Xvive U4 Manual
Xvive U4 Manual
INEAR MONITOR
WIRELESS SYSTEM
CAUTION This Class B digital apparatus complies with Canadian
ICES-003.
RISK OF ELECTRIC SHOCK
DO NOT OPEN IC Caution: RSS-Gen Issue 4 December "&"CNR-Gen 4e
Décembre:
WARNING : TO REDUCE THE RISK OF FIRE OR ELECTRIC This device contains licence-exempt transmitter(s)/receiv-
SHOCK: DO NOT REMOVE SCREWS. er(s) that comply with Innovation, Science and Economic
NO USER-SERVICEABLE PARTSINSIDE. Development Canada’s licence-exempt RSS(s). Operation
REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. is subject to the following two conditions:
1. This device may not cause interference.
WARNING : TO REDUCE THE RISK OF FIRE OR ELECTRIC 2. This device must accept any interference, including
SHOCK, DO NOT EXPOSE THE APPLIANCE TO RAIN OR interference that may cause undesired operation of the
MOISTURE. device.
THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. reasonable protection against harmful interference in a
OPERATION IS SUBJECT TO THE FOLLOWING TWO residential installation. This equipment generates, uses
CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARMFUL and can radiate radio frequency energy and, if not
INTERFERENCE, AND (2) THIS DEVICE MUST ACCEPT ANY installed and used in accordance with the instructions,
INTERFERENCE RECEIVED, INCLUDING INTERFERENCE may cause harmful interference to radio communications.
THAT MAY CAUSE UNDESIRED OPERATION. There is no guarantee that interference will not occur in a
particular installation. If this equipment does cause
WARNING: harmful interference to radio or television reception,
Changes or modifications not expressly approved in which can be determined by turning the equipment off
writing by Xvive may void the users authority to operate and on, the user is encouraged to try to correct the
this equipment. interference by one or more of the following
1. Observe all instructions carefully in the U4 set manual. 3. Do not place near heat sources, such as radiators, heat
2. Do not to perform service operations beyond those registers, or appliances which produce heat.
described in the U4 set manual. Services required when 4. Guard against objects or liquids entering the device.
the apparatus has been damaged in any way, such as: Do not use or place unit near water.
• Liquid has been spilled or objects have fallen into the 5. Clean only with a dry cloth.
apparatus 6. Only use attachments/accessories specified by the
• The unit has been exposed to rain or moisture manufacturer.
• The unit does not operate normally or changes in 7. Prolonged listening at high volume levels may cause
performance in a significant way irreparable hearing loss and/or damage. Always be sure
• The unit is dropped or the enclosure is damaged to practice “safe listening.”
03
WARNING U4 SET PRODUCT INTRODUCTION
LISTENING TO AUDIO AT EXCESSIVE VOLUMES CAN U4 person wireless monitoring system provides better
CAUSE PERMANENT HEARING DAMAGE. USE AS LOW sound feedback for stage performers and performance
A VOLUME AS POSSIBLE. quality. As a portable wireless system, you don't need to
set up. Just plug-and-play to quickly build your monitor-
Over exposure to excessive sound levels can damage
ing system.
your ears resulting in permanent noise-induced
hearing loss. Do not use earphones for a long time FEATURES:
and set the volume below 70% or lower. • 2.4Ghz wireless In-ear monitor system
• Solid RF connection over a 90 feet range(actual range
depends on RF signal absorption, reflection and
interference)
PACKAGE DETAILS • Up to 107 dB signal-to-noise ratio provides clear, detailed
audio at any volume.
• High Resolution 24-bit/48kbps audio
U4 Transmitter 1PCS • Broad 20Hz-20KHz frequency response
U4 Receiver 1PCS • Dynamic Rang 107 dB
USB Cable 1PCS • Less than 5ms Latency, Simultaneous broadcasts on 6
channels.
XLR Male to 1/4" TS Male Adapter 1PCS • 5 Hours of battery life ( rechargeable battery for both
Manual 1PCS Transmitter & Receiver )
Bag 1PCS • Provides smooth frequency response with any headphones
• Mono balanced XLR or mono unbalanced TS input
04
BASIC OPERATION
U4 TRANSMITTER
OFF
ON Connect to
OR
the socket
POWER ON
* Always store U4 at CHARGING TIMES BATTERY LIFE
POWER ON room temperature
0:15 30 min
* When storing the unit,
please check the 0:30 1 hours
battery state regularly 1:00 2 hours
and charge if necessary. 2:30 5 hours
POWER ON
Start the power switch,
the channel indicator
will light up.
Connect
Power
07
CHANNEL SWITCH
1
PAIR TRANSMITTER AND RECEIVER
2
5
3
4
MAX. 6 CHANNELS
08
QUICK START
VOLUME ADJUSTING
LISTENING TO AUDIO AT EXCESSIVE VOLUMES CAN CAUSE
PERMANENT HEARING DAMAGE. USE AS LOW A VOLUME
AS POSSIBLE.
09
OPERATION
10
OPERATION
MIAN OUTPUT
11
OPERATION
CHANNEL 1
MULTIPLE TRANSMITTER
AND MULTIPLE RECEIVERS
CHANNEL 2
12
2.4 GHz SPECTRUM OVERVIEW AND INTERFERENCE
U4 operates within the 2.4GHz ISM band which is utilized 2.4Ghz Frequency Tables
by Wi-Fi, Bluetooth, and other wireless devices. 2.4GHz is
an open band and, as such, does not require a license to CHANNEL 1 2402MHz, 2480MHz, 2482MHz
be used worldwide. CHANNEL 2 2408MHz, 2472MHz, 2474MHz
CHANNEL 3 2416MHz, 2464MHz, 2466MHz
Tips and Methods to Improve Wireless System Performance
1) Keep more than 3 meteres distance between Receiver CHANNEL 4 2434MHz, 2440MHz, 2442MHz
unit and other WiFi transmitters such as routers.
CHANNEL 5 2427MHz, 2448MHz, 2450MHz
2) Change channels to avoid interference with other WiFi
products. CHANNEL 6 2422MHz, 2456MHz, 2458MHz
3) In case of environmental interference from other WiFi
systems, shorten the distance between the receiver * U2 1~4 channels are the same as U3/U3C/U4 1~4 channels,
and transmitter units. U2, U3/U3C and U4 use in sametime max is 6 sets.
13
TROUBLESHOOTING
ISSUE SOLUTION
• Check that the U4 Receiver's RF LED is lit.
• Check whether the device has a signal sent to the transmitter
• Check that the power switch is turned on for both the Transmitter and
No Sound the Receiver.
• Ensure that the U4 Transmitter and Receiver are on the same channel.
• The Receiver can be paired with one Transmitter at a time
• Check the Line/Aux setting at the transmitter and verify that the meter is not
reaching the overload
Distorted Audio • Check Levels going in and out of the mixer. Verify that no distortion occurs in
each audio signal.
• Check receiver headphone output Volume level
Low audio output at the receiver • Check Transmitter mode Line/Aux.
• Check Check whether the device has enough signals level to the transmitter.
Signal instability: RF LED flickering • See, “Tips and methods to improve wireless system performance page 13
Unable to switch the channel • The channel switch locks after 15 seconds. Double-click the channel button
to unlock and reset.
Multiple connect • Use one transmitter can connect with more than 2 receivers.
14
SPECIFICATIONS
15
U4 TRANSMITTER U4 RECEIVER
Dimensions 30 X 28 X 100 mm 47 X 41 X 60 mm
Weight 90g 118g
Housing Molded plastic and cast metal Molded plastic and cast metal
Battery 3.7V Rechargeable Li-ion, 860mAh 3.7V Rechargeable Li-ion, 1200mAh
Impedance Input 47kΩ1KHz 6-600Ω
Audio input Connector Balanced XLR Male input
Audio output Connector 3.5mm stereo output
Aux mode: -10dBV | Max. +12.2dBu
Mode
Line mode: +4dBu | Max. +22dBu
Battery life Up to 5 Hours Up to 5 Hours
Antennal Impedance 50Ω 50Ω
ANTENNA Type 1/4 Wave Sleeve Dipole, Non-removable 1/4 Wave Sleeve Dipole, Non-removable
Number Of Antenna 1 2
16
U4 SERIES
U4 SET U4R2
17
WIRELESS INEAR MONITOR SYSTEM
U4R4 U4T
U4R
1 RECEIVER
18
PATENT PENDING
2nd floor, Building 12, Xicheng Industrial Area, Xixiang Town,
Baoan District, Shenzhen Guangdong China. 518101
E-mail: [email protected]