www.pall.com/medical 2
QPoint™
Product description Docking Station - Tap Assembly with Quick Connect Inlet Filter Capsule, sterile
Order code I Description QDTC QJ212
Jet Outlet, 0.2 μm Filter
QJ22
Jet Outlet, 0.2 μm Filter
Packaging 1 unit/pkg 12 units/pkg - QJ212 2 units/pkg - QJ22
Membrane area (nominal) Not applicable 620 cm2 (96.1 in2)
Flow rates (nominal) Not applicable 5.7 L/min at 1 bar (1.5 gallons/min at 14.5 psi)
13.4 L/min at 3 bar (3.5 gallons/min at 43.5 psi)
18.8 L/min at 5 bar (5.0 gallons/min at 75 psi)
Diameter (nominal) 88 mm (3.5 in) 88 mm (3.5 in)
Weight (nominal) 84 g (2.96 oz) 119 g (4.19 oz)
Temperature Continuous influent temperature 60 °C (140 °F) during Continuous influent temperature 60 °C (140 °F) during
product installation product installation
Maximum influent temperature 75 °C (167 °F) for a total Maximum influent temperature 75 °C (167 °F) for a total
cumulative period of 90 minutes over the life of each cumulative period of 90 minutes over the life of each
connected Filter Capsule connected Filter Capsule
Maximum operating pressure 5 bar (75 psi) at continuous 60 °C (140 °F) influent 5 bar (75 psi) at continuous 60 °C (140 °F) influent
temperature temperature
Maximum life Reusable 62 days
Sanitisation External surfaces may be cleaned using common Compatible with common surface and systemic
sanitising agents. disinfection programs. Complementary to water safety
During routine water system disinfection the Docking plan sanitisation and hygiene protocols
Station with attached Filter Capsule can be left in place
to enable the outlet to be flushed
Main materials of construction Polycarbonate/Acrylonitrile Butadiene Styrene (51%), Glass Polyester (83%), Polypropylene (10%),
Filled Nylon (22%), Polyester (20%), Stainless Steel (4%) Polyethersulphone (5%), (Recyclable)
Packaging material Recycled cardboard outer packaging Recycled cardboard outer packaging. Ethylene Vinyl
Acetate (EVA) plastic film blister. Tyvek Polyethylene lid
www.pall.com/medical 3
Pall-Aquasafe™
Disposable Water Filters
Product description Disposable Shower Head Filter for up to 31 day use, sterile Disposable Tap Water Filter for up to 31 day use, sterile
Order code I Description AQF4 AQ31F1S, AQ31F1S2
AQF42 With smooth outlet
AQ31F1R, AQ31F1R2
With shower rose
Packaging AQF4 (12 units per case) AQ31F1S, AQ31F1R (12 units per case)
AQF42 (2 units per case) AQ31F1S2, AQ31F1R2 (2 units per case)
Membrane area (nominal) 1,020 cm2 (158.1 in2) 550 cm2 (85.3 in2)
Flow rates (nominal) 31.8 L/min at 5 bar (8.4 gallons/min at 75 psi) AQ31F1S, AQ31F1S2
17.3 L/min at 5 bar (4.6 gallons/min at 75 psi)
AQ31F1R, AQ31F1R2
17.4 L/min at 5 bar (4.6 gallons/min at 75 psi)
Length (excluding quick 240 mm (9.45 in) AQ31F1S, AQ31F1S2
connect adaptor - nominal) 72 mm (2.8 in)
AQ31F1R, AQ31F1R2
85 mm (3.4 in)
Temperature Continuous influent temperature 60 °C (140 °F) Continuous influent temperature 60 °C (140 °F)
Maximum influent temperature 70 °C (158 °F) for a total Maximum influent temperature 70 °C (158 °F) for a total
cumulative period of 30 minutes over the life of the filter cumulative period of 30 minutes over the life of the filter
Maximum upstream 5 bar (75 psi) at continuous 60 °C (140 °F) 5 bar (75 psi) at continuous 60 °C (140 °F)
operating pressure influent temperature influent temperature
Maximum filter life 31 days 31 days
Sanitisation Compatible with common surface and systemic Compatible with common surface and systemic
disinfection programs. Complementary to water safety disinfection programs. Complementary to water safety
plan sanitisation and hygiene protocols plan sanitisation and hygiene protocols
www.pall.com/medical 4
Pall-Aquasafe™
Disposable Water Filters (continued)
Product description In-Line Disposable Water Filter with Quick Connect Inlet Disposable Tap Filter for up to 7 day use, sterile
and Outlet Ports, sterile
Order code I Description AQIN AQ7FSN
With smooth outlet
AQ7FRN
With shower rose
Packaging 12 units per case 12 units per case
Membrane area (nominal) 550 cm2 (85.3 in2) 520 cm2 (80.6 in2)
Flow rates (nominal) 12.8 L/min at 5 bar (3.4 gallons/min at 75 psi) 10.8 L/min at 5 bar (2.9 gallons/min at 75 psi)
Length (excluding quick 70 mm (2.76 in) AQ7FSN
connect adaptor - nominal) 72 mm (2.83 in
AQ7FRN
85 mm (3.35 in)
Temperature Continuous influent temperature 60 °C (140 °F) Continuous influent temperature 50 °C (122 °F)
Maximum influent temperature 70 °C (158 °F) for a total Maximum influent temperature 70 °C (158 °F) for a total
cumulative period of 30 minutes over the life of the filter cumulative period of 30 minutes over the life of the filter
Maximum upstream 5 bar (75 psi) at continuous 60 °C (140 °F) 5 bar (75 psi) at continuous 60 °C (140 °F)
operating pressure
Maximum filter life 31 days 7 days
Sanitisation Compatible with common surface and systemic Complementary to water safety plan sanitisation and
disinfection programs. Complementary to water safety hygiene protocols
plan sanitisation and hygiene protocols
www.pall.com/medical 5
Pall-Aquasafe™
Disposable Water Filters (continued)
Product description Disposable Shower Head Filter for protection against Disposable Tap Water Filter for protection against
Legionella spp. for up to 31 day use Legionella spp. for up to 31 day use, sterile
Order code I Description AQL3 AQ31L1S
With smooth outlet
AQL3S AQ31L1R
Sterile With shower rose
Packaging 12 units per case 12 units per case
Membrane area (nominal) 1,100 cm2 (70.5 in2) 504 cm2 (78.1 in2)
Flow rates (nominal) 31.0 L/min at 5 bar (8.2 gallons/min at 75 psi) 17.4 L/min at 5 bar (4.6 gallons/min at 75 psi)
Length (excluding quick 240 mm (9.45 in) AQ31L1S
connect adaptor - nominal) 72 mm (2.83 in)
AQ31L1R
85 mm (3.35 in)
Temperature Continuous influent temperature 60 °C (140 °F) Continuous influent temperature 60 °C (140 °F)
Maximum influent temperature 70 °C (158 °F) for a total Maximum influent temperature 70 °C (158 °F) for a total
cumulative period of 30 minutes over the life of the filter cumulative period of 30 minutes over the life of the filter
Maximum upstream 5 bar (75 psi) at continuous 60 °C (140 °F) 5 bar (75 psi) at continuous 60 °C (140 °F)
operating pressure
Maximum filter life 31 days 31 days
Sanitisation Compatible with common surface and systemic Compatible with common surface and systemic
disinfection programs. Complementary to water safety disinfection programs. Complementary to water safety
plan sanitisation and hygiene protocols plan sanitisation and hygiene protocols
www.pall.com/medical 6
Quick Connect Adaptors For Water Filters –
Wash Basin, In-Line and Wall Shower Applications
Product description – Quick connect adaptors 1/2 in. female thread – Quick connect adaptors 1/2 in. female thread
Order code I Description TAP1/2FN Without valve TAP1/2FV With valve
Product description – Quick connect adaptors 1/2 in. male thread – Quick connect adaptors 1/2 in. male thread
Order code I Description TAP1/2MN Without valve TAP1/2MV With valve
Product description – Quick connect adaptors 22 mm female thread – Quick connect adaptors 22 mm female thread
Order code I Description TAP22FN Without valve TAP22FV With valve
Product description – Quick connect adaptors 24 mm male thread – Quick connect adaptors 24 mm male thread
Order code I Description TAP24MN Without valve TAP24MV With valve
www.pall.com/medical 7
Quick Connect Adaptors For Water Filters –
Wash Basin, In-Line and Wall Shower Applications
Product description – Wash basin and in-line applications – Wash basin and in-line applications
– Quick connect adaptors 1/2 in. male thread – Quick connect adaptors 1/2 in. female thread
Order code I Description SST1/2MN Stainless steel connector without valve, SST1/2FV Stainless steel connector with valve,
suitable for DI water suitable for DI water
Product description – Rotating adaptor for fixed wall shower – Fixed adaptor for fixed wall shower
Order code I Description FR2521-M24-12-ROT Rotating adaptor for PRESTO FR2521-M24-12-FIXE Fixed adaptor for PRESTO PL30
DL400 fixed wall shower fixed wall shower
www.pall.com/medical 8
Quick Connect Adaptors For Water Filters –
Flexible Hose Shower Applications
Product description – Quick connect adaptors 1/2 in. male thread – Quick connect adaptors 1/2 in. male thread
Order code I Description SHO1/2MNN Without valve, without restrictor SHO1/2MVN With valve, without restrictor
Product description – Quick connect adaptors 1/2 in. male thread – Quick connect adaptors 1/2 in. male thread
Order code I Description SHO1/2MNR Without valve, with restrictor SHO1/2MVR With valve, with restrictor
Accessories
Product name Pall-Aquasafe™ Detachable Shower Rose
Product description Specifically designed as an attachment to the Pall-Aquasafe
Water Filter (AQ7FSN or AQ31F1S), sterile
Order code I Description AQFROSE
Packaging 25 units per case
Maximum filter life Single use following attachment to the AQ7FSN or
AQ31F1S filter
Maximum continuous 40 ºC (104 ºF)
influent water temperature
Maximum upstream 5 bar (75 psi) at continuous 40 °C (104 °F) influent
operating pressure temperature
www.pall.com/medical 9
Pre-Filtration
Pall pre-filtration technologies can be installed either at the point of entrance or in-line within a building. They significantly reduce the amount of incoming
organic and inorganic particles, which may contribute to biofilm growth in your water distribution system. Furthermore, Pall pre-filtration technologies help
to protect your point-of-use (POU) filters from reduced longevity due to high particulate contamination.
Flow reduction or blockage of POU filters before their maximum lifetime is a strong indicator of heavy colloid and/or particulate load in your water distribution
system and highlights a need to perform additional water profile tests on the water quality such as silt density tests (SDI).
Pall Medical offers technical services such as SDI testings in your facilities. Based on those tests, suitable pre-filtration technologies can be selected from
a large Pall pre-filter portfolio. A selection of Pall pre-filtration technologies are described below. For further information, as well as ordering information,
please contact your local Pall Medical office.
www.pall.com/medical 10
In-Line Capsule Filtration
Pall Kleenpak™ capsules are durable and compact filter capsules available with a broad range of filter media and in four different sized formats designed
for a variety of applications.
A small selection of Posidyne membrane procedures are described below, but for further options available, please contact your local sales office.
Product Name Pall Kleenpak™ Capsule Filter with 0.2 µm Posidyne® Membrane
Order code I Description KA2NFZP4
With 6 mm (0.2 in) Walther male connectors
KA3NFZP5
With 12 mm (0.5 in) Walther male connectors
www.pall.com/medical 11
QPData
Product description Custom software data management tool for water filter traceability
Order code I Description QPData Full Service and Support Mode (Annual Fee)
QPDATA1
QPData Pre-loaded and Configured Smartphone
QPDATA2
QPData Paired and Compatible Scanner
QPDATA3
QPData Customer Smartphone Configuration
QPDATA4
Please note:
Data SIM card and/or contract is not included. The warranty of any hardware supplied by Microsec
and/or Pall is limited to the Manufacturer’s warranty.
Water Testing
Particle Analysis in Water Distribution Systems
Water distribution systems, particularly in older or large buildings may contain high levels of organic and inorganic material in the form of particles (such as,
sand, silicates, rust) and colloids. Those water contaminants may contribute to biofilm formation or be derived from already established biofilm within the
system. The particulate load in the water may visibly change the water colour. The turbidity of the water represents an indicator of the particulate/colloidal
concentration in the system.
Particulate and colloidal load in water distribution systems can be analyzed using the Silt Density Index test (SDI). Pall Life Sciences offers SDI testing in your facilities
by our specialists. Based on the individual review of the SDI report, system specific and cost effective prefiltration technologies can be selected from a large
Pall pre-filter portfolio in order to deliver maximum benefits for your water distribution system. Please contact your local Pall representative in order to find out
if an SDI test can be performed in your facility.
Please note: Flow reduction or blockage of POU sterilizing grade filters before their intended lifetime may indicate a high particulate
load in the water distribution system.
Filter Replacement
Pall Medical offers service to exchange Pall point-of-use filters and large-scale prefilter cartridges in your facility.
Due to the use of quick connectors, point-of-use filter exchange can be performed easily within seconds by trained cleaning or facilities maintenance staff,
nursing staff, or other trained persons. However, if desired and where possible, Pall Medical offers the option to exchange filters in your facility. This can be
performed using professional external technical service and cleaning companies in your area.
The exchange of Pall large-scale prefilter cartridges in cooperation with the technician in your facility may also be available.
Please contact your local Pall sales office in order to obtain more information about the availability of filter
exchange services in your area.
Turnkey Program
In some locations, Pall Medical offers a Turnkey Program that includes particulate water testing, microbial water analysis, filter replacement and
additional services.
Please contact your local sales office in order to obtain detailed information about this program and availability
of this service in your area.
www.pall.com/medical 12
PCR Technology
For information on the analytical discs, please contact your local sales office or visit www.pall.com.
www.pall.com/medical 13
Infusion Filters
Product name Pall Nanodyne™ ELD Filter Pall Nanodyne NEO Filter Pall Supor™ AEF Filter
Product description Infusion filter with endotoxin-retentive Infusion filter with endotoxin-retentive Infusion filter with low-protein-binding
Posidyne membrane Posidyne membrane and small volume Supor membrane
Order code I Description ELD96LLCE NEO96E AEF1E
0.9 mm ID microbore tubing, 0.5 mm ID ultra-microbore tubing, 0.9 mm ID microbore tubing,
slide clamp, luer connectors slide clamp, luer connectors slide clamp, luer connectors
ELD96LYLE NEO96NYE AEF1NTE
0.9 mm ID microbore tubing, 0.5 mm ID ultra-microbore tubing, Luer connectors, without tubing
slide clamp, luer connectors, slide clamp, luer connectors
Y-injection site Y-piece for needleless connection
ELD96LYLSE
3.0 mm ID standard bore tubing,
slide clamp, luer connectors,
Y-injection site
ELD96NTE
Luer connectors, without tubing
Packaging 40 units per case (ELD96NTE) 50 units per case 50 units per case
50 units per case (ELD96LLCE,
ELD96LYLE, ELD96LYLSE)
Volume 2 mL plus tubing volume 0.4 mL AEF1E
1.0 mL
AEF1NTE
0.7 mL
Membrane 0.2 µm Posidyne membrane 0.2 µm Posidyne membrane 0.2 µm Supor membrane
Filter and tubing Non-phthalate fluid pathway, Non-phthalate fluid pathway, Non-phthalate fluid pathway,
free of latex free of latex free of latex
Special features Air elimination Air elimination Air elimination
Maximum filter life 96 h 96 h 24 h
Information for use Single patient use Single patient use Single patient use
www.pall.com/medical 14
Infusion Filters (continued)
Product name Pall Lipipor™ TNA Filter Pall Lipipor TNA Filter Pall Lipipor NEO and Lipipor NLF Filters
Product description Filter for lipid-containing solutions for Filter for lipid-containing solutions for Infusion filters for lipid-containing
parenteral nutrition parenteral nutrition – allows for solutions for parenteral nutrition in
infusion under gravity paediatric and neonatal patients
Order code I Description TNA1E TNA2E NLF1E
0.9 mm ID microbore tubing, 3.0 mm ID standard bore tubing, 0.9 mm ID microbore tubing,
luer connectors slide clamp, luer connectors small volume, slide clamp,
luer connnectors
NLF2E
0.9 mm ID microbore tubing,
slide clamp, luer connectors
NLF2NTE
Luer connectors, without tubing
Packaging 50 units per case 50 units per case 50 units per case
Volume 2.3 mL 12 mL NLF1E
0.5 mL
NLF2E
0.8 mL
NLF2NTE
0.7 mL
Membrane 1.2 µm Polyamide membrane 1.2 µm Supor membrane 1.2 µm Supor membrane
Filter and tubing Non-phthalate fluid pathway, Non-phthalate fluid pathway, Non-phthalate fluid pathway,
free of latex free of latex free of latex
Special features Air elimination Air elimination Air elimination
Maximum filter life 24 h 24 h 24 h
Information for use Single patient use Single patient use Single patient use
www.pall.com/medical 15
Pharmacy Filtration Devices
Product name Pall PharmAssure® Syringe Filter Pall PharmAssure 25 mm Hydrophobic Pall PharmAssure Dispensing Pin
Vent Filter
Product description Syringe filter for drug preparation and Vent filter for sterile venting of sterile Spike for sterile venting of drug
intravenous, epidural and subcutaneous drug containers containers when sampling fluids and
syringe bolus drug administration for the retention of pharmaceutical dust
– Low protein binding and aerosols from the venting system
– Extensive drug compatibility
Order code I Description 25 mm (HP1002, HP1004, HP1008, HP2002 HP2402
HP1012, HP1050)
32 mm (HP4642, HP4644, HP4648,
HP4640)
Packaging 50 units per case 50 units per case 50 units per case
Membrane | Pore size HP1002, HP4642 0.2 µm hydrophobic acrylic copolymer 0.2 µm hydrophobic venting
0.2 µm Supor membrane membrane
HP1004, HP4644
0.45 µm Supor membrane
HP1008
0.8 µm Supor membrane
HP1012, HP4648
1.2 µm Supor membrane
HP1050, HP4640
5.0 µm Supor membrane
Housing Acrylic Acrylic Acrylic
Housing diameter 25 mm (HP1002, HP1004, HP1008, 25 mm n/a
HP1012, HP1050)
32 mm (HP4642, HP4644, HP4648,
HP4640)
Connectors Luer connectors (m/f) Luer connectors (m/f) Luer connector (f)
Dual lumen male spike
Membrane area 2.8 cm2 (HP1002, HP1004, HP1008, 2.8 cm2 1.0 cm2
HP1012, HP1050)
5.3 cm2 (HP4642, HP4644, HP4648,
HP4640)
Volume <0.85 mL (HP1002, HP1004, HP1008, n/a n/a
HP1012)
<1.0 mL (HP4642, HP4644, HP4648,
HP4640, HP1050)
Free of latex Yes Yes Yes
www.pall.com/medical 16
Breathing System Filters
Product name Pall Ultipor™ 25 Breathing System Filter Pall Ultipor 100 Breathing System Filter
Product description Breathing system filter for anaesthesia – also suitable for Breathing system filter for anaesthesia and
low tidal volumes intensive ventilation
Order code I Description BB25 BB2000APN BB100E
With monitoring port With monitoring port, expandable BB100ES
BB25G catheter mount (with two straight Sterile
With monitoring port (bulk pack) connectors), and fixed non-ported BB100EF
BB25S elbow With flex tube and flex tube cap
With monitoring port, sterile BB25D BB100EFS
BB25GS With monitoring port, flex tube With flex tube and flex tube cap, sterile
With monitoring port, sterile and fixed non-ported elbow BB100P
(bulk pack) BB25DG With monitoring port
BB25F With monitoring port, flex tube BB100PS
With monitoring port, flex tube and fixed non-ported elbow (bulk With monitoring port, sterile
and flex tube cap pack) BB100PF
BB25FG BB25Y With monitoring port, flex tube and flex tube cap
With monitoring port, flex tube With monitoring port, and catheter BB100PFS
and flex tube cap (bulk pack) mount (with straight connector at With monitoring port, flex tube and flex tube cap, sterile
BB25FS the filter end and fixed elbow, with
With monitoring port, flex tube access port and cap, at the
and flex tube cap, sterile patient end)
BB25FU BB25CG
With monitoring port and flex tube With monitoring port and catheter
BB25FGU mount (with straight connector at
With monitoring port and flex tube the filter end and fixed, non-port-
(bulk pack) ed elbow connector at the patient
BB2000AP end). (bulk pack)
With monitoring port, expandable BB25N
catheter mount (with two straight With monitoring port and fixed,
connectors) and catheter mount cap non-ported elbow
BB2000APS BB25NG
With monitoring port, expandable With monitoring port and fixed,
catheter mount (with two straight non-ported elbow (bulk pack)
connectors) and catheter mount
cap, sterile
Packaging 50 units per case (BB25, BB25S, BB25F, BB25FS, BB25FU, 50 units per case
BB2000AP, BB2000APS, BB2000APN, BB25D, BB25Y, BB25N)
Bulk pack 200 units per case (BB25DG, BB25CG) -
250 units per case (BB25G, BB25FG, BB25FGU, BB25NG)
300 units per case (BB25GS)
Filter media Hydrophobic media manufactured using silicone resin Composite media comprised, on the patient side, of a
bonded man-made mineral fibres hydrophobic layer manufactured using silicone resin
bonded man-made mineral fibres and, on the machine
side, an integral hydrophilic cellulose layer
Filter volume 35 mL 85 mL
Filtration efficiency for 100% 100%
liquidborne bacteria/viruses
Filtration efficiency for >99.999% ≥99.999%
airborne bacteria/viruses
Resistance @ 30 L/min Approx. 1.5 cm H2O Approx. 1 cm H2O
Resistance @ 60 L/min Approx. 3.5 cm H2O Approx. 2 cm H2O
Filter ISO connectors Patient end 15 mm female / 22 mm male Patient end 15 mm female / 22 mm male
Machine end 22 mm female / 15 mm male Machine end 22 mm female
Weight 26 g 47 g
Recommended use Patient end use only, max. 24 h, single patient use Patient end use only, max 24 h if nebulisation is used, use may
be extended to a maximum of 48 hours when nebulisation is not
used, single patient use
Free of latex Yes Yes
www.pall.com/medical 17
Breathing System Filters (continued)
Product name Pall Breathing System Filter Pall BB50 Breathing System and Gas Line Filters
Product description Breathing system filter for anaesthesia Machine end breathing system and gas line filters
Order code I Description BB22-15 BB50TE
BB22-15G Machine end applications in breathing systems and
(bulk pack) gas line applications
BB22-15S BB50TBL
Sterile Gas line applications
BB22-15F BB50TES
With flex tube and flex tube cap For machine end applications in breathing systems and
BB22-15M gas line applications (e.g., insufflation), sterile
With monitoring port BB50TESD
BB22-15MG BB50TES in double pouch
With monitoring port (bulk pack) BB50TP
BB22-15MS As per BB50TE applications but also for use with
With monitoring port, sterile Puritan Bennett oxygen concentrators
BB22-15MF
With monitoring port, flex tube and flex tube cap
BB22-15MFS
With monitoring port, flex tube and flex tube cap, sterile
Packaging 50 units per case 25 units per case (BB50TESD)
50 units per case (BB50TE, BB50TTBL,
BB50TES, BB50TP)
Bulk pack 250 units per case -
Filter media Hydrophobic media manufactured using silicone resin Hydrophobic media manufactured using silicone resin
bonded man-made mineral fibres bonded man-made mineral fibres
Filter volume Approx. 90 mL Approx. 90 mL
Filtration efficiency for 100% 100%
liquidborne bacteria/viruses
Filtration efficiency for >99.999% >99.999%
airborne bacteria/viruses
Resistance @ 30 L/min Approx. 1 cm H2O Approx. 1 cm H2O
Resistance @ 60 L/min Approx. 2.5 cm H2O Approx. 2 cm H2O
Filter ISO connectors Patient end 15 mm female / 22 mm male Patient end 22 mm male
Machine end 22 mm female / 15 mm male Machine end 22 mm female
Weight 43 g 39 g
Recommended use Max. 24 h single patient use BB50TE, BB50TP, BB50TES, BB50TESD: Max. 24 h –
in connection with a high-efficiency HME (heat and
moisture exchanger) extended use may be permitted
Free of latex Yes Yes
www.pall.com/medical 18
Lung Function Diagnostic Filters
Product name Pall Pro-Tec® Filter for Pulmonary Function Testing Pall Pro-Tec Filter Kit for Pulmonary Function Testing
Product description Filter for lung function diagnostics Filter kit for lung function diagnostics
Order code I Description PF30S PF30KIT1
30 mm female connector PF30S including mouthpiece and nose clip
PF30SG PF30KIT2
30 mm female connector (bulk pack) PF30SJE including hard plastic mouthpiece
PF30SJE PF30KIT3
Modified 30 mm female connector PF30SJE including mouthpiece and nose clip
PF30SJG
Modified 30 mm female connector (bulk pack)
Packaging 25 units per case 25 units per case
Bulk pack 250 units per case -
Filter media Polypropylene Polypropylene
Filter volume Approx. 40 mL Approx. 40 mL
Cross contamination 99.9999% 99.9999%
reduction efficiency
Resistance @ 12 L/sec 0.6 cm H2O 0.6 cm H2O
Connectors 30 mm female or 30 mm modified female depending 30 mm female or 30 mm modified female depending
upon variant upon variant
Weight 26 g 26 g
Recommended use Single patient use Single patient use
Free of latex Yes Yes
www.pall.com/medical 19
Minimally Invasive Surgery Filters
Product name Pall Insufflator Gas Line Filter High flow insufflation set with high Pall LaparoShield® Laparoscopic
efficiency hydrophobic Pall gas filter Smoke Filtration System
Product description Filter set for insufflation gases Insufflator filter set for high flow Filtration system for smoke generated
applications during laparoscopic surgery
Order code I Description IGF1 FRIGF2 LSF1
7.5 cm silicone tubing and luer 3 m PVC tubing, sterile double Approximately 45 cm PVC tubing
connector inlet (f), peel-pouch and clamp, male luer connector
52.5 cm silicone tubing and luer with rotating collar, sterile double
connector outlet (m), sterile double peel-pouch
peel-pouch LSF2
IGF1E Male luer connector with rotating
7.5 cm PVC tubing and luer connector collar, sterile double peel-pouch
inlet (f), 52.5 cm PVC tubing and
luer connector outlet (m), sterile
double peel-pouch
IGF1L
7.5 cm PVC tubing and luer connector
inlet (f), 250 cm PVC tubing and luer
connector outlet (m), sterile double
peel-pouch
IGF1M
7.5 cm PVC tubing and luer connector
inlet (m), 250 cm PVC tubing and
luer connector outlet (f), sterile
single peel-pouch
IGF1C
7.5 cm PVC tubing and suction
connector inlet (f), 250 cm PVC tubing
and luer connector outlet (m), sterile
single peel-pouch
IGF1CD
7.5 cm PVC tubing and suction
connector inlet (f), 250 cm PVC tubing
and luer connector outlet (m), sterile
double peel-pouch
IGF1K
10 cm silicone tubing and luer
connector inlet (f), 10 cm silicone
tubing and luer connector outlet (m),
10 cm silicone tubing, sterile single
peel-pouch
Packaging 20 units per case 20 units per case 10 units per case
Filter media Hydrophobic media manufactured PTFE Pre-filtration layers - glass fibre,
using silicone resin bonded man-made polyester, acrylic; Membrane layers -
mineral fibres polytetrafluoroethylene (PTFE).
Chemical absorbant layers - activated
carbon; Film layers - ethylene vinyl
acetate (EVA)
Housing Acrylic Acrylic Polyester
Tubing PVC or silicone depending upon PVC PVC, EVA
variant
Bacteria filtration efficiency >99.999% >99.9999% with test organism >99.999% with test organism
(airborne) Brevundimonas diminuta Brevundimonas diminuta
Viral filtration efficiency for >99.99% >99.999% with test organism >99.999% with test organism
viruses (airborne) Bacteriophage MS-2 Bacteriophage MS-2
www.pall.com/medical 20
Medical Gas Filters
Product name Pall Oxygenator Gas Line Filter Pall Gas Line Filter
Product description Bacteria, viral and particulate removal filter for Bacteria, viral and particulate removal filter for
medical gases medical gases
Order code I Description ORO1H BRO1
1/4 in. – tubing connections ⅛ in. – 3/16 in. – tubing connections
BRO12
⅛ in. – tubing connections
BRO18
3/16 in. – tubing connections
BRO18T
3/16 in. – tubing connection, 7.5 cm silicone tubing
BRO9T
3/16 in. – tubing connection, 7.5 cm silicone tubing
BRO25
¼ in. - 3/8 in. – tubing connections
Packaging 40 units per case 40 units per case
(BRO9T 100 units per case)
Filter membrane Hydrophobic media manufactured using silicone resin Hydrophobic media manufactured using silicone resin
bonded man-made mineral fibres bonded man-made mineral fibres
(BRO9T Acrylic co-polymer/Nylon)
Housing Acrylic BRO1
Acrylic
BRO12
Polypropylene
BRO18
Polypropylene
BRO18T
Polypropylene
BRO9T
Acrylic
BRO25
Polypropylene
Tubing n/a BRO9T, BRO18T Silcone
Bacteria filtration efficiency >99.999% >99.999%
(airborne) (except BRO9T)
Viral filtration efficiency for >99.99% >99.999%
viruses (airborne) (except BRO9T)
www.pall.com/medical 21
Visit us on the Web at www.pall.com/medical
(866) 347-3428 phone The information provided in this literature was reviewed for accuracy at the time of publication. Product data may
be subject to change without notice. For current information consult your local Pall distributor or contact Pall directly.
[email protected] email
Part numbers quoted are protected by the Copyright of Pall Europe Ltd.