SERVICE REPORT

Reciprocating
Compressors

Report No 140386
Customer's Name & Address: Date 27-11-2024
The Krishna district Milk Producers
mutually aided co op union limited Service Engineer's Name Mr J Siva Raju
6-60/20 ,Administrative block MPF
,Krishna Machine Model NSPXI1007AE
Serial No PNB232178/S33297103
Date of Supplied 27-05-2023
Person Contacted : Name & Designation Date Commissioned 07-10-2023
Mr V.Srinivasrao
Maintenance incharge Previous date of visit 27-10-2024
Next Planned visit 27-12-2024
Landline / Mobile no. : 9440661248Mail Id
GST No 37AAAAT2578D1ZH
: [email protected]
Nature of Service : Inspection,Repairs

Product Complaint / Failure : Perodical service work comp no1

Work Done : Customer called visited above model air compressors at site and carried out following
replacement worn-out spares HP piston ring kit and air filter element and Oil wiper rings and all valves
servicing change the hp side suction and discharge valve service kits after completion of the service work
assembling same and fill the coolent and Oil upto gauge level and check the belts titing found good started
the compressor observed running condition and all working parameters are found good and loading
unloading found satisfactory Note inform to the customer please kindly check adt valves daily...
Air filter condition is good and no dust entry Yes Room temperature 35 °C
V belt tightness and alignment Yes Running Hours 4267
Recommended the required parts Yes Loading Hours 1375
CP Dryer condenser cleaning Yes Incoming Voltage 415 Volts
Disch Pr 6.5kg bar Comp.Disch Temp 38 °C Line current measured Amps
F/S Pr 2kg bar F/S Temp 89 °C Over load setting Amps
II S Pr 7kg bar II stage Temp °C Safe belt guard fitted Yes
III S Pr No bar III stage Temp °C Flow switch operation Yes

Next Service Due based on utilisation : 27-05-2025

Chicago Pneumatic compressors


Sveanagar, Dapodi www.cp.com
Pune 411012 Reach us @ 1800 200 0040
Parts Required for next service

Sl.No Part No Parts Description Quantity


1 Lp piston ring kit 1
2 Lp rider ring 1
3 Oil wiper rings 1
4 Lp suction valve service kits 2
5 Lp discharge valve service kits 2
6

10

11

12

13

14

15

Suggestion to improve energy efficiency: Smart Link


Customer's Remark : Your Mr J Siva Raju called on 09-11-2024 . He attended the job from 11-11-2024
to 11-11-2024. The work is Completed satisfactorily.
EMS Policy : Advised customer to dispose off following hazardous waste to approved agency for
proper disposal.
Recip Oil : 1 lts Ltrs Oil Filter : No Nos
Oil soaked cotton waste : 1kg Kg

Service carried out as per safety guidelines : Yes


Customer Remarks :
No
Name of Service Engineer : Mr J Siva Raju
Customer Name:
Mobile Number : 9550157001

Signature & Seal of the Firm


Signature