MasterInject® 1315 is a two-component low-viscosity epoxy resin system designed for sealing static concrete cracks ranging from 100 microns to 9mm. It offers excellent chemical resistance, high compressive strength, and deep penetration into narrow cracks, making it suitable for various structural repairs. Proper safety precautions and storage conditions are recommended to ensure effective use and longevity of the product.

Uploaded by

Kushal Ghosh
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
90 views2 pages

MasterInject 1315

MasterInject® 1315 is a two-component low-viscosity epoxy resin system designed for sealing static concrete cracks ranging from 100 microns to 9mm. It offers excellent chemical resistance, high compressive strength, and deep penetration into narrow cracks, making it suitable for various structural repairs. Proper safety precautions and storage conditions are recommended to ensure effective use and longevity of the product.

Uploaded by

Kushal Ghosh
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

MasterInject® 1315

Two component system based on low-viscosity epoxy resins

DESCRIPTION CHEMICAL RESISTANCE


A two component system based on low-viscosity MasterInject 1315 Low Viscosity injection resin (in
epoxy resins. Ideal for sealing static cracks from a fully cured state) has excellent resistance to
widths greater than 100 microns but no more than most aqueous substances and liquids. These
9mm. It is highly penetrative and cures to form a include:
permanent and rigid seal against the ingress of  Sea water
corrosive fluids and gases and is capable of  Brackish water
restoring structural integrity to concrete elements.  Effluent and raw sewage
 Acids of low concentration
TYPICAL APPLICATIONS  Alkalis
Repair and sealing of “static” concrete cracks. The  Oils (mineral and organic)
injection resin can be used to fill and bond dormant
cracks in: PACKAGING: 1 LITRE KIT
MasterInject 1315
 Columns Base Resin: 0.852kg bottle
 Bridge decks
 Floors MasterInject 1315
 Piers Reactor Resin: 0.213kg bottle
 Abutments
 Tunnels SPECIFICATION CLAUSE
 Basements All cracks and voids, where indicated shall be
 Beams injected with MasterInject 1315 injection resin
 Underpasses (specify) as manufactured by BASF Dubai, or
similar approved. The appropriate material shall
ADVANTAGES be mixed and placed in accordance with the
 Has a low viscosity and will penetrate deeply manufacturer's recommendations.
into very narrow cracks and cavities.
 MasterInject 1315 injection resin has superior A BASF technical representative or approved
adhesion to dry surfaces. applicator should be consulted to assist with on-
 MasterInject 1315 will enable a structural site recommendations etc.
repair to be effected and offers high
compressive strength. Can be used as a fluid
grout up to thicknesses of 9mm.
 MasterInject 1315 (once fully cured) will resist
hydrostatic pressure and block penetration of
deleterious substances.
MasterInject® 1315

PHYSICAL AND TECHNICAL PROPERTIES* SAFETY PRECAUTIONS


As with all chemical products, care should be
Colour Water Clear taken during use and storage to avoid contact with
Composition 2 part solvent free eyes mouth, skin and foodstuffs (which can also be
epoxy resin tainted with vapour until product fully cured or
Specific gravity of mixed 1.05 kg/l dried). Treat splashes to eyes and skin
material ASTM D1475 immediately. If accidentally ingested, seek
Viscosity ASTM D2196 204 mPa.s immediate medical attention. Keep away from
Pot life*1 ASTM D2471 53 mins 25°C children and animals. Reseal containers after use.
30 mins 40°C
Service temp. range -20°C to +60°C NOTE
Slant Shear Bond Strength 30N/mm² at 14 days Field service, where provided, does not constitute
ASTM C-882 : 1990 supervisory responsibility. For additional
Compressive strength >70N/mm² at 7 days information contact your local BASF
ASTM D695 representative.
Tensile strength ASTM D638 >25N/mm² at 7 days
Flexural strength >70N/mm² at 7 days BASF reserves the right to have the true cause of
DIN EN ISO 178 any difficulty determined by accepted test
*Properties listed are based on laboratory controlled methods.
tests.
*1Note: Pot life will vary depending on storage and site
conditions. QUALITY AND CARE
All products originating from BASF’s Dubai, UAE
INSTALLATION PROCEDURES facility are manufactured under a management
Please refer to the BASF Guide to Injection for system independently certified to conform to the
the full installation details and options relevant to requirements of the quality, environmental and
this product. occupational health & safety standards ISO 9001,
ISO 14001 and OHSAS 18001.
STORAGE
Store under cover out of direct sunlight and protect * Properties listed are based on laboratory controlled tests.
from extremes of temperature. ® = Registered trademark of the BASF-Group in many countries.
In tropical climates (ambient temperature of over
35°C) the product must be stored in an air
conditioned environment. MasterInject 1315 may
be kept in cool boxes preferably bedded in ice, to
extend the working time of the product.

BASF_CC-UAE/In_1315_02_12/v3/12_15
The technical information and application advice given in this BASF publication are based on the present state of
STATEMENT OF our best scientific and practical knowledge. As the information herein is of a general nature, no assumption can be
RESPONSIBILITY made as to a product's suitability for a particular use or application and no warranty as to its accuracy, reliability or
completeness either expressed or implied is given other than those required by law. The user is responsible for
checking the suitability of products for their intended use.

Field service where provided does not constitute supervisory responsibility. Suggestions made by BASF either
NOTE orally or in writing may be followed, modified or rejected by the owner, engineer or contractor since they, and not
BASF, are responsible for carrying out procedures appropriate to a specific application.

PT BASF Indonesia
DBS Bank
Ban Tower 27th Floor
Ciputra World 1 Jakarta
Jl. Prof.
Prof Dr. Satrio Kav. 3-5
Jakarta
Jaka 12940
Phone: +6221 29886000
Website: www.master-builders-solutions.basf.co.id