0% found this document useful (0 votes)
16 views5 pages

Comparateur PM2110 PM5110

Uploaded by

dadahanane80
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
16 views5 pages

Comparateur PM2110 PM5110

Uploaded by

dadahanane80
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 5

Compare Products

Items 1-2 of 2

Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications.
METSEPM5110 METSEPM2110

Power meter PowerLogic PM5110, modbus, up to EasyLogic PM2110, Power & Energy meter, Total
15th Harmonic, 1DO 33 alarms Harmonic, LED display, Pulse, class 1

View Details View Details

Main

Range PowerLogic EasyLogic

Product name PowerLogic PM5000 EasyLogic PM2100

Device short name PM5110 PM2110

Product or component type Power meter Power meter

Complementary

Power quality analysis Up to the 15th harmonic Total harmonic distortion

Device application Power monitoring Power monitoring


Sub billing

Type of measurement Current Total current harmonic distortion THD (I) per phase
Voltage Total voltage harmonic distortion THD (U) per phase
Frequency Apparent energy total
Power factor Active and reactive energy total
Energy Apparent power total
Active and reactive power Active and reactive power total
Current average
Voltage average
Frequency average
Power factor average

supply voltage 90...450 V AC 45...65 Hz


100...300 V DC

Network frequency 50 Hz 60 Hz
60 Hz 50 Hz

[In] rated current 1A 5A


5A 1A

type of network 1P + N
3P + N
3P

Maximum power consumption in VA 10 VA at 415 V 6 VA at 277 V AC

Ride-through time 80 ms 120 V AC typical 100 ms 120 V AC typical


100 ms 230 V AC typical 400 ms 230 V AC typical
100 ms 415 V AC typical 50 ms 125 V DC typical
50 ms 125 V DC typical

Display type Monochrome graphic LCD 7 segments LED

Display resolution 128 x 128 pixels

Sampling rate 64 samples/cycle 64 samples/cycle

Measurement current 50…8500 mA 5…6000 mA

1/5
Items 1-2 of 2

METSEPM5110 METSEPM2110

Power meter PowerLogic PM5110, modbus, up to EasyLogic PM2110, Power & Energy meter, Total
15th Harmonic, 1DO 33 alarms Harmonic, LED display, Pulse, class 1

input impedance Voltage (impedance 5 MOhm) Current (impedance <= 0.3 mOhm)
Current (impedance <= 0.3 mOhm) Voltage (impedance > 5 MOhm)

Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications.
Measurement voltage 35…760 V AC 45...65 Hz between phases 35…480 V AC 50/60 Hz between phases
20…440 V AC 45...65 Hz between phase and neutral 20…277 V AC 50/60 Hz between phase and neutral
480…999000 V AC 50/60 Hz with external VT

Frequency measurement range 45…65 Hz 45…65 Hz

Number of inputs 0 0

Measurement accuracy Active energy +/- 0.5 % Apparent power +/- 1 %


Reactive energy +/- 2 % Active energy +/- 1 %
Active power +/- 0.5 % Reactive energy +/- 1 %
Apparent power +/- 0.5 % Active power +/- 1 %
Frequency +/- 0.05 % Voltage +/- 0.5 %
Power factor +/- 0.5 Power factor +/- 0.01
Current +/- 0.5 % Current +/- 0.5 %
Voltage +/- 0.5 % Frequency +/- 0.05 %
Apparent energy +/- 0.5 %
Reactive power +/- 2 %

Accuracy class Class 0.5S active energy conforming to IEC 62053- Class 1 active energy conforming to IEC 62053-21
22 Class 1 reactive energy conforming to IEC 62053-24

Number of outputs 1 digital 1 pulse

Communication port protocol Modbus RTU and ASCII at 9.6, 19.2 and 38.4 kbauds POP
even/odd or none - 2 wires, insulation 2500 V
JBUS

Communication port support RS485

Data recording Time stamping


Min/max of instantaneous values

Connections - terminals Voltage circuit: screw terminal block4 Current transformer: screw connection (bottom) 6
Control circuit: screw terminal block2 Voltage inputs: screw connection (top) 4
Current transformer: screw terminal block6
Input/output circuit: screw terminal block6
RS485 link: screw terminal block4

Mounting mode Flush-mounted Clip-on

Mounting support Framework Framework

Standards UL 61010-1
EN 50470-3
EN 50470-1
IEC 62053-22
IEC 60529
IEC 62053-24
IEC 61557-12

Product certifications CE conforming to IEC 61010-1 CE conforming to IEC 61010-1


CULus conforming to UL 61010-1 CULus conforming to UL 61010-1
CULus conforming to CSA C22.2 No 61010-1
RCM
EAC
C-Tick

Width 96 mm 96 mm

Depth 72 mm 76.09 mm total:


61.64 mm embedded:

Height 96 mm 96 mm

Net weight 380 g 300 g

2/5
Items 1-2 of 2

METSEPM5110 METSEPM2110

Power meter PowerLogic PM5110, modbus, up to EasyLogic PM2110, Power & Energy meter, Total
15th Harmonic, 1DO 33 alarms Harmonic, LED display, Pulse, class 1

Metering type Peak demand power PM, QM, SM


Apparent power S, S1, S2, S3
Current I, I1, I2, I3

Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications.
Reactive power Q, Q1, Q2, Q3
Calculated neutral current
Voltage U, U21, U32, U13, V, V1, V2, V3
Peak demand currents
Unbalance current
Demand power P, Q, S
Active power P, P1, P2, P3
Active, reactive, apparent energy (signed, four
quadrant)

[Us] rated supply voltage 44...277 V AC 45...65 Hz +/- 10 %


44...277 V DC +/- 10 %

Maximum power consumption in W 3.3 W (power lines (AC))


2 W at 277 V (power lines (DC))

Tamperproof of settings Protected by access code

Display colour Red

messages display capacity 3 fields of 4 characters

Display digits 12 digit(s) - 14.2 mm in height

Demand intervals Configurable from 1 to 60 min

Information displayed Demand current (past value)


Demand current (present value)
Demand power (past value)
Demand power (present value)
Voltage
Current
Frequency
Energy consumption
Harmonic distortion
Power factor
Active power
Apparent power
Reactive power
Unbalanced in %

Control type 3 x button

Local signalling Red LED: output signal 1...9999000 pulse/ k_h (kWh,
kVAh, kVARh)
Green LED: module operating (RUN)

POP parameter Pulse: 20 ms (5...40 V DC, 20 mA max)1...9999000


pulse/ k_h (kWh, kVAh, kVARh)

Impulse duration 20 ms

Cybersecurity Enable/disable communication ports

Communication service Remote monitoring

Mounting position Vertical

Provided equipment 1 x installation guide

Measurement category Category III 480 V


Category II 480…600 V

Electrical insulation class Double insulation


Class II

Flame retardance V-0 conforming to UL 94

3/5
Items 1-2 of 2

METSEPM5110 METSEPM2110

Power meter PowerLogic PM5110, modbus, up to EasyLogic PM2110, Power & Energy meter, Total
15th Harmonic, 1DO 33 alarms Harmonic, LED display, Pulse, class 1

Material Polycarbonate

Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications.
Compatibility code PM2110

Environment

Electromagnetic compatibility Voltage dips and interruptions immunity test class A Electrostatic discharge conforming to IEC 61000-4-2
conforming to IEC 61000-4-11 Radiated radio-frequency electromagnetic field
Limits for harmonic current emissions class A immunity test conforming to IEC 61000-4-3
conforming to IEC 61000-3-2 Electrical fast transient/burst immunity test
Electrostatic discharge level 4 conforming to IEC conforming to IEC 61000-4-4
61000-4-2 Surge immunity test conforming to IEC 61000-4-5
Conducted RF disturbances level 3 conforming to Conducted RF disturbances conforming to IEC
IEC 61000-4-6 61000-4-6
Magnetic field at power frequency level 4 conforming Magnetic field at power frequency conforming to IEC
to IEC 61000-4-8 61000-4-8
Conducted and radiated emissions class B Voltage dips and interruptions immunity test
conforming to EN 55022 conforming to IEC 61000-4-11
Immunity to conducted disturbances - test level: 150 Emission tests conforming to FCC part 15 class A
kHz...80 MHz conforming to IEC 61000-4-6
Electrical fast transient/burst immunity test
conforming to IEC 61000-4-4
Radiated radio-frequency electromagnetic field
immunity test conforming to IEC 61000-4-3
Surge immunity test conforming to IEC 61000-4-5
Voltage dips and interruptions immunity test
conforming to IEC 61000-4-11

IP degree of protection IP54 display: conforming to IEC 60529 IP54 front: conforming to IEC 60529
IP30 rear: conforming to IEC 60529 IP30 body: conforming to IEC 60529

Relative humidity 5…95 % at 50 °C non-condensing

Pollution degree 2 2

Ambient air temperature for operation -25…70 °C meter


-20…70 °C display
-25…-20 °C (with reduced performance) display

Ambient air temperature for storage -40…85 °C -25…70 °C

Operating altitude 2000 m CAT III

Service life 7 year(s)

Relative humidity 5…95 % at 50 °C

Ambient air temperature for operation -10…60 °C

Operating altitude <= 2000 m

Overvoltage category III

Packing Units

Unit Type of Package 1 PCE PCE

Number of Units in Package 1 1 1

Package 1 Height 11.467 cm 11.94 cm

Package 1 Width 12.979 cm 12.19 cm

Package 1 Length 12.544 cm 9.14 cm

Package 1 Weight 449.0 g 0.41 kg

4/5
Items 1-2 of 2

METSEPM5110 METSEPM2110

Power meter PowerLogic PM5110, modbus, up to EasyLogic PM2110, Power & Energy meter, Total
15th Harmonic, 1DO 33 alarms Harmonic, LED display, Pulse, class 1

Unit Type of Package 2 S03

Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications.
Number of Units in Package 2 12

Package 2 Height 30.0 cm

Package 2 Width 30.0 cm

Package 2 Length 40.0 cm

Package 2 Weight 7.19 kg

Unit Type of Package 3 P12

Number of Units in Package 3 288

Package 3 Height 105.0 cm

Package 3 Width 80.0 cm

Package 3 Length 120.0 cm

Package 3 Weight 206.4 kg

Offer Sustainability

Sustainable offer status Green Premium product Green Premium product

REACh Regulation REACh Declaration REACh Declaration

EU RoHS Directive Compliant Compliant


EU RoHS Declaration EU RoHS Declaration

Mercury free Yes Yes

China RoHS Regulation China RoHS declaration China RoHS declaration

RoHS exemption information Yes Yes

Environmental Disclosure Product Environmental Profile Product Environmental Profile

Circularity Profile End of Life Information End of Life Information

WEEE The product must be disposed on European Union


markets following specific waste collection and never
end up in rubbish bins

California proposition 65 WARNING: Cancer and Reproductive Harm -


www.P65Warnings.ca.gov

5/5