0% found this document useful (0 votes)
26 views6 pages

STRUCTURAL

The document is a structural plan created by Johara Brynn Panganiban for a building design, dated January 23, 2025. It includes detailed specifications for footings, beams, columns, and trusses, along with reinforcement details and structural notes regarding material strengths and construction guidelines. The plan emphasizes the importance of consulting an engineer for any modifications and provides measurements and arrangements for various structural elements.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
26 views6 pages

STRUCTURAL

The document is a structural plan created by Johara Brynn Panganiban for a building design, dated January 23, 2025. It includes detailed specifications for footings, beams, columns, and trusses, along with reinforcement details and structural notes regarding material strengths and construction guidelines. The plan emphasizes the importance of consulting an engineer for any modifications and provides measurements and arrangements for various structural elements.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 6

N.G.L.

10880,4286

8704,3429
10 mm ∅ TIES SP. @ 2- 50mm
4- 75mm, 6- 100mm, REST @
200mm O.C. 2176.09

453.35

1813,4048
FOOTING 1 8704,3429
5 - 15 mm ∅ BARS B.W.
2176.09

F1

N.G.L.

7253,619
10880,4286 10 mm ∅ TIES SP. @ 2- 50mm
4- 75mm, 6- 100mm, REST @
1813.40

200mm O.C.
2720.11

453.35

7253,619 1813.40
1813,4048

FOOTING 2 F2
6 - 15 mm ∅ BARS B.W.

DETAIL OF
COLUMN FOOTINGS
SCALE 1 : 25 m.

NAME: TITLE: DATE: PLATE # GRADE:


JOHARA BRYNN PANGANIBAN STRUCTURAL PLAN JAN. 23, 2025
STUDENT# & YEAR-SECTION BUILDING SYSTEM INSTRUCTOR:
202200887 3-1 DESIGN ENGR. LARRY ROCELA
10mm ∅ HORIZONTAL BARS
@ EVERY 3 LAYERS

422.14

331.68

5" THK CHB (EXTERIOR)


5" THK CHB (EXTERIOR)
3" THK CHB (INTERIOR) 6 EQUAL PARTS = 6.30 m 105.53 3 EQUAL PARTS = 3.58m 105.53

3429.85 1991.95

N.G.L.
TRUSS 1 TRUSS 1

469.77 469.77

587.21 587.21
NOTE:

USE THE FOLLOWING:


341.21

340.47
· 2 - 2" x 2" x .25" ANGULAR BAR FOR TOP CHORDS
117.44 117.44

· 2 - 2" x 2" x .25" ANGULAR BAR FOR BOTTOM CHORDS


· 2 - 2" x 2" x .25" ANGULAR BAR FOR KING POSTS
· 2 - 1.5" x 1.5" x 1.5" ANGULAR BAR FOR WEB MEMBERS
4 EQUAL PARTS = 4.68 m 105.53 2 EQUAL PARTS = 2.25 m 105.53

· 2" x 4" x 1.5mm CEE PURLINS


2572.39 1292.79

469.77 469.77

TRUSS 1 TRUSS 1

NOTE: PROVIDE 50mm THK.


WF1 GRAVEL FILLING WF2 DETAIL OF TRUSSES
SCALE 1 : 20 m.

2 - 10mm ∅ HORIZ. BARS W/ 10mm∅


TRANSVERSE BARS @ EVERY .3m O.C.
USE # 16 G.I. TIE WIRE

DETAIL OF
WALLFOOTINGS
SCALE 1 : 20 m. 12MM Ø
SAGROD
PRE-PAINTED
2"X4" C-PURLINS
ROOFING
END COVER

PRE-PAINTED G.I.
RIDGE ROLL PRE-PAINTED END
OVERLAP
REVITED WALL FLASHING

END COVER

2"X7" C-PURLINS
FASCIA BOARD

PRE-PAINTED GUTTER

OVERLAP

25mm x 25mm x 4mm PRE-PAINTED


WALL ANGLE GUTTER
CUT FOR RIB
600mm x 1200mm x
4.5mm PLAIN FIBER 3"Ø DOWNSPOUT
CEMENT BOARD
PRE-PAINTED G.I. RIDGE ROLL

ISOMETRIC CONNECTION (RIDGE ROLL & GUTTER)

2 ROOF FRAMING DETAILED SECTION


S 6 SCALE 1: 25 MTS.

NAME: TITLE: DATE: PLATE # GRADE:


JOHARA BRYNN PANGANIBAN STRUCTURAL PLAN JAN. 23, 2025
STUDENT# & YEAR-SECTION BUILDING SYSTEM INSTRUCTOR:
202200887 3-1 DESIGN ENGR. LARRY ROCELA
SUPPORT MID-SPAN BAR ARRANGEMENT
BEAM DIMENSION REMARKS REMARKS
TOP BOTTOM TOP BOTTOM SUPPORT MID-SPAN

10MM ∅ STIRRUPS USE 2-10 mm ∅


B-1 200mm X 300mm 3-16 mm ∅ 2-16 mm ∅ 3-16 mm ∅ 2-16 mm ∅ 4 @0.05, 6 @0.075 STIFFENER
8 @0.10, REST@ 0.15 O.C. BARS

B2 200mm X 300mm 3-16 mm ∅ 3-16 mm ∅ 3-16 mm ∅ 3-16 mm ∅ - DO - - DO -

STRUCTURAL NOTES

MINIMUM CONCRETE COMPRESSIVE STRENGTH: B-3 250mm X 300mm 3-20 mm ∅ 3-20 mm ∅ 3-20 mm ∅ 3-20 mm ∅ - DO - - DO -
2500 PSI FOR ALL COLUMN, FOOTINGS, FLOORING,
2500 PSI FOR ALL WALL FOOTINGS, SLAB ON FILL

YIELD STRENGTH OF STEEL REINFORCEMENT:


RB 200mm X 300mm 3-16 mm ∅ 2-16 mm ∅ 2-16 mm ∅ 3-16 mm ∅ - DO - - DO -
2500 PSI FOR 12MMØ AND BELOW

COLUMN FOOTINGS HAVE BEEN DESIGNED BASED


ON SOIL BEARING CAPACITY OF 3000 PSF
IF ACTUAL SOIL BEARING CAPACITY IS LOWER THAN
3000 PFS, IT MUST BE REPORTED IN WRITING TO THE
ENGINEER FOR PROPER EVALUATION & ACTION. SCHEDULE OF BEAMS
ALL MEASUREMENTS ARE IN METERS
UNLESS OTHERWISE INDICATED.

ANY ACTION OR MODIFICATION OF STRUCTURAL MEMBERS


SUCH AS COLUMNS AND BEAMS SHOULD BE CONSULTED
TO THE ENGINEER FOR PROPER GUIDANCE.

ANY REVISION SHOULD BE NOTIFIED TO THE ENGINEER. REINFORCEMENT


COLUMN DIMENSION LATERAL TIES
VERTICAL BARS ARRANGEMENT

6 - 16 mm ∅ 10mm Ø TIES @ 2-50mm, 4-75mm,


C-1 200mm X 300mm 6-100mm, REST @ 200mm O.C.

4 - 16 mm ∅ 10mm Ø TIES @ 2-50mm, 4-75mm,


C-2 200mm X 300mm 6-100mm, REST @ 200mm O.C.
2 - 12 mm ∅

SCHEDULE OF COLUMNS

NAME: TITLE: DATE: PLATE # GRADE:


JOHARA BRYNN PANGANIBAN STRUCTURAL PLAN JAN. 23, 2025
STUDENT# & YEAR-SECTION BUILDING SYSTEM INSTRUCTOR:
202200887 3-1 DESIGN ENGR. LARRY ROCELA
A B C C' D D' E F

1459,313
4062,3203
37784,817

6092,0042 6641,6391 8719,5294 8090,1841 8241,4603

WF 2 WF 2 WF 2 WF 2 WF 2
C2 F2
1
C2 F2 WF 1 C2 F2
C2 F2 C1 F1 C2 F2
2

9074,9862
WF 1

WF 2
WF 1 WF 1 WF 1 C2 F2 WF 1
WF 1
WF 1
3 C2 F2
C2 F2 WF 1 C2 F2
4 100 mm THK. SLAB ON FILL

5450,8202
W/ 10 mm Ø BAR SPACED C2 F2

3913,0274
WF 2
WF 1 @ 0.40 m O.C.B.W
WF 1
WF 1 C2 F2 WF 1
5 C2 F2 WF 1
C2 F2 C2 F2
6 C2 F2
4342,6701
WF 1
5034,7619

7
8
C2 F2 C2 F2

2405,1771
12771,1431

2494,555
5553,238 6670,0813 5453,7819
4426,6122 7195,0791

2662,8061
FOUNDATION PLAN
SCALE 1 : 100 m.

NAME: TITLE: DATE: PLATE # GRADE:


JOHARA BRYNN PANGANIBAN STRUCTURAL PLAN JAN. 23, 2025
STUDENT# & YEAR-SECTION BUILDING SYSTEM INSTRUCTOR:
202200887 3-1 DESIGN ENGR. LARRY ROCELA
APEX OF CONC. TRUSS
BEAM

TOP OF ROOF BEAM

SLAB WALL
N L
PA
TS 4

W
4
OR )

LO
SH (W CANOPY

N
G (L)
SP
AN
4
12mm ∅ TRANSVERSE BAR
W

SPACED @ 200mm O.C.


10mm ∅ LONGITUDINAL BAR
L SPACED @ 250mm O.C.
4
BEAM
TOP OF 2ND FLR. SLAB
98.08

TOP OF FLOOR BEAM


BEAM

VARIABLE

VERIFY

WALL

12MM ∅ @ 150MM O.C. B.W.


2 OUT OF 3 ALTERNATE
NOTE:
BENT UP/STRAIGHT BAR 4" THK. SLAB ON FILL FINISH FLOOR LINE
SLAB THICKNESS = 100 mm.
NAT. GRND. LINE
WINDOW
10MM ∅ TEMPERATURE BARS @ 250MM O.C. B.W.
THROUGHOUT THE COLUMN STRIP

DETAIL OF SPOT DETAIL OF


SLAB REINFORCEMENT CANOPY TO BEAM CONNECTION
N.T.S. SCALE 1 : 10 m.

5 TYPICAL COLUMN AND BEAM CONNECTION


S 5 SCALE 1: 50 MTS.

NAME: TITLE: DATE: PLATE # GRADE:


JOHARA BRYNN PANGANIBAN STRUCTURAL PLAN JAN. 23, 2025
STUDENT# & YEAR-SECTION BUILDING SYSTEM INSTRUCTOR:
202200887 3-1 DESIGN ENGR. LARRY ROCELA
BUILDING LINE

BUILDING LINE PROPERTY LINE


ROAD
0.10-0.15m Lot level from FFL
PROPERTY LINE
ROAD FFL
0.10-0.15m Lot level from FFL
NGL
FFL CHB FRE
1.5 %
Gutter
NGL

CHB FRE
1.5 % FOOTING TIE BEAM
Gutter

FOOTING TIE BEAM

Column Extension
Note:
Block Elevation must be
Note: equal to the Gutter elevation.
Block Elevation must be

Depth
(BLOCK IS WELL PREPARED AND BLOCK ELEVATION
equal to the Gutter elevation. IS CORRECT, BUT AFTER 1.05M DEPTH OF EXCAVATION,
IT DOESN'T REACH THE HARD STRATA YET.
STANDARD DESIGN FOR FFL ELEVATION
CASE 1. EXTENDED COLUMN

BUILDING LINE
BUILDING LINE

PROPERTY LINE
PROPERTY LINE
ROAD
0.10-0.15m Lot level from FFL
Additional Height ROAD
for Backfill
FFL
FFL
NGL

CHB FRE
1.5 %
CHB NGL FRE 1.5 %
Gutter
Gutter
FOOTING TIE BEAM
FOOTING TIE BEAM

(BLOCK ELEVATION IS LOWER THAN THE GUTTER


IN CASES WHEREIN BLOCK ELEVATION IS
HIGHER THAN THE GUTTER, THEN JUST OFFSET AND FOLLOW
CASE 2. BACKFILLING STILL SAME PROCEDURE. (FFL WILL BE MORE
THAN 0.40M HIGHER THAT THE ROAD ELEVATION)

3 DETAIL OF FINISH FLOOR LINE


S 6 NOT TO SCALE

NAME: TITLE: DATE: PLATE # GRADE:


JOHARA BRYNN PANGANIBAN STRUCTURAL PLAN JAN. 23, 2025
STUDENT# & YEAR-SECTION BUILDING SYSTEM INSTRUCTOR:
202200887 3-1 DESIGN ENGR. LARRY ROCELA

You might also like