Data Sheet Model FD 260

Model FD 260 | Drying and heating chambers with forced convection


A BINDER FD series Avantgarde.Line heating oven is always used when fast drying and sterilization is required. Thanks to its fully homogeneous temperature
distribution, quick dynamics and powerful fan, this heating oven saves valuable time.

BENEFITS

• Best energy eciency on the market


• Excellent temporal and spatial temperature accuracy
• USB connection for recording data
• Temperature range up to +300 °C

Model 260

MAIN FEATURES
• Temperature range: +10 °C above ambient temperature to +300 °C • 2 chrome-plated racks
• Up to 30% lower energy consumption compared to conventional units on • Class 2 integrated independent adjustable temperature safety device
the market (DIN 12880) with visual alarm
• High temperature accuracy thanks to APT.line™ technology • Ergonomic handle design
• Forced convection • USB port for recording data
• Controller with LCD display
• Electromechanical control of the exhaust air flap

ORDERING INFORMATION

Interior volume [L] Voltage Option model Version Art.-No.


230 V 1~ ph 50/60 Hz Standard FD260-230V 9010-0309
259
240 V 1~ ph 60 Hz Standard FD260UL-240V 9010-0310

BINDER Data Sheet | As of: 16.03.2021 Page 1 / 6


Technical specifications are subject to change.
Data Sheet Model FD 260

TECHNICAL DATA

Description FD260-230V1 FD260UL-240V1


Article Number 9010-0309 9010-0310
Performance Data Temperature
Temperature range +10 °C above ambient temperature to [°C] 300 300
Temperature variation at 150 °C [± K] 1.9 1.9
Temperature fluctuation at 150 °C [± K] 0.4 0.4
Heating-up time to 150 °C [min] 19 19
Recovery time aer 30 seconds door open at 150 °C [min] 5 5
Air change data
Air change (approx.) at 100 °C [x/h] 9 9
Electrical data
Rated Voltage [V] 230 240
Power frequency [Hz] 50/60 60
Nominal power [kW] 2.3 2.5
Unit fuse [A] 12.5 16
Phase (Nominal voltage) 1~ 1~
Measures
Interior volume [L] 259 259
Net weight of the unit (empty) [kg] 84 84
Permitted load [kg] 270 270
Load per rack [kg] 40 40
Wall clearance back [mm] 160 160
Wall clearance sidewise [mm] 100 100
Internal Dimensions
Width [mm] 650 650
Height [mm] 780 780
Depth [mm] 515 515
Doors
Unit doors 1 1
Housing dimensions not incl. ttings and connections
Width net [mm] 810 810
Height net [mm] 940 940
Depth net [mm] 825 825
Environment-specic data
Energy consumption at 150 °C [Wh/h] 410 410
Sound-pressure level [dB(A)] 43 43
Fixtures
Number of shelves (std./max.) 2/8 2/8

1 All technical data is specied for unloaded units with standard equipment at an ambient temperature of +22 °C ±3 °C and a power supply voltage
fluctuation of ±10 %. The temperature data is determined to BINDER factory standard following DIN 12880, observing the recommended wall clearances
of 10 % of the height, width, and depth of the inner chamber. Technical data refers to 100 % fan speed. All indications are average values, typical for
units produced in series. We reserve the right to change technical specications at any time.

BINDER Data Sheet | As of: 16.03.2021 Page 2 / 6


Technical specifications are subject to change.
Data Sheet Model FD 260

DIMENSIONS incl. fittings and connections [mm]

OPTIONS

Designation Description * Art.-No.


le
10 mm 01 8012-1276
30 mm 01 8012-1016
50 mm 01 8012-1020
100 mm 01 8012-1027
right
10 mm 01 8012-1269
Access port with silicone
30 mm 01 8012-1015
plug
50 mm 01 8012-1019
100 mm 01 8012-1028
top
10 mm 01 8012-1263
30 mm 01 8012-1364
50 mm 01 8012-1380
100 mm 01 8012-1671
Alarm function for
Switchable acoustic alarm, with adjustable limit value on the independent temperature safety device – 8012-1636
overheating
Analog output 4-20 mA for temperature values (output not adjustable) 02 8012-1624
Calibration certificate,
for temperature; for extending the measurement in center of chamber to include another test temperature – 8012-1116
expanded
for temperature, measurement in center of chamber at specied temperature – 8012-1135

Calibration certificate, temperature measurement incl. certicate and 27 measuring points at specied temperature – 8012-1594
temperature temperature measurement incl. certicate, 15- 18 measuring points at specied temperature – 8012-1573
temperature measurement incl. certicate, 9 measuring points at specied temperature – 8012-1552
Class 3.1 independent
temperature safety with visual alarm (DIN 12880) – 8012-1643
device
Clock battery-backed – 8012-1641
Door gasket made of FKM, silicone-free – 8012-1652
Door lock lockable door handle – 8012-1665
Ethernet interface for Multi Management Soware APT-COM™ – 8012-0988
Incl. additional measures for the greatest possible impermeability to gas; not in conjunction with access port or interior
Gas-tight option model – 8012-1687
lighting option
HEPA air filter On fresh air supply for unit; lter classication H14 (acc. to. EN 1822-1:2009, > 99.995% at 0.3 µm) – 8012-1052
With gas inlet and outlet, Ø 10 mm, incl. additional measures for the greatest possible impermeability to gas; not in
Inert gas connection – 8012-1693
conjunction with access port or interior lighting option
Inner chamber,
max. total load 300 kg – 8012-1055
reinforced
with 15 W light bulb
Interior lighting
230/240 V option model – 8012-1628
Load management to comply with EMC requirements in accordance with EN 61326-1:2013-07 (IEC 61326-1:2012) – 8012-1646
* Notes › See last page

BINDER Data Sheet | As of: 16.03.2021 Page 3 / 6


Technical specifications are subject to change.
Data Sheet Model FD 260

Designation Description * Art.-No.


Measurement of air
in accordance with ASTM D5374, denition and protocol according to ambient temperature – 8012-1195
exchange rate
Pt 100 temperature
additional flexible Pt 100, interior, for displaying the temperature on the unit display – 8012-1620
sensor
viewing window (triple insulating glass) in door, 370 x 370 mm, and 15 W interior
Viewing window and
230 V option model – 8012-1708
interior lighting
240 V option model – 8012-1710
* Notes › See last page

ACCESSORIES

Designation Description * Art.-No.

APT-COM™ 4 BASIC- for simple logging and documentation requirements with up to 5 networked units.
Edition version 4, BASIC edition – 9053-0039
for working under GLP-compliant conditions. Measured values are documented in a tamper-proof way in line with the
APT-COM™ 4 GLP- requirements of FDA Regulation 21 CFR 11.
Edition
version 4, GLP edition – 9053-0042

APT-COM™ 4 convenient unit and user management built on the BASIC edition. Suitable for networking up to 100 units.
PROFESSIONAL-Edition version 4, PROFESSIONAL edition – 9053-0040
T 350: For continuous temperature logging from 0 °C to 350 °C; kit includes 1 data logger, Pt 100 sensor with 2 m
Data Logger Kit – 8012-0714
extension cable and 1 magnetic xture for mounting to the BINDER unit
Data Logger Software LOG ANALYZE soware kit, conguration and evaluation soware for all BINDER Data Logger Kits (incl. USB data cable) – 8012-0821
pH-neutral detergent concentrated, for gentle remove of residual contaminants; 1 kg – 1002-0016
IQ/OQ documents – supporting documents for validation performed by customers, consisting of: IQ/OQ checklists incl.
calibration guide and comprehensive unit documentation; parameters: temperature, CO2, O2, pressure, depending on
unit
Digital in PDF format – 7057-0001
Hard copy inside folder – 7007-0001
Qualification documents
IQ/OQ/PQ documents – supporting documents for validation performed by customers, according to customer
requirements, PQ section added to qualication folder IQ/OQ; parameters: temperature, CO2, O2 – or pressure,
depending on unit
Digital in PDF format – 7057-0005
Hard copy inside folder – 7007-0005
chrome plated – 6004-0169
Rack
stainless steel – 6004-0153
Rack, heavy load Stainless steel, max. load per rack 70 kg – 6004-0248
Rubber pads set anti-slip feet – 8012-1887
Shelf, perforated Stainless steel – 6004-0185
Table on castors stable cart, casters with locking brakes, dimensions: W 1,300 x D 800 x H 780 mm – 9051-0019
* Notes › See last page

SERVICES

Designation Description * Art.-No.


Installation services
Connect the unit to the customer-side connections (electricity, water, wastewater, gas), basic functions
Unit commissioning check, brief operating instructions. (excl.: unpacking, setup, controller instructions, programming, 05 DL10-0100
installation work)
Instruction regarding operating principle and basic functions of the unit, operation of the control
Unit instructions 05 DL10-0500
electronics including programming
Maintenance contracts
Maintenance services
Maintenance service as contractually agreed, visual inspection of mechanical and electrical components,
BRONZE 3-year maintenance contract 05 DL20-0710
check of control response, 20% discount on spare parts
* Notes › See last page

BINDER Data Sheet | As of: 16.03.2021 Page 4 / 6


Technical specifications are subject to change.
Data Sheet Model FD 260

Designation Description * Art.-No.


Maintenance service as contractually agreed, visual inspection of mechanical and electrical components,
check of control response, 20% discount on spare parts, testing of all key functions, replacement of
GOLD 3-year maintenance contract 05 DL20-0910
wear parts, calibration of one test temperature specied by the user in the center of the usable space,
including certicate
One-o maintenance service in accordance with maintenance schedule. Visual inspection of mechanical
Maintenance and electrical components, testing of all key functions. Calibration of a test temperature specied by the 05 DL20-0200
user in center of usable space without certicate
Maintenance service as contractually agreed, visual inspection of mechanical and electrical components,
SILVER 3-year maintenance contract check of control response, 20% discount on spare parts, testing of all key functions, calibration of one 05 DL20-0810
test temperature specied by the user in the center of the usable space, without certicate
Calibration services
03, 04,
Calibration of one (1) test temperature specied by the user in center of chamber, including certicate DL30-0101
05
Calibration certicate, temperature
Extension of calibration of one (1) additional test temperature specied by the user in the center of the 03, 04,
DL30-0102
usable space, including certicate 05

03, 04,
Measurement of air exchange rate including certicate (in accordance with ASTM D5374) DL33-0000
05

Temperature measurement, 18 Temperature measurement with 18 measuring points with a set value specied by the user, including 03, 04,
DL30-0118
measuring points certicate 05

Temperature measurement, 27 Temperature measurement with 27 measuring points with a set value specied by the user, including 03, 04,
DL30-0127
measuring points certicate 05

Temperature measurement, 9 Temperature measurement with 9 measuring points with a set value specied by the user, including 03, 04,
DL30-0109
measuring points certicate 05

Validation services
Execution of IQ/OQ Execution of IQ/OQ in accordance with qualication folder 05 DL40-0100
Execution of IQ/OQ/PQ Execution of IQ/OQ/PQ in accordance with qualication folder 05 DL44-0500
Warranty service
1-year warranty extension The warranty is extended by 1 year from the delivery date, wear parts are excluded – DL50-0010
* Notes › See last page

BINDER Data Sheet | As of: 16.03.2021 Page 5 / 6


Technical specifications are subject to change.
Data Sheet Model FD 260

NOTES
01 Condensation may occur in the area around the access port. Access ports may be placed in custom locations for an additional charge.
02 UL mark is not granted when this option is used.
03 Sensor calibration is performed in an accredited calibration laboratory.
04 Calibration is performed according to the BINDER factory standard.
05 Quoted prices do not include travel costs. Please refer to the chapter on BINDER Service for travel costs for your region. Quoted prices for services performed in Switzerland do not
include a country-specic added fee (available on request).

BINDER GmbH BINDER Asia Pacific (Hong Kong) Ltd. Representative Office for CIS
Tuttlingen, Germany Kowloon, Hong Kong, P.R. China Moscow, Russia
TEL +49 7462 2005 0 TEL +852 39070500 TEL +7 495 988 15 16
FAX +49 7462 2005 100 FAX +852 39070507 FAX +7 495 988 15 17
[email protected] [email protected] [email protected]
www.binder-world.com www.binder-world.com www.binder-world.com

BINDER Environmental Testing BINDER Inc.


Equipment (Shanghai) Co., Ltd. Bohemia, NY, USA
Shanghai, P.R. China TEL +1 631 224 4340
TEL +86 21 685 808 25 FAX +1 631 224 4354
FAX +86 21 685 808 29 [email protected]
[email protected] www.binder-world.us
www.binder-world.com

BINDER Data Sheet | As of: 16.03.2021 Page 6 / 6


Technical specifications are subject to change.