db-501dt-e
db-501dt-e
Pressure transmitter
Relative 0 – 40 bar
Absolute 2,5 – 16 bar
Dynamic response
Pressure connections
Inside thread G 1/4
Outside thread G 1/4
DIN 3852 form E
Weight
Inside thread 50 grams
EDITION 07/2004 Outside thread 70 grams
Installation arrangement
Unrestricted.
Technical overview Legend to cross-section drawing
The pressure transmitter of type se- 1 Connection Fitting Signal Power supply
ries 501 with proved ceramic tech- 2 Seals
nology, features calibrated and am- 3 Ceramic element •0 – 5V 11 – 33 VDC
plified sensor signals which are avai- 4 Hybrid electronics 3-wire cable
lable as standardized current out- 5 Connector DIN 43650
puts. •1 – 6V 11 – 33 VDC
Pressure ranges 3-wire cable
Various application-specific pres- Relative pressure/Gage
sure and electrical connections can •0 – 10 V 18 – 33 VDC
(measurement of pressure relative
be provided. 3-wire cable
to ambient pressure).
Absolute pressure. •4 – 20 mA 11 – 33 VDC
Overload 2-wire cable
10 – 90 % ± 1%
10– 90% > 10 kOhm/<100 nF
Housing material
Cover Pa 6 Current consumption
With max. signal output:
Materials in contact with the medium
0 – 5 V < 2 mA
Ceramic/Stainless steel 1.4305
The distinct advantages 1 – 6 V < 2 mA
(AISI 303)
0 – 10 V < 3 mA
• Compact construction Sealing materials:
4 – 20mA < 20 mA
optionally FPM, EPDM, NBR, sili-
• Automated manufacture in large 10 – 90% < 2 mA
cone, according to order code se-
quantities for ideal price/perfor-
lection table. Electrical connections/protection class
mance ratio
• Robust ceramic sensor Temperature influences Cable 1.5 meters, IP 65
technology Medium and ambient temperature Connector DIN 43650-A, IP 65
• High resistance to extreme –15 °C to + 80 °C Connector industrial standard, IP 65
temperatures TC zero point 2.5 to 40 bar
Calibration by customer
• No mechanical aging < +/– 0.04 % fs/K
TC sensitivity Calibrated in the factory
• No mechanical creepage typically < +/– 0.015 % fs/K
A – Inside thread
G 1/4
B – Outside thread
G 1/4
D – Storage version
cover black
A B C D
E – Female connector
DIN 43650-A
F – Female connector
industrial standard
G – Electrical connec-
Versions
tion with PG 7
H – Connector M12x1
E F G H (on request)
Absolute pressure 8
power supply
Electrical connections3 Cable, 1.5 meters (protection standard IP 65) 0
Connector DIN 43650-A (protection standard IP 65) 1
Connector industrial standard (protection standard IP 65) 2
Electromagnetic compatibility:
CE conformity to EC directive 89/336 EEC (EMC) by application of harmonized standards EN 61000-6-1and EN 61000-6-3.
(burst) 1 kV
Surge EN-61000-4-5 No test
max. tolerable cable length 10 m
Magnetic fields EN 61000-4-8 No effect
30 A/m, 50 Hz
Type of interference/Emitted interference Test standard Effects
EN 55022 (CISPR 22)
Conducted interference 0.15...30 MHz No effect
Radiation from housing 30...1000 MHz, 10 meters No effect
Internet: www.hubacontrol.com
Huba Control Switzerland Huba Control United Kingdom Huba Control France Agent for:
Headquarters Unit 3 Network Point e-mail: [email protected]
Industriestrasse 17 Range Road Huba Control Germany
CH-5436 Würenlos GB-Witney Oxfordshire OX29 0YD e-mail: [email protected]
Phone ++41 (0) 56 436 82 00 Phone 01 993 776 667 Huba Control Netherlands
Fax ++41 (0) 56 436 82 82 Fax 01 993 776 671 e-mail: [email protected]
e-mail: [email protected] e-mail: [email protected]