NC4_non-contact_tool_setting_system_-_UK
NC4_non-contact_tool_setting_system_-_UK
At just 30 mm (1.18 in) diameter and 35 mm (1.38 in) high, Miniaturised electronics, and the compact protection
NC4 meets the demand for probing on machines previously system without a bulky shutter mechanism, makes the NC4
unsuitable for larger non-contact tool setting and tool suitable for machines with limited space for probe fitment.
breakage detection systems.
Environmental protection
Fast, robust and repeatable
In addition to its MicroHole™ technology, the NC4 also
Dependent on system, separation distances and mounting,
features PassiveSeal™ - an integrated failsafe device which
tools as small as 0.03 mm (0.0012 in) diameter* can be
maintains IPX8 protection 100% of the time, even if the air
measured at any selected point along the beam, and
supply fails.
checked for breakage.
One system supports all separations
Flexible systems
Available as both fixed and separate systems, with a With generic transmitter and receiver units, and no focal
measuring length of 225 mm (8.86 in) (overall unit length of point to identify, installing the separate NC4 system is
300 mm (11.81 in)) on the fixed system, and up to 5 m on simple and fast, making it ideal for retrofitting to existing
the separate system. machines.
Specification
Principal application High precision, high speed, non-contact tool
measurement and broken tool detection on vertical
and horizontal machining centres
Laser type Class 2 Laser product. Visible red light <1 mW 670 nm.
Conforms to 21 CFR 1040.10 except for deviations
pursuant to Laser Notice 50 dated June 24, 2007)
and to IEC 60825-1:2007.
Laser beam alignment Separate system: Various optional adjuster packs
are available.
Fixed system: The unit is supplied with an adjustable
mounting plate on the underside.
Electrical connection Separate system: Hardwired cable on the underside
arrangement of unit.
Fixed system: Hardwired cable on the end of the unit.
Other configurations are available on request
Sealing IPX8 (air on or off)
Typical repeatability ±0.1 µm (0.000004 in) 2σ*
Specified repeatability NC4: ± 1 µm (0.00004 in) 2σ at 1 m (3.28 ft) separation NC4 laser tool setter
NC4+ F145: ± 1 µm (0.00004 in) 2σ at 85 mm
(3.35 in) separation
Min tool Ø for setting Ø0.03 mm (0.0012 in) or larger depending on
system, separation and set-up
Min tool Ø for breakage Ø0.03 mm (0.0012 in) or larger depending on
system, separation and set-up
Power supply 120 mA @ 12 V, 70 mA @ 24 V
Output signal Two voltage-free, solid state relays (SSR).
Each can be either normally-open or normally-closed
(selectable via a switch).
Current (max.) 50 mA, voltage (max.) ±50 V.
The interface contains an auxiliary relay which can
be used for switching the output between the NC4 and a
spindle probe. This relay could also be used to control an
air blast kit (not supplied).
Temperature limit Storage –10 °C to 70 °C (14 °F to 158 °F).
Operating 5 °C to 50 °C (41 °F to 122 °F).
Life Tested to >1 million on/off cycles.
Pneumatic supply Ø3 mm air pipe, 3 bar (43 psi) min., 6 bar (87 psi) max. NC4 compact checking a tool
The air supply to the NC4 must conform to for breakage
ISO 8573-1: Class 1.7.2.
Cable 2 twisted pairs, 2 individual cores plus screen.
Each core 18/0.1 insulated. Ø6.0 mm (0.24 in) x 12.5 m
(39.36 ft) long.
Mounting Separate system: 2 off M3 x 0.5 P fixing holes plus
2 off Ø2 mm (0.079 in) dowel holes
Fixed system: Single M10 (3/8 in) or M12 (1/2 in) fixing.
Alternative fixing arrangements available
Supply protection Resettable fuses. Reset by removing power and cause
of fault.
More information
For further details on the products mentioned in this flyer, please visit
www.renishaw.com/nc4 or www.renishaw.com/mtp