TO STUDY THE CONNECTIONS AND OPERATION OF A SELF-EXCITED SERIES-
WOUND DC GENERATOR WHEN DRIVEN WITH THE HELP OF A PRIME MOVER
APPARATUS:
Two DC machines of the same type (Model: M-1/EV); one will be used as a series-wound DC
generator and another one as a shunt-wound DC motor i.e. the prime mover, a variable DC
power supply (Model: CEM-E-A/EV), connecting wires, voltmeters, and ammeters.
PROCEDURE:
Connect one DC machine as a shunt-wound DC motor and another as a series-wound DC
generator according to the circuit diagram. The shunt-wound DC motor will be used as a prime-
mover to mechanically drive the armature of the series-wound DC generator.
Note that prime mover is the machine which mechanically drives the shaft of the generator i.e.
which provides mechanical energy to the generator.
Mechanically couple the shafts (armatures) of the two DC machines. Now switch on the DC
power supply and gradually increase the input voltage of the shunt-wound DC motor. The shunt-
wound DC motor will start rotating and will also mechanically drive the armature of the series-
wound DC generator. As soon as the armature of the series-wound DC generator starts rotating,
it will build up the voltage across its output terminals detectable by a DC voltmeter.
CIRCUIT DIAGRAM:
Types of DC Generators
DC Generators are classified based on the position of the field coils and armature in the circuit,
and how the generator’s magnetic field is excited (i.e. produced). Some portable generators are
DC generators.
Series Wound Generators
In series wound generators, field winding and the armature winding are connected in series so
that current that passes through external circuit and through field windings, passes from armature
as shown in the figure below. The field coil of series-wound generator has low resistance, consist
of a few turns of thick wire. If the load resistance decreases, then current flow increases.
As a result magnetic field and output voltage increases in the circuit. In such type generator,
output voltage varies directly with respect to load current which is not required in most of the
application. Due to this reason, such types of generators are rarely used.
Here the shunt field winding is connected parallel to armature only as shown in figure. Series
winding is then connected in series.
Here the shunt field winding is connected parallel to armature only as shown in figure. Series
winding is then connected in series.
Observations:
Table 1
1 0 0 0
2 60 1.02 0.08
3 82 1.22 0.2
Table # 2
(V) (V)
1 0 0
2 50 1.03
3 80 1.24
4 140.5 1.92
5 188.5 3.162
6 224.5 6.9
7 228.5 48.2