Piping & Instrumentation Diagram-Low Pressure

Project
ALBA POWER STATION 5: ALBA LINE 6 EXPANSION
Owner

ALUMINIUM BAHRAIN B.S.C.

Consultant

EPC Contractor
7711
GE Global Parts &
Products GMBH
Reference Number Revision Number Functional Location Code
PS5/71/B/H-------EN/FD/004 E 01-01-022

GE POWER
Gas Power Systems

Project Document Code PS5/71/B/H-------EN/FD/004

Title Piping & Instrumentation Diagram-Low Pressure

Identification Number IHG-820002-D100-0014

Revision
Revision E 2017-04-01
Date

Language en

Document Type FD

Sheet 0/3

Responsible Department

GE CLASS II (INTERNAL NON-CRITICAL)


© COPYRIGHT 2016 General Electric Company
All rights reserved. The information herein is Proprietary and Technically Exclusive content that is solely owned by General Electric Company
and/or its affiliates. Thus, it is being provided with the explicit expectation of restricted and privileged use. All recipients of this information shall be
deemed to have agreed not to make duplications, reproductions of any nature by any means, modifications, disclosures, or use any portion of
this material; except as is expressly authorized in writing by the General Electric Company, and/or its legitimate affiliates.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

A A

To LP DRUM LEVEL CONTROL

FLOW IHG-820002-D100-0014.002

G09
CORRECTION

SEE NOTE #10


B B
FIC SEE NOTE #10
SEE NOTE #10 SEE NOTE #9
71HAC22CF002
SEE NOTE #3 TI PI PDT
(TYP) 71HAC22CT001 71HAC22CP051 71LAA91CP001

71HAC22 71HAC22

71HAC22 71HAC22

A
G14

AA307 AA308

AA305 AA306
-----------

A
71HAC22 SEE NOTE #10

71HAC22 71HAC22
ASME-1
CONTROL VALVES ARE NOT INIHG-820002-D100-0014.002

AA301 AA302
AA252

A
TIY

71HAC2271HAC22
D

AA303 AA304
GE HRSG SCOPE OF SUPPLY NOTES:
71HAC22CT002 1. THIS P &ID IS TYPICAL FOR ALL THREE UNITS IN THE CONTRACT (UNIT # 71, # 73 & # 81 ).
71HAC22 FAIL CLOSE D
AA251 THE KKS TAG INDICATED FOR UNIT # 71 AND FOR OTHER UNITS. UNIT NO IN KKA TAG SHALL BE
71HAC22 71HAC22 M 71HAC22 REPLACED ACCORDINGLY.
DN250- - - BR003 BR002 TW BR001 TW 2. ATMOSPHERIC DRAINS ARE TO BE ROUTED TO A SAFE DISCHARGE LOCATION
B12

71HAC22BR003 AT GROUND LEVEL.


DN250- - - 71HAC22 DN250- -- 71HAC22 71HAC22 DN250- - -
IHG-820002-D100-0014.002 71HAC22 DN 20
AA001 AA101 AA051
DN250- - -
71HAC22

TO LP DRUM CF001 3. VENT WILL BE DISCHARGED IN TO AN OPEN COLLECTOR WITH DRAIN PIPE.
BR013

DN250- - -
71HAC22 FURTHER PIPING TO WASTE POINT DRAINS BY GAMA.

71HAC22 71HAC22

71HAC22 71HAC22
C C
BR011

AA310 AA309

AA312 AA311
71HAC22 4. INCHING VALVES TO BE PROVIDED WITH POSITION TRANSMITTER.
71HAC22 71HAC22 71HAC22 AA203 SEE NOTE #3
AA011 BR012 AA111

71HAC22
5. TRIM LINE KKS NUMBERS WILL MATCH THE KKS NUMBER OF THE ASSOCIATED

DN250- - -
BR001
DN250- - - (TYP) TRIM VALVES.

A
71HAC22 71HAC22
M AA061 AA204 EXAMPLE: TRIM VALVE - HAC53 AA241; TRIM LINE - HAC53 BR241
AFTER ISOLATION VALVE(S) THE FIRST THREE LETTERS OF THE KKS
71HAC22 71HAC22

FIC NUMBER WILL BECOME HAN.


AA208 AA207

01
71HAC22 71HAC22

71HAC22CF003
AA210 AA209

71HAC22 F13
IHG-820002-D100-0016.001
C04 (TYP.) 6. TRIM VENTS AND INSTRUMENT CONNECTIONS ARE DN25 UNLESS
AA205 SEE NOTE #10

71HAC10

71HAC10

71HAC10
----------- OTHERWISE NOTED.

71HAC10

71HAC10

71HAC10

71HAC10

71HAC10

71HAC10

71HAC10

71HAC10

AA256

AA254

AA252
71HAN22BR202

AA272

AA270

AA268

AA266

AA264

AA262

AA260

AA258
71HAC22 ASME-1
DN50- - -

AA206 7. TRIM DRAIN CONNECTIONS ARE DN50 UNLESS OTHERWISE NOTED.


D

71HAC10

71HAC10

71HAC10
71HAC10

71HAC10

71HAC10

71HAC10

71HAC10

71HAC10
71HAC10

AA255

AA253

AA251
71HAC10
AA269

AA267

AA265

AA263

AA259

AA257
AA271

AA261
IHG-820002-D100-0016.001

D C03 8. UNITERUPTED POWER SUPPLY TO BE CONSIDER FOR REMOTE LEVEL INDICATOR D


IHG-820002-D100-0016.001

C04
71HAN22BR203

TO LP DRAIN MANIFOLD
DN50- - -

71HAN22BR206

11HAC10
9. LOOSE INSTRUMENT SUPPLIED BY GE HRSG.

DN300-
11HAC10 BR002
DN50- - -

10. ALL REMOTE INSTRUMENTS & INSTRUMENT ERECTION


HARDWARE BY GAMA.TEMPERATURE ELEMENTS FOR TRANSMITTERS SUPPLIED BY HRSG

DN100-
BR001
11.LEVEL MEASURING INSTRUMENTS ARE SHOWN IN THE SECTION SIDE VIEWS HOWEVER THE
LEVEL MEASUREMENT TAPPINGS ARE FROM THE DRUM SHELL ONLY AND NOT ON DISHED ENDS.
TO LP DRAIN MANIFOLD
ASME-1
-----------
71HAC22
AA201
REF. DRAWINGS/DOCUMENTS:
D 71HAC22
AA202 1. LEGEND SHEET P&ID-------------------------------IHG-820002-D100-0011 (PS5/71/B/H-------EN/FD/001)
E E

IHG-820002-D100-0016.001
C05 2. HIGH PRESSURE P&ID ---------------------------- IHG-820002-D100-0012 (PS5/71/B/H-------EN/FD/002)

71HAN22BR201
3. INTERMEDIATE PRESSURE P&ID----------------- IHG-820002-D100-0013 (PS5/71/B/H-------EN/FD/003)

DN50- - -
4. GAS SIDE P&ID-------------------------------------IHG-820002-D100-0015 (PS5/71/B/H-------EN/FD/005)

5. BLOWDOWN TANK P&ID -------------------------IHG-820002-D100-0016 (PS5/71/B/H-------EN/FD/006)

6. VALVE LIST -----------------------------------------IHG-820002-SZB0-1001 (PS5/71/B/H-------EN/LV/001)

TO LP DRAIN MANIFOLD 7. INSTRUMENT LIST ---------------------------------IHG-820002-SZX0-1101 (PS5/71/B/H-------EN/LI/001)

FWHTR4
FWHTR 1

FWHTR 2

FWHTR3

IHG-820002-D100-0016.001
71HAN91BR011
F F

DN150- - -
71HAC10
AC001C
71HAC10

71HAC10
AC001A

AC001B

71HAC10

01
AC001D
D07

C07

DN150 - - -
71LAA91
BR006

ASME-1
-----------
IHG-820002-D100-0016.001
71HAN91BR204

C05
71LAA91 DN50- - - TO LP DRAIN MANIFOLD
AA011 71LAA91

DN250- - -
71LCC12
71LAA91

BR001
AA203 AA204
G G

A
TI

71LAA91 71LAA91
AA301 AA302
71LAA91CT004 TI
PP SEE NOTE # 10 71LAA91CT002
D

71LAA91 71LAA91
AA303 AA304
D SEE NOTE # 10
TI

DN300---
11LAA91
TI TI 71LAA91/TP 001

BR004
71LAA91CT003
71LAA91CT001 71LAA91CT501
A

71LAA91 71LAA91 71LAA91 71LAA91


TW TW TW TW TW
BR003 AA101 BR002 BR001 CONDENSATE I/L
DN300- - - 71LAA91 DN300- -- 71LAA91 DN300- --
H AA002 AA001 H

ASME-1
-----------
FAIL TO BYPASS
DN 150 FLANGED CHEMICAL
CLEANING NOZZLE
71HAC10 71HAC10

71HAC10 71HAC10

71HAC10 71HAC10

71HAC10 71HAC10

71HAC10 71HAC10

71HAC10 71HAC10

71HAC10 71HAC10

71HAC10 71HAC10

71HAC10 71HAC10

71HAC10 71HAC10

71HAC10 71HAC10

AA201 71HAC10
AA224

AA221

AA220

AA218

AA216

AA213 AA214

AA211 AA212

AA209 AA210

AA208

AA205 AA206

AA203 AA204

AA202
D
D 71LAA91

71HAC10
AA201
AA223

AA222

AA219

AA217

AA215

AA207
ASME-1
-----------

71LAA91
IHG-820002-D100-0016.001

AA202
71HAN10BR211 ASME-1

C05
DN50- - - -----------
Supplied by Pump Vendor
IHG-820002-D100-0016.001
71LCC12/001 71HAN91BR202

C06
PDT TO LP DRAIN MANIFOLD
DN50- - -
71LCC12 71LCC12CP011 PI PI
A
J AA201 SEE NOTE # 10 71LCC12CP051 71LCC12CP052 J
71LCC12 71LCC12

(TYP)
71LCC12 71LCC12

AA303 AA304

71LCC12 71LCC12
AA302

71LCC12

AA307 AA308
A

AA306
71LCC12

COOLING WATER
AA202

D INLET
M
AA301

71LCC12
AA305

71LCC12 71LCC12 71LCC12


L.O. BR013 L.O.
BR011 BR012
IHG-820002-D100-0016.001

C05 DN250- - - 71LCC12 71LCC12 DN250 - - - DN200- - -


71LCC12 71LCC12
71LCC12 71LCC12

AA011 AT011
AA211

AA012 AA013
71HAN12BR201

71LCC12
DN50- - -

ASME-1
-----------

AP011
AA212

K A K
SEE NOTE #3

DN200- - -
71LCC13
Supplied by Pump Vendor 71LCC12/002

BR002
TO LP
Revision History
----------- DRAIN MANIFOLD
ASME-1 71LCC12 Rev. Revision Date Created by Checked by Approved by Client Description

-------------
ASME 1
AA252
{RL4}
E {RD4}
30 Mar 2017 {CB4}
P. Rana {CK4}
A. Gulati {AP4}
A. Gulati {DS4}
Revision
PDT COOLING WATER
{RL3}
D {RD3}
04 Mar 2017 {CB3}
P. Rana {CK3}
A. Gulati {AP3}
A. Gulati {DS3} as Highlighted
Revised
71LCC12 SEE NOTE # 10 71LCC12CP021 PI OUTLET
PI
AA251 71LCC12CP062 A 71LCC13 71LCC13 {RL2}
C {RD2}
23 Feb 2017 {CB2}
A. Gulati {CK2}
P. Rana {AP2}
P. Rana {DS2} as Highlighted
Revised
71LCC12CP061
71LCC12 71LCC12

71LCC12 71LCC12

BR011 BR012
AA311 AA312

AA313 AA314

{RL1}
B {RD1}
11 Nov 2016 {CB1}
A. Gulati {CK1}
P. Rana {AP1}
P. Rana {DS1}
Revision
(TYP) 71LCC12/003 DN80- - - DN80- --
71LCC12 71LCC12

71LCC12 71LCC12

71LCC13 {RL0}
A {RD0}
09 Sep 2016 {CB0}
P. Rana {CK0}
A. Gulati {AP0}
A. Gulati
AA315 AA316

AA317 AA318

71LCC13
A

COOLING WATER
AA011 Description Latest Revision :
INLET BP001
M {OL}
{ODF}
{OD}
{ODL}
FAIL OPEN
71LCC12 71LCC12 71LCC12 71LCC13
L L.O. L.O. L
BR021 BR022 BR023 BR001 PROJECT ALBA POWER STATION 5: ALBA LINE 6 EXPANSION
DN250- - -71LCC12 71LCC12 DN250- - - DN200- - -71LCC12 71LCC12 DN200- - - 71LCC13 71LCC13 71LCC13
AA021 AT021 AA022 AA023 AA001 AA101 AA002
71LCC12

-------------
71LCC13
71LCC12

ASME 1
REFERENCE Functional
ASME-1
-----------

PS5/71/B/H-------EN/FD/004 REVISION 01-01-022

AA201
NUMBER Location Code

AA221 AP021
Main Contractor
71LCC12
AA222

71LCC13
A

AA202
71LCC12/004

Replaces Scale Document Code

IHG-820002-D100-0016.001
C04 Responsible Dept. Created by Checked by Approved by Format
COOLING WATER
30 Mar 2017 P. Rana {ODF1}
01 Apr 2017 A. Gulati {ODF2}
01 Apr 2017 A. Gulati A0

71HAN13BR201
OUTLET
Originator Document Type Document Status
M M

DN50- - -
GE CLASS II (INTERNAL NON-CRITICAL)
TO LP Piping and instrument diagram {ODF3}
Approved
© COPYRIGHT 2017 General Electric Company DRAIN MANIFOLD Document Title Identification Number
All rights reserved. The information herein is Proprietary and Technically Exclusive content that is solely owned by General Electric Company and/or its affiliates. Thus, it is being
provided with the explicit expectation of restricted and privileged use. All recipients of this information shall be deemed to have agreed not to make duplications, reproductions of LOW PRESSURE SYSTEM IHG-820002-D100-0014
any nature by any means, modifications, disclosures, or use any portion of this material; except as is expressly authorized in writing by the General Electric Company, and/or its Rev. Date Lang. Sheet
legitimate affiliates.
GE POWER E 30 Mar 2017 EN 1 /3
Please consider the environment before printing this document
PRINTED 2017-03-30 12:22:58
1 2 3 4 5 6 7 8 0 9 100 10 11 12 13 14 15 16 17
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

71HAH10/TP024

A SEE NOTE #3

A --------- A

71HAH10
AA252

71HAD10
ASME - 1

BS002
SAMPLING
71HAH10
AA402

71HAH10

71HAH10
AA401

AA251
LP FEED WATER FROM
71HAC22 FW PREHEATER OUTLET
BR003 DN250- - -

C01
TO LP SUPERHEATER
71HAH10 DN250- - - 71HAC22BR003
DN250- - - BR001 IHG-820002-D100-0014.001

A10
71HAH10BR001 DN250- - - SEE NOTE #2
IHG-820002-D100-0014.003
71HAH10
BR001

71HAD10
DN250- - -

A08

BS001
71HAH10BR001 DN250- - -
IHG-820002-D100-0014.003
B B

SEE NOTE #2
SEE NOTE #3 DEAERATOR
SEE NOTE #10 SEE NOTE #10 SEE NOTE #10 SEE NOTE #9
71HAD10BB001
PIYSZA PIYSZA PIYSZA PI

ASME - 1
---------
71HAD10CP003 71HAD10CP002 71HAD10CP001 71HAD10CP501
IHG-820002-D100-0012.002

IHG-820002-D100-0013.002
TO HP DRUM
71LFJ10BR003

71LFJ10BR004

TO IP DRUM
DN25- - -

DN25- - -

(TYP.)

71HAD10

71HAD10
---------

AA310

AA252

71HAD10
--------- (TYP) 71HAD10

71HAD10 71HAD10
AA308

71HAD10 71HAD10
ASME - 1

AA305 AA306

AA303 AA304
ASME - 1 AA021

A
71HAD1071HAD10
71HAD10

AA301 AA302
71LFJ10/TP022
AA011

71HAD10

71HAD10
ASME - 1
D01 C02

AA309

AA251

71HAD10
A

AA307
---------

ASME - 1
D D

---------
(QTY - 2)

DN450- - -
71HAD10

(QTY - 2)
DN600- - -
71HAD10
C C

BR003
BR004

SEE NOTE #2
NITROGEN FEED
71LFJ10 71LFJ10 71HAD10 IHG-820002-D100-0013.002 71LBS30
AA701 DN 50 X 25 AA702 AA701
71LBS30BR003 BR003

B13
RED. PIPE
DN400- - -
71LFJ10

DN400- - - B
AA201

PEGGING STEAM LINE


FROM IP DRUM A
71LFJ10
AA202

TM TM TM TM
71HAD10CT001 71HAD10CT002 71HAD10CT003 71HAD10CT004 NOTES:
1. THIS P &ID IS TYPICAL FOR ALL THREE UNITS IN THE CONTRACT (UNIT # 71, # 73 & # 81 ).
71LAB55/TP001
THE KKS TAG INDICATED FOR UNIT # 71 AND FOR OTHER UNITS. UNIT NO IN KKA TAG SHALL BE
IHG-820002-D100-0016.001

C03 RESTRICTION ORIFICE WILL BE


A
REPLACED ACCORDINGLY.
SUPPLIED LOOSE BY GAMA
71HAN10BR202

D 2. ATMOSPHERIC DRAINS ARE TO BE ROUTED TO A SAFE DISCHARGE LOCATION D


AT GROUND LEVEL.
DN50- - -

71LAB55
LP STEAM DRUM / STORAGE TANK BR001
RECIRC LINE FROM BFP I 3. VENT WILL BE DISCHARGED IN TO AN OPEN COLLECTOR WITH DRAIN PIPE.
DN150- - -
71LAB55 FURTHER PIPING TO WASTE POINT DRAINS BY GAMA.
71HAD10BB002 BP001
71LAB55 71LAB55/TP002 4. INCHING VALVES TO BE PROVIDED WITH POSITION TRANSMITTER.
BR011
A
TO LP DRAIN MANIFOLD DN150- - - 5. TRIM LINE KKS NUMBERS WILL MATCH THE KKS NUMBER OF THE ASSOCIATED
TRIM VALVES.
TM EXAMPLE: TRIM VALVE - HAC53 AA241; TRIM LINE - HAC53 BR241
TM TM TM RECIRC LINE FROM BFP II AFTER ISOLATION VALVE(S) THE FIRST THREE LETTERS OF THE KKS
71HAD10CT008
71HAD10CT005 71HAD10CT006 71HAD10CT007 NUMBER WILL BECOME HAN.
71LAB55
BP011 REFER GAMA P&ID ALBA-00-LA-PR-DW-IDM-0707
6. TRIM VENTS AND INSTRUMENT CONNECTIONS ARE DN25 UNLESS
SEE NOTE # 10
OTHERWISE NOTED.

E 7. TRIM DRAIN CONNECTIONS ARE DN50 UNLESS OTHERWISE NOTED. E


A B

(QTY - 6) 8. UNITERUPTED POWER SUPPLY TO BE CONSIDER FOR REMOTE LEVEL INDICATOR

9. LOOSE INSTRUMENT SUPPLIED BY GE HRSG.

DN250- - -
71HAD10
BR001
10. ALL REMOTE INSTRUMENTS & INSTRUMENT ERECTION
HARDWARE BY GAMA.TEMPERATURE ELEMENTS FOR TRANSMITTERS SUPPLIED BY HRSG

DN100- - -
71HAD10
BR002
E E
SEE NOTE #10 11.LEVEL MEASURING INSTRUMENTS ARE SHOWN IN THE SECTION SIDE VIEWS HOWEVER THE
SEE NOTE #10 LEVEL MEASUREMENT TAPPINGS ARE FROM THE DRUM SHELL ONLY AND NOT ON DISHED ENDS.
REFER GAMA P&ID ALBA-00-LA-PR-DW-IDM-0707
71LAB51 TW TW
BR001 TI TI
F TO BFP I&II SUCTION
DN350- - - 71HAD10CT010 71HAD10CT009 F
REF. DRAWINGS/DOCUMENTS:
A
1. LEGEND SHEET P&ID-------------------------------IHG-820002-D100-0011 (PS5/71/B/H-------EN/FD/001)
71LAB51/TP001
2. HIGH PRESSURE P&ID ---------------------------- IHG-820002-D100-0012 (PS5/71/B/H-------EN/FD/002)

3. INTERMEDIATE PRESSURE P&ID----------------- IHG-820002-D100-0013 (PS5/71/B/H-------EN/FD/003)

4. GAS SIDE P&ID-------------------------------------IHG-820002-D100-0015 (PS5/71/B/H-------EN/FD/005)

5. BLOWDOWN TANK P&ID -------------------------IHG-820002-D100-0016 (PS5/71/B/H-------EN/FD/006)


FEED WATER To DRUM FLOW CORRECTION
6. VALVE LIST -----------------------------------------IHG-820002-SZB0-1001 (PS5/71/B/H-------EN/LV/001)
IHG-820002-D100-0014.001
LP EVAPORATOR

B06
7. INSTRUMENT LIST ---------------------------------IHG-820002-SZX0-1101 (PS5/71/B/H-------EN/LI/001)
G 71HAD10 G
AC001
STEAM O/L FLOW CORECTION
IHG-820002-D100-0014.003 LP DRUM IHG-820002-D100-0014.001

B03
F06
LEVEL CONTROL

LEVEL CONTROL

H H
71HAD10

DN 150 FLANGED CHEMICAL


AA203

FAIL CLOSE
CLEANING NOZZLE,
(QTY. 2)
71HAD10
AA201
71HAD10
AA204

ASME - 1 FAIL CLOSE


---------
71HAD10
INTERMITTENT/ STARTUP

AA202

ASME - 1
--------- GAS FLOW
IHG-820002-D100-0016.001

D13
BLOWOFF TO BDT

71HAN10BR203

GAS FLOW
DN50- - -

IHG-820002-D100-0016.001
J (TYP) 71HAN10BR201 LP EVAP J
C03

DN50- - - DRAIN
A TO LP DRAIN MANIFOLD
L.O. L.O. L.O. L.O.
D
71HAD10 71HAD10 71HAD10 71HAD10 71HAD10
REMOTE WATER L.O. L.O. D
LEVEL INDICATOR AA334 AA333
REMOTE WATER
AA312 AA311 BB005
71HAD10 71HAD10 LEVEL INDICATOR
AA325 AA326
71HAD10 71HAD10 71HAD10 71HAD10
A

A
AA316 AA315 AA321 AA322
71HAD10

ASME - 1
--------------
(TYP)
AA323
71HAD10 71HAD10 71HAD10
AA329 AA330
71HAD10 A
BB003
K K
71HAD10CL002

SEE NOTE #10

BB004
71HAD10CL501
LICZA

SEE NOTE #10

Revision History
71HAD10CL001

SEE NOTE #10

71HAD10CL003
LI

LICZA

Rev. Revision Date Created by Checked by Approved by Client Description

LICZA
{RL4}
E {RD4}
30 Mar 2017 {CB4}
P. Rana {CK4}
A. Gulati {AP4}
A. Gulati {DS4}
Revision

{RL3}
D {RD3}
04 Mar 2017 {CB3}
P. Rana {CK3}
A. Gulati {AP3}
A. Gulati {DS3} as Highlighted
Revised

{RL2}
C {RD2}
23 Feb 2017 {CB2}
A. Gulati {CK2}
P. Rana {AP2}
P. Rana {DS2} as Highlighted
Revised

A A
A {RL1}
B {RD1}
11 Nov 2016 {CB1}
A. Gulati {CK1}
P. Rana {AP1}
P. Rana {DS1}
Revision
LCU
71HAD10 {RL0}
A {RD0}
09 Sep 2016 {CB0}
P. Rana {CK0}
A. Gulati {AP0}
A. Gulati

AA324 Description Latest Revision :


LCU (TYP) 71HAD10 71HAD10 {ODF}
71HAD10 71HAD10 71HAD10 71HAD10 AA319 AA320
{OL} {OD}
{ODL}
AA331 AA332 AA318 AA317
A L.O. L.O. DN 15
L PROJECT ALBA POWER STATION 5: ALBA LINE 6 EXPANSION L
L.O. L.O. 71HAD10 71HAD10
71HAD10

L.O. L.O.
AA208
71HAD10

AA327 AA328
AA210

71HAD10 71HAD10
AA336 AA335 71HAD10 71HAD10 REFERENCE Functional
PS5/71/B/H-------EN/FD/004 REVISION 01-01-022
AA314 AA313 NUMBER Location Code

Main Contractor
71HAD10
71HAD10

AA209
AA211

Replaces Scale Document Code


A TO LP DRAIN MANIFOLD
SECTION A-A IHG-820002-D100-0016.001 Responsible Dept. Created by Checked by Approved by Format
A

71HAN10BR205 30 Mar 2017 P. Rana {ODF1}


01 Apr 2017 A. Gulati {ODF2}
01 Apr 2017 A. Gulati A0
C02

M DN 20 STUB FOR RWLI


DN20- - -
SECTION B-B Originator Document Type
Piping and instrument diagram
Document Status
{ODF3}
Approved
M
DRAIN CONNECTION (TYP) Document Title Identification Number

CONFIDENTIAL
GE CLASS II (INTERNAL NON-CRITICAL)
© COPYRIGHT 2017 General Electric Company
LOW PRESSURE SYSTEM IHG-820002-D100-0014
Rev. Date Lang. Sheet
All rights reserved. The information herein is Proprietary and Technically Exclusive content of the General Electric Company and/or its legitimate affiliates. GE POWER E 30 Mar 2017 EN 2 /3
Please consider the environment before printing this document
PRINTED 2017-03-30 12:23:26
1 2 3 4 5 6 7 8 0 9 100 10 11 12 13 14 15 16 17
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

SAT STEAM FROM


71HAH10 LP DRUM
A SAT STEAM FROM A
BR001 DN250- - -

B03
LP DRUM
DN250- - - 71HAH10BR001
IHG-820002-D100-0014.002 IHG-820002-D100-0014.002
71HAH10BR001

B03
DN250- - -

DN 250---

71HAH11
BR001
D

DN150- - -
71HAH11
BR002
B B

C C

71HAH12
AC001

D D

NOTES:
1. THIS P &ID IS TYPICAL FOR ALL THREE UNITS IN THE CONTRACT (UNIT # 71, # 73 & # 81 ).
THE KKS TAG INDICATED FOR UNIT # 71 AND FOR OTHER UNITS. UNIT NO IN KKA TAG SHALL BE
LP SH REPLACED ACCORDINGLY.
2. ATMOSPHERIC DRAINS ARE TO BE ROUTED TO A SAFE DISCHARGE LOCATION
AT GROUND LEVEL.

3. VENT WILL BE DISCHARGED IN TO AN OPEN COLLECTOR WITH DRAIN PIPE.


FURTHER PIPING TO WASTE POINT DRAINS BY GAMA.
TW D
DN 100 X 50
RED. PIPE 4. INCHING VALVES TO BE PROVIDED WITH POSITION TRANSMITTER.
E FAIL OPEN 71LBA10 E

71LBA10
5. TRIM LINE KKS NUMBERS WILL MATCH THE KKS NUMBER OF THE ASSOCIATED

AA201
BR201
DN100- - - TRIM VALVES.
EXAMPLE: TRIM VALVE - HAC53 AA241; TRIM LINE - HAC53 BR241
FAIL OPEN TIY
AFTER ISOLATION VALVE(S) THE FIRST THREE LETTERS OF THE KKS

71LBA10
71LBA10CT002 NUMBER WILL BECOME HAN.

AA202
ASME-1

-------------
ASME-1
-------------
6. TRIM VENTS AND INSTRUMENT CONNECTIONS ARE DN25 UNLESS

(TYP)
OTHERWISE NOTED.

7. TRIM DRAIN CONNECTIONS ARE DN50 UNLESS OTHERWISE NOTED.

IHG-820002-D100-0016.001
TO LP DRUM LEVEL CONTROL C06 SEE NOTE #10

71HAN10BR204
IHG-820002-D100-0014.002 A
FLOW 8. UNITERUPTED POWER SUPPLY TO BE CONSIDER FOR REMOTE LEVEL INDICATOR

DN50- - -
G09

TO LP DRAIN MANIFOLD

SEE NOTE #9
71LBA10

71LBA10CP501
CORRECTION 9. LOOSE INSTRUMENT SUPPLIED BY GE HRSG.
AA301

PI
F 10. ALL REMOTE INSTRUMENTS & INSTRUMENT ERECTION F
71LBA10 HARDWARE BY GAMA.TEMPERATURE ELEMENTS FOR TRANSMITTERS SUPPLIED BY HRSG
AA302

-------------
11.LEVEL MEASURING INSTRUMENTS ARE SHOWN IN THE SECTION SIDE VIEWS HOWEVER THE

ASME-1
LEVEL MEASUREMENT TAPPINGS ARE FROM THE DRUM SHELL ONLY AND NOT ON DISHED ENDS.

(TYP)
71LBA10

71LBA10CP001
71LBA10 AA303
AA304

PIYS
DN 250 FLANGED CHEMICAL REF. DRAWINGS/DOCUMENTS:

SEE NOTE #10


CLEANING NOZZLE
D 1. LEGEND SHEET P&ID-------------------------------IHG-820002-D100-0011 (PS5/71/B/H-------EN/FD/001)
A
2. HIGH PRESSURE P&ID ---------------------------- IHG-820002-D100-0012 (PS5/71/B/H-------EN/FD/002)

3. INTERMEDIATE PRESSURE P&ID----------------- IHG-820002-D100-0013 (PS5/71/B/H-------EN/FD/003)

G 71LBA10/TP025 4. GAS SIDE P&ID-------------------------------------IHG-820002-D100-0015 (PS5/71/B/H-------EN/FD/005) G


A
5. BLOWDOWN TANK P&ID -------------------------IHG-820002-D100-0016 (PS5/71/B/H-------EN/FD/006)

6. VALVE LIST -----------------------------------------IHG-820002-SZB0-1001 (PS5/71/B/H-------EN/LV/001)


SAMPLING
71LBA10 71LBA10 7. INSTRUMENT LIST ---------------------------------IHG-820002-SZX0-1101 (PS5/71/B/H-------EN/LI/001)
AA402 AA401

SEE NOTE #10


FIC SEE NOTE #10

71LBA10
BS001
71LBA10CF002
H TI TIY H
71LBA10CT501 71LBA10CT001
(TYP)
71LBA1071LBA10

71LBA1071LBA10

FAIL CLOSE
AA309 AA310

AA311 AA312

-------------
ASME-1

71LBA10 M 71LBA10
71LBA10/TP001 BR251 BR252
A DN200- - - 71LBA10 71LBA10 DN250- - -
AA251 AA101 SEE NOTE #2

71LBA10
71LBA10 M 71LBA10 71LBA10

AA204
AA051 TW TW FAIL IN POSITION
BR002 BR001
LP STEAM OUTLET
DN400- - - DN400- - -
71LBA10

DN 50
71LBA10

71LBA10 71LBA10

REFER GAMA P&ID M


AA305

CF001
AA307

ALBA-00-LBD-PR-DW-IDM-0705
71LBA10
J AA051A SEE J
AA308
71LBA10

NOTE #2
AA306

71LBA10 SEE NOTE #2


FIC
AA011
71LBA10CF003
-------------
ASME-1

SEE NOTE #10

K K

Revision History
Rev. Revision Date Created by Checked by Approved by Client Description
{RL4}
E {RD4}
30 Mar 2017 {CB4}
P. Rana {CK4}
A. Gulati {AP4}
A. Gulati {DS4}
Revision

{RL3}
D {RD3}
04 Mar 2017 {CB3}
P. Rana {CK3}
A. Gulati {AP3}
A. Gulati {DS3} as Highlighted
Revised

{RL2}
C {RD2}
23 Feb 2017 {CB2}
A. Gulati {CK2}
P. Rana {AP2}
P. Rana {DS2} as Highlighted
Revised

{RL1}
B {RD1}
11 Nov 2016 {CB1}
A. Gulati {CK1}
P. Rana {AP1}
P. Rana {DS1}
Revision

{RL0}
A {RD0}
09 Sep 2016 {CB0}
P. Rana {CK0}
A. Gulati {AP0}
A. Gulati

Description Latest Revision :


{ODF}
{OL} {OD}
{ODL}

L PROJECT ALBA POWER STATION 5: ALBA LINE 6 EXPANSION L

REFERENCE Functional
PS5/71/B/H-------EN/FD/004 REVISION 01-01-022
NUMBER Location Code

Main Contractor

Replaces Scale Document Code

Responsible Dept. Created by Checked by Approved by Format


30 Mar 2017 P. Rana {ODF1}
01 Apr 2017 A. Gulati {ODF2}
01 Apr 2017 A. Gulati A0
Originator Document Type Document Status
M M
Piping and instrument diagram {ODF3}
Approved
Document Title Identification Number

CONFIDENTIAL
GE CLASS II (INTERNAL NON-CRITICAL)
© COPYRIGHT 2017 General Electric Company
LOW PRESSURE SYSTEM IHG-820002-D100-0014
Rev. Date Lang. Sheet
All rights reserved. The information herein is Proprietary and Technically Exclusive content of the General Electric Company and/or its legitimate affiliates. GE POWER E 30 Mar 2017 EN 3 /3
Please consider the environment before printing this document
PRINTED 2017-03-30 12:23:43