600-XT has proven to be a versatile device suit- Providing impressive meter performance in a limited space
able for all custody transfer natural gas applications, with and combining eight paths on two different path levels in
15 years of field experience gained from the FLOWSIC600 one device, the FLOWSIC600-XT Forte guarantees maximum
having been incorporated into this four-path technology. measurement accuracy. It is the natural first choice for in-
stallations in systems with short inlet and outlet piping.

FLOWSIC600-XT 2plex FLOWSIC600-XT Quatro


The extremely compact FLOWSIC600-XT 2plex is the combi- The FLOWSIC600-XT Quatro combines two measurement
nation of a gas flow meter for custody transfer applications devices for redundant measurements in custody transfer
and a check measurement device, featuring extended natural gas applications in one, with an installation length
diagnostic functionality thanks to its additional independent equivalent to that of a single device.
measurement path.

8018938/2017-12 U l t r a s o n i c g a s f l o w m e a s u r i n g d e v i c e s | SIC K 5
Subject to change without notice
FLOWSIC600-XT Gas flow meters

Quick and easy data access


In addition to its numerous interfaces, the FLOWSIC600-XT also
enables quick and easy access to measured value and diagnos-
tics data thanks to the infrared communications port built into
its front display. All of the necessary settings and device data are
accessible via this interface. The FLOWSIC600-XT can also be
extended for wireless communication.

PowerIn TechnologyTM – data security guaranteed


Operating with an extremely low power consumption and measurement algorithms
that have been further optimized, the FLOWSIC600-XT is setting new standards for
ultrasonic gas flow meters. It boasts a highly efficient energy concept, including a
backup battery that guarantees a continuous power supply even in the event of a
mains power failure. If this does happen, the power consumption of all of the elec-
tronics is automatically reduced to the minimum level possible. We call this PowerIn
Technology™. It makes sure that measurements can continue to be taken for up to
three weeks without the need for external power and saves important measurement
data. This extremely efficient electronics concept is forward-thinking in the way it
allows for autonomous device operation, for example using a solar power supply.

IR

Automatic correction of measured values under


changing operating conditions
The FLOWSIC600-XT provides even more accurate measurements
than its predecessor, with its integrated geometry and Reynolds
number correction function boosting measurement accuracy
under changing pressure and temperature conditions. Another
advantage of the integrated pressure and temperature correction
function is the ease and safety with which calibration conditions
can be transferred over to application conditions. The pressure
and temperature values required to enable this feature are provid-
ed by built-in sensors, transmitters externally connected via HART,
or a flow computer.

6 U l t r a s o n i c g a s f l o w m e a s u r i n g d e v i c e s | SIC K 8018938/2017-12
Subject to change without notice
Gas flow meters FLOWSIC600-XT

i-diagnostics™ – an essential tool for effective and efficient device and application diagnostics
i-diagnostics™ has so much more to offer than just diagnostics – it is an intelligent combination of firmware and software that
means the device is safe, reliable, and easy to use for the entire operating time. i-diagnostics™ builds on the FLOWSIC600’s CBM
(condition based maintenance) smart self-diagnosis functionality, providing useful information about the system status and any
changes to it, in addition to device diagnostics. In order to assess the application, diagnostics data from cross-eyed beams is
first factored in, with application faults, such as blocked flow conditioners, background noise, contamination, and liquids in the
gas, being detected immediately – making lengthy troubleshooting a thing of the past. Process data is constantly assessed on
the basis of the integrated FingerPrint concept. This means that the measurement conditions during calibration can be compared
with the measurement conditions during commissioning and with the current measurement and diagnostics data. An internal
data logger continuously logs measured values for trend analyses to allow the historical measurement processes to be checked,
as well as the results of the self-monitoring. A retroactive thorough check of the measurement process in the form of a graphic
trend analysis is also possible.

FLOWgate™ – new and intuitive operating software


FLOWgate™ intelligently links diagnostics data together and then displays it. The quick status function provides immediate infor-
mation about the current status of the application, and if a warning limit is reached, the solution assistant can be used to analyze
the problem at the click of a button. In order to get a quick overview or analysis, each user can put together measured values and
diagnostics parameters as required in the measured value overview, and then amend or save their overview. FLOWgate™ allows
the FLOWSIC600-XT, and in turn all of the measured value and diagnostics data, to be accessed at any time via a PC or tablet –
whether online or offline. The graphical display of trend analyses in charts facilitates the analysis of the measurement process
and provides information on changes to the process. Concise diagnostics, maintenance, and calibration reports can be created
at any time using the report manager, while a range of wizards, including one for commissioning, make it much easier to operate
the device.

FLOWgateTM overview

8018938/2017-12 U l t r a s o n i c g a s f l o w m e a s u r i n g d e v i c e s | SIC K 7
Subject to change without notice
FLOWSIC600-XT Gas flow meters

A
B THE PERFECT MATCH
C Product description

D As the follow-up to the successful


FLOWSIC600, the FLOWSIC600-XT
ultrasonic gas flow measuring device is
The FLOWSIC600-XT contains
i-diagnostics™ – an intelligent applica-
tion diagnostics function – and PowerIn

E setting new standards in its market seg-


ment.The FLOWSIC600-XT is available in
variants with 4, 4+1, 4+4, and 8 mea-
Technology™, which enables continuous
measurement operation for up to three
weeks in the event of a mains voltage

F
surement paths to meet the require- failure. These functions help ensure
ments of every application, whether it is usability and unparalleled operational
being used as a stand-alone or system safety – and what’’s more, the equip-
solution. In addition to the OIML R ment offers the very best possible
137 Class 1.0 requirements, the FLOW- measurement accuracy and long-term
SIC600-XT meets the requirements of stability.

H
Class 0.5 and AGA9 in their entirety.

At a glance

I • User-friendly product family


• Automatic correction of pressure and
temperature effects
• Intelligent application diagnostics
with i-diagnostics™
• Extendable with flow computers per

J • Available for all operating conditions


• PowerIn Technology™ for reliable
backup operation
connect-and-go

K Your benefits
• Low measurement uncertainty in • Simple device integration – even in

L every application
• Excellent measurement data reliabili-
compact systems
• Quick and easy commissioning and
ty and availability checks

M • The right ultrasonic gas flow mea-


suring device for every application –
without compromise

N
O C
®

US

P Additional information
Fields of application ����������������������������9

Q Detailed technical data������������������������9


Measuring ranges����������������������������� 12

R
Ordering information������������������������� 13
Dimensional drawings����������������������� 14
Instruction for installation ��������������� 14
-- www.sick.com/FLOWSIC600-XT

S Dimensions ��������������������������������������� 15 For more information, simply visit the above link to obtain direct access to technical data, CAD design models, oper-
ating instructions, software, application examples, and much more.

T 8 U l t r a s o n i c g a s f l o w m e a s u r i n g d e v i c e s | SIC K 8018938/2017-12
Subject to change without notice
Gas flow meters FLOWSIC600-XT

Fields of application
• Custody transfer measurement of natural gas • Onshore and offshore applications
A
• Transport and storage of gas • Gas production applications with H2S and CO2 content

Detailed technical data


B
C
The exact device specifications and performance data of the product may deviate from the information provided here, and depend on the appli-
cation in which the product is being used and the relevant customer specifications.

System
Measured values Volumetric flow, a. c., volume a. c., gas velocity, sound velocity, Optional volume correction via
integrated EVC
D
E
Number of measuring paths 4, 4+1 (2plex), 4+4 (Quatro), 8 (Forte)
Measurement principle Ultrasonic transit time difference measurement
Measuring medium Natural gas, air, natural gases with contents of CO2, N2, H2S, O2
Measuring ranges
Qmin from ... to 5 ... 750 m³/h
F
Qmax from ... to 1,000 ... 120,000 m³/h
Measuring ranges depend on nominal pipe size
Repeatability ≤ 0.05 % of the measured value
Accuracy
Error limits Q t ... Qmax H
4-path and 8-path version: ≤ ± 0.5 %

4-path and 8-path version:


Dry calibrated
≤ ± 0.2 %
After flow calibration and adjustment with constant factor. Without uncertainty of the calibra-
I
J
tion test facility.
4-path and 8-path version: ≤ ± 0.1 %
After flow calibration and adjustment with polynomial or piecewise correction. Without uncer-
tainty of the calibration test facility.
Min. piping requirements
4-path version According OIML Class 1.0: with straight inlet section of ≥ 10D or ≥ 5D with flow conditioner
K
According OIML Class 0.5: with straight inlet section of ≥ 10D and flow conditioner
8-path version According OIML Class 1.0: with straight inlet section of ≥ 2D
According OIML Class 0.5: with straight inlet section of ≥ 5D L
For details see operating instructions
Diagnostics functions i-diagnostics™: integrated device diagnostics and intelligent extended device and applica-
tion diagnostics via FLOWgate™ software M
Gas temperature

On request:
–40 °C ... +180 °C
–194 °C ... +280 °C
N
O
Operating pressure 0 bar (g) ... 160 bar (g)
On request: 0 bar (g) ... 450 bar (g)
Nominal pipe size

P
3 ″ ... 56 ″
(DN 80 ... DN 1400), other nominal pipe sizes on request
Ambient temperature

Q
–40 °C ... +70 °C
(–60 °C ... +70 °C with enclosure for electronics)
Storage temperature –40 °C ... +70 °C
(-60 °C ... +70 °C meter body only)
Ambient humidity ≤ 95 %
Relative humidity; non-condensing R
S
8018938/2017-12
Subject to change without notice
U l t r a s o n i c g a s f l o w m e a s u r i n g d e v i c e s | SIC K 9
T
FLOWSIC600-XT Gas flow meters

A Conformities OIML R 137-1&2:2012


OIML D 11:2013
ISO 17089-1

B AGA-Report No. 9
MID: 2014/32/EU
PED: 2014/68/EU

C
ATEX: 2014/34/EU
EMC: 2014/30/EU
GOST 8.611-2013
GOST 8.733-2011

D Ex-approvals
IECEx Ex db ia op is [ia Ga] IIA/IIC T4 Gb

E
Ex db eb ia op is [ia Ga] IIA/IIC T4 Gb
Ex ia op is IIA/IIC T4 Ga
Ex ia nA op is IIC T4 Gc
ATEX II 2 (1) G Ex db ia op is [ia Ga] IIA/IIC T4 Gb

F II 2 (1) G Ex db eb ia op is [ia Ga] IIA/IIC T4 Gb


II 1G Ex ia op is IIA/IIC T4 Ga
II 3G Ex ia nA op is IIC T4 Gc
NEC/CEC (US/CA) Explosion-proof / non-incendive:
CI I, Div. 1 Group D, T4 / Ex d ia [ia Ga] IIA T4 Gb / Cl I, Zone 1 AEx d ia op is [ia Ga] IIA T4 Gb
CI I, Div. 1 Groups A, B, C, D, T4 / Ex ia IIC T4 Ga / Cl I, Zone 0, AEx ia op is IIC T4 Ga

H CI I, Div. 1 Groups B, C, D, T4 / Ex d ia [ia Ga] IIC T4 Gb / Cl I, Zone 1 AEx d ia op is [ia Ga]


IICT4 Gb
Intrinsically safe:
CI I, Div. 1 Group D T4 / Ex ia IIA T4 Ga / Cl I, Zone 0, AEx ia op is IIA T4 Ga

I CI I, Div. 1 Groups A, B, C, D, T4 / Ex ia IIC T4 Ga / Cl I, Zone 0, AEx ia op is IIC T4 Ga


Non-incendive
CI I, Div. 2 Groups A, B, C, D, T4 / Ex ia nA IIC T4 Gc / Cl I, Zone 2, AEx ia nA op is IIC T4 Gc

J Enclosure rating
IP66 / IP67

K
Analog outputs 1 output:
4 ... 20 mA, ≤ 250 Ω
Active/passive, electrically isolated
Digital outputs 4 outputs: 2 x status, 2 x pulse

L ≤ 30 V, 50 mA
Passive, electrically isolated, Open Collector or according to NAMUR (EN 50227), fmax =
10 kHz (scalable)

M
Modbus l
Type of fieldbus integration TCP
RTU RS-485 (3x)

N
ASCII RS-485 (3x)
Ethernet l
Remark Option

O HART
Remark
l
HART master (for connection of external pressure and temperature transmitters)
Optical interface l

P Serial
Remark Service interface (IR, according IEC 62056-21)
l

Q
Remark Encoder
Operation Via display and software FLOWgate™
Dimensions (W x H x D) See dimensional drawings and tables

R Weight
Material in contact with media
See table “Dimensions”
Low temperature carbon steel, stainless steel, duplex steel

S
T 10 U l t r a s o n i c g a s f l o w m e a s u r i n g d e v i c e s | SIC K 8018938/2017-12
Subject to change without notice
Gas flow meters FLOWSIC600-XT

Electrical connection
Voltage Electrically isolated: 12 ... 24 V DC
A
Intrinsically safe: 6 ... 16 V DC

Power consumption
PowerIn technology™ with back-up battery (2,400 mAh, 10.8 V), optional
0.45 W ... 2.45 W
B
Depending on electronics configuration
Integrated components Integrated pressure sensor and temperature sensor for correction of pressure and tempera-
ture effects (option)
C
Volume correction
Correction method PTZ (optional integrated)
D
E
Compressibility SGERG88
AGA 8 Gross method 1
AGA 8 Gross method 2
AGA NX-19
AGA NX-19 mod.
NX-19 mod. (GOST)
F
GERG91 mod. (GOST)
Fixed value
Data archives 1 diagostics archive (6,000 entries)
2 measurement periodic archives (6,000 entries each)
Logbooks Event log book (1,000 entries)
Parameter log book (200 entries)
Metrology log book (50 entries)
H
I
J
K
L
M
N
O
P
Q
R
S
8018938/2017-12
Subject to change without notice
U l t r a s o n i c g a s f l o w m e a s u r i n g d e v i c e s | SIC K 11
T
FLOWSIC600-XT Gas flow meters

A Measuring ranges
Measuring ranges, metric

B Nominal
pipe size
Extendet flow rate range acc. MID
Standard flow rate range acc. MID

C
Extended MID Standard MID MID transition flow MID maximum flow Non-MID maximum
minimum flow rate minimum flow rate rate rate flow rate
m³/h m³/h m³/h m³/h m³/h

D
Extended Qmin Standard Qmin Acc. ISO 17089 Qt Standard Qmax Extended Qmax
DN 80 (3″) 5 8 40 650 1,000
DN 100 (4″) 8 13 65 1,000 1,600

E DN 150 (6″)
DN 200 (8″)
16
20
20
32
100
160
2,500
4,000
3,000
4,500
DN 250 (10″) 25 50 240 6,500 7,000

F DN 300 (12″)
DN 350 (14″)
35
45
65
80
310
420
7,800
10,000
8,000
10,000
DN 400 (16″) 60 120 550 13,000 14,000
DN 450 (18″) 100 130 700 16,000 17,000
DN 500 (20″) 130 200 850 20,000 20,000

H DN 550 (22″)
DN 600 (24″)
150
180
260
320
1,000
1,200
24,000
28,000
24,000
32,000

I
DN 650 (26″) 240 450 1,400 32,000 35,000
DN 700 (28″) 280 650 1,700 36,000 40,000
DN750 (30″) 320 650 1,900 40,000 45,000

J DN 800 (32″)
DN 850 (34″)
360
400
800
900
2,200
2,500
43,000
47,000
50,000
55,000
DN 900 (36″) 450 1,000 2,800 51,000 66,000

K DN 950 (38″)
DN 1000 (40″)
500
550
1,100
1,200
3,100
3,400
56,000
60,000
70,000
80,000

L DN 1050 (42″)
DN 1100 (44″)
600
650
1,300
1,400
3,800
4,100
65,000
70,000
85,000
90,000
DN 1150 (46″) 700 1,500 4,500 72,000 95,000

M DN 1200 (48″)
DN 1300 (52″)
750
900
1,600
1,700
4,800
5,600
80,000
90,000
100,000
110,000

N
DN 1400 (56″) 1,000 1,800 6,500 100,000 120,000
When using an installation configuration with flow conditioner the maximum allowed gas velocity in the pipe is limited to 40 m/s

O
P
Q
R
S
T 12 U l t r a s o n i c g a s f l o w m e a s u r i n g d e v i c e s | SIC K 8018938/2017-12
Subject to change without notice
Gas flow meters FLOWSIC600-XT

Measuring ranges, imperial


A
Nominal
pipe size
Extendet flow rate range acc. MID
Standard flow rate range acc. MID
B
C
Extended MID Standard MID MID transition MID maximum Non-MID maximum
minimum flow rate minimum flow rate flow rate flow rate flow rate
Ft³/h Ft³/h Ft³/h Ft³/h Ft³/h

D
Extended Qmin Standard Qmin Acc. ISO 17089 Qt Standard Qmax Extended Qmax
3″ (DN 80) 180 280 1,400 23,000 35,000
4″ (DN 100) 290 460 2,300 35,300 56,000
6″ (DN 150)
8″ (DN 200)
570
710
710
1,130
3,500
5,700
88,000
141,300
106,000
159,000
E
10″ (DN 250) 880 1,800 8,500 230,000 247,000
12″ (DN 300)
14″ (DN 350)
1,200
1,600
2,300
2,800
10,900
14,800
276,000
353,000
283,000
354,000
F
16″ (DN 400) 2,100 4,200 19,400 459,000 495,000
18″ (DN 450) 3,500 4,600 24,700 565,000 602,000
20″ (DN 500) 4,600 7,100 30,000 706,000 708,000
22″ (DN 550)
24″ (DN 600)
5,300
6,400
9,200
11,300
35,000
42,000
848,000
989,000
850,000
1,133,000
H
I
26″ (DN 650) 8,500 15,900 49,000 1,130,000 1,240,000
28″ (DN 700) 9,900 23,000 60,000 1,271,000 1,420,000
30″ (DN 750) 11,300 23,000 67,000 1,413,000 1,590,000
32″ (DN 800)
34″ (DN 850)
12,700
14,200
28,300
31,800
78,000
88,000
1,519,000
1,660,000
1,770,000
1,950,000
J
36″ (DN 900) 15,900 35,300 99,000 1,801,000 2,337,000
38″ (DN 950)
40″ (DN 1000)
17,700
19,500
38,800
42,400
109,000
120,000
1,978,000
2,119,000
2,479,000
2,833,000
K
42″ (DN 1050)
44″ (DN 1100)
21,200
23,000
45,900
49,400
134,000
145,000
2,296,000
2,472,000
3,010,000
3,187,000 L
46″ (DN 1150) 24,800 53,000 159,000 2,543,000 3,364,000
48″ (DN 1200)
52″ (DN 1300)
26,600
31,800
56,500
60,000
170,000
198,000
2,825,000
3,178,000
3,541,000
3,885,000
M
N
56″ (DN 1400) 35,300 63,600 230,000 3,532,000 4,238,000
When using an installation configuration with flow conditioner the maximum allowed gas velocity in the pipe is limited to 131 ft/s

O
P
Q
R
S
8018938/2017-12
Subject to change without notice
U l t r a s o n i c g a s f l o w m e a s u r i n g d e v i c e s | SIC K 13
T
FLOWSIC600-XT Gas flow meters

A Ordering information
Our regional sales organization will help you to select the optimum device configuration.

B Dimensional drawings (Dimensions in mm (inch))


FLOWSIC600-XT and FLOWSIC600-XT Forte

C
D
B

D
C
F A E

FLOWSIC600-XT 2plex and FLOWSIC600-XT Quatro

H
I
B + 165 ( B + 6.50)

J
K

D
C

L A E

M FLOWSIC600-XT: 3” design for up to Class 600/PN100 pressure levels

N
O
B

D
C

P A E

Q
R
S
T 14 U l t r a s o n i c g a s f l o w m e a s u r i n g d e v i c e s | SIC K 8018938/2017-12
Subject to change without notice
Gas flow meters FLOWSIC600-XT

Instruction for installation


Installation of FLOWSIC600-XT in pipeline for unidirectional use (minimum requirements)
A
B
≥ 3 DN
≥A 1 ... 5 DN


C

DN
D
A


E
≥A ≥D
≥B ≥C E


F
B
 

1 FLOWSIC600-XT
H
2 Temperature measuring point

I
3 Flow conditioner

Configuration A Configuration B
Number of Number of
measuring
paths
OIML R 137 A measuring OIML R 137 A 1)
paths
A B C D E
J
4 Class 1.0 10 DN 4 Class1.0 5 DN 2 DN 3 DN 3 DN 1 ... 5 DN
8
8
Class 1.0
Class 0.5
2 DN
5 DN
4
8
Class 0.5
Class 1.0/0.5
10 DN
5 DN
2 DN
2 DN
8 DN
3 DN
3 DN
3 DN
1 ... 5 DN
1 ... 5 DN
K
Number of
measuring
AGA Report 9,
3rd Edition, July A
Number of AGA Report 9,
measuring 3rd Edition, July A B C D E
L
paths 2017 paths 2017 2)

4
“Metering
package per-
formance” acc.
20 DN 4
“Metering
package per-
formance” acc.
10 DN 5 DN 5 DN 5 DN 2.5 DN M
§ 6.3 § 6.3

8
“Metering
package per-
formance” acc.
5 DN 8
“Metering
package per-
formance” acc.
5 DN 2 DN 3 DN 5 DN 2.5 DN
N
O
§ 6.3 § 6.3

1)
Minimum requirements with PTB flow conditioner;

P
recommended installation for other flow conditioners on request
2)
Minimum requirements with CPA 50 E flow conditioner;
recommended installation for other flow conditioners on request

Q
R
S
8018938/2017-12
Subject to change without notice
U l t r a s o n i c g a s f l o w m e a s u r i n g d e v i c e s | SIC K 15
T
FLOWSIC600-XT Gas flow meters

A Installation of FLOWSIC600-XT in pipeline for bidirectional use (minimum requirements)


≥A ≥A

B
3 ... 5 DN 3 ... 5 DN
 

DN
C A


D
≥A ≥A
≥B ≥C ≥C ≥B
1 DN E

E  

DN
F
B
  

1 FLOWSIC600-XT
2 Alternative temperature measurement points

H
3 Flow conditioner

Configuration A Configuration B
Number of Number of

I measuring
paths
4
OIML R 137

Class 1.0
A

10 DN
measuring
paths
4
OIML R 137 A 1)

Class 1.0
A

5 DN
B

2 DN
C 3)

3 DN
E

1 DN

J 8
8
Class 1.0
Class 0.5
5 DN
5 DN
4
8
Class 0.5
Class 1.0/0.5
10 DN
5 DN
2 DN
2 DN
8 DN
3 DN
1 DN
1 DN

K Number of
measuring
paths
AGA report 9,
3rd Edition, July
2017
A
Number of
measuring
paths
AGA report 9,
3rd Edition, July
2017 2)
A B C D4)

L
“Metering “Metering
package per- package per-
4 20 DN 4 10 DN 5 DN 5 DN 2,5 DN
formance” acc. formance” acc.
§ 6.3 § 6.3

M 8
“Metering
package per-
formance” acc.
5 DN 8
“Metering
package per-
formance” acc.
6 DN 3 DN 3 DN 2,5 DN
§ 6.3 § 6.3

N 1)
Minimum requirements with PTB flow conditioner;
recommended installation for other flow conditioners on request

O 2)
Minimum requirements with CPA 50 E flow conditioner;
recommended installation for other flow conditioners on request
3)
When C ≥ 5 DN, the temperature measuring point in pipe section C must

P 4)
be positioned with a distance of 3 ... 5 DN
Meter packages shall be flow calibrated with thermowells installed

Q
R
S
T 16 U l t r a s o n i c g a s f l o w m e a s u r i n g d e v i c e s | SIC K 8018938/2017-12
Subject to change without notice
Gas flow meters FLOWSIC600-XT

Dimensions
Nominal Connection Standard Weight 1) Length (A) Hight 2) (B) Flange diame- Width of mea- Internal diame-
A
pipe size flange ter (C) suring section ter (E)

[kg] [mm] [mm] [mm]


(D)
[mm] [mm]
B
C
3″ Cl. 150 ANSI B16.5 75 240 454 190 205 73
Cl. 300 75 454 210
Cl. 600 75 454 210

DN 80
Cl. 900
PN 16 DIN 2633
120
75
400
240
461
454
240
200 D
PN 63 DIN 2636 75 454 215

4″
PN 100
Cl. 150
DIN 2637
ANSI B16.5
75
100 300
454
490
230
230 248 95
E
F
Cl. 300 110 490 255
Cl. 600 120 490 275
Cl. 900 130 500 490 290
DN 100 PN 16 DIN 2633 110 300 490 220
PN 63 DIN 2636 120 490 250

H
PN 100 DIN 2637 126 490 265
6″ Cl. 150 ANSI B16.5 128 450 540 280 330 142
Cl. 300 145 540 320
Cl. 600
Cl. 900
170
238 750
540
540
355
380
I
DN 150 PN 16 DIN 2633 140 450 540 285
PN 63
PN 100
DIN 2636
DIN 2637
162
176
540
540
345
355
J
8″ Cl. 150
Cl. 300
ANSI B16.5 255
276
600 617
617
345
380
415 190
K
Cl. 600 316 617 420

DN 200
Cl. 900
PN 16 DIN 2633
360
260
617
617
470
340
L
M
PN 63 DIN 2636 298 617 415
PN 100 DIN 2637 360 617 430
10″ Cl. 150 ANSI B16.5 377 750 691 405 420 235
Cl. 300
Cl. 600
411
485
691
691
445
510
N
Cl. 900 528 691 545
DN 250 PN 16
PN 63
DIN 2633
DIN 2636
383
434
691
691
405
470
O
12″
PN 100
Cl. 150
DIN 2637
ANSI B16.5
486
445 900
691
728
505
485 500 270 P
Cl. 300 494 728 520
Cl. 600
Cl. 900
560
645
728
685
560
610
Q
R
DN 300 PN 16 DIN 2633 441 728 460
PN 63 DIN 2636 509 728 530
PN 100 DIN 2637 585 638 585

S
8018938/2017-12
Subject to change without notice
U l t r a s o n i c g a s f l o w m e a s u r i n g d e v i c e s | SIC K 17
T
FLOWSIC600-XT Gas flow meters

A Nominal
pipe size
Connection
flange
Standard Weight 1) Length (A) Hight 2) (B) Flange diame-
ter (C)
Width of mea- Internal diame-
suring section ter (E)
(D)

B 14″ Cl. 150 ANSI B16.5


[kg]
475
[mm]
1,050
[mm]
642
[mm]
535
[mm]
540
[mm]
315
Cl. 300 600 667 585

C Cl. 600
Cl. 900
675
850
677
700
605
640

D DN 350 PN 16
PN 63
DIN 2633
DIN 2636
475
625
635
675
520
600
PN 100 DIN 2637 750 705 655

E 16″ Cl. 150


Fore al meters ≥ 16″ an installation length of 3D is optionally available
ANSI B16.5 672 762 844 595 610 360

F
Cl. 300 760 844 650
Cl. 600 857 844 685
Cl. 900 926 800 755 705
DN 400 PN 16 DIN 2633 658 762 844 580
PN 63 DIN 2636 794 844 670
18″ Cl. 150 ANSI B16.5 660 820 754 635 620 405

H Cl. 300
Cl. 600
760
960
792
820
710
745

I DN 450
Cl. 900 1,300 900 830
Data on request
785

20″ Cl. 150 ANSI B16.5 750 902 815 700 670 450

J Cl. 300
Cl. 600
930
1,080
853
872
775
815

K
Cl. 900 1,500 1,000 892 855
DN 500 PN 16 DIN 2633 700 902 823 715
22″ Data on request

L DN 550
24″ Cl. 150 ANSI B16.5 1,090 991
Data on request
927 815 760 540
Cl. 300 1,390 978 915

M Cl. 600
Cl. 900
1,615
2,100 1,200
990
1,040
940
1,040

N DN 600
26″
PN 16
Cl. 150
DIN 2633
ASME B16.47
1,015
1,475
991
1,050
940
965
840
870 828 585
Cl. 300 1,825 1,016 972

O Cl. 600
Cl. 900
2,100
2,500 1,250
1,038
1,073
1,016
1,086

P
DN 650 Data on request
28“ Cl. 150 ASME B16.47 1,950 1,100 1,027 927 862 630
Cl. 300 2,225 1,080 1,035

Q Cl. 600
Cl. 900
2,450
3,000 1,300
1,100
1,150
1,073
1,169
DN 700 Data on request

R
S
T 18 U l t r a s o n i c g a s f l o w m e a s u r i n g d e v i c e s | SIC K 8018938/2017-12
Subject to change without notice
Gas flow meters FLOWSIC600-XT

Nominal
pipe size
Connection
flange
Standard Weight 1) Length (A) Hight 2) (B) Flange diame-
ter (C)
Width of mea- Internal diame-
suring section ter (E) A
(D)

30″ Cl. 150 ASME B16.47


[kg]
2,195
[mm]
1,150
[mm]
1,080
[mm]
985
[mm]
902
[mm]
675 B
Cl. 300 2,545 1,135 1,092
Cl. 600
Cl. 900
2,820
3,350 1,350
1,154
1,205
1,130
1,232
C
DN 750
32″ Cl. 150 ASME B16.47 2,485 1,200
Data on request
1,145 1,061 979 720 D
Cl. 300 2,835 1,190 1,150
Cl. 600
Cl. 900
3,110
3,800 1,400
1,212
1,272
1,194
1,315
E
F
DN 800 Data on request
34″ Data on request
DN 850 Data on request
36″ Cl. 150 ASME B16.47 3,125 1,250 1,250 1,169 1,082 810
Cl. 300 3,525 1,300 1,270
Cl. 600 3,850 1,323 1,315

DN 900
Cl. 900 5,225 1,450 1,396
Data on request
1,461
H
38″ Cl. 150
Cl. 300
ASME B16.47 3,800
3,725
1,300 1,310
1,275
1,238
1,169
1,160 855
I
Cl. 600 4,300 1,325 1,270

DN 950
Cl. 900 Data on request 1,421
Data on request
1,461
J
K
40″ Cl. 150 ASME B16.47 3,825 1,350 1,359 1,289 1,213 900
Cl. 300 4,125 1,334 1,239
Cl. 600 4,675 1,375 1,321

DN 1000
Cl. 900 Data on request 1,470
Data on request
1,512
L
42″ Cl. 150 ASME B16.47 4,675 1,450 1,415 1,346 1,261 945
Cl. 300
Cl. 600
4,650
5,450
1,386
1,444
1,289
1,404
M
DN 1050
Cl. 900 Data on request 1,523
Data on request
1,562
N
44″ Data on request
DN 1100
46″
Data on request
Data on request
O
P
DN 1150 Data on request
48″ Cl. 150 ASME B16.47 6,400 1,600 1,574 1,511 1,416 1,080
Cl. 300 6,475 1,552 1,467
Cl. 600
Cl. 900
7,850
12,100 1,900
1,615
1,711
1,594
1,785
Q
DN 1200 Data on request
1)
Devices with single SPU; devices with double SPU: weight + 7 kg
2)
Optional neck extension: B + 200 mm
R
S
8018938/2017-12
Subject to change without notice
U l t r a s o n i c g a s f l o w m e a s u r i n g d e v i c e s | SIC K 19
T
NOTES

A
B
C
D
E
F

H
I
J
K
L
M
N
O
P
Q
R
S
T U l t r a s o n i c g a s f l o w m e a s u r i n g d e v i c e s | SIC K 8018938/2017-12
Subject to change without notice
NOTES

A
B
C
D
E
F

H
I
J
K
L
M
N
O
P
Q
R
S
8018938/2017-12
Subject to change without notice
U l t r a s o n i c g a s f l o w m e a s u r i n g d e v i c e s | SIC K 21
T
NOTES

A
B
C
D
E
F

H
I
J
K
L
M
N
O
P
Q
R
S
T U l t r a s o n i c g a s f l o w m e a s u r i n g d e v i c e s | SIC K 8018938/2017-12
Subject to change without notice
SERVICES

REGISTER AT WWW.SICK.COM TODAY AND


ENJOY ALL THE BENEFITS

m Select products, accessories, documentation and soft-


ware quickly and easily.
m Create, save and share personalized wish lists.
m View the net price and date of delivery for every product.
m Requests for quotation, ordering and delivery tracking
made easy.
m Overview of all quotations and orders.
m Direct ordering: submit even very complex orders in
moments.
m View the status of quotations and orders at any time.
Receive e-mail notifications of status changes.
m Easily repeat previous orders.
m Conveniently export quotations and orders to work with
your systems.

SERVICES FOR MACHINES AND SYSTEMS: SICK LifeTime Services


Our comprehensive and versatile LifeTime Services are the perfect addition to the comprehensive range of products from
SICK. The services range from product-independent consulting to traditional product services.

Consulting and design


Safe and professional

Product and system support


Reliable, fast and on-site

Verification and optimization


Safe and regularly inspected

Upgrade and retrofits


Easy, safe and economical

Training and education


Practical, focused and professional

8018938/2017-12 U l t r a s o n i c g a s f l o w m e a s u r i n g d e v i c e s | SIC K 23
Subject to change without notice
SICK AT A GLANCE
8018938/2017-12 ∙ 4MPS ∙ Pre USmod en47

SICK is a leading manufacturer of intelligent sensors and sensor solutions for industrial applications. With
almost 8,000 employees and over 50 subsidiaries and equity investments as well as numerous represen-
tative offices worldwide, we are always close to our customers. A unique range of products and services
creates the perfect basis for controlling processes securely and efficiently, protecting individuals from
accidents and preventing damage to the environment.

We have extensive experience in various industries and understand their processes and requirements.
With intelligent sensors, we can deliver exactly what our customers need. In application centers in Europe,
Asia and North America, system solutions are tested and optimized in accordance with customer specifica-
tions. All this makes us a reliable supplier and development partner.

Comprehensive services round out our offering: SICK LifeTime Services provide support throughout the
machine life cycle and ensure safety and productivity.

For us, that is “Sensor Intelligence.”

Worldwide presence:

Australia, Austria, Belgium, Brazil, Canada, Chile, China, Czech Republic, Denmark, Finland, France,
Germany, Great Britain, Hungary, India, Israel, Italy, Japan, Malaysia, Mexico, Netherlands, New Zealand,
Norway, Poland, Romania, Russia, Singapore, Slovakia, Slovenia, South Africa, South Korea, Spain,
Sweden, Switzerland, Taiwan, Thailand, Turkey, United Arab Emirates, USA, Vietnam.

Detailed addresses and additional representatives - www.sick.com

SICK AG | Waldkirch | Germany | www.sick.com

You might also like