TDK general
TDK general
APPLICATIONS
Computers and other terminal devices, office automation equip-
ment, general control devices, and other industrial devices.
Ground 1 4
terminal øH
A
I
2 3
øG
K B
J E
C D
F
Dimensions in mm
Part No. A B C D E F øG øH I J K
ZAG2206-11S 50.8 62 40 85 75 95 M4 4.8 18 25 7.5
ZAG2210-11S 50.8 62 40 85 75 95 M4 4.8 18 25 7.5
ZAG2220-11S 50.8 62 40 85 75 95 M4 4.8 18 25 7.5
ZAG2230-11S 56 90 50 111 103.2 138 M5 4.8 21 31.7 8.2
• Case: metal, terminal: stud
• Conformity to RoHS Directive: This means that, in conformity with EU Directive 2002/95/EC, lead, cadmium, mercury, hexavalent chromium, and specific
bromine-based flame retardants, PBB and PBDE, have not been used, except for exempted applications.
ELECTRICAL CHARACTERISTICS
Part No. ZAG2206-11S ZAG2210-11S ZAG2220-11S ZAG2230-11S
Rated voltage Eac(V) 250 250 250 250
Rated current(A) 6 10 20 30
Test voltage Eac(V)[Between terminal and case] 1500 1500 1500 1500
Insulation resistance(MΩ)[DC. 500V, 1min/between terminal and case] 100min. 100min. 100min. 100min.
Leakage current(mA)[250V • 60Hz] 0.75max. 0.75max. 0.75max. 0.75max.
DC resistance(mΩ) 100max. 50max. 20max. 9max.
Operating temperature range(°C)[Including self-temperature rise] –25 to +85 –25 to +85 –25 to +85 –25 to +85
With derating over(°C) 55 55 55 55
Temperature rise(°C) 30max. 30max. 30max. 30max.
Attenuation frequency range Differential mode 0.5 to 10[40dB] 0.5 to 10[40dB] 1 to 10[40dB] 0.5 to 30[30dB]
(MHz)[+5 to +35°C] Common-mode 0.3 to 20[30dB] 0.5 to 20[30dB] 1 to 10[28dB] 0.5[15dB], 1 to 30[20dB]
Pulse attenuation characteristics Differential mode at 20dB 1 1 1 1
Input pulse voltage(kV)∗ Common mode at 20dB 2 2 1.2 0.8
Weight(g) 270 300 320 480
∗ Input pulse width : 1µs
Attenuation (dB)
60 60
Common mode
40 40
Common mode
20 20
0 0
0.1 0.3 1 3 10 30 100 0.1 0.3 1 3 10 30 100
Frequency (MHz) Frequency (MHz)
ZAG2220-11S ZAG2230-11S
100 100
Differential mode
80 80
Differential mode
Attenuation (dB)
Attenuation (dB)
60 60
40 40
Common mode Common mode
20 20
0 0
0.1 0.3 1 3 10 30 100 0.1 0.3 1 3 10 30 100
Frequency (MHz) Frequency (MHz)
150 150
e
tio n lin line
nua ua tion
100 atte 100 tten
20d
B Ba
20d Common mode
Differential mode
50 Differential mode 50
Common mode
0 0
0 500 1000 1500 2000 0 500 1000 1500 2000
Input voltage (V) Input voltage (V)
ZAG2220-11S ZAG2230-11S
300 300
Pulse width: 1µs Pulse width: 1µs
250 250
Common mode
Output voltage (V)
CIRCUIT DIAGRAMS
ZAG2206-11S, 2210-11S, 2220-11S ZAG2230-11S
4 4
1 1
R
2 3 2 3
R: Bleeder resistor Case GND R: Bleeder resistor Case GND
øH
Ground
terminal
R1 R2
S1 S2
A
E
I
øG
T1 T2
K B
J F
C D
Dimensions in mm
Part No. A B C D E F øG H I J K
ZAGT2230-M 105 120 80 176 85 140 M6 5.5 64 50 20
ZAGT2250-M 110 150 80 212 90 170 M6 5.5 64 50 20
ZAGT2280-M 120 200 110 274 100 220 M8 5.5 64 66 30
• Case: metal, terminal: stud
ELECTRICAL CHARACTERISTICS
Part No. ZAGT2230-M ZAGT2250-M ZAGT2280-M
Rated voltage Eac(V) 250 250 250
Rated current(A) 30 50 80
Test voltage Eac(V)[Between terminal and case] 2000 2000 2000
Insulation resistance(MΩ)
100min. 100min. 100min.
[DC. 500V, 1min/between terminal and case]
Leakage current(mA)[250V • 60Hz] 1max. 1max. 1max.
DC resistance(mΩ) 10max. 6max. 3.5max.
Operating temperature range(°C)[Including self-temperature rise] –25 to +85 –25 to +85 –25 to +85
With derating over(°C) 55 55 55
Temperature rise(°C) 30max. 30max. 30max.
Attenuation frequency range Differential mode 0.3 to 30[25dB] 0.4 to 30[20dB] 0.5 to 30[20dB]
(MHz)[+5 to +35°C] Common-mode 0.3 to 20[25dB] 0.3 to 30[20dB] 0.5 to 30[20dB]
Weight(kg) 1.7 2.5 5.5
Specifications which provide more details for the proper and safe use of the described product are available upon request.
All specifications are subject to change without notice.
9121_ZAGT_M
(2/2)
Attenuation(dB)
Attenuation(dB)
60 60
Common-mode 40
40
Common-mode
20 20
0 0
0.1 0.3 1 3 10 30 100 0.1 0.3 1 3 10 30 100
Frequency(MHz) Frequency(MHz)
Protective load
Differential mode
80
R
S1 S2
Attenuation(dB)
60 T1 T2
0
0.1 0.3 1 3 10 30 100
Frequency(MHz)
CAUTIONS
• When there is a danger of a high energy pulse voltage (over 2kV
for over 1µs), use a surge absorbing element such as a varistor,
or an arrestor on the EMC filter power supply input side.
9121_ZAGT_M
000317
Specifications which provide more details for the proper and safe use of the described product are available upon request.
All specifications are subject to change without notice.