III Install BMS on Battery Module

Install the BMS on the batter y module. Fix it with M5 screws on holes shown as below with L-type Wrench.
Please pay attention to the correct direction of BMS and batter y modules, and put the same side of BMS
and batter y modules at front.

Quick Installation Guide


—— Triple Power Lithium-ion Battery

I Packing List IV Floor/Wall Mounting (alternative)


Note: The quick installation guide describes installation steps briefly. If you have any questions during Note: 1. For 2~4 battery modules, please finish the floor mounting or wall mounting before connecting cables!
the installation, please refer to the User Manual for more information. 2. Please make sure that the inverter is completely switched off when connecting cables!

- Mark the position of the holes. - Drill holes with a Φ 10 drill bit. - Hammer the expansion tubes
- Depth: at least 50mm. into the holes.

Battery Power Cable (+) ×1 Bracket(205*80*12mm)


BMS×1 CAN Cable ×1
Battery Power Cable (-) ×1 Power Cable (120mm)×1 Female DC unit×1 (for floor mounting)
(Master Box) RS485 Cable (120mm)×1
BMS

Bracket(353*138*42mm)
(for wall mounting)
Ground wire×1 Rotation Wrench×1
Short Circuit Plug×1 L-type wrench×1 User Manual ×1
M5 Screw×4 - Screw the expansion bolts. - Match the battery module with the bracket.

Battery module×1 Power Cable (400mm)×1 Bracket(wall mounting)×1


RS485 Cable (400mm)×1 Bracket(floor mounting)×1
Batter y (T45/T63)
375mm
Module
Quick Installation Guide
300 mm
—— Triple Power Lithum-ion Battery

Note: for floor mounting, the distance between the bottom of battery module and the lower hole of wall bracket is 375mm;
It is recommended to keep a distance of at least 250mm between battery modules;
Expansion bolt ×5 M6 Screw×1 Ring Terminal×2 Quick installation guide×1
for wall mounting, the distance between the bottom of battery module and floor shall not exceed 300mm.

II Installation Prerequisites V Power Cable Connectioin


Make sure that the installation location meets the following conditions:
Ÿ The building is designed to withstand earthquakes - For one battery module:
Ÿ The location is far away from the sea, to avoid saline water and humid air Step 1. Plug either end of the 120mm power cable
Ÿ The floor is flat and level into the XPLUG port on BMS, and the other end into
Ÿ There are no flammable or explosive materials nearby the XPLUG port on battery module.
Ÿ The ambient environment is shady and cool, and away from heat as well as direct sunlight Step 2. When the metal sheet is totally inserted
Ÿ The temperature and humidity stay at a constant level. and a click sound is heard, that means the power
Ÿ There is minimal dust and dirt in the area. cable is properly connected.
Ÿ There is no corrosive gases present, including ammonia and acid vapor. Step 3. Once finished, please connect the short-
Ÿ The ambient temperature is within the range from 0°C to 45°C, and the optimal ambient temperature is between circuit plug to the YPLUG port on battery module to
15℃ and 30°C. complete the internal circuit.

NOTE!
- For more battery modules:
The Triple Power battery is rated at IP55 and thus can be installed outdoors as well as indoors. Step.1 Plug either end of the 120mm power cable into the XPLUG port
However, if installed outdoors, do not expose the battery directly to sunlight and moisture. on BMS, and the other end into the XPLUG port on the first battery
module.
Step.2 Then plug one end of the 400mm power cable into the YPLUG
NOTE! port on the first battery module, and the other end into the XPLUG port
on the next battery module.
If the ambient temperature is beyond the operating range, the battery will stop operating to protect itself. Step.3 Repeat the same step on all the battery modules.
The optimal temperature range for the battery to operate is from 15°C to 30°C. Frequent exposure to harsh Step.4 Once finished, please connect the short-circuit plug to the YPLUG
temperatures may deteriorate the performance and lifetime of the battery. port on the last battery module to complete the internal circuit.
VI RS485 Connection IX Battery Power Cable Connection 1
Step2. Tighten the plastic - One end of the battery power cable needs to be connected manually as below:
Step1. Connect the screw caps on both ends of the
RS485 communication cable with the rotation wrench
cable (120mm) from the from the package. Step1.
RS485 port on BMS to Note: For 2-4 modules, please screw connection
screw connection
the RS485 I port on the connect RS485 II port of the
first battery module. first battery module to RS485 I
port on the next battery
module. Repeat the same step
to connect the rest battery
modules.
The wiring order of the communication cable is as follow:

1) White with an orange stripe


2) Orange Step2. spring Step 3.
1 2 3 4 5 6 7 8
3) White with a green stripe
4) Blue
5) White with a blue stripe chamber
6) Green
7) White with a brown stripe
8) Brown

Sequence 1 2 3 4 5 6 7 8
wire strands Torgue:2.0±0.2Nm
RS485I VCC_485 GND_485 B2 N- P+ A2 VCC_485_2 GND_485
RS485II VCC_485 GND_485 B2 N- P+ A2 VCC_485_2 GND_485

VII CAN Connection X Battery Power Cable Connection 2


- Insert the battery power cable into the BAT connectors on the inverter as shown below:

Step1: Make sure the inverter is turned off, and then insert one end
of the CAN communication cable to the BMS port on the Inverter.
Assemble the cable gland and screw the cable cap.

- Insert the other end of the battery power cable into the BAT connectors on the BMS:

Step2: Connect the other end of CAN communication cable to the


CAN port on BMS module which is marked in red.
Tighten the cable cap on the cable with rotation wrench.

CAN
+ BAT -

The wiring order of the communication cable is the same as RS485 communication cable - To dismantle the charging cable, please
operate it with slotted screwdriver as
Sequence 1 2 3 4 5 6 7 8 shown in the figure. Please DO NOT
unplug them directly with brute force!
CAN / GND / CAN_H CAN_L / A1 B1

VIII Ground Connection XI Commissioning


For one battery module: If all the battery packs are installed, please follow the following steps: DIP Configuration:
Unscrew the ground terminal with hexagon wrench on BMS and battery module at the two ground screws 1. Remove the side cover board of BMS; 0- Matching one battery module (default)
circled in red below. Connect the ground wire from BMS to battery module,. 2. Rotate the DIP to corresponding number with a small screwdriver 1- Matching two battery modules
accroding to the number of battery module(s) that has(have) been 2- Matching three battery modules
installed; 3- Matching four battery modules
Cable size: 10AWG.
3. Switch the breaker to ON;
4. Press the POWER button to turn on the T-BAT system;
5. Reinstall the side cover to BMS;
6. Power on the Inverter.
ring terminal 2 3

4
1
For 2~4 battery modules:
The terminal points for GND connection between battery modules are circled in red below.

Left side of batter y module Right side of batter y module