SVIM BOQ
SVIM BOQ
1 Ground Floor
HDU 6 CDU 16 1 1 6 1 1 6
2 First Floor
MICU 12 CDU 16 1 1 12 1 1 0 12
Suite Room 4 CDU 16 1 1 4 4 4 0 4
Nursary 10 CDU 16 1 1 10 1 1 10
NICU 6 CDU 16 1 1 6 1 1 6
3 Second Floor
Pvt Room 9 CDU 16 1 1 9 9 0 9 0 9
Pvt Room 3 3 3 0 3 0 3
CDU 16 1 1
Semi Pvt 4 4 0 2 0 2 4
4 Third Floor
Dialysis Ward 5 CDU16 1 1 5 1 1 5
Ward - 1 5 5 1 1 6
Ward - 2 5 5 1 1 4
Ward - 3 7 7 1 1 7
Ward - 4 7 CDU 32 1 1 7 1 1 7
Ward - 5 7 7 1 1 7
Male Toilet 1
Female Toilet 2
5 Fifth Floor
CCU1 12 CDU 16 1 1 12 1 1 12
CCU2 7 CDU 16 1 1 7 1 1 7
6 Sixth Floor
Single Rooms 20 CDU24 1 1 20 20 20 20
Remarks :BOQ as per discussion with customer during site visit and qty varified by
F/SA/24
Remarks :BOQ as per discussion with customer during site visit and qty varified by
Note:
customer on PO
*- Product Code: Toilet units for all Single Bedded Rooms.
**- Product Code: Toilet units for all multi Bedded Rooms.
***- Product code : Door Indicators for all Double Bedded Rooms only.
^ - Product code : According to number of beds for par nursing station (
Modules - 16/24/32/48/63)
Backend- BACKEND BOQ has been issued -YES/NO - If Yes, Date: If No, then tentative Date:
CDU- Central
Display Unit
230V AC @ RJ45 information
(Nurse Station LCD/LED TV : WALL MOUNT require, identify and finalized the
50Hz, 5A UPS outlet within NCP Accessible
1 Display) LCD Height from floor and location; NCP (Nurse Call Processor ) :-
socket within 500mm; HDMI to Nursing staff
/LED TV ; NCP - Desktop recommended
500mm distance cable require from
Nurse Call LCD/LED TV to
Processor NCP
*All cables from
the rooms to Accessible for
Nurse station On a shelf (provided by customer) which is at an accessible location in 230V AC @ NSE/SRH to be Service
extender : Nursing station. Ensure that the cables drop from the top.NS_ 50Hz, 5A UPS identified using purspose.Wirin
2
NS_Extender Extenders can be stacked one above the other in the same shelf. Trap socket within ferrule sleeves and g as per GIVEN
(NSE) door required in case installed inside ceiling 500mm distance brought to the DRAWINGS
shelf. ONLY
In line with the top of the door facing the corridor.Hole CTC is 40mm Above the door
Cat6 cable from
4 Door indicator , 1.5" Round type terminal MS box or In case of Ceiling placement Nil at height of 8’ft
the Bed unit
,require Cat 6 wire inside ceiling just above the center of door from floor
In line with the WC/commode at a height of 5/6 feet from ground level.
To be fixed in a metal gang box provided in the wall GI Box Cat6 cable from At water
5 Toilet calling unit Nil
dimensions : 102.5mm(W)*79.5mm(H) the Bed unit restricted wall
Plastic Back Box dimensions : 115mm(W)*85mm(H)
F/SA/24
In the cut-out provided in the bed headed panel or 4x3 metal gang box
provided in the wall. Preferably to the next of the Bed calling unit, Cut Cat6 cable from
6 Instrument Alarm Nil Next to bed unit
out dimension: 76 mm(W)*78mm (H) ; the Bed unit
Hole to Hole Pitch is 86 mm (CTC)
Suggest at
Bed Call unit with In the cut-out provided in the bed headed panel or 5x3 metal gang box Cat6 cable from
7 Nil height of 3’ft
service Call provided in the wall. Preferably to the next of the Bed calling unit. the Bed unit
from floor
230V AC @
Recommended
Escalation Display On a Wall /Desk which is at an accessible location in head supervisor's 50Hz, 3A UPS Centralised
8 at Central
-Multimode NCP room/ MS Room..etc as per decided by customer socket within LAN/DATA point
location
500mm distance
F/SA/24