01

02
03
EKOTEK HEAT TECHNOLOGIES
WHY CHOOSE?

Ekotek Heat Technologies to Production


Our product series, which we started by making digital
three-dimensional models and checking the suitability before
been passed for producton.
• After the necessary controls are made in the digital environment,
the TSE and CE CERTIFICATION Phase started and the product
you have requested has now started to gain a tangible identity by
meeting with the experience of Ekotek Heating Technologies.
• After this stage, we make safer production for you by blending
superior knowledge, quality products and technology.
• Thus, we have been a manufacturer and exporter of Steam
Boilers, Hot Oil Boilers, Hot Water Boilers, Solid (pellet, coal, wood,
etc.) and liquid / gas fueled household and Central Heating since
1999 and to transform the demands we have received into
experience and service.
• Over the years, we are excited to bring our products together
with you, both in Turkey and abroad, wherever there is a need.

04
With our wide product range, we offer our customers industrial or an
individual service.
• We make higher quality products with advanced technology in
production techniques.
• Every boiler we manufacture is subjected to hydrostatic test pressure
by our quality control engineers.
• The quality products are constructed by certified experienced welder. .
A perfect product is made with long-lasting properties by the outer
coating and ergonomic structure of our boilers.
Our products are easily recognizable. A developmental production that
never hesitates to receive professional support. With its dynamic R&D
team that follows all kinds of technological developments and
innovations, research and result-oriented production that aims to
improve day by day, and to provide better quality service to our
customers.

THE MOST IMPORTANT POINT MAKING EKOTEK Heat Technologies


DIFFERENT; In the MANUFACTURING OF STEAM AND HOT OIL
BOILERS, production is carried out on different designs by producing
according to TSE, CE, EN standards, and by providing internal control
by authorized institutions. It transforms your capital into maximum
power by paying attention to the fact that each material used in
production is certified products.
These are some of the justified reasons for organizations that
have adopted this understanding and use our company as a
preferred vendor
It is an honor for us to serve you as Ekotek heating
technologies, where technology and experience meet.
We exist to add strength to your industrial
power, we are stronger with you.

05
Our company is controlled and audited by EKOTEK, Brand registered and ISO 9001:2015 quality
management system.
For each product, module b (project) + module f (manufacturing) is certified with CE certificate
according to TSE Standard.
Welding processes are carried out by certified welders in accordance with approved WPS and
WPQRs. Welding processes are subjected to radiographic testing at the rates stipulated by the
standards. Ultrasonic, radiographic and penetrating tests are performed by the authorized
company for our resources.

THE PRODUCTS USED IN PRODUCTION ARE ALL CERTIFIED MATERIALS.

Our products are produced in accordance with 12953-2 Standard and 2014/68/EU Pressure Vessels directive and have CE
certificate.
Our products are manufactured in accordance with EN288, EN287-1 using P 265 GH and P 355 GH quality boiler sheet.
Our products are manufactured using boiler pipes made of P235GH and higher quality steel in accordance with TS EN
10217-2 norm.
Boiler pipes are pipes that have undergone normalization (stress relief annealing) heat treatment.

06
Steam boiler
A steam boiler is a machine or vessel in which a pressure vessel is subjected to heat and pressure and
the water in it passes from the liquid phase to the gas phase in a controlled manner. It is a device
used to create steam by applying heat energy to water. Steam boilers are systems that allow water to
evaporate by heating. Steam boilers fuel types are designed according to their working pressures. It
is a type of machine consisting of a pressure vessel that shapes everything we use and is used in
processing.

THE QUALITY OF THE FEED WATER IS AS IMPORTANT AS THE QUALITY OF THE STEAM BOILER. While purchasing a steam boiler, a lot of
emphasis is placed on its manufacturing quality, post-production pressure tests and operating efficiency. However, the life of this boiler,
its operating efficiency and the purity of the steam it produces are directly proportional to the purity of the water put into the boiler
rather than the manufacturing quality of the boiler. For this reason, it is necessary to act very knowledgeable in the preparation of the
steam boiler feed water, to select the necessary devices for the preparation of the feed water very carefully, and then to operate them
with the same meticulousness. Most of the problems experienced in the operation of the steam boiler (boiler and condensate system)
are related to the chemical quality of the water supplied to the boiler and called "feed water". The problems of the operator, who
underestimates the chemistry of the feed water and underestimates this feature, never diminishes. Get support from the treatment
companies in your region and our company for the feed water.
When choosing the boiler, it is necessary to consider the annual, monthly, daily and hourly steam needs of the enterprise.
Ekotek heat technologies designs different combustion systems specially for you. WE HAVE PRODUCTIONS WITH STOCKER -Helix/
Spiral, ROTATING GRATE AND PISTON MOVING GRATE.
Get Support from Engineering Firms for Central System Gas Opening Works.
Ekotek Heating Technologies recommends all the accessories and burner systems used in the package system steam boilers of the
brands known to be safe. Before choosing the package of gas fuel type industrial products, you should definitely inform our company
about the gas pressure coming to the main gas line used by your business. When choosing the burner, do not forget to connect a pe
max: 300 Mbar gas line or a Pe Max 21 Mbar Regulator to the burner according to the Main Gas pressure. Specify the information by
verifying it from your natural gas supplier company.
DO NOT FORGET TO HAVE CE AND TSE CERTIFIED CHIMNEY MADE FOR NATURAL GAS. DON'T FORGET TO GET A NATURAL GAS
SUITABLE CHIMNEY OFFER FROM OUR COMPANY.
5 types of safety systems are used in Ekotek Heating Technologies Steam boilers.
All designs of Ekotek heating technologies are special for you. In All Package Systems; All safety systems, including steam temperature,
mechanical pressure, digital pressure, safety valve, chimney temperature controls, as well as boiler feeding pumps, are used in double
standard packages.

07
08
09
STORM SERIES
175 kg/h-32.000 kg/h steam production capacity
Working pressure between 3 - 16 bar

Thanks to its large water and steam volume, it provides high performance in intense and continuous
working conditions and in sudden steam draws.
• Thanks to its high heating surface, it provides the opportunity to obtain drier and higher energy
steam.
• It offers comfortable and highly efficient combustion performance with its low counter pressure
values.
• It is produced as furnace and combustion chamber corrugated according to the pressure values.
The strength of the boiler and its resistance against thermal stresses have been increased in this way.
• Heat loss is prevented thanks to strong insulation with glass wool or rock wool.
• OUR COMPANY RECOMMENDS YOU TO USE AUTOMATIC BOTTOM Blowdown and SURFACE
Blowdown in the SYSTEM. (MANUAL BLUFFS ARE AVAILABLE IN PACKAGE SYSTEMS)
• WE RECOMMEND USING A DEGASER IN BOILER WORKING PRESSURE 8 BAR AND OVER.
• Ekotek Heating Technologies recommends all the accessories used in package system steam
boilers and burner systems of known brands.
• Ekotek Heating Technologies 5 types of safety systems are used in all steam boilers. All safety
systems, including steam temperature, mechanical pressure, digital pressure, safety valve, chimney
temperature controls, as well as boiler feeding pumps, are used in double standard packages.
• PLC control system can be added upon request.
• If you want to be in control, you should definitely see our optional options! Control your power with
Ekotek technology. With optional options; Plc Touch screen controlled, Modbus RTU
(Remote Terminal Unit Rtu) is completely under your control.
% 100 SAFE , USER-FRIENDLY

Min 145 kW - Max 23256 kW

10 www.ekotekkazan.com
LIQUID / GAS FUEL, THREE PASS, SCOTCH
HIGH PRESSURE STEAM BOILER

*Scotch type 3-pass boilers have taken the title of the longest-lasting and efficient boiler with their
superior designs accepted all over the world.
• Our boilers do not cause noise pollution with their silent operation.
• With its stylish appearance, it is noticed with its compatibility in the environment it is in.
• It is easy to assemble.
• Easy to Maintain.
• Upon request, our steam boilers can be delivered as a package with all its accessories.

CONDENSATE

APPROXIMATE
PROPERTIES
BOILER FLANGES RECOM. MIN.

INSULATION
CAPACITY

PRESSURE
COUNTER-
CHIMNEY
VOLUME

WEIGHT
WATER

DIMENSIONS ø
BLOWDOWN

TANK
BLOWDOWN

MIN.
SURFACE
OUTPUT

BOTTOM

MODEL
SAFETY

CAPACITY
WATER

Dimensions
STEAM

SMOKE
INLET

LIQUID
FUEL

FUEL
TUBE

GAS
BİRİM M² KCAL/H KW MW KG/H A B B1 C D E H H1 H2 K L LT DN DN DN DN DN LT MBAR øMM MM øMM øMM KG
STORM 5 5 125.000 145 0,15 175 2810 950 1150 650 1025 2100 1275 250 550 200 1500 650 32 25/40 32 40 32 45 5 57 -76,1 100 200 200 950

STORM 10 10 250.000 291 0,29 350 2910 980 1150 650 1080 2130 1330 250 550 250 1600 800 50 25/40 32 40 32 350 5 57 -76,1 100 300 250 1450

STORM 15 15 375.000 436 0,44 525 3205 1165 1150 650 1265 2315 1515 250 550 300 1895 1400 65 25/40 32 40 32 525 5 57 -76,1 100 350 300 1875

STORM 20 20 500.000 581 0,58 700 3220 1320 1150 650 1420 2470 1670 250 550 350 1910 2000 65 25/40 32 40 32 700 5 57 -76,1 100 400 350 2450

STORM 25 25 625.000 727 0,73 875 3300 1320 1150 650 1520 2470 1770 250 550 400 1990 2500 80 25/40 32 40 32 875 5 57 -76,1 100 400 400 3100

STORM 30 30 750.000 872 0,87 1050 3660 1420 1150 650 1620 2570 1870 250 550 450 2350 2750 80 25/40 32 40 32 1050 6 57 -76,1 100 450 450 3850

STORM 40 40 1.000.000 1163 1,16 1400 3660 1570 1150 650 1770 2720 2020 250 550 500 2350 2950 100 32/50 32 40 32 1400 7 57 -76,1 100 500 500 4700

STORM 50 50 1.250.000 1453 1,45 1750 4260 1670 1150 650 1870 2820 2120 250 550 550 2950 3800 100 32/50 32 40 32 1750 7 57 -76,1 100 550 550 5950

STORM 60 60 1.500.000 1744 1,74 2100 4500 1820 1150 650 2020 2970 2270 250 550 550 3190 4300 125 40/65 32 40 32 2100 8 57 -76,1 100 600 550 6100

STORM 70 70 1.750.000 2035 2,03 2450 4710 1820 1150 650 2020 2970 2270 250 550 600 3400 5500 125 40/65 32 40 32 2450 8 57 -76,1 100 650 600 7350

STORM 80 80 2.000.000 2326 2,33 2800 4855 1820 1150 700 2020 2970 2270 250 550 650 3545 6100 125 50/80 32 40 32 2800 8 57 -76,1 100 700 650 8100

STORM 100 100 2.500.000 2907 2,91 4000 5070 1970 1150 700 2170 3120 2470 300 550 700 3760 7300 150 50/80 32 40 32 3500 8 57 -76,1 100 750 700 9750

STORM 125 125 3.125.000 3634 3,63 5000 5530 2195 1200 700 2395 3395 2695 300 600 750 4220 8000 150 65/100 32 40 32 4375 8 57 -76,1 100 800 750 11200

STORM 150 150 3.750.000 4360 4,36 6000 5985 2200 1200 750 2400 3400 2700 300 600 800 4675 11000 200 65/100 32 40 32 5250 8 57 -76,1 100 850 800 12900

STORM 175 175 4.375.000 5087 5,09 7000 6270 2230 1200 750 2430 3430 2730 300 600 900 4960 12750 200 80/125 32 40 32 6125 8 57 -76,1 100 1100 900 14750

STORM 200 200 5.000.000 5814 5,81 8000 6330 2430 1200 750 2630 3630 2930 300 600 1000 5020 13200 200 80/125 40 40 32 7000 9 57 -76,1 100 1100 1000 16200

STORM 250 250 6.250.000 7267 7,27 10000 6600 2900 1200 850 3100 4100 3450 350 600 1100 5250 14500 250 80/125 40 40 32 8750 9 57 -76,1 100 1200 1000 18250

STORM 300 300 7.500.000 8721 8,72 12000 6950 2950 1200 850 3150 4150 3500 350 600 1300 5600 15750 250 100/150 40 40 32 10500 10 57 -76,1 100 1400 1300 20700

STORM 350 350 8.750.000 10174 10,17 14000 7380 3130 1200 850 3330 4330 3680 350 600 1400 6070 16500 250 100/150 40 40 32 12250 10 57 -76,1 100 1400 1500 23000

STORM 400 400 10.000.000 11628 11,63 16000 7000 3150 1200 850 3350 4350 3700 350 600 1500 5800 22500 300 100/150 50 40 32 14000 11 57 -76,1 100 1500 1500 24700

STORM 450** 450 11.250.000 13081 13,08 18000 7100 3400 1200 850 3600 4600 3950 350 600 1600 5850 25000 300 100/150 50 40 32 15750 11 57 -76,1 100 1600 1600 26200

STORM 500** 500 12.500.000 14535 14,53 20000 7550 3500 1200 850 3700 4700 4050 350 600 1600 6300 28375 300 100/150 50 40 32 17500 12 57 -76,1 100 1600 1600 28300

STORM600** 600 15.000.000 17442 17,44 24000 7700 3600 1200 950 3800 4800 4150 350 600 1800 6400 31750 300 100/150 50 40 32 21000 15 57 -76,1 100 1800 1800 31100

STORM 700** 700 17.500.000 20349 20,35 28000 8600 4050 1200 950 4250 5250 4600 350 600 2000 6900 35460 300 125/200 50 40 32 24500 17 57 -76,1 100 2000 2000 34870

STORM 800** 800 20.000.000 23256 23,26 32000 9700 4150 1200 950 4350 5350 4700 350 600 2100 7900 38700 300 125/200 50 40 32 28000 19 57 -76,1 100 2100 2100 39430

EKOTEK HEAT TECHNOLOGIES HAS THE RIGHT TO MAKE CHANGES IN DIMENSIONS, WEIGHTS AND MODELS
WITHOUT NOTICE ACCORDING TO THE CHANGE IN STANDARDS, DESIGN, ETC.
NOTE: The recommended chimney diameter is calculated as an average of 400 m altitude. The diameter of the chimney is the minimum size and may vary.
THE DATA IN THE TABLE IS MADE BASED ON 8 BAR PRESSURE. DATA MAY VARY DEPENDING ON PRESSURE.

Contact : +90 256 231 15 95 11


PERFORMANCE SERIES
200 kg/h-4000 kg/h steam production capacity
Working pressure between 3 - 16 bar

• In order to produce steam in a short time, the water volume is kept as small as possible and the
steam volume is large.
• Thanks to its high heating surface area, it provides the opportunity to obtain drier and higher
energy steam.
• High pressure (long-barrelled) burner should be used in 2-pass liquid/gas fueled boilers. When
choosing a burner, consider the counter pressure value and inform your burner company.
• In counter pressure steam boilers, the flame is separated from the boiler with 2 passes. The flame
that hits the rear wall comes back to the front cover and turns back from the front wall covered with
refractory material and leaves the boiler through pipes.
• It is highly efficient, since most of the energy of the fuel is used.
• Thanks to the strong insulation with rock wool, heat loss is prevented.
• OUR COMPANY RECOMMENDS YOU TO USE AUTOMATIC BOTTOM Blowdown and SURFACE
Blowdown in the SYSTEM.(Manual Blowdown Available in the Package System)
• Maximum efficiency and low flue temperature are obtained thanks to the smoke diverting
turbulators used in the boiler pipes.
• Thanks to the turbulators, the time and surface area of the flue gases in contact with the smoke
pipes are increased.
• WE RECOMMEND USING A DEGASER IN BOILER WORKING PRESSURE 8 BAR AND OVER.
• Ekotek Heating Technologies 5 types of safety systems are used in all steam boilers. All safety
systems, including steam temperature, mechanical pressure, digital pressure, safety valve, chimney
temperature controls, as well as boiler feeding pumps, are used in double standard packages.
• PLC control system can be added upon request.
• If you want to be in control, you should definitely see our optional options. Control your power with
Ekotek technology. With optional options; Plc Touch screen controlled, Modbus RTU (Remote
Terminal Unit Rtu) is completely under your control

% 100 SAFE , USER-FRIENDLY

Min 145 kW - Max 2907 kW

12 www.ekotekkazan.com
LIQUID / GAS FUEL, TWO PASS,
COUNTER PRESSURE,
HIGH PRESSURE STEAM BOILERS

• Combustion chamber dimensions; It has been designed in such a way that it will not cause harmful
emissions polluting the environment and the formation of Nox.
• Our boilers do not cause noise pollution with their silent operation.
• It is produced as furnace and combustion chamber corrugated according to the pressure values.
The strength of the boiler and its resistance against thermal stresses have been increased in this way.
• Smoke pipes are welded with mirrors and provide safer and long-lasting operation.
• Safe with smoke chest, blasting cover and clear cover.
• It provides ease of operation and maintenance, minimum fuel consumption and reduction of
operating expenses thanks to the burner burning control.
• Due to the appropriate size of the boiler, it can be easily placed in any environment.
• With its stylish appearance, it is noticed with its compatibility in the environment it is in.
• It is easy to assemble.
• Easy to Maintain.
• Upon request, our steam boilers can be delivered as a package with all its accessories.

CONDENSATE

APPROXIMATE
PROPERTIES

BOILER FLANGES RECOM. MIN.


INSULATION
CAPACITY

PRESSURE
COUNTER-

CHIMNEY
VOLUME

WEIGHT
WATER

DIMENSIONS ø
BLOWDOWN

TANK
BLOWDOWN

MIN.
SURFACE
SAFETY
OUTPUT

BOTTOM

MODEL
WATER

CAPACITY Dimensions
STEAM

SMOKE
INLET

LIQUID
FUEL

FUEL

TUBE
GAS

BİRİM M² KCAL/H KW MW KG/H A B B1 C D H H1 K L LT DN DN DN DN DN LT MBAR øMM MM øMM øMM KG


PERFORMANCE 5 5 125.000 145 0,15 200 1950 950 1000 450 800 1150 520 200 1500 520 40 25/40 32 40 32 200 3,5 57 100 200 200 1365

PERFORMANCE 10 10 250.000 291 0,29 400 2250 1120 1000 500 970 1320 520 250 1745 872 50 25/40 32 40 32 400 3,5 57 100 300 250 1670

PERFORMANCE 15 15 375.000 436 0,44 600 2650 1250 1000 700 1100 1450 520 300 1950 1149 65 25/40 32 40 32 600 6,5 57 100 350 300 1980

PERFORMANCE 20 20 500.000 581 0,58 800 2800 1320 1000 750 1170 1520 520 350 2050 1465 65 25/40 32 40 32 800 6,5 57 100 400 350 2100

PERFORMANCE 25 25 625.000 727 0,73 1000 2950 1375 1000 805 1225 1575 520 400 2145 2100 80 25/40 32 40 32 1000 6,5 57 100 400 400 2650

PERFORMANCE 30 30 750.000 872 0,87 1200 3000 1420 1000 800 1270 1620 520 450 2200 2570 100 32/50 32 40 32 1200 6,5 57 100 450 450 3200

PERFORMANCE 40 40 1.000.000 1163 1,16 1600 3100 1600 1100 850 1450 1800 520 500 2250 2982 100 32/50 32 40 32 1600 7 57 100 500 500 3580

PERFORMANCE 50 50 1.250.000 1453 1,45 2000 3200 1700 1100 850 1550 1900 520 550 2350 3425 125 40/65 32 40 32 2000 7 57 100 550 550 3890

PERFORMANCE 60 60 1.500.000 1744 1,74 2400 3350 1790 1100 850 1640 1990 520 550 2500 3795 125 40/65 32 40 32 2400 7,5 57 100 600 550 4160

PERFORMANCE 70 70 1.750.000 2035 2,03 2800 3600 1860 1100 850 1710 2060 520 600 2750 4160 125 50/80 32 40 32 2800 8 57 100 650 600 4505

PERFORMANCE 80 80 2.000.000 2326 2,33 3200 3850 1960 1100 850 1810 2160 520 650 3000 4630 150 50/80 32 40 32 3200 8,5 57 100 700 650 4850

PERFORMANCE 90 90 2.250.000 2616 2,62 3600 4100 2010 1150 950 1860 2210 520 650 3150 5040 150 50/80 32 40 32 3600 8,5 76,1 100 700 650 5145

PERFORMANCE 100 100 2.500.000 2907 2,91 4000 4450 2010 1150 1000 1860 2210 520 700 3450 5625 150 50/80 32 40 32 4000 9 76,1 100 750 700 5640

EKOTEK HEAT TECHNOLOGIES HAS THE RIGHT TO MAKE CHANGES IN DIMENSIONS, WEIGHTS AND MODELS
WITHOUT NOTICE ACCORDING TO THE CHANGE IN STANDARDS, DESIGN, ETC.
NOTE: The recommended chimney diameter is calculated as an average of 400 m altitude. The diameter of the chimney is the minimum size and may vary.
THE DATA IN THE TABLE IS MADE BASED ON 8 BAR PRESSURE. DATA MAY VARY DEPENDING ON PRESSURE.

Contact : +90 256 231 15 95 13


SHIELD SERIES
400 kg/h-16.000 kg/h steam production capacity
Working pressure between 3 - 16 bar

• It offers comfortable and highly efficient combustion performance with its low counter pressure
values.
• With its 3-pass design, the combustion surface is used in the most efficient way by ensuring the
contact of the flame smoke with the entire combustion surface.
• Heat loss is prevented thanks to strong insulation with glass wool, rock wool and ceramics.
• Ekotek Heating Technologies recommends all the accessories used in package system steam
boilers and burner systems of known brands.
• Ekotek Heating Technologies 5 types of safety systems are used in all steam boilers. All safety
systems, including steam temperature, mechanical pressure, digital pressure, safety valve, chimney
temperature controls, as well as boiler feeding pumps, are used in double standard packages.
• PLC control system can be added upon request.
• If you want to be in control, you should definitely see our optional options. Control your power with
Ekotek technology. With optional options; Plc Touch screen controlled, Modbus RTU (Remote
Terminal Unit Rtu) is completely under your control.

% 100 SAFE , USER-FRIENDLY

Min 291 kW - Max 11628 kW

14 www.ekotekkazan.com
FLAME - SMOKE TUBE,
THREE PASS, STEAM GENERATOR

• There is no risk of explosion.


• Our boilers do not cause noise pollution with their silent operation.
• With its stylish appearance, it is noticed with its compatibility in the environment it is in.
• It is easy to assemble.
• Easy to maintain
• Upon request, our steam boiler can be delivered as a package with all its accessories.
• Every stage of our production is carried out under assurance by our quality control teams.

CONDENSATE

APPROXIMATE
PROPERTIES
BOILER FLANGES RECOM. MIN.
INSULATION
CAPACITY

PRESSURE
COUNTER-

CHIMNEY
VOLUME

WEIGHT
WATER

DIMENSIONS ø
BLOWDOWN

TANK
BLOWDOWN

MIN.
SURFACE
OUTPUT

BOTTOM
SAFETY

MODEL CAPACITY
WATER
STEAM

Dimensions SMOKE
INLET

LIQUID
FUEL

FUEL
TUBE

BİRİM M² KCAL/H KW MW KG/H A B B1 H H1 H2 K L LT DN DN DN DN DN LT MBAR øMM MM øMM øMM GAS KG


SHIELD 10 10 250.000 291 0,29 400 2150 1100 1000 2500 1950 550 250 1450 840 50 25/40 32 40 32 500 1 57-76,1 100 300 250 1360

SHIELD 15 15 375.000 436 0,44 600 2550 1170 1000 2550 2050 550 300 1850 970 65 25/40 32 40 32 750 1 57-76,1 100 350 300 1850

SHIELD 20 20 500.000 581 0,58 800 2800 1250 1000 2900 2350 550 350 2100 1055 65 25/40 32 40 32 1000 1 57-76,1 100 400 350 2270

SHIELD 25 25 625.000 727 0,73 1000 3100 1325 1000 3050 2500 550 400 2400 1230 80 25/40 32 40 32 1000 1 57-76,1 100 400 400 2950

SHIELD 30 30 750.000 872 0,87 1200 3250 1410 1000 3170 2620 550 400 2550 1650 100 32/50 32 40 32 1250 1 57-76,1 100 450 450 3780

SHIELD 35 35 875.000 1017 1,02 1400 3350 1450 1000 3400 2850 550 450 2650 1980 100 32/50 32 40 32 1500 1,1 57-76,1 100 500 500 4350

SHIELD 40 40 1.000.000 1163 1,16 1600 3500 1500 1000 3700 3150 550 500 2550 2370 100 32/50 32 40 32 1750 1,1 57-76,1 100 550 550 5200

SHIELD 50 50 1.250.000 1453 1,45 2000 3500 1550 1000 3700 3150 550 550 2550 2715 125 40/65 32 40 32 2000 1,35 57-76,1 100 600 550 5700

SHIELD 60 60 1.500.000 1744 1,74 2400 4050 1670 1000 3850 3300 550 550 3100 2950 125 40/65 32 40 32 2500 1,35 57-76,1 100 650 600 6350

SHIELD 70 70 1.750.000 2035 2,03 2800 4200 1750 1000 3900 3350 550 600 3300 3185 125 50/80 32 40 32 3000 1,35 57-76,1 100 700 650 7250

SHIELD 80 80 2.000.000 2326 2,33 3200 4350 1770 1000 4000 3450 550 650 3450 3950 150 50/80 32 40 32 3500 1,5 57-76,1 100 700 650 7900

SHIELD 90 90 2.250.000 2616 2,62 3600 4550 1850 1000 4100 3550 550 650 3600 4700 150 50/80 32 40 32 4000 1,5 57-76,1 100 750 700 8650

SHIELD 100 100 2.500.000 2907 2,91 4000 4700 1925 1000 4170 3620 550 700 3750 5180 150 50/80 32 40 32 4000 1,7 57-76,1 100 750 700 9150

SHIELD 125 125 3.125.000 3634 3,63 5000 5100 2000 1000 4350 3800 550 750 4100 6900 150 65/100 32 40 32 5000 1,7 57-76,1 100 800 750 10500

SHIELD 150 150 3.750.000 4360 4,36 6000 5350 2100 1000 4600 4050 550 800 4500 8400 200 65/100 32 40 32 6000 1,85 57-76,1 100 850 800 11320

SHIELD 175 175 4.375.000 5087 5,09 7000 5700 2200 1000 4700 4150 550 900 4750 9150 200 80/125 32 40 32 7000 2 57-76,1 100 1000 900 12200

SHIELD 200 200 5.000.000 5814 5,81 8000 6000 2250 1000 4850 4300 550 1000 5050 9950 200 80/125 40 40 32 8000 2 57-76,1 100 1100 1000 13000

SHIELD 250 250 6.250.000 7267 7,27 10000 6500 2375 1000 4950 4400 550 1100 5400 10750 250 80/125 40 40 32 10000 2,15 57-76,1 100 1200 1100 14100

SHIELD 300 300 7.500.000 8721 8,72 12000 7000 2450 1000 5100 4550 550 1300 5750 11300 250 100/150 40 40 32 12000 2,5 57-76,1 100 1400 1300 15000

SHIELD 350 350 8.750.000 10174 10,17 14000 7400 2600 1000 5150 4650 550 1500 6100 12100 250 100/150 40 40 32 14000 2,5 57-76,1 100 1500 1400 15600

SHIELD 400 400 10.000.000 11628 11,63 16000 7850 2650 1000 5250 4750 550 1500 6500 14000 300 100/150 50 40 32 16000 2,85 57-76,1 100 1600 1500 16250
EKOTEK HEAT TECHNOLOGIES HAS THE RIGHT TO MAKE CHANGES IN DIMENSIONS, WEIGHTS AND MODELS
WITHOUT NOTICE ACCORDING TO THE CHANGE IN STANDARDS, DESIGN, ETC.
NOTE: The recommended chimney diameter is calculated as an average of 400 m altitude. The diameter of the chimney is the minimum size and may vary.

THE DATA IN THE TABLE IS MADE BASED ON 8 BAR PRESSURE. DATA MAY VARY DEPENDING ON PRESSURE.

Contact : +90 256 231 15 95 15


FLASH SERIES
150 kg/h - 6.000 kg/h steam production capacity
Working pressure between 3 - 16 bar

• It offers comfortable and highly efficient combustion performance with its low counter pressure
values.
• The 3-pass design ensures the contact of the flame smoke with the entire combustion surface, and
the combustion surface is used in the most efficient way.
• Serpentine has a longer life than generators.
• Operating costs are 10-15% lower than serpentine generators.
• Heat loss is prevented thanks to strong insulation with glass wool, rock wool and ceramics.
• Ekotek Heating Technologies recommends all the accessories used in package system steam
boilers and burner systems of known brands.
• Ekotek Heating Technologies 5 types of safety systems are used in all steam boilers. All safety
systems, including steam temperature, mechanical pressure, digital pressure, safety valve, chimney
temperature controls, as well as boiler feeding pumps, are used in double standard packages.
• PLC control system can be added upon request.
• If you want to be in control, you should definitely see our optional options. Control your power with
Ekotek technology. With optional options, Plc Touch screen controlled, Modbus (RTU Remote
Terminal Unit) is completely under your control.

% 100 SAFE , USER-FRIENDLY

Min 291 kW - Max 11628 kW

16 www.ekotekkazan.com
LIQUID / GAS FUEL, THREE PASS,
STEAM GENERATOR

• There is no risk of explosion.


• Our boilers do not cause noise pollution with their silent operation.
• With its stylish appearance, it is noticed with its compatibility in the environment it is in.
• It is easy to assemble.
• Easy to maintain
• Upon request, our steam generators can be delivered with all accessories as a package.
• Every stage of our production is carried out under assurance by our quality control teams.

CONDENSATE

APPROXIMATE
BOILER FLANGES
PROPERTIES

RECOM. MIN.
INSULATION
CAPACITY

PRESSURE
COUNTER-

CHIMNEY

WEIGHT
VOLUME

DIMENSIONS ø
TANK
WATER

MIN.
OUTPUT

SAFETY

WATER

MODEL
STEAM

CAPACITY
INLET

Dimensions
LIQUID
FUEL

FUEL
GAS

BİRİM M² KCAL/H KW MW KG/H A B H H1 K L LT DN DN DN LT MBAR MM øMM øMM KG


FLASH 150 7,5 90.000 105 0,10 150 1750 1150 1400 1150 170 1500 41 25 32/50 32 150 0,9 100 180 180 750
FLASH 250 10 150.000 174 0,17 250 1850 1150 1400 1150 200 1600 56 32 32/50 32 250 1,2 100 225 200 830
FLASH 350 13,5 210.000 244 0,24 350 2050 1350 1600 1350 225 1800 102 40 32/50 32 350 1,5 100 250 225 935
FLASH 500 17 300.000 349 0,35 500 2250 1400 1650 1400 300 2000 127 40 32/50 32 500 1,8 100 300 300 1220
FLASH 750 24 450.000 523 0,52 750 2450 1450 1700 1450 350 2200 183 50 32/50 32 750 2,1 100 350 350 1750
FLASH 1000 29 600.000 698 0,70 1000 2600 1600 1850 1600 400 2350 220 50 35/50 32 1000 2,4 100 400 400 1900

FLASH 1250 35 750.000 872 0,87 1250 3000 1600 1850 1600 450 2750 293 65 32/50 32 1250 2,7 100 450 450 2150
FLASH 1500 42 900.000 1047 1,05 1500 3200 1700 2000 1700 450 2950 350 65 40/65 32 1500 3 100 500 450 2800

FLASH 1750 45 1.050.000 1221 1,22 1750 3250 1750 2050 1750 500 3000 370 80 40/65 32 1750 3,3 100 500 500 3000
FLASH 2000 50 1.200.000 1395 1,40 2000 3300 1800 2100 1800 550 3050 415 80 50/80 32 2000 3,6 100 550 550 3350

FLASH 2500 73 1.500.000 1744 1,74 2500 3950 1950 2250 1950 550 3700 750 80 50/80 32 2500 4,2 100 600 550 4500
FLASH 3000 78 1.800.000 2093 2,09 3000 4150 2000 2300 2000 600 3900 803 80 50/80 32 3000 5 100 650 600 4950
FLASH 3500 92 2.100.000 2442 2,44 3500 4650 2250 2550 2250 650 4400 885 100 50/80 32 3500 6,3 100 700 650 5600
FLASH 4000 105 2.400.000 2791 2,79 4000 4900 2350 2650 2350 700 4650 1210 100 65/100 32 4000 6,5 100 750 700 6570
FLASH 5000 120 3.000.000 3488 3,49 5000 5400 2600 2900 2600 750 5150 1350 125 65/100 32 5000 6,7 100 800 750 7500
FLASH 6000 150 3.600.000 4186 4,19 6000 5650 2750 3050 2750 800 5400 2000 125 65/100 32 6000 7,1 100 850 800 8100

EKOTEK HEAT TECHNOLOGIES HAS THE RIGHT TO MAKE CHANGES IN DIMENSIONS, WEIGHTS AND MODELS
WITHOUT NOTICE ACCORDING TO THE CHANGE IN STANDARDS, DESIGN, ETC.
NOTE: The recommended chimney diameter is calculated as an average of 400 m altitude. The diameter of the chimney is the minimum size and may vary.
THE DATA IN THE TABLE IS MADE BASED ON 8 BAR PRESSURE. DATA MAY VARY DEPENDING ON PRESSURE.

Contact : +90 256 231 15 95 17


STRONG SERIES
7000 kg/h-40.000 kg/h steam production capacity
Working pressure between 6 - 30 bar

• It offers comfortable and highly efficient combustion performance with its low counter pressure
values.
• With its 3-pass design, the combustion surface is used in the most efficient way by ensuring the
contact of the flame smoke with the entire combustion surface.
• Heat loss is prevented thanks to strong insulation with glass wool, rock wool and ceramics.
• Ekotek Heating Technologies recommends all the accessories used in package system steam
boilers and burner systems of known brands.
• Ekotek Heating Technologies 5 types of safety systems are used in all steam boilers. All safety
systems, including steam temperature, mechanical pressure, digital pressure, safety valve, chimney
temperature controls, as well as boiler feeding pumps, are used in double standard packages.
• PLC control system can be added upon request.
• If you want to be in control, you should definitely see our optional options. Control your power with
Ekotek technology. With optional options; Plc Touch screen controlled, Modbus RTU
(Remote Terminal Unit Rtu) completely under your control

% 100 SAFE , USER-FRIENDLY

Min 5232 kW - Max 29069 kW

18 www.ekotekkazan.com
LIQUID / GAS FUEL, D TYPE
HIGH PRESSURE STEAM BOILER

• There is no risk of explosion.


• Our boilers do not cause noise pollution with their silent operation.
• With its stylish appearance, it is noticed with its compatibility in the environment it is in.
• It is easy to assemble.
• Easy to maintain
• Upon request, our steam generators are delivered together with all their accessories as a package.
can be done.
• Every stage of our production is carried out under assurance by our quality control teams.

APPROXIMATE

BOILER FLANGES
PROPERTIES
CONDENSATE

RECOM. MIN.
INSULATION

CHIMNEY
CAPACITY

WEIGHT
VOLUME

DIMENSIONS ø
WATER

BLOWDOWN
BLOWDOWN

TANK
OUTPUT

MIN.
SAFETY

SURFACE
WATER

MODEL CAPACITY
STEAM

BOTTOM

Dimensions WATER
INLET

LIQUID
FUEL

FUEL

PIPES
GAS

BİRİM M² KCAL/H KW MW KG/H A B H L K LT DN DN DN DN DN LT øMM MM øMM øMM KG


STRONG 5 175 4.500.000 5232 5,23 7000 5700 3650 4500 3600 900 15750 200 65/100 32 40 32 5000 57 - 76,1 150 1100 900 20700

STRONG 8 250 6.250.000 7267 7,27 10000 6000 3650 4600 3650 1200 16200 250 80/125 32 40 32 8000 57 - 76,1 150 1200 1000 21700

STRONG 12 350 8.750.000 10174 10,17 14000 6150 3650 4800 3750 1400 18700 250 100/150 32 40 32 10000 57 - 76,1 150 1400 1500 24000

STRONG 15 500 12.500.000 14534 14,53 20000 7250 4000 5100 4200 1600 22500 300 100/150 32 40 32 15000 57 - 76,1 150 1600 1600 32000

STRONG 18 600 15.000.000 17441 17,44 24000 7800 4100 5100 4200 1850 23750 300 100/150 32 40 32 20000 57 - 76,1 150 1850 1850 34500

STRONG 20 675 17.000.000 19767 19,77 27000 8250 4300 5100 4200 2000 25000 300 100/150 32 40 32 20000 57 - 76,1 150 2000 2000 37000

STRONG 25 835 20.000.000 23255 23,26 33400 8750 5100 6200 5000 2100 28375 300 125/200 32 40 32 25000 57 - 76,1 150 2100 2100 42000

STRONG 30 1000 25.000.000 29069 29,07 40000 9300 5450 6400 5300 2300 31750 300 150/250 32 40 32 30000 57 - 76,1 150 2300 2300 46000

EKOTEK HEAT TECHNOLOGIES HAS THE RIGHT TO MAKE CHANGES IN DIMENSIONS, WEIGHTS AND MODELS
WITHOUT NOTICE ACCORDING TO THE CHANGE IN STANDARDS, DESIGN, ETC.

NOTE: The recommended chimney diameter is calculated as an average of 400 m altitude. The diameter of the chimney is the minimum size and may vary.

THE DATA IN THE TABLE IS MADE BASED ON 8 BAR PRESSURE. DATA MAY VARY DEPENDING ON PRESSURE.

Contact : +90 256 231 15 95 19


THE GRIM SERIES
160 kg/h-5.600 kg/h steam production capacity
Working pressure between 3 - 16 bar

• LIGNITE COAL, PAIN, PELLET, SUNFLOWER SHELLS, HAZELNUT SHELLS, etc. It can burn granular
fuels with high efficiency and its use is facilitated by automatic loading.
• If requested, an economizer can be added to the flue gas outlet in order to benefit from the heat of
the flue gases. The economizer to be mounted at the back of the boiler allows the condensate water
entering the boiler to be heated and returned to the boiler. Thus, fuel savings are achieved.
• It has the flexibility to work in harmony with different combustion systems.
• Our boilers are designed for minimum 4.500 kcal/h (flame temperature 1200 C°) fuel. Please contact
our company to burn lower calorie fuel.
• Ekotek Heating Technologies 5 types of safety systems are used in all steam boilers. All safety
systems, including steam temperature, mechanical pressure, digital pressure, safety valve, chimney
temperature controls, as well as boiler feeding pumps, are used in double standard packages.
• If you want to be in control, you should definitely see our optional options. Control your power with
Ekotek technology. With optional options; Plc touch screen controlled,
Modbus RTU (Remote Terminal Unit Rtu) is completely under your control.
• Thanks to its high heating surface, it provides the opportunity to obtain drier and higher energy
steam.
• Thanks to its large water and steam volume, it provides high performance in intense and
continuous working conditions and in sudden steam draws.
• WE RECOMMEND USING A DEGASER IN BOILER WORKING PRESSURE 8 BAR AND OVER.
• OUR COMPANY RECOMMENDS YOU TO USE AUTOMATIC DIB BLOWdown AND SURFACE
BLOWdown IN THE SYSTEM. (MANUAL BLUFFS ARE AVAILABLE IN PACKAGE SYSTEMS)
• It offers comfortable and highly efficient combustion performance with its low counter pressure
values.
• Scotch type 3-pass boilers have received the title of the longest-lasting and efficient boiler with
their superior designs accepted all over the world.
• Fuel supply is from the bottom and direct contact of the flame with the combustion chamber is
provided.
• Fan assist and primary air; It provides a controlled and clean smokeless combustion.
% 100 SAFE , USER-FRIENDLY

Min 112 kW - Max 3907 kW

20 www.ekotekkazan.com
SOLID FUEL, THREE PASS, SCOTCH TYPE
HIGH PRESSURE STEAM BOILERS

• Our boilers do not cause noise pollution with their silent operation.
• It is produced as corrugated furnace and combustion chamber according to the pressure values.
The strength of the boiler and its resistance against thermal stresses have been increased in this way.
• Smoke pipes are welded with mirrors and provide safer and long-lasting operation.
• Heat loss is prevented thanks to strong insulation with glass wool and rock wool.
• With its stylish appearance, it is noticed with its compatibility in the environment it is in.
• Easy to install.
• Easy to Maintain.
• There is no risk of explosion.
• Upon request, our steam boilers can be delivered as a package with all accessories.
• For systems that burn pellets, powder fuel, wood chips, etc. for different fuel types, please contact
us!

TANK CAPACITY
FUEL

DIMENSIONS ø

APPROXIMATE
CONDENSATE
BOILER FLANGES

RECOM. MIN.
PROPERTIES
TANK

INSULATION

CHIMNEY
VOLUME

PRESSURE

WEIGHT
COUNTER-
WATER

CAPACITY
BLOWDOWN
BLOWDOWN

SMOKE
MIN.
SURFACE
OUTPUT

TUBE
SAFETY

WATER

BOTTOM

MODEL CAPACITY
STEAM

Dimensions
INLET

POMANCE
OLIVE
COAL

BİRİM M² KCAL/H KW MW KG/H A B B1 C D E H H1 H2 K L L1 LT DN DN DN DN DN KG KG LT MBAR øMM MM øMM KG


GRIM 10A 10 96.000 112 0,11 160 3650 1070 1200 600 1270 2270 1650 300 550 225 1700 1350 920 32 25/40 32 40 32 150 125 160 4,5 76,1 100 225 2000
GRIM 15A 15 144.000 167 0,17 240 4100 1250 1200 600 1450 2450 1860 300 550 250 1900 1600 1400 40 25/40 32 40 32 150 125 240 5 76,1 100 250 2400

GRIM 20A 20 192.000 223 0,22 320 4400 1410 1200 600 1610 2610 2010 300 550 300 2050 1750 2000 50 25/40 32 40 32 150 125 320 5 76,1 100 300 2800
GRIM 25A 25 240.000 279 0,28 400 4470 1410 1200 600 1610 2610 2010 300 550 350 2120 1750 2500 50 25/40 32 40 32 150 125 400 5 76,1 100 350 3300

GRIM 30A 30 288.000 335 0,33 480 4650 1470 1200 600 1670 2670 2070 300 550 350 2300 1750 2750 65 25/40 32 40 32 200 175 480 5 76,1 100 350 4000

GRIM 40A 40 384.000 447 0,45 640 5100 1720 1200 600 1920 2920 2250 300 550 450 2500 2000 2950 65 25/40 32 40 32 200 175 640 6,7 76,1 100 450 5000

GRIM 50A 50 480.000 558 0,56 800 5600 1900 1200 750 2100 3100 2450 300 550 450 2850 2000 3800 65 25/40 32 40 32 200 175 800 7 76,1 100 450 6200
GRIM 60A 60 576.000 670 0,67 960 6150 2050 1200 750 2250 3250 2620 300 550 500 3400 2000 4300 80 25/40 32 40 32 200 175 960 8 76,1 100 500 6500

GRIM 70A** 70 672.000 781 0,78 1120 6500 2150 1200 750 2350 3350 3060 300 550 550 3500 2250 5500 80 32/50 32 40 32 200 175 1120 8 76,1 100 550 7200

GRIM 80A** 80 768.000 893 0,89 1280 6550 2250 1200 750 2450 3450 3100 300 550 550 3550 2250 6100 100 32/50 32 40 32 200 175 1280 8 76,1 100 550 8000
GRIM 90A** 90 864.000 1005 1,00 1440 6550 2450 1200 750 2650 3650 3150 300 550 600 3250 2500 6730 100 32/50 32 40 32 200 175 1440 8 76,1 100 600 8750

GRIM 100A** 100 960.000 1116 1,12 1600 6750 2550 1200 750 2750 3750 3400 300 550 600 3500 2500 7300 100 32/50 32 40 32 400 350 1600 8 76,1 100 600 9500

GRIM 125A** 125 1.200.000 1395 1,40 2000 7250 2600 1200 750 2800 3800 3400 300 550 650 4000 2500 8000 125 40/65 32 40 32 400 350 2000 8 76,1 100 650 11000

GRIM 150A** 150 1.440.000 1674 1,67 2400 7750 2670 1200 850 2870 3870 3600 300 550 700 4250 2750 11000 125 50/80 32 40 32 400 350 2400 8 76,1 100 700 12500
GRIM 175A** 175 1.680.000 1953 1,95 2800 8400 2700 1200 850 2900 3900 3600 300 550 750 4700 2900 12750 125 50/80 32 40 32 400 350 2800 8 76,1 100 750 13250

GRIM 200A** 200 1.920.000 2233 2,23 3200 8650 2800 1200 850 3000 4000 3600 300 550 800 4900 2900 13200 150 50/80 32 40 32 400 350 3200 8 76,1 100 800 14500
GRIM 250A** 250 2.400.000 2791 2,79 4000 9200 2800 1200 850 3000 4000 3600 300 600 900 5450 2900 14500 150 65/100 32 40 32 400 350 4000 9 76,1 100 900 15000

GRIM 300A** 300 2.880.000 3349 3,35 4800 9800 3020 1200 850 3220 4250 3850 300 600 1000 6050 2900 15700 200 65/100 32 40 32 400 350 4800 9 76,1 100 1000 16350

GRIM 320A** 320 3.072.000 3572 3,57 5120 10000 3100 1200 900 3300 4300 3900 300 600 1000 6500 2900 16750 200 65/100 32 40 32 400 350 5120 9 76,1 100 1000 17350

GRIM 350A** 350 3.360.000 3907 3,91 5600 10250 3150 1200 900 3350 4350 3950 300 600 1100 6600 2900 17890 200 65/100 32 40 32 400 350 5600 9 76,1 100 1100 18600

EKOTEK HEAT TECHNOLOGIES HAS THE RIGHT TO MAKE CHANGES IN DIMENSIONS, WEIGHTS AND MODELS
WITHOUT NOTICE ACCORDING TO THE CHANGE IN STANDARDS, DESIGN, ETC.
NOTE: The recommended chimney diameter is calculated as an average of 400 m altitude. The diameter of the chimney is the minimum size and may vary.

THE DATA IN THE TABLE IS MADE BASED ON 8 BAR PRESSURE. DATA MAY VARY DEPENDING ON PRESSURE.

Contact : +90 256 231 15 95 21


THUNDERBOLT SERIES
160 kg/h - 3200 kg/h steam production capacity
Working pressure between 3 – 16 bar

• Thanks to its large water and steam volume, it provides high performance in intense and
continuous working conditions and sudden steam withdrawals.
• Thanks to its high heating surface, it provides the opportunity to obtain drier and higher energy
steam.
• It offers comfortable and highly efficient combustion performance with its low counter pressure
values.
• Thanks to its 3-pass design, it distributes the heat obtained equally to all surfaces, providing
maximum heat transfer and fuel savings.
• Fuel supply is from the bottom and direct contact of the flame with the combustion chamber is
provided.
• Our boilers do not cause noise pollution with their silent operation.
• Air sent to the primary with the help of a fan; It provides a controlled and clean smokeless
combustion.
• Design and Manufacturing upper pressure limit in Half Cylindrical Steam Boilers has been
determined as 8 Bar;
In order to meet customer expectations, it can be manufactured by increasing the production
capacity range according to the needs.
• OUR COMPANY RECOMMENDS YOU TO USE AUTOMATIC DIB BLOWdown AND SURFACE
BLOWdown IN THE SYSTEM.
(MANUAL BLOWFLOWS ARE AVAILABLE IN PACKAGE SYSTEMS)
• Ekotek Heating Technologies 5 types of safety systems are used in all steam boilers. All safety
systems, including steam temperature, mechanical pressure, digital pressure, safety valve, chimney
temperature controls, as well as boiler feeding pumps, are used in double standard packages.

% 100 SAFE , USER-FRIENDLY

Min 112 kW - Max 2233 kW

22 www.ekotekkazan.com
SOLID FUEL, THREE PASS,
SEMI CYLINDRICAL
STEAM BOILERS

• Smoke tubes are welded with mirrors and provide safer and long-lasting operation.
• Heat loss is prevented thanks to strong insulation with glass wool or rock wool.
• Digital Analog or optional PLC control panel.
• With its stylish appearance, it is noticed with its compatibility in the environment it is in.
• Easy to install.
• Easy to Maintain.
• For systems that burn pellets, powder fuel, wood chips, etc. for different fuel types, please contact
us!

TANK CAPACITY

BOILER FLANGES FUEL

DIMENSIONS ø

APPROXIMATE
CONDENSATE

RECOM. MIN.
PROPERTIES
TANK

INSULATION

CHIMNEY
PRESSURE
VOLUME

WEIGHT
COUNTER-

CAPACITY
WATER

BLOWDOWN
BLOWDOWN

SMOKE
OUTPUT

MIN.
SAFETY

SURFACE
STEAM

TUBE
BOTTOM

MODEL CAPACITY
WATER

Dimensions
INLET

POMANCE
OLIVE
COAL

BİRİM M² KCAL/H KW MW KG/H A B B1 B2 C H H1 K L L1 LT DN DN DN DN DN KG KG LT MBAR øMM MM øMM KG


THUNDERBOLT 10A 10 96.000 112 0,11 160 2150 980 900 950 600 1920 520 225 1550 150 570 32 25/40 32 40 32 150 125 160 3,5 76,1 100 225 1130

THUNDERBOLT 15A 15 144.000 167 0,17 240 2150 1000 900 950 600 1970 520 250 1730 150 960 40 25/40 32 40 32 150 125 240 4 76,1 100 250 1675

THUNDERBOLT 20A 20 192.000 223 0,22 320 2520 1000 900 950 650 2150 520 300 1950 150 1220 50 25/40 32 40 32 200 175 320 4,5 76,1 100 300 2025

THUNDERBOLT 25A 25 240.000 279 0,28 400 2760 1230 1100 950 650 2190 520 350 2050 200 1440 50 25/40 32 40 32 200 175 400 6 76,1 100 350 2820

THUNDERBOLT 30A 30 288.000 335 0,33 480 2950 1260 1100 950 650 2400 520 350 2230 200 1752 65 25/40 32 40 32 200 175 480 6 76,1 100 350 2950

THUNDERBOLT 35A 35 336.000 391 0,39 560 3110 1500 1100 950 650 2735 520 400 2370 200 1940 65 25/40 32 40 32 200 175 560 6 76,1 100 400 3110

THUNDERBOLT 40A 40 384.000 447 0,45 640 3360 1500 1100 950 700 2780 520 450 2620 200 2300 65 25/40 32 40 32 200 175 640 6,7 76,1 100 450 3470

THUNDERBOLT 45A 45 432.000 502 0,50 720 3360 1550 1100 950 700 2800 520 450 2620 200 2750 65 25/40 32 40 32 200 175 720 8 76,1 100 450 3830

THUNDERBOLT 50A 50 480.000 558 0,56 800 3360 1550 1100 950 700 2900 520 450 2620 250 3300 65 25/40 32 40 32 200 175 800 8 76,1 100 450 4020

THUNDERBOLT 60A 60 576.000 670 0,67 960 3650 1650 1100 950 700 3250 520 500 2900 250 3960 80 25/40 32 40 32 200 175 960 8,5 76,1 100 500 4824

THUNDERBOLT 70A** 70 672.000 781 0,78 1120 3800 1850 1100 950 700 3300 520 550 3000 250 4620 80 32/50 32 40 32 400 350 1120 9 76,1 100 550 5628

THUNDERBOLT 80A** 80 768.000 893 0,89 1280 3950 1900 1100 950 850 3450 520 550 3150 250 5280 100 32/50 32 40 32 400 350 1280 9 76,1 100 550 6432

THUNDERBOLT 90A** 90 864.000 1005 1,00 1440 4150 2000 1100 950 850 3720 520 600 3300 300 5940 100 32/50 32 40 32 400 350 1440 10,5 76,1 100 600 7236

THUNDERBOLT 100A** 100 960.000 1116 1,12 1600 4250 2150 1100 950 850 3800 550 600 3500 300 6600 100 32/50 32 40 32 400 350 1600 11 76,1 100 600 8040

THUNDERBOLT 125A** 125 1.200.000 1395 1,40 2000 4700 2150 1100 950 850 3900 550 650 3900 300 8250 125 40/65 32 40 32 400 350 2000 11 76,1 100 650 10050

THUNDERBOLT 150A** 150 1.440.000 1674 1,67 2400 5000 2250 1100 950 850 4150 550 700 4200 300 9900 125 40/65 32 40 32 400 350 2400 12 76,1 100 700 12060

THUNDERBOLT 175A** 175 1.680.000 1953 1,95 2800 5500 2250 1100 950 900 4250 550 750 4700 300 11550 125 50/80 32 40 32 400 350 2800 12,5 76,1 100 750 14070

THUNDERBOLT 200A** 200 1.920.000 2233 2,23 3200 5850 2350 1100 950 900 4400 550 800 5000 300 13200 150 50/80 32 40 32 400 350 3200 12,5 76,1 100 800 16080

EKOTEK HEAT TECHNOLOGIES HAS THE RIGHT TO MAKE CHANGES IN DIMENSIONS, WEIGHTS AND MODELS
WITHOUT NOTICE ACCORDING TO THE CHANGE IN STANDARDS, DESIGN, ETC.

NOTE: The recommended chimney diameter is calculated as an average of 400 m altitude. The diameter of the chimney is the minimum size and may vary.

THE DATA IN THE TABLE IS MADE BASED ON 8 BAR PRESSURE. DATA MAY VARY DEPENDING ON PRESSURE.

Contact : +90 256 231 15 95 23


HYBRID SERIES
1.000 kg/h - 25.000 kg/h steam production capacity
Working pressure between 3 – 25 bar

• Lignite coal, olive pomace, pellets, sawdust, SUNFLOWER SHELLS, HAZELNUT SHELLS, etc. HYBRID
BOILER is formed by combining granular Water tube and Flame smoke tube boiler types in the
same body.
•Water-tube primary furnace mounted on a rotary grate or stoker is manufactured at the required
height as a result of detailed and precise calculations, and a large volume combustion chamber is
formed on the rotary grate. Scotch type boiler with Flame Smoke tube and radiation heat boiler are
connected to each other by water collector pipes.
• Large-volume combustion chamber is required to maximize flame length, flame radiation, gas and
heat generated as a result of combustion in solid fuels.
• Second (secondary) module Flame smoke tube boiler has two passages and is designed to achieve
maximum efficiency for the required capacity. The smoke volume, which decreases as the
temperature decreases, is designed to pass through the boiler at the most appropriate speeds. By
keeping the passageways of the flame long in the boiler, a large part of the heat energy resulting
from the combustion remains in the boiler and steam
has been used in production.
• Thanks to its larger steam volume, the system can instantly respond to peak steam drafts, and flash
steam production is provided thanks to the water-tube primary furnace.
• Changing the pipes of the fire smoke tube boiler; The front and back covers can be opened and
changes can be made very easily.
• Since the Hybrid Steam boiler fully reflects all the calories of the burning fuel to the steam
production process, it is possible to obtain the maximum fuel value and convert it to steam.
• You can use our Hybrid Steam Boiler with a variable efficiency of approximately 82% depending on
the fuel type.
• Blowdown and flanged cleaning are available in the lower collectors.
• While calculating the boiler heat load, the optimum heat load is given to the boiler heating surface
area.
• Since the extra heating surface is completed with a water and flame pipe system, the solid fuel
burning efficiency is much higher in 3-Pass Scotch Type Boilers compared to solid fuel burning.
• Thanks to its large water and steam volume, it provides high performance in intense and
continuous working conditions and sudden steam withdrawals.
• The water and flame tube system provides the opportunity to obtain drier and higher energy steam
with its surface area.
• If requested, automatic ash discharge, automatic lignite loading and transfer system can be added
to our solid fuel boilers.

% 100 SAFE ,
Min 698 kW - Max 17442 kW
USER-FRIENDLY

24 www.ekotekkazan.com
SOLID FUEL HIGH PRESSURE
STEAM BOILER
• Our products do not cause noise pollution with their silent operation.
• Air sent to the primary with the help of a fan; It provides a controlled and clean smokeless
combustion.
• It is much more efficient and long lasting by meeting other boiler designs and also Ekotek Quality.
• According to the pressure values. It has been produced in accordance with 12952-3, 12953-2
Standard and 2014/68/EU Pressure Vessels directive and has CE certificate.
• Smoke pipes are welded with mirrors and provide safer and long-lasting operation.
• Heat loss is reduced thanks to strong insulation with glass wool or rock wool.
• With its stylish appearance, it is noticed with its compatibility in the environment it is in.
• Easy to install.
• Easy to Maintain.
• Upon request, our steam boilers can be delivered as a package with all accessories.
• For systems that burn pellets, powder fuel, wood chips, etc. for different fuel types, please contact
us!

TANK CAPACITY

BOILER FLANGES FUEL


DIMENSIONS ø

APPROXIMATE
CONDENSATE

RECOM. MIN.
PROPERTIES

TANK
INSULATION

CHIMNEY
VOLUME

WEIGHT
CAPACITY
WATER

SMOKE
BLOWDOWN
BLOWDOWN
OUTPUT

MIN.
SAFETY

TUBE
SURFACE
STEAM

WATER

BOTTOM

MODEL CAPACITY Dimensions


INLET

POMANCE
OLIVE
COAL

BİRİM M² KCAL/H KW MW KG/H A B B1 B2 D D1 H H1 K L LT DN DN DN DN DN KG KG LT øMM MM øMM KG


HİBRİT 50* 50 600.000 698 0,70 1000 4270 1650 850 1100 1370 500 3300 520 500 3600 3180 80 25/40 32 40 32 150 125 1000 76,1 150 500 7600
HİBRİT 60* 60 720.000 837 0,84 1200 4350 1770 850 1100 1450 500 3450 520 550 3700 3970 100 32/50 32 40 32 150 125 1500 76,1 150 550 8250

HİBRİT 80* 80 960.000 1116 1,12 1600 4500 1850 850 1100 1580 500 3580 520 550 3850 4530 100 32/50 32 40 32 150 125 2000 76,1 150 600 9750
HİBRİT 100* 100 1.200.000 1395 1,40 2000 4550 1850 850 1100 1580 550 3750 520 600 4200 5250 100 40/65 32 40 32 150 125 2000 76,1 150 600 12350

HİBRİD 125* 125 1.500.000 1744 1,74 2500 4750 2000 850 1100 1670 550 3850 520 700 4320 5870 125 50/80 32 40 32 150 125 2500 76,1 150 700 14200

HİBRİT 150* 150 1.800.000 2093 2,09 3000 4900 2100 850 1100 1750 550 3950 520 700 4450 6513 125 50/80 32 40 32 200 175 3000 76,1 150 700 17560

HİBRİT 200* 200 2.400.000 2791 2,79 4000 5150 2350 850 1100 2000 600 4000 520 800 4650 7350 150 50/80 32 40 32 200 175 4000 76,1 150 800 19100
HİBRİT 250* 250 3.000.000 3488 3,49 5000 5400 2550 850 1100 2200 600 4100 550 900 4800 8920 200 65/100 32 40 32 200 175 5000 76,1 150 900 21750

HİBRİT 300** 300 3.600.000 4186 4,19 6000 5600 2650 1000 1100 2300 600 4250 550 1000 5200 10750 200 65/100 32 40 32 200 175 6000 76,1 150 1000 24300

HİBRİT 350** 350 4.200.000 4884 4,88 7000 5650 2750 1000 1100 2400 650 4400 550 1100 5500 11300 200 80/125 32 40 32 200 175 7000 76,1 150 1100 26750
HİBRİT 400** 400 4.800.000 5581 5,58 8000 5750 2850 1000 1100 2500 650 4500 550 1100 5650 11950 200 80/125 32 40 32 200 175 8000 76,1 150 1100 29250

HİBRİT 500** 500 6.000.000 6977 6,98 10000 5900 3050 1000 1100 2700 650 4950 600 1200 5750 13500 250 80/125 32 40 32 200 175 10000 76,1 150 1200 31700

HİBRİT 600** 600 7.200.000 8372 8,37 12000 6400 3300 1000 1100 2950 650 5350 600 1300 5900 15870 250 100/150 32 40 32 200 175 12000 76,1 150 1300 34600

HİBRİT 750** 750 9.000.000 10465 10,47 15000 6750 3450 1000 1100 3100 700 5900 600 1500 6000 17600 300 100/150 32 40 32 200 175 15000 76,1 150 1500 37300
HİBRİT 900** 900 10.800.000 12558 12,56 18000 6950 3600 1000 1100 3250 700 6100 600 1700 6000 18400 300 100/150 32 40 32 400 350 18000 76,1 150 1700 38500

HİBRİT 1000** 1000 12.000.000 13953 13,95 20000 7100 3850 1000 1100 3500 700 6450 600 1800 6000 21600 300 100/150 32 40 32 400 350 20000 76,1 150 1800 41370
HİBRİT 1250** 1250 15.000.000 17442 17,44 25000 7500 4150 1000 1100 3800 700 6700 600 2100 6000 23800 300 125/200 32 40 32 400 350 25000 76,1 150 2100 49520

EKOTEK HEAT TECHNOLOGIES HAS THE RIGHT TO MAKE CHANGES IN DIMENSIONS, WEIGHTS AND MODELS
WITHOUT NOTICE ACCORDING TO THE CHANGE IN STANDARDS, DESIGN, ETC.

NOTE: The recommended chimney diameter is calculated as an average of 400 m altitude. The diameter of the chimney is the minimum size and may vary.

THE DATA IN THE TABLE IS MADE BASED ON 8 BAR PRESSURE. DATA MAY VARY DEPENDING ON PRESSURE.

**DIMENSIONS MAY VARY DEPENDING ON THE PROJECT ON OUR ROTATING GRATE AND MOVING GRATE MODELS.

Contact : +90 256 231 15 95 25


VOLCANO SERIES
3.000 kg/h - 25.000 kg/h steam production capacity
Working pressure between 3 – 16 bar

• In our front furnace boilers, in order to provide sufficient heat transfer area for solid fuel
combustion, a traditional 3-Pass Scotch Type Smoke/Flame Tube Steam Boiler is designed by adding
a front furnace consisting of a water pipe bundle in front of it. Our boilers are designed for minimum
4.500 kcal/h (flame temperature 1200 C°) fuel. Please contact our company to burn lower calorie fuel.
• Blowdown and flanged cleaning are available in the lower collectors.
• While calculating the boiler heat load, the optimum heat load is given to the boiler heating surface
area.
• Thanks to the pre-furnace addition, the combustion chamber completely eliminates the problem of
not providing sufficient heat transfer surface in solid fuel applications compared to standard
gas/liquid fuel boilers.
• Since the need for extra heating surface and combustion chamber is eliminated by the front
furnace, solid fuel burning efficiency is much higher in 3-pass Scotch Type Boilers compared to solid
fuel burning.
• If requested, automatic ash discharge and automatic lignite loading system can be added to our
solid fuel boilers.
• Thanks to its large water and steam volume, it provides high performance in intense and
continuous working conditions and sudden steam withdrawals.
• Thanks to its high heating surface area, it provides the opportunity to obtain drier and higher
energy steam.
• We can manufacture movable Grate and rotating Grate Upon request,
• PLC control system can be added upon request.
• OUR COMPANY RECOMMENDS YOU TO USE AUTOMATIC BOTTOM BLOWdown AND SURFACE
BLOWdown IN THE SYSTEM. (PACKAGE MANUAL BLLOWERS ARE AVAILABLE IN THE SYSTEMS)
• Ekotek heat technologies designs different combustion systems specially for you. WE HAVE
MANUFACTURING WITH STOCKER-HELIX, ROTARY GRATE AND PISTON MOVING GRATE.
• Ekotek Heating Technologies 5 types of safety systems are used in all steam boilers. All safety
systems, including steam temperature, mechanical pressure, digital pressure, safety valve, chimney
temperature controls, as well as boiler feeding pumps, are used in double standard packages.
• PLC control system can be added upon request.
• If you want to be in control, you should definitely see our optional options. Control your power with
Ekotek technology. With optional options; Plc Touch screen controlled, Modbus RTU (Remote
Terminal Unit Rtu) completely under your control.

Min 2093 kW - Max 17442 kW % 100 SAFE ,


USER-FRIENDLY

26 www.ekotekkazan.com
SOLID FUEL, FRONT FURNACE,
HIGH PRESSURE STEAM BOILER
• Our products do not cause noise pollution with their silent operation.
• Air sent to the primary with the help of a fan; It provides a controlled and clean smokeless
combustion.
• It is produced as corrugated furnace and combustion chamber according to the pressure values.
The strength of the boiler and its resistance against thermal stresses have been increased in this way.
• Smoke pipes are welded with mirrors and provide safer and long-lasting operation.
• Heat loss is reduced thanks to strong insulation with glass wool or rock wool.
• With its stylish appearance, it is noticed with its compatibility in the environment it is in.
• Easy to install.
• Easy to Maintain.
• Upon request, our steam boilers can be delivered as a package with all accessories.
• For systems that burn pellets, powder fuel, wood chips, etc. for different fuel types, please contact
us!

TANK CAPACITY

DIMENSIONS ø
BOILER FLANGES FUEL

APPROXIMATE
CONDENSATE

RECOM. MIN.
PROPERTIES
INSULATION
TANK

CHIMNEY
VOLUME

WEIGHT
CAPACITY
WATER

BLOWDOWN
BLOWDOWN
OUTPUT

MIN.
SAFETY

SURFACE
STEAM

MODEL
BOTTOM

CAPACITY
WATER

Dimensions
INLET

POMANCE
OLIVE
COAL

BİRİM M² KCAL/H KW MW KG/H A B C D G H H1 H2 H3 L L1 L2 K LT DN DN DN DN DN KG KG LT MM øMM KG


VOLCANO 150A** 150 1.800.000 2093 2,09 3000 10950 1850 750 2100 4000 3900 2350 650 900 3760 5190 1250 750 12000 125 50/80 32 40 32 400 350 3000 150 750 15000

VOLCANO 175A** 175 2.100.000 2442 2,44 3500 11750 2150 800 2400 4300 4300 2750 650 900 4220 5480 1250 800 13250 150 50/80 32 40 32 400 350 3500 150 800 17500

VOLCANO 200A** 200 2.400.000 2791 2,79 4000 12500 2150 950 2400 4300 4650 2750 650 1250 4675 5375 1500 900 14000 150 50/80 32 40 32 400 350 4000 150 900 21000
VOLCANO 250A** 250 3.000.000 3488 3,49 5000 14000 2250 1000 2400 4300 4870 2900 720 1250 4675 6825 1500 1000 16500 200 65/100 32 40 32 400 350 5000 150 1000 24000

VOLCANO 300A** 300 3.600.000 4186 4,19 6000 14500 2450 1250 2700 4850 5070 2950 720 1400 5020 6230 2000 1100 17500 200 65/100 32 40 32 600 525 6000 150 1100 28000
VOLCANO 350A** 350 4.200.000 4884 4,88 7000 15250 2800 1250 3050 5200 5420 3250 720 1450 5250 6750 2000 1100 17500 200 80/125 32 40 32 600 525 6000 150 1100 28000

VOLCANO 400A** 400 4.800.000 5581 5,58 8000 16500 2850 1250 3100 5250 5670 3500 720 1450 5250 7500 2500 1200 19000 200 80/125 32 40 32 600 525 8000 150 1200 32000

VOLCANO 500A** 500 6.000.000 6977 6,98 10000 17500 3000 1750 3250 5400 6100 3650 800 1650 5600 7650 2500 1300 22000 250 80/125 32 40 32 600 525 10000 150 1300 36000

VOLCANO 600A** 600 7.200.000 8372 8,37 12000 23700 3050 2500 3300 5450 6200 3750 800 1650 5800 11900 3500 1500 25000 250 100/150 32 40 32 600 525 12000 150 1500 40000
VOLCANO 800A** 800 9.600.000 11163 11,16 16000 24750 3650 2750 3850 6100 6950 4350 800 1800 6300 12100 3500 1800 26500 300 100/150 32 40 32 800 700 16000 150 1800 43500

VOLCANO 1000A** 1000 12.000.000 13953 13,95 20000 25200 3800 2750 4000 6250 7100 4500 800 1800 6400 12450 3500 2100 28700 300 100/150 32 40 32 800 700 20000 150 2100 45700
VOLCANO 1250A** 1250 15.000.000 17442 17,44 25000 26750 4150 3000 4300 6550 7600 4850 800 1950 7900 12500 3500 2250 30000 300 125/200 32 40 32 800 700 25000 150 2250 48000
EKOTEK HEAT TECHNOLOGIES HAS THE RIGHT TO MAKE CHANGES IN DIMENSIONS, WEIGHTS AND MODELS
WITHOUT NOTICE ACCORDING TO THE CHANGE IN STANDARDS, DESIGN, ETC.

NOTE: The recommended chimney diameter is calculated as an average of 400 m altitude. The diameter of the chimney is the minimum size and may vary.

THE DATA IN THE TABLE IS MADE BASED ON 8 BAR PRESSURE. DATA MAY VARY DEPENDING ON PRESSURE.

**DIMENSIONS MAY VARY DEPENDING ON THE PROJECT ON OUR ROTATING GRATE AND MOVING GRATE MODELS.

Contact : +90 256 231 15 95 27


Mega Volt® SERIES
50kg/h-1500 kg/h steam production capacity
Working pressure between 1- 5 bar

• It works in 2-3-4-5-6 stages and fully automatic depending on the capacity. Produces as much
steam as you need
• Steam domed. In this way, it is not affected by sudden steam draws. Heater resistors are not
damaged in sudden needs
• It is possible to obtain purified steam from water thanks to a special separator combined with
steam.
• It has been designed according to all possible adverse conditions and is equipped with
extraordinary safety chains. In this way, there is no need for a separate element to operate.
• It is shipped with all its fixtures.
• Since the water volume is extremely low, it is possible to use it in places where people are
employed.
• Steam temperature and all functions can be followed on the PID screen from the control panel or
optionally on the plc screen.
• Heating Elements are made of stainless steel.
• The outer coating is electrostatic powder-coating powder oven painted.
• It is ready for operation when electricity, water, connection is made.
• It is a complete package unit with all its equipment and it is extremely easy to install and transport.

% 100 SAFE , USER-FRIENDLY

Min 112 kW - Max 3907 kW

28 www.ekotekkazan.com
ELECTRIC STEAM GENERATOR

• Ekotek Heating Technologies 5 types of safety systems are used in all steam boilers. Steam
temperature, mechanical pressure, digital pressure, safety valve controls, as well as boiler feed
pumps
All safety systems, including double standard packages, are used.
• PLC control system can be added upon request. You can contact us for detailed information.
• If you want to be in control, you should definitely see our optional options. Control your power with
Ekotek technology. With optional options; Plc Touch screen controlled, Modbus RTU (Remote
Terminal Unit Rtu) is completely under your control.

TANK CAPACITY

BOILER FLANGES
APPROXIMATE
CONDENSATE

PROPERTIES
INSULATION
VOLUME

WEIGHT
WATER

BLOWDOWN
BLOWDOWN
OUTPUT

MIN.
SAFETY

SURFACE
STEAM

BOTTOM

MODEL CAPACITY
WATER

Dimensions
INLET

BİRİM KW KCAL/H KG/H A B C D H H1 H2 LT DN DN DN DN DN M³ MM KG


MEGAVOLT 50 35 30.000 50 1000 950 850 550 1300 550 1850 420 15 15 15 25 15 50 100 550
MEGAVOLT 100 70 60.000 100 1050 1000 850 650 1500 550 2050 480 20 15 15 25 15 100 100 790
MEGAVOLT 150 105 90.000 150 1150 1100 950 650 1500 550 2050 527 25 15 25 25 25 150 100 850
MEGAVOLT 200 140 120.000 200 1150 1100 950 650 1550 550 2100 640 25 15 25 25 25 200 100 1000
MEGAVOLT 250 175 150.000 250 1250 1200 950 650 1750 550 2300 710 32 25 25 25 25 250 100 1300
MEGAVOLT 300 210 180.000 300 1300 1250 950 750 1750 550 2300 800 32 25 25 25 25 300 100 1400

MEGAVOLT 350 240 200.000 350 1400 1350 950 750 1750 550 2300 890 32 32 25 32 32 350 100 1480
MEGAVOLT 400 280 240.000 400 1500 1400 950 750 1750 550 2300 970 40 32 25 32 32 400 100 1550

MEGAVOLT 450 315 270.000 450 1550 1500 950 750 1750 550 2300 1050 40 40 25 32 32 450 100 1650
MEGAVOLT 500 350 300.000 500 1650 1600 1100 750 1750 550 2300 1160 50 40 32 32 32 500 100 1770
MEGAVOLT 600 420 360.000 600 1750 1650 1100 750 1750 550 2300 1320 50 40 32 32 32 600 100 1850
MEGAVOLT 700 490 420.000 700 1900 1800 1100 750 1950 550 2500 1460 50 50 32 32 32 700 100 2000
MEGAVOLT 800 560 480.000 800 2000 1900 1100 750 1950 550 2500 1570 50 50 32 32 32 800 100 2300
MEGAVOLT 900 630 540.000 900 2100 2000 1100 750 1950 550 2500 1750 65 50 32 32 32 900 100 2450
MEGAVOLT 1000 698 600.000 1000 2150 2050 1100 750 1950 550 2500 1920 65 50 32 32 40 1000 100 2600
MEGAVOLT 1250 872 750.000 1250 2200 2100 1100 750 2050 550 2600 2220 65 65 32 40 40 1250 100 2750
MEGAVOLT 1500 1045 900.000 1500 2300 2200 1100 750 2100 550 2650 2480 80 65 32 40 40 1500 100 2900

EKOTEK HEAT TECHNOLOGIES HAVE THE RIGHT TO MAKE CHANGES IN STANDARDS,


DESIGNS, VS, DIMENSIONS, WEIGHTS AND MODELS WITHOUT NOTICE.

Contact : +90 256 231 15 95 29


CONDENSATE TANK

GENERAL INFORMATION AND MATERIAL QUALITY


• Our company is controlled and audited by EKOTEK, Brand
registered and ISO 9001:2015 quality management system.
• Welding processes are carried out by certified welders in • Thermal shocks caused by cold condensate in the boiler are
accordance with approved WPS and WPQRs. prevented.
• The products used in production are all certified materials. • The condensate tank prevents the energy from being
• Our products are manufactured according to EN288, thrown into the atmosphere and provides heat recovery.
EN287-1 using P 265 GH and P 355 GH quality sheet metal.
• Our products are manufactured using boiler pipes made of % 100 SAFE , USER-FRIENDLY
P235GH and higher quality steel in accordance with TS EN
10217-2 norm. • It is manufactured in two different types as horizontal and
• Ideal Boiler feed water temperature should be 85 ºC. vertical.
• The steam, which is used as the heating fluid in the • Feed water heater coils in the tank or open steam
Condensate System, transfers the heat energy within its own It is heated by the inlet.
body to the boiler feed water with the energy transfer • Depending on the customer's request; The condensate tank
method during condensation. In this way, the temperature is insulated with a sheet over rock wool, preventing heat
of the boiler feed water is increased. losses from the system to the outside.
• When requested, temperature control automation in the • Since the feed water does not lose its energy in the
condensate tank can be provided with a thermostatic valve. condensate tank, the amount of energy to be given in the
boiler is reduced. Thus, it saves fuel.
• Depending on the customer's request, it is delivered as a
package (with all its fixtures).

TANK FLANGES C
OUTPUT

MODEL CAPACITY SHEET APPROXIMATE


WATER

WATER

Dimensions
INLET

THICKNESS DISCHARGE WEIGHT

BİRİM M³ A B C H L MM DN DN DN KG
EKO CONDENSATE 1 1 900 1000 350 1500 1550 4 32 40 40 150
EKO CONDENSATE 2 2 900 1000 350 1500 2550 4 32 40 40 230 B
EKO CONDENSATE 3 3 1150 1250 350 1750 2750 4 32 40 40 350
EKO CONDENSATE4 4 1300 1400 350 1900 2750 4 32 40 40 550

EKO CONDENSATE5 5 1500 1600 350 2100 2850 5 32 40 40 720

EKO CONDENSATE6 6 1500 1600 400 2100 3250 5 32 40 40 900

EKO CONDENSATE7 7 1500 1600 400 2100 3750 5 32 40 40 1050


EKO CONDENSATE8 8 1500 1600 400 2100 4250 5 32 40 40 1190
L
EKO CONDENSATE9 9 1500 1600 400 2100 4800 5 32 40 40 1300

EKO CONDENSATE10 10 1500 1600 500 2100 5350 5 32 40 40 1450


EKO CONDENSATE11 11 1650 1750 500 2250 4750 5 32 40 40 1570

EKO CONDENSATE12 12 1650 1750 500 2250 5250 5 32 40 40 1670

EKO CONDENSATE13 13 1650 1750 500 2250 5750 5 32 40 40 1750

EKO CONDENSATE14 1 1650 1750 600 2250 6100 5 32 40 40 1870


EKO CONDENSATE15 2 1650 1750 600 2250 6650 6 32 40 40 1950

EKO CONDENSATE16 3 1750 1850 600 2350 6250 6 32 40 40 2100


EKO CONDENSATE17 4 1750 1850 600 2350 6650 6 32 40 40 2240

EKO CONDENSATE18 5 1750 1850 600 2350 7000 6 32 40 40 2400

EKO CONDENSATE19 6 1900 2000 700 2500 6500 6 32 40 40 2570 H


EKO CONDENSATE20 7 1900 2000 700 2500 6750 6 32 40 40 2790
EKO CONDENSATE21 8 1900 2000 700 2500 7300 6 32 40 40 3000

EKO CONDENSATE22 9 1900 2000 700 2500 7600 6 32 40 40 3250


EKO CONDENSATE23 10 1900 2000 700 2500 8000 6 32 40 40 3400

EKO CONDENSATE24 11 1900 2000 700 2500 8250 6 32 40 40 3600

EKO CONDENSATE25 12 1900 2000 750 2500 8250 6 32 40 40 3750

EKO CONDENSATE30 13 2050 2250 750 2600 8250 6 32 40 40 4000

EKOTEK HEAT TECHNOLOGIES HAVE THE RIGHT TO MAKE CHANGES IN STANDARDS, A


DESIGNS, VS, DIMENSIONS, WEIGHTS AND MODELS WITHOUT NOTICE.

30 www.ekotekkazan.com
DEGASSER TANK

GENERAL INFORMATION AND MATERIAL QUALITY


GENERAL INFORMATION AND MATERIAL QUALITY
• Our company is controlled and audited by EKOTEK, Brand • It is produced in the required thickness, in the diameter and
registered and ISO 9001:2015 quality management system. size suitable for the capacity.
• Welding processes are carried out by certified welders in • Degasser; It is manufactured from horizontal cylindrical,
accordance with approved WPS and WPQRs. convex head type P 265 GH or P 355 GH boiler sheet,
• The products used in production are all certified materials. depending on the type and boiler room location.
• Our products are manufactured in accordance with EN288, • It is covered with insulation material of appropriate density
EN287-1 by using P 265 GH and P 355 GH quality boiler sheet. and thickness.
• Degasser; It is made of 316L stainless steel.
• Degasser; It performs the degasing process at 102°C
temperature and 0.2 Bar pressure.
• Degasser; It is used to degas the free O² and CO² in the
Condensate Tank. In this way, it prevents punctures that may
occur in the body of the boiler in the size of lentils. B

% 100 SAFE , USER-FRIENDLY


• Optionally, it is coated with galvanized, aluminum or
stainless sheet. H
• There are dome connection flanges and necessary armature
connection flanges on the tank.
• There is a steam distribution collector and pipes for mixing
type heating at its base.
• Centrifugal or stepped type pumps are used to feed the
deaerator with water to the level and optionally.

A
APPROXIMATE
WEIGHT

MODEL CAPACITY Dimensions WATER


VOLUME

BİRİM M³ A B C D H L K LT KG
EKO DGT 1 1 1150 1250 500 950 2450 1850 250 500 420
EKO DGT 2 2 1450 1450 500 1250 2950 2400 250 1000 530
L
EKO DGT 3 3 1450 1450 550 1250 2950 2400 300 1500 530 C
EKO DGT 4 4 1500 1450 550 1300 3000 2400 300 2000 700
EKO DGT 5 5 1600 1750 600 1400 3500 2950 300 2500 890
EKO DGT 6 6 1600 1750 600 1400 3500 3100 300 3000 950
EKO DGT 7 7 1900 1800 750 1700 3700 2950 500 3500 1100
EKO DGT 8 8 1900 1800 750 1700 3700 3100 500 4000 1320
EKO DGT 9 9 1950 1800 750 1750 3750 3100 500 4500 1400
EKO DGT 10 10 2000 2100 900 1800 4100 3200 500 5000 1650
EKO DGT 15 15 2000 2100 900 1800 4150 3950 500 7500 1975
EKO DGT 20 20 2000 2100 1000 1800 4200 5700 500 10000 2260
D
EKO DGT 25 25 2150 2200 1000 1950 4350 7300 600 12500 2900
EKO DGT 30 30 2150 2450 1000 1950 4750 8750 600 15000 3750
EKO DGT 40 40 2400 2750 1100 2200 5200 7400 600 20000 5200
EKO DGT 50 50 2400 2750 1100 2200 5200 8750 600 25000 6750
EKO DGT 60 60 2650 2750 1100 2450 5200 9250 600 30000 8100

EKOTEK HEAT TECHNOLOGIES HAVE THE RIGHT TO


MAKE CHANGES IN STANDARDS, DESIGNS, VS, DIMENSIONS,
WEIGHTS AND MODELS WITHOUT NOTICE.

Contact : +90 256 231 15 95 31


ACCUMULATION TANK

GENERAL INFORMATION
Some businesses (EPS, Glass, Cardboard) require peak steam Operation and Safety Equipment
loads that are three to four times the average loads. This • Accumulation tank body
peak load requirement takes a few minutes. • Steam inlet valve
To meet these intense loads, the large steam boiler • Air vent valve
Selecting a high capacity means both the initial investment • Steam inlet check-valve
cost and more energy costs than normal loads for most • Steam outlet valve
businesses. Boilers can change the steam demand • Steam outlet check-valve
fluctuations to some degree. can afford. Energy, hot water at • By-pass valve
saturated temperature stored in boilers. The steam demand • Control valve inlet and outlet valves
of the process suddenly increases, the pressure in the boiler • Control valve inlet strainer
decreases. Steam accumulation tank meets the high steam • Water inlet valve
demand. • Lower Blowdown valve
• Water level indicator and blowdown valve
Steam Accumulation Tank Design • Steam trap
Steam accumulation tank, horizontal or vertical at desired • Manometer
pressure • Safety valve
They are produced as cylindrical, cambered and insulated.
They are shipped with operating and safety equipment.

% 100 SAFE , USER-FRIENDLY


Benefits of Vapor Accumulation Tank
• Ensuring vapor balance against peak loads
• Optimum selection of steam boiler capacity
• Reduction of water supply to the steam boiler
• Less frequent activation of the steam boiler
• Reducing fuel consumption

H
APPROXIMATE
WEIGHT

MODEL CAPACITY Dimensions

BİRİM M³ A B C H L KG
EKO ACCU 100 0,1 450 700 250 750 1250 67

EKO ACCU 150 0,15 490 750 250 790 1300 72 B


EKO ACCU 200 0,2 510 775 250 820 1300 90
EKO ACCU 300 0,3 550 800 250 900 1750 100

EKO ACCU 400 0,4 575 825 250 935 1850 150
L
EKO ACCU 500 0,5 650 900 300 1000 1950 165
C
EKO ACCU 600 0,6 700 950 300 1100 2050 180

EKO ACCU 750 0,75 750 1000 300 1100 2150 245

EKO ACCU 1000 1 750 1000 300 1100 2400 300


EKO ACCU 1500 1,5 900 1150 300 1325 2650 375
A
EKO ACCU 2000 2 1000 1250 300 1400 2650 480
EKO ACCU 3000 3 1100 1350 400 1500 3150 690

EKO ACCU 4000 4 1200 1450 400 1600 3550 1070

EKO ACCU 5000 5 1250 1500 400 1650 4000 1210

EKOTEK HEAT TECHNOLOGIES HAVE THE RIGHT TO


MAKE CHANGES IN STANDARDS, DESIGNS, VS, DIMENSIONS,
WEIGHTS AND MODELS WITHOUT NOTICE.

32 www.ekotekkazan.com
33
Digital
Transformation
Vision
Deep-rooted experience requires being open to tomorrow's
technologies. Ekotek heating technologies, which closely
follow the innovations, are rapidly completing the "Digital
Transformation Project". In digital transformation, it instantly
monitors pressure, temperature, operating time, etc., and
creates reports in steam boilers and Thermal Oil heaters (hot
oil boilers) equipped with special sensors. Especially such
data will be of critical importance for the continuity of your
production processes in the near future.
Thanks to the data obtained, the operating conditions of all
types of equipment belonging to Ekotek heating
technologies can be monitored and, thanks to real-time data
analysis, smart and preventive maintenance can be planned
by the system. Thus, our customers are critical in their
production processes.
It can ensure production continuity without sudden and
undesirable interruptions, which is of great importance. The
digital transformation process carried out at Ekotek Heating
Technologies does not only cover the subjects in the field of
technology. Technology and created through it
We know that when data is used within purposeful
dynamics, it will bring an effective success. In our business
processes, we use all the technologies created by technology
to reach the maximum potential of our products and to meet
the needs of our customers more efficiently.
We take advantage of the opportunities. In this sense, we
anticipate that our digital transformation project will add
extensive training and skills to our company group. As Ekotek
Heating Technologies, we are working to include all our
business processes in the "Digital Transformation Project" in
order to understand the needs of the customers correctly
and to provide the right service as soon as possible. With its
25 years of experience, it has signed long-term collaborations
that accelerate its investments in the right technologies and
processes.
Ekotek heating technologies that beat and support
innovation and flexibility in every field; With this project, it
takes its exemplary business status one step further. It aims
to create a quality and permanent value for the most basic
and valuable resources of life such as clean environment,
economic, economical, environmentalist and permanent
efficiency.

34 www.ekotekkazan.com
Ekotek steam boiler and thermal oil heater (hot oil boilers)
You are 1-0 ahead in digital transformation with

Control your power with Ekotek technology. Ask for price for optional digital
conversion.
• In systems with PLC, you can program the way the machine works as you wish.
• You can get complete system fault information
• You can keep and export the system fault log.
• You can send a message about the system fault information, system variables
(temperature, pressure, level, etc.) to the phone numbers determined by the sms
module.
• You can send system fault information, system variables (temperature, pressure,
level, etc.) to the specified mail accounts.
• The system is simply communicated with the PLC and the computer.
You can be controlled from the computer. With Modbus RTU (Remote Terminal
Unit (Rtu), you are in complete control.
• You can quickly troubleshoot by connecting to the PLC system remotely via
internet.
• You can view all the variables in the system (temperature, pressure, level etc.) and
on the HMI screen and simply enter the set information.
• You can view instantaneous engine, valve, equipment operation and location
information on the HMI screen.
• You can easily monitor the system on the HMI screen and make it easier to
intervene in the system.
• You can make the system start and stop automatically in the daily working time
interval.
• All temperature, pressure, level data can be displayed graphically and you can
record hourly daily weekly data and export them whenever you want.

Contact : +90 256 231 15 95 35


Our company is controlled and audited by EKOTEK, Brand registered and ISO 9001:2015 quality
management system.

For each product, module b (project) + module f (manufacturing) is certified with CE certificate
according to TSE Standard.

Penetrant and radiographic tests are performed by the authorized company for our resources.
In our Hot Oil Boilers, serpentine pipe welds are argon welded and subjected to RADIOGRAPHIC
test after welding processes.

Welding processes are carried out by certified welders in accordance with approved WPS and
WPQRs. Welding processes are subjected to radiographic testing at the rates stipulated by the
standards.

The products used in production are all certified materials.


Our products are produced in accordance with TS EN 12952-3 Standard and 2014/68/EU Pressure
Vessels directive and have CE certificate.
Our products are manufactured according to EN288, EN287-1 by using P 265 GH and P 355 GH
quality boiler sheet.
Our products are manufactured using boiler pipes made of P235GH and higher quality steel in
accordance with TS EN 10217-2 norm.10

36 www.ekotekkazan.com
Hot oil boiler (Thermal Oil Heater)
It is an industrial heating equipment whose source requires a constant heat source and is used
where only heat transfers are desired instead of pressure. In this equipment, a thermal fluid is
circulated throughout the system for heat transfer to the desired processes. The combustion process
heats the thermal fluid, and this fluid carries and gives this heat to the desired fluid to conclude the
process. After transportation, this fluid comes back to the thermal fluid heater and this cycle
continues. They are heat transfer systems established to create pressure or use the heat obtained
from the cycle in the processing system. It is a type of heating system in which heat transfer oils with
boiling temperatures ranging from 260°C to 390°C are used in hot oil systems. It is used in many
industrial processes. Hot oil boilers are designed by Ekotek heating technologies according to solid,
liquid and gas fuel types.

• Buy heat transfer oil suitable for your operating degree.


• Chimney fan can be added to the system in solid fuel hot oil boilers. Get information from our
company.
Hot Oil Boilers are used in industries such as Metal and Mineral Processing, Construction Industry,
Petroleum and Chemical Industry, Paper and Cardboard Industry, Wood and Forest Products
Industry, Food and Beverage Industry, Textile Industry, Soap and Detergent Industry.
• The hot oil works as much as the pressure loss of the system.
• Ekotek Heating Technologies recommends all the accessories and systems that are known for
their safety in package system hot boilers.
• Ekotek Heating Technologies 5 types of safety systems are used in all hot oil boilers. All safety
systems, including oil temperature, mechanical pressure, digital pressure, combustion safety,
chimney temperature controls, as well as boiler oil circulation, are used in double standard
packages.
• PLC control system can be added upon request.
• If you want to be in control, you should see our optional options.
• Control your power with Ekotek technology. With optional options; Plc Touch screen controlled,
Modbus RTU (Remote Terminal Unit (Rtu)) is completely under your control Ekotek heat
technologies designs different combustion systems specially for you.
• WE HAVE MANUFACTURING WITH STOCKER - HELIX, ROTARY GRATE AND PISTON MOVING
GRATE.
• Ekotek Heating Technologies recommends all the accessories and burner systems used in
Package System Hot Oil Boilers (Thermal Oil Heaters) and burner systems from well-known brands.
Please inform our company about the gas pressure coming to the main gas line used by your
establishment. When choosing the burner, do not forget to connect a pe max: 300 Mbar gas line or
a Pe Max 21 Mbar Regulator to the burner according to the Main Gas pressure. natural gas provider
Please verify the information from your company.
• Do not forget to have a ce and tse certified chimney made for natural gas. Do not forget to get a
chimney offer suitable for natural gas from our company.
Contact : +90 256 231 15 95 37
PHOENIX SERIES
100,000 Kcal/h – 10.000.000 Kcal/h heat capacity

• Operates at high temperature and low pressure.


• The heat conduction oil used in the system does not cause calcification, calcification, sediment,
corrosive effect, etc. in the boiler. It can be used for a long time as it does not cause negative effects.
• There is no need to use any conditioning unit in heat conduction oil.
• Under normal conditions, freezing does not occur in the installation.
• The Hot Oil Boiler can also be used as a heating fluid in the production of Steam, Hot Water, Boiling
Water.
• Hot oil outlet temperature is controlled by PID controller.
• Hot oil return temperature is controlled by digital thermostats.
• Ekotek Heating Technologies recommends all the accessories and burner systems that are used in
Package System Hot Oil Boilers (Thermal Oil Heaters) from brands with known safety, Gas fuel type
Before making the package selection of industrial products, you should definitely notify our
company of the gas pressure coming to the main gas line used by your business. When choosing the
burner, do not forget to connect a pe max: 300 Mbar gas line or a Pe Max 21 Mbar Regulator to the
burner according to the Main Gas pressure. Please confirm the information from your natural gas
supplier company.
• PLC control system can be added upon request.
• If you want to be in control, you should definitely see our optional options. Control your power with
Ekotek technology. With optional options; Plc Touch screen controlled, Modbus RTU (Remote
Terminal Unit Rtu) is completely under your control.

% 100 SAFE , USER-FRIENDLY

Min 116 kW - Max 11628 kW

38 www.ekotekkazan.com
LIQUID/GAS FUEL THERMAL
OIL BOILERS

• Reliable due to low operating pressure.


• Operation and maintenance costs are low.
• Thermal conductivity coefficients of thermal oils are higher than other heating fluids. Due to the
high thermal conductivity coefficients, higher heat transfer is provided with less fuel energy.
• It saves fuel thanks to its modern design.
• Necessary security measures were taken by integrating the necessary control and automation
equipment into the system.
• Production starts under computer aided design control before each production.

RECOM. MIN.

APPROXIMATE
PROPERTIES
BOILER FLANGES

INSULATION
CHIMNEY

WEIGHT
DIMENSIONS ø

EXPANSION
VOLUME

OIL INLET
OUTPUT

MODEL CAPACITY Dimensions


OIL

OIL

LIQUID GAS
FUEL FUEL

BİRİM KCAL/H KW MW A B B1 D H H1 H2 K L LT DN DN DN MM øMM øMM KG


PHOENIX 100 100.000 116 0,12 1990 890 1050 1090 1550 300 300 180 800 32 40 40 25 100 180 180 375
PHOENIX 150 150.000 174 0,17 2200 890 1050 1090 1550 300 300 200 1000 40 40 40 25 100 225 200 430

PHOENIX 200 200.000 233 0,23 2440 930 1050 1130 1570 300 300 225 1150 65 50 50 25 100 250 225 495
PHOENIX 250 250.000 291 0,29 2600 960 1050 1160 1570 300 300 250 1240 85 50 50 25 100 300 250 590
PHOENIX 300 300.000 349 0,35 2800 960 1050 1160 1570 300 300 300 1400 97 65 65 25 100 300 300 885
PHOENIX 350 350.000 407 0,41 2900 1050 1050 1250 1650 300 300 300 1450 125 65 65 25 100 350 300 1230

PHOENIX 400 400.000 465 0,47 3100 1050 1050 1250 1650 300 300 350 1720 160 65 65 25 100 350 350 1850

PHOENIX 500 500.000 581 0,58 3100 1390 1150 1590 1990 300 300 350 1720 185 80 80 25 100 400 350 2100
PHOENIX 550 550.000 640 0,64 3200 1425 1150 1625 2000 300 300 400 1750 267 80 80 25 100 400 400 2270

PHOENIX 600 600.000 698 0,70 3350 1500 1150 1700 2100 300 300 400 2000 292 80 80 25 100 400 400 2450

PHOENIX 700 700.000 814 0,81 3600 1500 1150 1700 2100 300 300 450 2250 330 80 80 25 100 450 450 2790
PHOENIX 800 800.000 930 0,93 3850 1500 1200 1700 2100 300 300 450 2500 375 100 100 25 100 450 450 3200

PHOENIX 1000 1.000.000 1163 1,16 3850 1690 1200 1890 2300 300 300 500 2500 527 100 100 25 100 500 500 3460
PHOENIX 1250 1.250.000 1453 1,45 4180 1900 1200 2100 2550 350 350 550 2850 725 125 125 25 100 550 550 3950

PHOENIX 1500 1.500.000 1744 1,74 4500 2050 1200 2250 2700 350 350 550 3150 1060 125 125 25 100 600 550 4100
PHOENIX 2000 2.000.000 2326 2,33 5150 2210 1200 2410 2960 350 350 650 3700 1360 150 150 25 100 700 650 4450

PHOENIX 2500 2.500.000 2907 2,91 5600 2300 1300 2500 3100 350 350 700 4100 1520 150 150 25 100 750 700 5100

PHOENIX 3000 3.000.000 3488 3,49 6310 2530 1300 2730 3200 350 350 750 4850 1770 200 200 25 100 800 750 5750
PHOENIX 3500 3.500.000 4070 4,07 6600 2650 1300 2850 3400 350 350 850 5000 1890 200 200 25 100 850 800 6000

PHOENIX 4000 4.000.000 4651 4,65 6815 2800 1300 3000 3550 400 400 850 5350 2050 200 200 25 100 1000 850 6250

PHOENIX 5000 5.000.000 5814 5,81 7675 2930 1400 3130 3700 400 400 1000 6200 2350 200 200 25 100 1100 1000 6810
PHOENIX 6000 6.000.000 6977 6,98 8150 3150 1400 3350 3950 400 400 1100 6700 2650 200 200 25 100 1200 1100 7370

PHOENIX 7000 7.000.000 8140 8,14 8300 3250 1400 3450 4050 400 400 1100 6850 2960 250 250 25 100 1200 1100 8150

PHOENIX 8000 8.000.000 9302 9,30 8350 3400 1400 3600 4100 400 400 1200 6900 3150 250 250 25 100 1300 1200 9050
PHOENIX 9000 9.000.000 10465 10,47 8500 3600 1400 3800 4250 400 400 1200 7050 3450 250 250 25 100 1300 1200 10200

PHOENIX 10000 10.000.000 11628 11,63 8750 3600 1400 3800 4250 400 400 1200 7200 3800 300 300 25 100 1300 1200 12700

EKOTEK HEAT TECHNOLOGIES HAVE THE RIGHT TO MAKE CHANGES IN STANDARDS,


DESIGNS, VS, DIMENSIONS, WEIGHTS AND MODELS WITHOUT NOTICE.

NOTE: The recommended chimney diameter is calculated as an average of 400 m altitude.


The diameter of the chimney is the minimum size and may vary.

THE SYSTEM WORKS AS MUCH AS PRESSURE LOSSES, SO THE DATA IN THE TABLE VARY DEPENDING ON PRODUCTION AND INSTALLATION.

Contact : +90 256 231 15 95 39


DRAGON SERIES
80.000 Kcal/h- 10.000.000 Kcal/h heat capacity

• It works at high temperature and low pressure.


• Package system and assembly can be done in our hot oil boilers. Please contact our company.
• The heat transfer oil used in the system will not cause calcification, calcification, etc. in the boiler. It
can be used for a long time as it does not cause negative effects.
• There is no need to use any conditioning unit in heat conduction oil.
• Under normal conditions, freezing does not occur in the installation.
• The Hot Oil Boiler can also be used as a heating fluid in the production of Steam, Hot Water, Boiling
Water.
• Hot oil outlet temperature is controlled by PID controller.
• Hot oil return temperature is controlled by digital thermostats.
• Ekotek Heating Technologies recommends all the accessories and systems that are known for their
safety in the package system hot boilers.
• Ekotek Heating Technologies 5 types of safety systems are used in all hot oil boilers. All safety
systems, including oil temperature, mechanical pressure, digital pressure, combustion safety,
chimney temperature controls, as well as boiler oil circulation, are used in double standard packages.
• PLC control system can be added upon request.
• If you want to be in control, you should definitely see our optional options. Control your power with
Ekotek technology. With optional options; Plc Touch screen controlled, Modbus RTU (Remote
Terminal Unit Rtu) completely under your control
• Ekotek heat technologies designs different combustion systems specially for you. WE HAVE
STOCKER - SPIRAL HELIX , ROTARY GRATE AND PISTON MOVING GRATE MANUFACTURING.
• Our boilers are designed for minimum 4.500 kcal/h (flame temperature 1200 C°) fuel. Please contact
our company to burn lower calorie fuel.

% 100 SAFE , USER-FRIENDLY

Min 93 kW - Max 11628 kW

40 www.ekotekkazan.com
SOLID FUEL 3 PASS HOT OIL
BOILERS- THERMAL OIL HEATER
• Thanks to the thermal oil used instead of water in the installation, it does not leave any residue and
has no corrosive effect.
• Operation and maintenance costs are low.
• Its thermal conductivity coefficients are higher than other fluids.
• Due to the high thermal conductivity coefficients, higher heat transfer is achieved with less fuel
energy.
• Necessary safety measures have been taken by integrating the necessary control and automation
equipment in the system.
• It saves fuel thanks to its modern design.
• Before each production, production starts under the control of computer-aided design.
• For systems that burn pellets, powder fuel, wood chips, etc. for different fuel types, please contact
us!

APPROXIMATE
DIMENSIONS ø
BOILER FLANGES FUEL TANK

RECOM. MIN.
PROPERTIES
INSULATION

CHIMNEY
CAPACITY

WEIGHT
EXPANSION
VOLUME

OIL INLET
OUTPUT
OIL

MODEL CAPACITY Dimensions


POMANCE
OIL

OLIVE
COAL

BİRİM KCAL/H KW MW A B C D H H1 K L LT DN DN DN KG KG MM øMM KG


DRAGON 80A 80.000 93 0,09 1000 850 1050 750 1750 650 200 800 68 40 40 25 150 125 100 200 500
DRAGON 100A 100.000 116 0,12 1060 920 1120 750 1750 650 225 860 75 40 40 25 150 125 100 225 590
DRAGON 150A 150.000 174 0,17 1110 1000 1200 750 1750 650 250 910 100 40 40 25 150 125 100 250 885
DRAGON 200A 200.000 233 0,23 1385 1050 1250 900 2050 650 300 1185 140 50 50 25 200 175 100 300 1230
DRAGON 250A 250.000 291 0,29 1460 1300 1500 900 2175 700 350 1260 350 50 50 25 200 175 100 350 1850
DRAGON 300A 300.000 349 0,35 1790 1500 1700 900 2500 700 350 1590 430 65 65 25 200 175 100 350 2100
DRAGON 350A 350.000 407 0,41 1910 1500 1700 900 2640 750 400 1610 580 65 65 25 200 175 100 400 2450
DRAGON 400A 400.000 465 0,47 2210 1500 1700 900 2940 750 450 1910 630 65 65 25 200 175 100 450 2790
DRAGON 500A 500.000 581 0,58 2210 2050 2250 900 2940 750 450 1910 675 80 80 25 200 175 100 450 3200
DRAGON 600A 600.000 698 0,70 2250 2150 2350 900 3050 800 500 1950 750 80 80 25 200 175 100 500 3460
DRAGON 700A** 700.000 814 0,81 2600 2150 2350 900 3400 800 550 2300 875 80 80 25 400 350 100 550 3950
DRAGON 800A** 800.000 930 0,93 2800 2300 2400 900 3600 800 550 2500 950 100 100 25 400 350 100 550 4100
DRAGON 1000A** 1.000.000 1163 1,16 3050 2390 2590 900 3870 850 600 2750 1250 100 100 25 400 350 100 600 4450
DRAGON 1250A** 1.250.000 1453 1,45 3650 2390 2590 900 4350 850 650 3350 1650 125 125 25 400 350 100 650 5100
DRAGON 1500A** 1.500.000 1744 1,74 3850 2550 3090 900 4530 850 700 3550 2000 125 125 25 400 350 100 700 5750
DRAGON 2000A** 2.000.000 2326 2,33 4250 3000 3200 900 4950 850 800 3950 2200 150 150 25 600 525 100 800 6250
DRAGON 2500A** 2.500.000 2907 2,91 4415 3400 3600 900 5000 850 900 4015 2750 150 150 25 600 525 100 900 6810
DRAGON 3000A*** 3.000.000 3488 3,49 4650 3600 3800 900 5350 850 1000 4300 2900 200 200 25 600 525 100 1000 7370
DRAGON 4000A*** 4.000.000 4651 4,65 4915 3600 3800 900 6315 1400 1100 4600 3250 200 200 25 800 700 100 1100 8400
DRAGON 5000A*** 5.000.000 5814 5,81 5750 3700 3950 900 7350 1600 1200 5350 4658 200 200 25 800 700 100 1200 9350
DRAGON 6000A*** 6.000.000 6977 6,98 6100 3700 3950 900 7850 1750 1300 5700 5685 200 200 25 800 700 150 1300 11200
DRAGON 8000A*** 8.000.000 9302 9,30 7050 3800 4050 1000 8900 1850 1600 6600 6750 250 250 25 800 700 150 1600 13800
DRAGON 10000A*** 10.000.000 11628 11,63 7700 3900 4150 1000 9700 2000 1800 7200 7350 300 300 25 800 700 150 1800 16000

** IT CAN MANUFACTURED AS ROTATING GRATE OR MOVING PISTON GRATE


**DIMENSIONS MAY VARY DEPENDING ON THE PROJECT ON OUR ROTATING GRATE AND MOVING GRATE MODELS.
EKOTEK HEAT TECHNOLOGIES HAVE THE RIGHT TO MAKE CHANGES IN STANDARDS,
DESIGNS, VS,DIMENSIONS, WEIGHTS AND MODELS WITHOUT NOTICE.
NOTE: The recommended chimney diameter is calculated as an average of 400 m altitude.
The diameter of the chimney is the minimum size and may vary.
STOKER SECTION MAY VARY DEPENDING ON THE CAPACITY OF THE PRODUCT IN SOLID FUEL PRODUCTS.

THE SYSTEM WORKS AS MUCH AS PRESSURE LOSSES, SO THE DATA IN THE TABLE
VARY DEPENDING ON PRODUCTION AND INSTALLATION.

Contact : +90 256 231 15 95 41


ALBATROS SERIES
100,000 Kcal/h – 10.000.000 Kcal/h heat capacity

• Operates at high temperature and low pressure.


• The heat conduction oil used in the system does not cause calcification, calcification, residue,
corrosive effect, etc. in the boiler. It can be used for a long time as it does not cause negative effects.
• There is no need to use any conditioning unit in heat conduction oil.
• Under normal conditions, freezing does not occur in the installation.
• The Hot Oil Boiler can also be used as a heating fluid in the production of Steam, Hot Water, Boiling
Water.
• Hot oil outlet temperature is controlled by PID controller.
• Hot oil return temperature is controlled by digital thermostats.
• It has an ergonomic design that can be used in horizontal areas or vertical application areas to the
system.
• Ekotek heating technologies Albatros series, which is one of its original designs, is a marine type
thermal oil heater in areas where heat power is needed.
• Ekotek Heating Technologies recommends all the accessories and burner systems used in Package
System Hot Oil Boilers (Thermal Oil Heaters) and burner systems of known brands. When choosing
the burner, do not forget to connect a pe max: 300 Mbar gas line or a Pe Max 21 Mbar Regulator to
the burner according to the Main Gas pressure. Please confirm the information from your natural
gas supplier company.
• PLC control system can be added upon request.
• If you want to be in control, you should definitely see our optional options. Control your power with
Ekotek technology. With optional options; Plc Touch screen controlled, Modbus RTU (Remote
Terminal Unit Rtu) completely under your control

% 100 SAFE , USER-FRIENDLY

Min 116 kW - Max 11628 kW

42 www.ekotekkazan.com
LIQUID/GAS FUEL HOT OIL
BOILERS- THERMAL OIL HEATER
• Reliable thanks to its low working pressure.
• Operation and maintenance costs are low.
• Thermal conductivity coefficients of hot oils are higher than other heating fluids. Thanks to its high
thermal conductivity coefficients, higher heat transfer is achieved with less fuel energy.
• It saves fuel thanks to its modern design.
• Necessary security measures were taken by integrating the necessary control and automation
equipment into the system.
• Production starts under computer aided design control before each production.

RECOM. MIN.

APPROXIMATE
BOILER FLANGES

PROPERTIES
INSULATION
CHIMNEY

WEIGHT
DIMENSIONS ø
EXPANSION
VOLUME

OIL INLET
OUTPUT

MODEL CAPACITY
OIL

Dimensions
OIL

LIQUID GAS
FUEL FUEL

BİRİM KCAL/H KW MW A B C H H1 H2 K L LT DN DN DN MM øMM øMM KG


ALBATROS 100 100.000 116 0,12 2090 1090 990 1990 400 600 180 800 32 40 40 25 100 180 180 375
ALBATROS 150 150.000 174 0,17 2090 1090 1200 2200 400 600 200 1000 40 40 40 25 100 225 200 430
ALBATROS 200 200.000 233 0,23 2130 1130 1440 2440 400 600 225 1150 65 50 50 25 100 250 225 495
ALBATROS 250 250.000 291 0,29 2160 1160 1600 2600 400 600 250 1240 85 50 50 25 100 300 250 590
ALBATROS 300 300.000 349 0,35 2160 1160 1800 2800 400 600 300 1400 97 65 65 25 100 300 300 885
ALBATROS 350 350.000 407 0,41 2250 1250 1900 2900 400 600 300 1450 125 65 65 25 100 350 300 1230
ALBATROS 400 400.000 465 0,47 2250 1250 2100 3100 400 600 350 1720 160 65 65 25 100 350 350 1850
ALBATROS 500 500.000 581 0,58 2590 1590 2100 3100 400 600 350 1720 185 80 80 25 100 400 350 2100
ALBATROS 550 550.000 640 0,64 2625 1625 2200 3200 400 600 400 1750 267 80 80 25 100 400 400 2270
ALBATROS 600 600.000 698 0,70 2700 1700 2350 3350 400 600 400 2000 292 80 80 25 100 400 400 2450
ALBATROS 700 700.000 814 0,81 2700 1700 2600 3600 400 600 450 2250 330 80 80 25 100 450 450 2790
ALBATROS 800 800.000 930 0,93 2700 1700 2850 3850 400 600 450 2500 375 100 100 25 100 450 450 3200
ALBATROS 1000 1.000.000 1163 1,16 2890 1890 2850 3850 400 600 500 2500 527 100 100 25 100 500 500 3460
ALBATROS 1250 1.250.000 1453 1,45 3200 2100 3180 4180 400 600 550 2850 725 125 125 25 100 550 550 3950
ALBATROS 1500 1.500.000 1744 1,74 3350 2250 3500 4500 400 600 550 3150 1060 125 125 25 100 600 550 4100
ALBATROS 2000 2.000.000 2326 2,33 3510 2410 4150 5150 400 600 650 3700 1360 150 150 25 100 700 650 4450
ALBATROS 2500 2.500.000 2907 2,91 3600 2500 4600 5600 400 600 700 4100 1520 150 150 25 100 750 700 5100
ALBATROS 3000 3.000.000 3488 3,49 3830 2730 5310 6310 400 600 750 4850 1770 200 200 25 100 800 750 5750
ALBATROS 3500 3.500.000 4070 4,07 3950 2850 5600 6600 400 600 850 5000 1890 200 200 25 100 850 800 6000
ALBATROS 4000 4.000.000 4651 4,65 4100 3000 5815 6815 400 600 850 5350 2050 200 200 25 100 1000 850 6250
ALBATROS 5000 5.000.000 5814 5,81 4250 3150 6675 7675 400 600 1000 6200 2350 200 200 25 100 1100 1000 6810
ALBATROS 6000 6.000.000 6977 6,98 4400 3300 7150 8150 400 600 1100 6700 2650 200 200 25 100 1200 1100 7370
ALBATROS 7000 7.000.000 8140 8,14 4500 3400 7300 8300 400 600 1100 6850 2960 250 250 25 100 1200 1100 8150
ALBATROS 8000 8.000.000 9302 9,30 4700 3600 7350 8350 400 600 1200 6900 3150 250 250 25 100 1300 1200 9050
ALBATROS 9000 9.000.000 10465 10,47 4900 3800 7500 8500 400 600 1200 7050 3450 250 250 25 100 1300 1200 10200
ALBATROS 10000 10.000.000 11628 11,63 4900 3800 7750 8750 400 600 1200 7200 3800 300 300 25 100 1300 1200 12700

EKOTEK HEAT TECHNOLOGIES HAVE THE RIGHT TO MAKE CHANGES IN STANDARDS,


DESIGNS, VS, DIMENSIONS, WEIGHTS AND MODELS WITHOUT NOTICE.
NOTE: The recommended chimney diameter is calculated as an average of 400 m altitude.
The diameter of the chimney is the minimum size and may vary.

THE SYSTEM WORKS AS MUCH AS PRESSURE LOSSES, SO THE DATA IN THE TABLE VARY DEPENDING ON PRODUCTION AND INSTALLATION.

Contact : +90 256 231 15 95 43


STAINLESS CHIMNEY
SINGLE WALL STAINLESS STEEL CHIMNEY SYSTEMS
They are stainless steel chimney systems used in the
building shaft for solid, liquid and gaseous fuels. If
there is an application for the shaft, there is no need
to apply insulation to the flue remaining in the shaft.
The vertical load is carried on the wall stand or the
main carrier stand and the modules are connected
with flue clamps. Our chimneys are produced in high
quality with continuous TIG/WIG welding. It provides
easy and reliable mounting with bell plug and flue
clamp in negative pressure conditional systems. In
positive pressure systems, sealing is ensured with a
specially produced gasket inside the muff.

90° ELBOW
The friction in the chimneys is important.
manufactures two different types of elbows, fixed
knuckle and movable knuckle. Movable knuckle
elbow modules, one of the most important products
produced, are assembled using a universal system
and a special flange clamp system.
Each node of the elbows, for which special calculation
methods are used, can be narrowed or widened by
turning them during assembly, if desired. In this way,
since the gases coming out of the chimney do not
DOUBLE WALL STAINLESS STEEL CHIMNEY collide with the flange system outward after
SYSTEMS installation, the waste gas reaches the atmosphere
The Double Walled Stainless Steel Chimney System is with minimum friction - maximum speed.
used for outdoor and inside shaft/indoor applications After the clamps are tightened, the module becomes
where necessary. The inner wall is made of the stronger than the welded modules and gains
highest quality AISI 316 L stainless steel, and the strength.
material thickness of the wall is variable according to
the system specifications. 30mm or 50mm Rockwool
Insulation is applied between the main waste gas
modules and the outer wall, again according to the
system specifications. The outer wall can be made
with materials such as Galvanized - Aluminum - 430
Steel - 304 Stainless steel due to variables such as the Technicial Specifications:
system to be used, the application location, and the Material Used: 1.4301-1.4401 Stainless Steel (316 L)
environment. Chimney manufactures 23 different Dimensions: Ø 100~1200mm h: 500~1250mm
sizes between 100 mm diameter and 1200 mm Sheet Thickness: 0.40 ~ 3mm
diameter, all in its own facilities. Pressure Classes: N1 - P1
It forms the main body of the chimney, produced with Connection Type: Clamped - Gasketed - Muffled
superior cord press technology. Each module is Corrosion Class: Vm
mounted on the chimney by calculating the building Welding Type: Continuous TIG
height. MODEL
Again, each module has been designed by
increasing the strength with a special press
technology designed to carry the complete chimney
alone. Full
BİRİMwrapping is provided by opening the
special flange mouth. In assembly, special sealed
clamps are used between each module and its
by-products.

Technical Specifications
Material Used Angle: 1.4301-1.4401 Stainless Steel (316 L)-
15°-30°-45°-60°-75°-87°-90°
Dimensions: Ø 100~1200mm h: 500 ~600 mm
Sheet Thickness: 0.40 ~ 3mm
Pressure Classes: N1 - P1 - H2
Connection Type: Clamped - Gasketed - Muffled
Corrosion Class: Vm
Welding Type: Continuous: TIG

44 www.ekotekkazan.com
CYCLONE AND
MULTICYCLONE FILTER

GENERAL INFORMATION AND MATERIAL QUALITY • It is generally used to hold ash and soot formed as a result of
• Our company is controlled and audited by EKOTEK, Brand the combustion of solid fuels, especially lignite coal, in fuel
registered and ISO 9001:2015 quality management system. boilers.
• Welding processes are carried out by certified welders in • It is used in flue gas washing and filtering systems for the
accordance with approved WPS and WPQRs. purpose of keeping and separating the particles in the flue
• The products used in production are all certified materials. ash and soot containing flue gases.
• Our products are manufactured according to EN288, • Thanks to the cyclone filter design made according to the
EN287-1 using S 235 JR quality sheet metal. characteristic features of the dust particles to be separated,
• The dusty gas entering the cyclone tangentially at high the filter efficiency of the cyclones is maximized and an
speed from the cyclone inlet is given a helical flow form by effective filtering process is achieved.
means of the cyclone construction, allowing the particles • Cyclone filter design is made by considering various
with higher density than the carrier medium to be directed parameters such as the density of the dust particle to be
to the cyclone walls by centrifugal force. filtered and the particle size.
• Particles that lose their inertia due to the sudden speed
change in the cyclone flow through the cyclone wall and
% 100 SAFE , USER-FRIENDLY
flow into the lower conical collection bunker. As a result of • Classic cyclones are specially designed and manufactured
this mechanism, the gas, which has been purified from the for any capacity and any type of gas.
dust it contains, is given out from the upper part of the • In the cyclone filters, the solid phase dust particles that
cyclone through the outlet pipe in the center of the cyclone. come to the cyclone by being dragged in the air flow are
• It can be manufactured from S 235 JR quality material or Cr separated from the air by the effect of the centrifugal force
-Ni stainless material in various thicknesses depending on created in the cyclone filter and filtered. It has an average of
the abrasive feature of the dust particle. 80% dust retention compared to the particles that may come
out of the chimney, according to the fuel used, boiler
temperature, and the variations according to the ambient
conditions, compared to the chimneys without cyclone filter.
• Our cyclone filter productions can be optionally used in all
kinds of boilers.
B D

L A

H1
APPROXIMATE
WEIGHT

APPROXIMATE

MODEL CAPACITY Dimensions


WEIGHT

MODEL CAPACITY Dimensions

BİRİM ØMM A B C D H L
EKO CYCLONE 50 500 170 160 175 500 900 250 75
BİRİM ØMM A B C D H H1 L KG
EKO CYCLONE 62,5 625 200 170 175 625 1150 250 90
EKO MULTICYCLONE 1 500 500 1000 350 1000 1500 500 1000 130
EKO CYCLONE 72 720 200 220 200 720 1350 250 105
EKO MULTICYCLONE 2 750 750 1750 350 1250 2000 750 1250 285
EKO CYCLONE 84 840 250 280 200 840 1500 350 130
EKO MULTICYCLONE 3 1000 1000 2350 500 1500 2500 1000 1500 350
EKO CYCLONE 100 1000 300 325 250 1000 1600 350 160
EKO MULTICYCLONE 4 1250 1250 2750 500 1500 3000 1250 1750 575
EKO CYCLONE 115 1150 400 400 250 1150 1700 350 185
EKO MULTICYCLONE 5 1500 1500 3250 500 1750 3500 1500 2000 650
EKO CYCLONE 125 1250 500 500 300 1250 1850 400 200
EKO MULTICYCLONE 6 2000 2000 3500 600 2250 4000 2000 2000 750
EKO CYCLONE 150 1500 600 625 300 1500 1975 400 230
EKO MULTICYCLONE 7 2500 2500 3500 600 3000 4500 2250 2250 950
EKO CYCLONE 175 1750 750 750 500 1750 2400 500 375

EKO CYCLONE 200 2000 1000 1000 600 2000 2750 500 460
EKOTEK HEAT TECHNOLOGIES HAVE THE RIGHT TO MAKE
EKO CYCLONE 240 2400 1200 1200 750 2400 3250 500 610 CHANGES IN STANDARDS, DESIGNS, VS, DIMENSIONS, WEIGHTS
AND MODELS WITHOUT NOTICE.
EKOTEK HEAT TECHNOLOGIES HAVE THE RIGHT TO MAKE
CHANGES IN STANDARDS, DESIGNS, VS, DIMENSIONS, WEIGHTS
AND MODELS WITHOUT NOTICE. Contact : +90 256 231 15 95 45
WATER FILTER

GENERAL INFORMATION AND MATERIAL QUALITY


• Our company is controlled and audited by EKOTEK, Brand
registered and ISO 9001:2015 quality management system. It
complies with TSE standards.
• Welding processes are carried out by certified welders in
accordance with approved WPS and WPQRs.
• The products used in production are all certified materials.
• By using wet flue filters at the flue outlets of high-capacity
boilers. The particles in the air to be thrown out are washed
and further reduced.
• As the incoming flue gas passes through the expanding
flue filter chamber, it encounters the water spraying from
the nozzles.
• Pressurized water is sprayed on the flue gas, allowing the
particles to be washed.
• The nozzles pulverize the water and provide filtering as a • Since it regulates the carbon dioxide rate, it keeps the air
result of the encountering of harmful particles and 90% clean.
institutions carried in the smoke. • It keeps the environment clean as it keeps the ash, soot and
• As the water sprayed in the water system flue filter falls particles in the smoke.
down, it is polluted by holding particles and soot. • Water consumption is minimal.
Contaminated water accumulates in the chamber and is
discharged from the drain below. % 100 SAFE , USER-FRIENDLY
• In order for the water system chimney filters to work
efficiently and to provide the required values in the • It can be manufactured in all our boilers upon request.
measurements, they must be designed in certain • Before our production, necessary calculations and designs
proportions and widths, and spray a sufficient amount of are made and then the production is started.
water. • Easy to install and maintain.
• The watery chimney filters we manufacture are an
indispensable solution for a cleaner air release into the
atmosphere in apartments, restaurants, factories, residences,
and any area where solid fuels are used.
• 316L CHROME NICKEL Stainless material is used in our
water filter manufacturing.
APPROXIMATE
WEIGHT

MODEL CAPACITY Dimensions

BİRİM M³ A B C D H KG
EKO SDF 50 500 160 160 250 500 2250 310

EKO SDF 62,5 625 170 170 250 625 2350 475
EKO SDF 72 720 220 220 250 720 2600 540
EKO SDF 84 840 280 280 250 840 3000 730
EKO SDF 100 1000 325 325 250 1000 3300 870
EKO SDF 115 1150 400 400 250 1150 3950 950
EKO SDF 125 1250 600 600 300 1250 4350 1050
EKO SDF 150 1500 625 625 300 1500 5150 1260

EKO SDF 175 1750 750 750 300 1750 6050 1400
EKO SDF 200 2000 1000 1000 300 2000 6900 1675

EKO SDF 240 2400 1200 1200 500 2400 8250 2450
EKO SDF 300 3000 1500 1500 500 3000 10000 3200

EKOTEK HEAT TECHNOLOGIES HAVE THE RIGHT TO MAKE


CHANGES IN STANDARDS, DESIGNS, VS, DIMENSIONS, WEIGHTS
AND MODELS WITHOUT NOTICE.

46 www.ekotekkazan.comNOT: ÖNERİLEN BACA ÇAPI ORTALAMA 400 RAKIM OLARAK HESAPLANMIŞTIR.


BELİRTİLEN BACA ÇAPI ÖLÇÜLERİ MİNİMUM DEĞERLERDİR VE FARKLILIKGÖSTEREBİLİR.
ECO ECONOMIZER

GENERAL INFORMATION AND MATERIAL QUALITY


• Our company is controlled and audited by EKOTEK, Brand • It provides maximum energy saving with its high heat
registered and ISO 9001:2015 quality management system. transfer.
• Welding processes are carried out by certified welders in • Thanks to its flanged connection, it provides easy adaptation
accordance with approved WPS and WPQRs. to the mounting location.
• The products used in production are all certified materials. • It goes through quality control at every stage of production.
• Our products are manufactured according to EN288, • Our economizer models are designed to provide maximum
EN287-1 using S235JR quality sheet metal. heat transfer with finned pipes.
• Our products are manufactured using boiler pipes made of
P235GH and higher quality steel in accordance with TS EN % 100 SAFE , USER-FRIENDLY
10217-2 norm.
• To benefit from the energy of the flue gas by cooling it to a
• As Ekotek heat technologies, we offer important
temperature where it cannot corrode, and thus to provide
advantages to your business with our expert solutions in
maximum fuel savings by keeping the boiler thermal
energy saving.
efficiency at a high value; It is designed to make maximum
• Ekotek Heating Technologies has proven itself with its
use of heat conduction.
domestic and international sales, which has adopted the
• It adapts to its environment with its aesthetic appearance.
principle of working with quality and customer focus in the
• It provides ease of use with its dimensions suitable for your
heating sector with its experienced employees.
business.
• Ekotek economizers make use of the waste heat of the flue
• It can be easily cleaned with its suitable manufacturing
gases; They are the devices that provide the heating of the
feed water, the hot air needs and the domestic hot water
needs.
• Economizer indoor unit is optionally manufactured from
316 L stainless seamless pipes.

A B

C H
TEMPERATURE

TEMPERATURE
INPUT-OUTPUT

INLET-OUTPUT

APPROXIMATE
FEED WATER

ECONOMIZER
BOILER FLANGERS
WEIGHT
SMOKE

CAPACITY WATER
MODEL CAPACITY Dimensions FLOW
TO BE USED
WATER WATER
INLET OUTPUT

BİRİM KCAL/H KCAL/H A B C H °C °C KG/H


EKONOMİZER -1 65.000 1.000.000 1170 1065 300 x 300 870 240/130 102/135 2000 20 20 1400
EKONOMİZER -2 125.000 2.000.000 1270 1275 350 x 350 1220 240/130 102/135 4000 25 25 2000
EKONOMİZER -3 200.000 3.000.000 1470 1275 400 x 400 1430 240/130 102/135 6000 32 32 2400
EKONOMİZER -4 255.000 4.000.000 1670 1625 500 x 500 1515 240/130 102/135 8000 40 40 2800
EKONOMİZER -5 320.000 5.000.000 1770 1625 550 x 550 1915 240/130 102/135 10000 40 40 3300
EKONOMİZER -6 375.000 6.000.000 1870 1625 600 x 600 2300 240/130 102/135 12000 40 40 4000
EKONOMİZER -8 500.000 8.000.000 2070 1910 700 x 700 2445 240/130 102/135 16000 50 50 5000
EKONOMİZER -10 650.000 10.000.000 2270 2325 800 x 800 2350 240/130 102/135 19000 50 50 6200
EKONOMİZER -12 750.000 12.000.000 2470 2325 900 x 900 2880 240/130 102/135 22000 65 65 6500
EKONOMİZER -15 900.000 15.000.000 2670 2325 1000 x 1000 3450 240/130 102/135 28000 80 80 7200

EKOTEK HEAT TECHNOLOGIES HAVE THE RIGHT TO MAKE


CHANGES IN STANDARDS, DESIGNS, VS, DIMENSIONS, WEIGHTS AND MODELS WITHOUT NOTICE.

Contact : +90 256 231 15 95 47


TRANSFORM SERIES
125.000 Kcal/h – 2.000.000 Kcal/h Heat capacity

SOLID FUEL HOT


AIR BOILER
GENERAL INFORMATION AND MATERIAL QUALITY
• Lignite coal, olive pomace, Pine cone, PELET etc. to be used
• Our company is controlled and audited by EKOTEK, Brand
in all areas where hot air is needed. They are high efficiency
registered and ISO 9001:2015 quality management system.
boilers that can burn granular fuels; Factory, Greenhouse,
• Welding processes are carried out by certified welders in
Hangars, Sports Halls, Chicken Farm as well as Pine Nuts, Figs,
accordance with approved WPS and WPQRs.
Cotton, Timber etc. It is designed to be used for drying
• The products used in production are all certified materials.
products.
• Our products have been produced in accordance with the
• Thanks to its 4-pass design, it distributes the heat obtained
2014/68/EU Pressure Vessels directive and have a CE
equally to all surfaces, providing maximum heat transfer and
certificate.
fuel savings.
• Our products are manufactured according to EN288, EN287-1
• Our boilers do not cause noise pollution with their silent
using S 235 JR quality boiler sheet.
operation.
• Our products are manufactured using boiler pipes made of
• Air sent to the primary with the help of a fan; It provides a
P235GH and higher quality steel in accordance with TS EN
controlled and clean smokeless combustion.
10217-2 norm.
• Our products, with a capacity range of 100,000 Kcal/h -
• Combustion chamber and first pass pipes will be made of
2,000,000 Kcal/h, have a high temperature resistant
stainless material, other parts will be made of S 235 JR black
combustion chamber and a cast iron furnace.
sheet. Insulation 100mm rock wool (Our boiler is 4-pass,
• More heating is provided with less fuel.
automatic loading) (The furnace design is made of partly cast
• By keeping the desired air temperature constant with the
iron.)
thermostat control, fuel savings are maximized.
• Our boilers are designed for minimum 4.500 kcal/h (flame
• Thanks to the Turbo Fan system, secondary combustion is
temperature 1200 C°) fuel. Please contact our company to
ensured and it provides 20-40% savings in fuel.
burn lower calorie fuel..

DIMENSIONS ø

APPROXIMATE
RECOM. MIN.

FUEL TANK
CHIMNEY

WEIGHT

FAN CAPACITY
MODEL CAPACITY Dimensions
FLOW
OLIVE
COAL POMANCE

BİRİM KCAL/H KW MW A A1 B C D E H L L1 L2 M3/H KG KG øMM KG


TRANSFORM 100A 125.000 116 0,12 900 700 1600 2750 300 250 2250 800 1650 1100 13000 240 210 225 1200

TRANSFORM 150A 250.000 174 0,17 1050 800 1850 2750 350 250 2400 800 1650 1100 19000 240 210 250 1400
TRANSFORM 200A 350.000 232 0,23 1150 800 1950 3000 350 300 2450 1000 1900 1100 19000 240 210 300 1700

TRANSFORM 250A 500.000 290 0,29 1250 950 2200 3350 400 300 2750 1000 2000 1350 23000 240 210 350 2250

TRANSFORM 300A 650.000 348 0,35 1250 1150 2400 3500 400 300 2750 1100 2150 1350 27000 300 260 350 2800

TRANSFORM 400A 750.000 465 0,47 1400 1250 2650 3650 450 350 3000 1200 2300 1350 28000 300 260 450 3400

TRANSFORM 500A 1.000.000 581 0,58 1400 1400 2800 3650 450 350 3350 1200 2300 1350 38000 300 260 450 3900
TRANSFORM 600A 1.250.000 697 0,70 1400 1600 3000 3950 500 400 3450 1500 2700 1450 39000 300 260 500 4600

TRANSFORM 700A* 1.500.000 813 0,81 1500 1600 3100 4100 550 400 3450 1600 2850 1450 39000 400 350 550 5250
TRANSFORM 800A* 1.750.000 930 0,93 1500 1700 3200 4300 550 450 3450 1800 3100 1600 43000 400 350 550 6000

TRANSFORM 1000A* 2.000.000 1162 1,16 1800 1800 3600 4450 600 500 4000 1850 3250 1600 59000 400 350 600 7100

EKOTEK HEAT TECHNOLOGIES HAVE THE RIGHT TO MAKE


CHANGES IN STANDARDS, DESIGNS, VS, DIMENSIONS, WEIGHTS AND MODELS WITHOUT NOTICE.

NOTE: The recommended chimney diameter is calculated as an average of 400 m altitude.


The diameter of the chimney is the minimum size and may vary.

48 www.ekotekkazan.com
FAST SERIES
125.000 Kcal/h – 2.500.000 Kcal/h Heat capacity

LIQUID /GAS FUEL


HOT AIR BOILERS

GENERAL INFORMATION AND MATERIAL QUALITY • Pe max: 300 or pe 21 mbar gas line to the burner according
• Our company is controlled and audited by EKOTEK, Brand to the burner gas pressure. For the gas line, get information
registered and ISO 9001:2015 quality management system. from our company.
• Ultrasonic, radiographic and penetrating tests are performed • Do not forget to have a ce and tse certified chimney made
by the authorized company for our resources. for natural gas. Do not forget to get a chimney offer suitable
• Welding processes are carried out by certified welders in for natural gas from our company.
accordance with approved WPS and WPQR. Welding • It has the flexibility to work in harmony with different
processes are subjected to radiographic testing at the rates combustion systems.
prescribed by the standards. • Thanks to the Turbo Fan system, secondary combustion is
• The products used in production are all certified materials. ensured and it provides 20-40% savings in fuel.
• Our products are manufactured according to EN288, EN287-1 • Thanks to its 3-pass design, it distributes the heat obtained
using S 235 JR quality boiler sheet. equally to all surfaces, providing maximum heat transfer and
• Our products are manufactured using boiler pipes made of fuel savings.
P235GH and higher quality steel in accordance with TS EN • Our boilers do not cause noise pollution with their silent
10217-2 norm. operation.
• Combustion chamber and first pass pipes will be made of • More heating is provided with less fuel.
stainless material, other parts will be made of S 235 JR black • By keeping the desired air temperature constant with the
sheet. Insulation The heat loss is at the lowest level by thermostat control, fuel savings are maximized.
insulating with 100mm rock wool. • Our products have a high temperature resistant combustion
• Get support from engineering companies for central system chamber and a cast iron furnace.
gas opening works.
APPROXIMATE

FUEL TANK
WEIGHT

FAN CAPACITY
MODEL CAPACITY Dimensions FLOW
COAL OLIVE
POMANCE

BİRİM KCAL/H KW MW A A1 B C D E H L M3/H øMM øMM KG


FAST 125 125.000 145 0,15 750 800 1550 1450 300 250 2000 650 19000 200 200 950
FAST 250 250.000 290 0,29 900 950 1850 1650 300 250 2250 800 23000 300 250 1150

FAST 350 350.000 406 0,41 1050 1150 2200 1650 350 250 2400 800 27000 350 300 1350

FAST 500 500.000 581 0,58 1150 1400 2550 1900 350 300 2450 1000 38000 400 350 1625

FAST 650 650.000 755 0,76 1250 1600 2850 2000 400 300 2750 1000 39000 450 450 2175

FAST 750 750.000 872 0,87 1250 1600 2850 2150 400 300 2750 1100 39000 500 450 2700
FAST 1000 1.000.000 1162 1,16 1400 1750 3150 2300 450 350 3000 1200 59000 500 500 3210

FAST 1250 1.250.000 1453 1,45 1400 1900 3300 2300 450 350 3350 1200 65000 550 550 3790
FAST 1500 1.500.000 1744 1,74 1400 1900 3300 2700 500 400 3450 1500 75000 600 550 4450

FAST 1750 1.750.000 2034 2,03 1500 2100 3600 2850 500 400 3450 1600 87500 650 600 5100

FAST 2000 2.000.000 2325 2,33 1500 2100 3600 3100 550 450 3450 1800 100000 700 650 5750

FAST 2500 2.500.000 2906 2,91 1800 2400 4200 3250 600 500 4000 1850 125000 750 700 6950
EKOTEK HEAT TECHNOLOGIES HAVE THE RIGHT TO MAKE
CHANGES IN STANDARDS, DESIGNS, VS, DIMENSIONS, WEIGHTS AND MODELS WITHOUT NOTICE.

NOTE: The recommended chimney diameter is calculated as an average of 400 m altitude.


The diameter of the chimney is the minimum size and may vary.

Contact : +90 256 231 15 95 49


OCEAN SERIES
80.000 Kcal/h- 2.000.000 Kcal/h heat capacity

SOLID FUEL
SUPER HEATING WATER BOILER
• Our products are manufactured in accordance with EN288,
EN287-1 by using P 265 GH and P 355 GH quality boiler sheet.
• Our products are manufactured using boiler pipes made of
P235GH and higher quality steel in accordance with TS EN
10217-2 norm.
• Burns all solid fuels with high efficiency.
• Thanks to the nitrogen balance tank, it prevents the
GENERAL INFORMATION AND MATERIAL QUALITY
evaporation of boiler and installation water.
• Our company EKOTEK, Brand registered and ISO 9001:2015
• It is designed to disperse thermal stresses at high pressure.
quality
• It can be manufactured in capacities to meet high energy
It is controlled and supervised by the management system.
needs.
• Ultrasonic, radiographic and penetrating tests are
• It can be applied in systems where hot oil and steam cannot
performed by the authorized company for our resources.
be used.
• Welding processes are carried out by certified welders in
• Computer aided production in accordance with design
accordance with approved WPS and WPQRs.
standards, CE pressure vessels directive, TRD, EN, TSE standards.
Welding processes are subjected to radiographic testing at
• It provides ease of use with a working pressure between 2 Bar
the rates stipulated by the standards.
and 16 Bar and up to 200°C.
• The products used in production are all certified materials.
• Pay attention to the pressure, temperature and flow rate while
• Our products, TS EN 12953-1-3, TS
choosing the pump in the hot water boiler. Get support from
377-1-2-3-4-5-6-7-8-10-11-12-14, TS EN 12953-1-2-3-4- It is
our company.
produced in accordance with 5-6-7-8-10-11-12-14 standards
• Our boilers are designed for minimum 4.500 kcal/h (flame
and 2014/68/EU Pressure Vessels directive and has CE
temperature 1200 C°) fuel. Please contact our company to burn
certificate.
lower calorie fuel.
A

K
H

C L B D
BOILER FLANGES
DIMENSIONS ø

APPROXIMATE
FUEL TANK
RECOM. MIN.

PROPERTIES
INSULATION
OPERATING
PRESSURE

CHIMNEY
DISCHARGE

WEIGHT
VOLUME

CAPACITY
WATER

SAFETY
OUTPUT

MODEL CAPACITY Dimensions


WATER

WATER
INLET

OLIVE
COAL POMANCE

BİRİM KCAL/H KW MW A B C D H K L LT DN DN DN DN BAR KG KG øMM MM KG


OCEAN 80A 80.000 93 0,09 1675 760 500 750 1350 200 1200 230 50 50 25 25 6 150 125 200 100 763
OCEAN 100A 100.000 116 0,12 1875 760 500 750 1350 225 1400 255 50 50 25 25 6 150 125 225 100 775
OCEAN 130A 130.000 151 0,15 1950 860 500 750 1550 250 1500 315 50 50 32 25 6 150 125 250 100 900
OCEAN 150A 150.000 174 0,17 2100 870 500 750 1550 250 1650 360 50 50 32 25 6 150 125 250 100 1050
OCEAN 160A 160.000 186 0,19 2210 870 500 750 1550 250 1750 375 65 65 32 25 6 200 175 250 100 1200
OCEAN 200A 200.000 232 0,23 2350 940 500 1050 1750 300 1750 475 65 65 32 25 6 200 175 300 100 1320
OCEAN 230A 230.000 267 0,27 2350 1000 550 1050 1750 350 1750 475 65 65 32 25 6 200 175 350 100 1400
OCEAN 250A 250.000 290 0,29 2500 1060 550 1050 1800 350 1925 600 80 80 40 25 6 200 175 350 100 1650
OCEAN 280A 280.000 325 0,33 2500 1100 550 1050 1800 350 1925 600 80 80 40 25 6 200 175 350 100 1760
OCEAN 300A 300.000 348 0,35 2650 1110 550 1050 1800 350 2000 753 80 80 40 25 6 200 175 350 100 1900
OCEAN 330A 330.000 383 0,38 2650 1160 550 1050 1800 400 2000 753 80 80 40 25 6 200 175 400 100 2080
OCEAN 350A 350.000 406 0,41 2750 1160 600 1050 1850 400 2100 890 80 80 40 25 6 200 175 400 100 2950
OCEAN 400A 400.000 465 0,47 2950 1300 600 1050 2060 450 2250 1032 80 80 40 25 6 200 175 450 100 3100
OCEAN 450A 450.000 523 0,52 3150 1300 600 1050 2060 450 2350 1032 80 80 40 25 6 200 175 450 100 3850
OCEAN 500A 500.000 581 0,58 3250 1520 700 1050 2100 450 2500 1125 100 100 50 25 8 200 175 450 100 4560
OCEAN 600A 600.000 697 0,70 3550 1520 700 1050 2200 500 2800 1355 100 100 50 25 8 200 175 500 100 4650
OCEAN 700A** 700.000 813 0,81 3550 1620 700 1200 2270 550 2800 1550 100 100 50 25 8 400 350 550 100 5700
OCEAN 800A** 800.000 930 0,93 3750 1620 750 1200 2270 550 3000 1940 100 100 50 25 8 400 350 550 100 6560
OCEAN 900A** 900.000 1046 1,05 3750 1740 750 1200 2300 600 3000 2200 100 100 50 25 8 400 350 600 100 7100
OCEAN 1000A** 1.000.000 1162 1,16 3960 1740 800 1200 2380 600 3200 2945 125 125 50 25 8 400 350 600 100 7950
OCEAN 1250A** 1.250.000 1453 1,45 4300 1860 800 1200 2500 650 3500 3130 125 125 50 25 8 400 350 650 100 8750
OCEAN 1500A** 1.500.000 1744 1,74 4800 1860 800 1200 2500 700 4000 3250 125 125 65 25 10 400 350 700 100 10000
OCEAN 2000A** 2.000.000 2325 2,33 5050 1900 800 1200 2580 80 4250 4350 125 125 65 25 10 400 350 800 100 12450

EKOTEK HEAT TECHNOLOGIES HAVE THE RIGHT TO MAKE


CHANGES IN STANDARDS, DESIGNS, VS, DIMENSIONS, WEIGHTS AND MODELS WITHOUT NOTICE.
NOTE: The recommended chimney diameter is calculated as an average of 400 m altitude.
50 The diameter of the chimney is the minimum size and may vary.
ATLAS SERIES
80.000 Kcal/h – 6.000.000 Kcal/h heat capacity

LIQUID/ GAS FUEL


SUPERHEATING
WATER BOILER
GENERAL INFORMATION AND MATERIAL QUALITY
• Do not forget to have a ce and tse certified chimney made for natural
• Our company is controlled and audited by EKOTEK, Brand registered
gas. Do not forget to get a chimney offer suitable for natural gas from
and ISO 9001:2015 quality management system.
our company.
• Ultrasonic, radiographic and penetrating tests are performed by the
• It has the flexibility to work in harmony with different combustion
authorized company for our resources.
systems.
• Welding processes are carried out by certified welders in accordance
• Minimum fuel consumption and operating costs are ensured thanks
with approved WPS and WPQRs. Welding processes are subjected to
to the ease of operation and maintenance and burner combustion
radiographic testing at the rates stipulated by the standards.
control.
• The products used in production are all certified materials.
• Thanks to the nitrogen balance tank, it prevents the evaporation of
• Our products, TS EN 12953-1-3, TS 377-1-2-3-4-5-6-7-8-10-11-12-14, TS EN
boiler and installation water.
12953-1-2-3-4- It is produced in accordance with 5-6-7-8-10-11-12-14
• Small size and high performance.
standards and 2014/68/EU Pressure Vessels directive and has CE
• It has a construction and manufacturing suitable for working at high
certificate.
pressure.
• Our products are manufactured in accordance with EN288, EN287-1
• It is designed to disperse thermal stresses at high pressure.
by using P 265 GH and P 355 GH quality boiler sheet.
• It can be manufactured in capacities to meet high energy needs.
• Our products are manufactured using boiler pipes made of P235GH
• It can be applied in systems where hot oil and steam cannot be used.
and higher quality steel in accordance with TS EN 10217-2 norm.
• Computer aided production in accordance with design standards, CE
• Get support from engineering companies for central system gas
pressure vessels directive, TRD, EN, TSE standards.
opening works. For the burner pe max: 300 or pe 21 mbar gas line
• It provides ease of use with a working pressure between 2 Bar and 16
according to the burner gas pressure, please get information from
Bar and up to 200°C.
our company for the gas line.

APPROXIMATE
BOILER FLANGES

PROPERTIES
INSULATION
OPERATING
PRESSURE

PRESSURE
COUNTER-

WEIGHT
DISCHARGE
VOLUME

OUTPUT

SAFETY
WATER
WATER

WATER
MODEL CAPACITY

INLET
Dimensions

BİRİM KCAL/H KW A B C D H K L LT DN DN DN DN BAR BAR MM KG


ATLAS 100 100.000 116 1450 600 550 700 1100 150 1070 260 50 50 25 25 3 0,9 100 765

ATLAS 130 130.000 151 1590 700 550 800 1150 170 1200 275 50 50 32 25 3 1 100 860

ATLAS 150 150.000 174 1700 700 550 800 1150 170 1300 320 65 65 32 25 3 1,5 100 900

ATLAS 160 160.000 186 1800 750 550 850 1250 200 1300 380 65 65 32 25 3 1,5 100 1200

ATLAS 200 200.000 233 1900 750 550 850 1250 200 1420 420 65 65 32 25 3 2 100 1290

ATLAS 250 250.000 291 1900 820 550 920 1370 200 1420 515 80 80 40 25 3 2,5 100 1450

ATLAS 300 300.000 348 2120 1000 600 1100 1500 250 1550 675 80 80 40 25 3 3 100 1760

ATLAS 350 350.000 407 2400 1000 600 1100 1500 250 1800 720 80 80 40 25 3 3,5 100 1980

ATLAS 400 400.000 465 2600 1000 600 1100 1550 250 1900 970 80 80 40 25 3 4 100 2370

H ATLAS 450 450.000 523 2600 1100 700 1200 1650 250 1900 1050 100 100 50 25 4 4,3 100 2670

ATLAS 500 500.000 581 2750 1300 700 1400 1800 300 1950 1230 100 100 50 25 4 4,7 100 3190

ATLAS 600 600.000 697 2800 1300 700 1400 1800 300 2050 1320 100 100 50 25 4 5 100 3750

ATLAS 700 700.000 814 2950 1300 700 1400 1850 350 2200 1585 100 100 50 25 4 5 100 4050

ATLAS 800 800.000 930 3100 1420 700 1520 2000 350 2250 2105 100 100 50 25 4 5 100 4300

ATLAS 900 900.000 1046 3250 1550 700 1650 2150 400 2400 2350 125 125 65 32 5 5,4 100 4700

ATLAS 1000 1.000.000 1162 3550 1550 700 1650 2150 450 2700 3100 125 125 65 32 5 6 100 4950
B ATLAS 1250 1.250.000 1453 3550 1600 750 1700 2200 500 2700 3290 125 125 65 32 5 6 100 5100

ATLAS 1500 1.500.000 1744 3750 1620 750 1720 2250 550 2900 3450 150 150 80 32 5 6,5 100 5300

ATLAS 1750 1.750.000 2035 3750 1750 750 1850 1380 550 2900 4750 150 150 80 32 5 6,5 100 5750
A ATLAS 2000 2.000.000 2325 4000 1800 750 1900 2450 600 3150 6120 150 150 80 40 6 6,5 100 6070

ATLAS 2500 2.500.000 2907 4150 1850 800 1950 2500 650 3250 7040 150 150 80 40 6 7 100 7400

ATLAS 3000 3.000.000 3488 4550 1950 800 2050 2610 700 3650 8450 200 200 80 40 6 7 100 8350
K
ATLAS 3500 3.500.000 4070 4950 2050 800 2150 2750 750 4000 10200 200 200 80 40 6 7,5 100 9100
D
ATLAS 4000 4.000.000 4651 4950 2150 1000 2260 2900 800 4000 11850 200 200 80 40 6 8 100 10900

ATLAS 4500 4.500.000 5233 5750 2250 1000 2350 3000 850 4500 13500 200 200 80 40 6 8 100 12650

ATLAS 5000 5.000.000 5232 5750 2350 1000 2500 3100 900 4500 14250 200 200 80 40 6 8 100 14750
D1
C L ATLAS 6000 6.000.000 6977 5750 2400 1000 2500 3200 1000 4500 15600 200 200 80 40 6 9 100 16250

ATLAS 7000 7.000.000 8140 6150 2550 1000 2650 3350 1100 4900 18500 200 200 80 40 6 9 100 18700

ATLAS 8000 8.000.000 9302 7000 2900 1250 3000 3700 1200 5750 19400 250 250 100 40 6 9 100 20350

ATLAS 9000 9.000.000 10465 7650 2950 1250 3050 3750 1300 6250 20750 250 250 100 60 6 9 100 21900

ATLAS 10000 10.000.000 11628 8200 3100 1250 3000 3650 1400 6750 21900 300 300 100 60 6 9,5 100 24350

ATLAS 17000 17.000.000 19767 8200 3350 1250 3300 3950 1500 6800 25750 300 300 100 60 6 9,5 100 27750

ATLAS 19000 19.000.000 22093 8250 3750 1300 3700 4350 1600 6650 31000 350 350 120 80 6 9,5 100 29500

ATLAS 20000 20.000.000 23256 8300 3800 1300 3750 4400 1650 6950 33350 350 350 120 80 6 9,5 100 36000

EKOTEK HEAT TECHNOLOGIES HAVE THE RIGHT TO MAKE


CHANGES IN STANDARDS, DESIGNS, VS, DIMENSIONS, WEIGHTS AND MODELS WITHOUT NOTICE.
NOTE: The recommended chimney diameter is calculated as an average of 400 m altitude.
51
The diameter of the chimney is the minimum size and may vary.
LOCOMOTIVE SERIES
25.000 KCAL/H-1.500.000 KCAL/H heat capacity

CENTRAL SYSTEM 3 PASS


MANUAL LOADING FLOOR
FUEL HOT WATER BOILER

• Our boilers do not cause noise pollution with their silent


GENERAL INFORMATION AND MATERIAL QUALITY
operation.
• Our company is controlled and audited by EKOTEK, Brand
• Air sent to the Primary and Secondary with the help of a fan;
registered and ISO 9001:2015 quality management system. Our
It provides a controlled and clean smokeless combustion.
products are TSE CERTIFIED products.
• Thanks to its three-pass design, it distributes the heat
• Welding processes are carried out by certified welders in
obtained equally to all surfaces, providing maximum heat
accordance with approved WPS and WPQRs.
transfer and fuel savings.
• The products used in production are all certified materials.
• Thanks to its high heating surface without the need for a
• Our boilers produced in TS EN 497 standards are certified
stoker, the fuel tank provides 1-3 days of burning continuity.
with 97/23/AT Pressure Equipment Regulation module H Full
• More heating is provided with less fuel.
Quality Assurance.
• Fuel savings are maximized by keeping the water
• Our products are manufactured using ST-37 quality sheet
temperature constant with the thermostat control.
metal.
• Our products are manufactured using boiler pipes made of B
A
P235GH and higher quality steel in accordance with TS EN
10217-2 norm.
• With the insulation we have made in our boilers, we K
minimize heat losses and provide fuel savings.
• Although it is optional in our boilers, antifreeze can be used H
against the risk of freezing in the installation.
• Single flat and double flat central system that can fit into the
narrowest spaces. They can burn granular fuels and are highly
efficient boilers.
• Our boilers are designed for minimum 4.500 kcal/h (flame
temperature 1200 C°) fuel. Please contact our company to C L D
burn lower calorie fuel.
BOILER FLANGES

APPROXIMATE
OPERATING
PRESSURE

PRESSURE
COUNTER-
DISCHARGE

WEIGHT
VOLUME

OUTPUT

SAFETY
WATER

WATER

WATER
INLET

MODEL CAPACITY Dimensions

BİRİM KCAL/H KW MW A B C D H K L LT DN DN INCH INCH BAR MM KG


LOCOMOTIVE 25M 25.000 29 0,03 925 650 500 1400 1190 170 500 125 1 1/4'' 1 1/4'' 3/4 1/2 2 50 342

LOCOMOTIVE 40M 40.000 47 0,05 925 650 500 1400 1310 170 500 155 1 1/4'' 1 1/4'' 3/4 1/2 2 50 395

LOCOMOTIVE 60M 60.000 70 0,07 1140 650 500 1400 1470 170 700 185 1 1/2'' 1 1/2'' 3/4 1/2 2 50 503

LOCOMOTIVE 80M 80.000 93 0,09 1550 790 500 1540 1415 220 1070 230 2'' 2'' 1 1 3 100 728

LOCOMOTIVE 100M 100.000 116 0,12 1620 830 500 1580 1440 220 1130 255 2'' 2'' 1 1 3 100 722

LOCOMOTIVE 130M 130.000 151 0,15 1755 870 500 1620 1610 220 1255 315 50 50 1 1/4 1 3 100 865

LOCOMOTIVE 150M 150.000 174 0,17 1895 870 550 1620 1610 220 1385 360 50 50 1 1/4 1 3 100 1165

LOCOMOTIVE 160M 160.000 186 0,19 1895 970 550 1920 1685 220 1385 380 65 65 1 1/4 1 3 100 1192

LOCOMOTIVE 200M 200.000 233 0,23 2250 1100 550 2050 1770 270 1620 485 65 65 1 1/2 1 3 100 1570

LOCOMOTIVE 250M 250.000 291 0,29 2370 1160 550 2110 1830 320 1740 610 80 80 1 1/2 1 3 100 1765

LOCOMOTIVE 300M 300.000 349 0,35 2370 1300 550 2250 2075 400 1740 650 80 80 1 1/2 1 3 100 2075

LOCOMOTIVE 350M 350.000 407 0,41 2370 1400 600 2350 2075 400 1740 910 80 80 1 1/2 1 3 100 2395

LOCOMOTIVE 400M 400.000 465 0,47 2720 1400 600 2350 2075 400 1940 960 80 80 1 1/2 1 3 100 2590

LOCOMOTIVE 500M 500.000 581 0,58 3110 1520 600 2620 2205 400 2330 1155 100 100 2 1 4 100 3305

LOCOMOTIVE 600M 600.000 698 0,70 3110 1620 700 2720 2335 400 2330 1205 100 100 2 1 4 100 4090

LOCOMOTIVE 700M 700.000 814 0,81 3110 1740 700 2840 2385 450 2330 1465 100 100 2 1 4 100 4675

LOCOMOTIVE 800M 800.000 930 0,93 3550 1740 700 2840 2385 450 2625 1960 100 100 2 1 4 100 5215

LOCOMOTIVE 900M 900.000 1047 1,05 3850 1740 750 2840 2385 450 2925 2210 100 100 2 1 4 100 5905

LOCOMOTIVE 1000M 1.000.000 1163 1,16 3850 1860 750 2960 2480 500 2925 2955 125 125 2 1 5 100 6075

LOCOMOTIVE 1250M 1.250.000 1453 1,45 4450 1960 800 3060 2580 500 3500 3160 125 125 2 1 5 100 7215

LOCOMOTIVE 1500M 1.500.000 1744 1,74 4450 1960 800 3060 2655 550 3500 3280 125 125 2 1/2 1 5 100 7915

EKOTEK HEAT TECHNOLOGIES HAVE THE RIGHT TO MAKE


CHANGES IN STANDARDS, DESIGNS, VS, DIMENSIONS, WEIGHTS AND MODELS WITHOUT NOTICE.

NOTE: The recommended chimney diameter is calculated as an average of 400 m altitude.


The diameter of the chimney is the minimum size and may vary.

52 www.ekotekkazan.com
SAVING SERIES
25.000 KCAL/H-60.000 KCAL/H heat capacity

INDIVIDUAL 3 PASS SOLID


FUEL AUTOMATIC FEEDING
HOT WATER BOILER

• Although it is optional in our boilers, antifreeze can be used


GENERAL INFORMATION AND MATERIAL QUALITY against the risk of freezing in the installation.
• Our company is controlled and audited by EKOTEK, Brand • Our single and double flat heating boilers, which can fit into
registered and ISO 9001:2015 quality management system. the narrowest spaces, can be used with COAL, PEA,
Our products are TSE CERTIFIED products. HAZELNUT SHELLS, PINE CONCEA, etc. It can burn granular
• Welding processes are carried out by certified welders in fuels and provides high efficiency.
accordance with approved WPS and WPQRs. • Air sent to the primary with the help of a fan; It provides a
• The products used in production are all certified materials. controlled and clean smokeless combustion.
• Our boilers produced in TS EN 497 standards are certified • Fuel supply is from the bottom and direct contact of the
with 97/23/AT Pressure Equipment Regulation module H Full flame with the combustion chamber is provided.
Quality Assurance. • More heating is provided with less fuel.
• Our products are manufactured using S 235 JR quality • Thanks to its three-pass design, it distributes the heat
sheet metal. obtained equally to all surfaces, providing maximum heat
• Our products are manufactured using boiler pipes made of transfer and fuel savings.
P235GH and higher quality steel in accordance with TS EN • It provides ease of use in individual heating with its
10217-2 norm. capacities in the range of 25,000 - 60,000 KCAL/h.
• With the insulation we have made in our boilers, we • By keeping the water temperature constant with the
minimize heat losses and provide fuel savings. thermostat control, fuel savings are maximized.
• Our boilers are designed for minimum 4.500 kcal/h (flame
temperature 1200 C°) fuel. Please contact our company to
burn lower calorie fuel.

BOILER FLANGES FUEL TANK


APPROXIMATE
PROPERTIES
INSULATION
OPERATING
PRESSURE

CAPACITY
DISCHARGE

WEIGHT
VOLUME
WATER

SAFETY
OUTPUT

MODEL CAPACITY
WATER

WATER

Dimensions
INLET

OLIVE
COAL POMANCE

BİRİM KCAL/H KW A B C D H K L L1 LT INCH INCH INCH INCH KG KG BAR MM KG


SAVING 25A 25.000 29 1140 645 940 730 1160 170 500 210 125 1 1/4 1 1/4 3/4 1/2 85 75 2 50 367

SAVING 40A 40.000 46 1140 645 965 730 1300 170 500 230 155 1 1/4 1 1/4 3/4 1/2 85 75 2 50 413

SAVING 60A 60.000 69 1190 700 1190 730 1465 170 700 230 185 1 1/2 1 1/2 3/4 1/2 125 100 2 50 525

EKOTEK HEAT TECHNOLOGIES HAVE THE RIGHT TO MAKE


CHANGES IN STANDARDS, DESIGNS, VS, DIMENSIONS, WEIGHTS AND MODELS WITHOUT NOTICE.

NOTE: The recommended chimney diameter is calculated as an average of 400 m altitude.


The diameter of the chimney is the minimum size and may vary.

Contact : +90 256 231 15 95 53


OBUS SERIES
25.000 KCAL/H-100.000 KCAL/H heat capacity

INDIVIDUAL AUTOMATIC
4 PASS SOLID FUEL
HOT WATER BOILER

GENERAL INFORMATION AND MATERIAL QUALITY


• Our company is controlled and audited by EKOTEK, Brand
registered and ISO 9001:2015 quality management system. • Our single-flat and double-flat floor heating boilers, which
Our products are TSE CERTIFIED products. can fit into the narrowest spaces, are made of COAL, olive
• Welding processes are carried out by certified welders in pomace, HAZELNUT SHELLS, etc. They can burn granular
accordance with approved WPS and WPQRs. fuels and are highly efficient boilers.
• The products used in production are all certified materials. • Thanks to its 4-pass system, it provides the highest level of
• Our boilers produced in TS EN 497 standards are certified fuel savings, and thanks to its WOOD BURNING PIPE GRILL, it
with 97/23/AT Pressure Equipment Regulation module H Full provides efficiency and wood burning.
Quality Assurance. • Air sent to the primary with the help of a fan; It provides a
• Our products are manufactured using S235 JR quality sheet controlled and clean smokeless combustion.
metal. • Fuel supply is from the bottom and direct contact of the
• Our products are manufactured using boiler pipes made of flame with the inferno is provided.
P235GH and higher quality steel in accordance with TS EN • More heating is provided with less fuel.
10217-2 norm. • By keeping the water temperature constant with the
• With the insulation we have made in our boilers, we thermostat control, fuel savings are maximized.
minimize heat losses and provide fuel savings. • Our boilers are designed for minimum 4.500 kcal/h (flame
• Although it is optional in our boilers, antifreeze can be used temperature 1200 C°) fuel. Please contact our company to
against the risk of freezing in the installation. burn lower calorie fuel.

BOILER FLANGES FUEL TANK


APPROXIMATE
PROPERTIES
INSULATION
OPERATING
PRESSURE

CAPACITY
DISCHARGE

WEIGHT
VOLUME
WATER

MODEL
SAFETY
OUTPUT

CAPACITY Dimensions
WATER

WATER
INLET

OLIVE
COAL POMANCE

BİRİM KCAL/H KW A B C D H K L L1 LT INCH INCH INCH INCH KG KG BAR MM KG


OBUS 25A 25.000 29 1050 550 950 700 1265 170 500 230 125 1 1/4 1 1/4 3/4 1/2 85 75 2 50 367
OBUS 40A 40.000 46 1085 635 990 730 1280 170 500 230 164 1 1/4 1 1/4 3/4 1/2 85 75 2 50 437
OBUS 60A 60.000 69 1150 650 1250 750 1380 170 770 250 199 1 1/2 1 1/2 3/4 1/2 125 100 2 50 556
OBUS 80A 80.000 93 1150 650 1350 750 1450 200 800 275 230 1 1/2 1 1/2 3/4 1/2 125 100 3 50 720

OBUS 100A 100.000 116 1150 650 1500 750 1550 220 1000 275 260 1 1/2 1 1/2 3/4 1/2 125 100 3 50 880

EKOTEK HEAT TECHNOLOGIES HAVE THE RIGHT TO MAKE


CHANGES IN STANDARDS, DESIGNS, VS, DIMENSIONS, WEIGHTS AND MODELS WITHOUT NOTICE.
NOTE: The recommended chimney diameter is calculated as an average of 400 m altitude.
The diameter of the chimney is the minimum size and may vary.

54 www.ekotekkazan.com
TORCH SERIES
80.000 KCAL/H-3,000.000 KCAL/H HEAT CAPACITY

3 PASS CENTRAL SYSTEM SOLID


FUEL HOT WATER BOILER

• Single flat and double flat central system that can fit into the
GENERAL INFORMATION AND MATERIAL QUALITY
narrowest spaces. Different granular fuels COAL, Olive pomace,
• Our company is controlled and audited by EKOTEK, Brand registered
HAZELNUT SHELLS etc. They are boilers that can burn and provide high
and ISO 9001:2015 quality management system. Our products are TSE
efficiency.
CERTIFIED products.
• Air sent to the primary with the help of a fan; It provides a controlled
• Welding processes are carried out by certified welders in accordance
and clean smokeless combustion.
with approved WPS and WPQRs.
• Fuel supply is from the bottom and direct contact of the flame with
• The products used in production are all certified materials.
the inferno is provided.
• Our boilers produced in TS EN 497 standards are certified with
• Thanks to its three-pass design, it distributes the heat obtained equally
97/23/AT Pressure Equipment Regulation module H Full Quality
to all surfaces, providing maximum heat transfer and fuel savings.
Assurance.
• More heating is provided with less fuel.
• Our products are manufactured using S235 JR quality sheet metal.
• By keeping the water temperature constant with the thermostat
• Our products are manufactured using boiler pipes made of P235GH
control, fuel savings are maximized.
and higher quality steel in accordance with TS EN 10217-2 norm.
• Our boilers are designed for minimum 4.500 kcal/h (flame
temperature 1200 C°) fuel. Please contact our company to burn lower
calorie fuel.
FUEL TANK

APPROXIMATE
BOILER FLANGES

PROPERTIES
INSULATION
OPERATING
PRESSURE
DISCHARGE

WEIGHT
CAPACITY
VOLUME
WATER

OUTPUT

SAFETY
WATER

MODEL CAPACITY
WATER

Dimensions
INLET

OLIVE
COAL POMANCE

BİRİM KCAL/H KW MW A B C D H K L LT DN DN INCH INCH KG KG BAR MM KG


Torch 80A 80.000 93 0,09 1500 790 500 750 1410 220 1000 185 2'' 2'' 1 1 150 125 3 100 655
Torch 100A 100.000 116 0,12 1700 790 500 750 1410 220 1200 215 2'' 2'' 1 1 150 125 3 100 710

Torch 120A 120.000 140 0,14 1825 900 550 750 1500 220 1300 230 2'' 2'' 1 1 150 125 3 100 740
Torch 130A 130.000 151 0,15 1825 900 550 750 1500 220 1325 285 2'' 2'' 1 1 150 125 3 100 860

Torch 150A 150.000 174 0,17 2150 900 600 750 1575 220 1520 340 50 50 1 1/4 1 200 175 3 100 980
Torch 160A 160.000 186 0,19 2150 960 600 750 1600 220 1520 360 50 50 1 1/4 1 200 175 3 100 1085
Torch 180A 180.000 209 0,21 2300 1020 600 750 1800 270 1650 385 65 65 1 1/4 1 200 175 3 100 1140
H
Torch 200A 200.000 233 0,23 2300 1020 600 850 1800 270 1700 420 65 65 1 1/4 1 200 175 3 100 1240
Torch 230A 230.000 267 0,27 2350 1090 600 850 1850 270 1750 450 65 65 1 1/4 1 200 175 3 100 1365
Torch 250A 250.000 291 0,29 2350 1090 600 850 1900 320 1750 575 65 65 1 1/4 1 200 175 3 100 1480

Torch 280A 280.000 326 0,33 2400 1150 600 850 1950 320 1800 600 80 80 1 1/2 1 200 175 3 100 1560
Torch 300A 300.000 349 0,35 2450 1175 600 850 2000 400 1850 690 80 80 1 1/2 1 200 175 3 100 1650
B D
Torch 330A 330.000 384 0,38 2550 1250 600 850 2000 400 1950 715 80 80 1 1/2 1 200 175 3 100 1800

Torch 350A 350.000 407 0,41 2650 1270 600 850 2000 400 2050 825 80 80 1 1/2 1 200 175 3 100 1910

Torch 370A 370.000 430 0,43 2650 1300 600 850 2050 400 2050 890 80 80 1 1/2 1 200 175 3 100 2010
Torch 400A 400.000 465 0,47 2700 1330 600 850 2050 400 2100 940 80 80 1 1/2 1 200 175 3 100 2450

Torch 450A 450.000 523 0,52 2900 1390 600 850 2100 400 2300 1020 80 80 1 1/2 1 200 175 3 100 3100 A
Torch 500A 500.000 581 0,58 3050 1450 600 850 2100 400 2450 1100 80 80 1 1/2 1 200 175 4 100 3450
Torch 520A 520.000 605 0,60 3100 1450 600 850 2150 400 2500 1135 80 80 1 1/2 1 200 175 4 100 3780

Torch 550A 550.000 640 0,64 3150 1450 600 850 2150 400 2550 1160 100 100 2 1 200 175 4 100 3985
K
Torch 600A 600.000 698 0,70 3200 1520 600 850 2220 400 2600 1280 100 100 2 1 200 175 4 100 4170

Torch 650A 650.000 756 0,76 3300 1520 650 850 2270 400 2680 1340 100 100 2 1 200 175 4 100 4430
Torch 700A** 700.000 814 0,81 3450 1550 700 950 2300 400 2750 1490 100 100 2 2 400 350 4 100 4950

Torch 750A** 750.000 872 0,87 3600 1620 700 950 2300 400 2900 1550 100 100 2 2 400 350 4 100 5100
Torch 800A** 800.000 930 0,93 3700 1620 750 950 2325 450 2950 1840 100 100 2 2 400 350 4 100 5800

Torch 850A** 850.000 988 0,99 3750 1620 790 950 2350 450 2960 1920 100 100 2 2 400 350 4 100 6150 C L
Torch 900A** 900.000 1.047 1,05 3800 1720 840 950 2370 450 2960 2150 100 100 2 2 400 350 4 100 6500

Torch 1000A** 1.000.000 1.163 1,16 4000 1760 850 950 2450 450 3150 2850 100 100 2 2 400 350 5 100 7560
Torch 1250A** 1.250.000 1.453 1,45 4250 1810 850 950 2570 500 3400 3075 125 125 2 2 400 350 5 100 7950

Torch 1500A** 1.500.000 1.744 1,74 4500 1850 850 950 2630 500 3700 3200 125 125 2 1/2 2 400 350 5 100 8750
Torch 1750A** 1.750.000 2.035 2,03 4600 1850 850 950 2720 500 3800 3400 125 125 2 1/2 2 400 350 5 100 10000

Torch 2000A** 2.000.000 2.326 2,33 4750 1950 850 950 2750 600 3900 4100 125 125 2 1/2 2 600 525 6 100 11750

Torch 2500A** 2.500.000 2.907 2,91 4950 2100 850 950 2800 650 4200 4550 125 125 2 1/2 2 600 525 6 100 12450

Torch 3000A** 3.000.000 3.488 3,49 5300 2280 850 950 2820 700 4450 4750 125 125 2 1/2 2 600 525 6 100 13750

EKOTEK HEAT TECHNOLOGIES HAVE THE RIGHT TO MAKE


CHANGES IN STANDARDS, DESIGNS, VS, DIMENSIONS, WEIGHTS AND MODELS WITHOUT NOTICE.
NOTE: The recommended chimney diameter is calculated as an average of 400 m altitude.
The diameter of the chimney is the minimum size and may vary.
Contact : +90 256 231 15 95 55
HYBRID SERIES
500.000 KCAL/H-10.000.000 KCAL/H HEAT CAPACITY

5 PASS SOLID FUEL BIOMASS


HOT WATER BOILER

GENERAL INFORMATION AND MATERIAL QUALITY • LIGNITE COAL, olive pomace, HAZELNUT SHELLS etc. They are
• Our company is controlled and audited by EKOTEK, Brand boilers that can burn granular fuels and provide high efficiency.
registered and ISO 9001:2015 quality management system. • Air sent to the primary with the help of a fan; It provides a
Our products are TSE CERTIFIED products. controlled and clean smokeless combustion.
• Welding processes are carried out by certified welders in • Provides 15% fuel savings compared to standard boiler designs.
accordance with approved WPS and WPQRs. • It is safe. Explosion does not occur as a result of compression of
• The products used in production are all certified materials. flammable gases.
• Our boilers produced in TS EN 497 standards are certified • Our boilers do not cause noise pollution with their silent
with 97/23/AT Pressure Equipment Regulation module H Full operation.
Quality Assurance. • With its stylish appearance, it is noticed with its compatibility in
• Our products are manufactured using S235 JR quality sheet the environment it is in.
metal. • With the insulation we have made in our boilers, we minimize
• Our products are manufactured using boiler pipes made of heat losses and provide fuel savings.
P235GH and higher quality steel in accordance with TS EN • Although it is optional in our boilers, antifreeze can be used
10217-2 norm. against the risk of freezing in the installation.
• For systems that burn pellets, powder fuel, wood chips, etc. • Our boilers are designed for minimum 4.500 kcal/h (flame
for different fuel types, please contact us! temperature 1200 C°) fuel.
Please contact our company to burn lower calorie fuel.
• Easy to install.

BOILER FLANGES FUEL TANK


APPROXIMATE
PROPERTIES
INSULATION
OPERATING
PRESSURE
DISCHARGE

CAPACITY
WEIGHT
VOLUME
WATER

SAFETY
OUTPUT

MODEL
WATER

WATER

CAPACITY Dimensions
INLET

COAL OLIVE
POMANCE

BİRİM KCAL/H KW MW A B B1 C D H H1 K L LT DN DN INCH INCH KG KG BAR MM KG


HYBRID KY SSK 500 500.000 581 0,58 2850 1350 850 1050 1200 2550 500 450 2500 1050 80 80 2 1 200 175 4 100 3750

HYBRID KY SSK 600 600.000 698 0,70 3150 1350 850 1050 1200 2550 500 500 2700 1175 80 80 2 1 200 175 4 100 4300

HYBRID KY SSK 700 700.000 814 0,81 3400 1400 850 1100 1300 2700 500 550 2950 1370 100 100 3 2 400 350 5 100 5100

HYBRID KY SSK 800 800.000 930 0,93 3700 1500 850 1150 1400 2850 500 550 3150 1655 100 100 3 2 400 350 5 100 5900

HYBRID KY SSK 900 900.000 1047 1,05 3950 1550 850 1150 1400 2850 500 600 3400 1960 125 125 3 2 400 350 5 100 6600

HYBRID KY SSK 1000 1.000.000 1163 1,16 4200 1550 950 1350 1400 3050 500 600 3550 2275 125 125 4 2 400 350 5 100 7400
HYBRID KY SSK 1250 1.250.000 1453 1,45 4200 1750 950 1450 1500 3250 500 650 3550 2925 125 125 4 2 400 350 5 100 8400

HYBRID KY SSK 1500 1.500.000 1744 1,74 4400 1750 950 1700 1500 3500 500 700 3850 3510 150 150 4 2 400 350 6 100 9700

HYBRID KY SSK 2000 2.000.000 2326 2,33 5100 1850 1000 1700 1600 3600 500 800 4600 4630 150 150 4 2 600 525 6 100 10750

HYBRID KY SSK 2500 2.500.000 2907 2,91 5900 2000 1000 1950 1600 3850 500 900 5150 5785 150 150 4 2 600 525 6 100 11350

HYBRID KY SSK 3000 3.000.000 3488 3,49 6300 2100 1000 1950 1750 4000 500 1000 5550 6950 200 200 4 2 600 525 6 100 12100

HYBRID KY SSK 3500** 3.500.000 4070 4,07 6800 2100 1000 2200 1750 4250 750 1100 6150 8370 200 200 4 2 600 525 6 100 13700

HYBRID KY SSK 4000** 4.000.000 4651 4,65 7000 2250 1100 2300 1900 4500 750 1100 6250 10450 200 200 4 2 600 525 6 100 15300

HYBRID KY SSK 5000** 5.000.000 5814 5,81 7200 2400 1100 2250 2100 4650 750 1200 6450 12100 250 250 4 2 600 525 6 100 16900

HYBRID KY SSK 6000** 6.000.000 6977 6,98 7600 2700 1100 2450 2250 5000 750 1300 6750 13800 250 250 4 2 600 525 6 100 18500

HYBRID KY SSK 8000** 8.000.000 9302 9,30 8300 2950 1200 2600 2400 5600 750 1600 7350 14450 300 300 4 2 800 700 6 100 19300

HYBRID KY SSK 10000** 10.000.000 11628 11,63 8750 3100 1200 2600 2750 5950 750 1800 7600 15300 300 300 4 2 800 700 6 100 20700

EKOTEK HEAT TECHNOLOGIES HAVE THE RIGHT TO MAKE


CHANGES IN STANDARDS, DESIGNS, VS, DIMENSIONS, WEIGHTS AND MODELS WITHOUT NOTICE.
NOTE: The recommended chimney diameter is calculated as an average of 400 m altitude.
The diameter of the chimney is the minimum size and may vary.

56 www.ekotekkazan.com
MONSTER SERIES
700,000 KCAL/H-4,000,000 KCAL/H HEAT CAPACITY

3 PASS CENTRAL SYSTEM


SCOTCH TYPE SOLID FUEL
HOT WATER BOILER

GENERAL INFORMATION AND MATERIAL QUALITY •The central system that can fit into the narrowest spaces is
• Our company is EKOTEK, Brand registered and controlled COAL, olive pomace, HAZELNUT SHELLS etc. They are boilers
and audited by ISO 9001:2015 quality management system. that can burn granular fuels and provide high efficiency.
Our products are TSE CERTIFIED products. • Air sent to the primary with the help of a fan; It provides a
• Welding processes are carried out by certified welders in controlled and clean smokeless combustion.
accordance with approved WPS and WPQRs. • It is safe. Explosion does not occur as a result of compression
• The products used in production are all certified materials. of flammable gases.
• Our boilers produced in TS EN 497 standards are certified • Our boilers do not cause noise pollution with their silent
with 97/23/AT Pressure Equipment Regulation module H Full operation.
Quality Assurance. • With its stylish appearance, it is noticed with its compatibility
• Our products are manufactured using S235 JR quality sheet in the environment it is in.
metal. • Easy to install.
• Our products are manufactured using boiler pipes made of • Easy to Maintain.
P235GH and higher quality steel in accordance with TS EN • With the insulation we have made in our boilers, we minimize
10217-2 norm. heat losses and provide fuel savings.
• Our boilers are designed for minimum 4.500 kcal/h (flame • Although it is optional in our boilers, antifreeze can be used
temperature 1200 C°) fuel. Please contact our company to against the risk of freezing in the installation.
burn lower calorie fuel.

D L C
B

BOILER FLANGES
APPROXIMATE
PROPERTIES
INSULATION
OPERATING
PRESSURE
DISCHARGE

WEIGHT
VOLUME
WATER

SAFETY
OUTPUT
WATER

WATER

MODEL CAPACITY Dimensions


INLET

BİRİM KCAL/H KW MW A B C D H K L LT DN DN INCH INCH BAR MM KG


MONSTER 700 700.000 814 0,81 4800 1800 650 1650 2450 350 2500 1950 100 100 2 1 4 100 6100

MONSTER 800 800.000 930 0,93 5250 1900 650 1700 2600 350 2900 2270 100 100 2 1 4 100 6900

MONSTER 900 900.000 1.047 1,05 5500 1900 650 1700 2600 400 3150 3250 125 125 3 2 5 100 7350

MONSTER 1000 1.000.000 1.163 1,16 6000 2100 650 1950 2850 400 3400 4070 125 125 3 2 5 100 8400

MONSTER 1250 1.250.000 1.453 1,45 6450 2300 700 2000 3000 450 3750 5490 125 125 3 2 5 100 9260

MONSTER 1500 1.500.000 1.744 1,74 7000 2400 700 2200 3100 450 4100 6100 150 150 4 2 5 100 10370

MONSTER 1750* 1.750.000 2.035 2,03 7300 2500 750 2300 3200 500 4250 7160 150 150 4 2 5 100 11250

MONSTER 2000* 2.000.000 2.326 2,33 7800 2500 750 2300 3200 550 4750 8200 150 150 4 2 6 100 12700

MONSTER 2500* 2.500.000 2.907 2,91 8150 2750 800 2450 3450 600 4900 9700 150 150 4 2 6 100 13900

MONSTER 3000* 3.000.000 3.488 3,49 8850 2950 800 2650 3650 750 5400 11230 200 200 4 2 6 100 15150
MONSTER 4000* 4.000.000 4.651 4,65 9450 2950 800 2650 3650 850 6000 13400 200 200 4 2 6 100 16200

EKOTEK HEAT TECHNOLOGIES HAVE THE RIGHT TO MAKE


CHANGES IN STANDARDS, DESIGNS, VS, DIMENSIONS, WEIGHTS AND MODELS WITHOUT NOTICE.
NOTE: The recommended chimney diameter is calculated as an average of 400 m altitude.
The diameter of the chimney is the minimum size and may vary.
*CONTACT OUR COMPANY FOR DOUBLE COMBUSTION CHAMBER OR DIFFERENT CAPACITIES

Contact : +90 256 231 15 95 57


INDIVIDUAL
EKOPEL SERIES
25.000 KCAL/H-60.000 KCAL/H heat capacity

INDIVIDUAL HEATING EKOPEL


SOLID FUEL HOT WATER BOILER

GENERAL INFORMATION AND MATERIAL QUALITY • With the insulation we have made in our boilers, we
• Our company is controlled and audited by EKOTEK, Brand minimize heat losses and provide fuel savings.
registered and ISO 9001:2015 quality management system. • Although it is optional in our boilers, antifreeze can be used
Our products are TSE CERTIFIED products. against the risk of freezing in the installation.
• Welding processes are carried out by certified welders in • Thanks to its 3-pass design that can fit into the narrowest
accordance with approved WPS and WPQRs. spaces, it distributes the heat obtained equally to all surfaces,
• The products used in production are all certified materials. providing maximum heat transfer and fuel savings.
• Our boilers produced in TS EN 497 standards are certified • PELET, HAZELNUT SHELLS, LIGNITE COAL etc. It can burn
with 97/23/AT Pressure Equipment Regulation module H Full granular fuels and provides high efficiency.
Quality Assurance. • Our boilers do not cause noise pollution with their silent
• Our products are manufactured using S235 JR quality sheet operation.
metal. • More heating is provided with less fuel.
• Our products are manufactured using boiler pipes made of • It provides ease of use in individual heating with its
P235GH and higher quality steel in accordance with TS EN capacities in the range of 25,000 - 60,000 KCAL/h.
10217-2 norm. • By keeping the water temperature constant with the Digital
• Our boilers are designed for minimum 4.500 kcal/h (flame Control Panel, fuel savings are maximized.
temperature 1200 C°) fuel. Please contact our company to
burn lower calorie fuel.

BOILER FLANGES FUEL TANK


APPROXIMATE
OPERATING

PROPERTIES
PRESSURE

INSULATION

CAPACITY
DISCHARGE

WEIGHT
VOLUME
WATER

OUTPUT

SAFETY
WATER

WATER

MODEL CAPACITY Dimensions


INLET

OLIVE
COAL POMANCE

BİRİM KCAL/H KW A B C H K L LT INCH INCH INCH INCH KG KG BAR MM KG


EKOPEL 3G P 25 A 25.000 29 1535 650 750 1160 170 730 125 1 1/4 1 1/4 3/4 1/2 85 75 2 50 365
EKOPEL 3G P 40 A 40.000 46 1710 660 800 1300 170 840 155 1 1/4 1 1/4 3/4 1/2 85 75 2 50 425
EKOPEL 3G P 60 A 60.000 69 1920 670 850 1465 170 1100 185 1 1/2 1 1/2 3/4 1/2 125 100 2 50 539

EKOTEK HEAT TECHNOLOGIES HAVE THE RIGHT TO MAKE


CHANGES IN STANDARDS, DESIGNS, VS, DIMENSIONS, WEIGHTS AND MODELS WITHOUT NOTICE.

NOTE: The recommended chimney diameter is calculated as an average of 400 m altitude.


The diameter of the chimney is the minimum size and may vary.

58 www.ekotekkazan.com
EKOPEL SERIES
80.000 KCAL/H-1.500.000 KCAL/H heat capacity

CENTRAL HEATING EKOPEL


SOLID FUEL HOT WATER BOILER

GENERAL INFORMATION AND MATERIAL QUALITY • With the insulation we have made in our boilers, we
• Our company is controlled and audited by EKOTEK, Brand minimize heat losses and provide fuel savings.
registered and ISO 9001:2015 quality management system. • Although it is optional in our boilers, antifreeze can be used
Our products are TSE CERTIFIED products. against the risk of freezing in the installation.
• Welding processes are carried out by certified welders in • Thanks to its 3-pass design that can fit into the narrowest
accordance with approved WPS and WPQRs. spaces, it distributes the heat obtained equally to all surfaces,
• The products used in production are all certified materials. providing maximum heat transfer and fuel savings.
• Our boilers produced in TS EN 497 standards are certified • Pellet, hazelnut shell, lignite coal, etc. It can burn granular
with 97/23/AT Pressure Equipment Regulation module H Full fuels and provides high efficiency.
Quality Assurance. • Our boilers do not cause noise pollution with their silent
• Our products are manufactured using S235 JR quality sheet operation.
metal. • More heating is provided with less fuel.
• Our products are manufactured using boiler pipes made of • By keeping the water temperature constant with the digital
P235GH and higher quality steel in accordance with TS EN control panel, fuel savings are maximized.
10217-2 norm. • Our boilers are designed for minimum 4.500 kcal/h (flame
temperature 1200 C°) fuel. Please contact our company to
burn lower calorie fuel.
K
A

B
L C
BOILER FLANGES FUEL TANK APPROXIMATE
PROPERTIES
INSULATION
OPERATING
PRESSURE
DISCHARGE

CAPACITY
WEIGHT
VOLUME
WATER

SAFETY
OUTPUT

MODEL CAPACITY
WATER

WATER

Dimensions
INLET

COAL OLIVE
POMANCE

BİRİM KCAL/H KW MW A B C H K L LT DN DN INCH INCH KG KG BAR MM KG


EKOPEL 3G YS 80 80.000 93 0,09 2350 760 1150 1350 220 1200 230 2'' 2'' 1 1 150 125 3 100 763
EKOPEL 3G YS 100 100.000 116 0,12 2650 760 1150 1350 220 1500 255 2'' 2'' 1 1 150 125 3 100 775
EKOPEL 3G YS 130 130.000 151 0,15 2850 870 1250 1550 220 1600 315 50 50 1 1/4 1 150 125 3 100 900
EKOPEL 3G YS 150 150.000 174 0,17 3000 870 1250 1550 220 1750 360 50 50 1 1/4 1 150 125 3 100 1200

EKOPEL 3G YS 160 160.000 186 0,19 3000 940 1250 1550 220 1750 380 65 65 1 1/4 1 200 175 3 100 1230
EKOPEL 3G YS 200 200.000 233 0,23 3200 1040 1450 1750 270 1750 485 65 65 1 1/4 1 200 175 3 100 1606
EKOPEL 3G YS 250 250.000 291 0,29 3600 1160 1600 1800 320 2000 610 80 80 1 1/2 1 200 175 3 100 1800
EKOPEL 3G YS 300 300.000 349 0,35 3750 1160 1650 1850 400 2100 650 80 80 1 1/2 1 200 175 3 100 2110
EKOPEL 3G YS 350 350.000 407 0,41 4000 1300 1750 2060 400 2250 910 80 80 1 1/2 1 200 175 3 100 2550
EKOPEL 3G YS 400 400.000 465 0,47 4100 1300 1750 2060 400 2350 960 80 80 1 1/2 1 200 175 3 100 3100
EKOPEL 3G YS 500 500.000 581 0,58 4250 1520 1900 2205 400 2350 1155 100 100 2 1 200 175 4 100 4360
EKOPEL 3G YS 600 600.000 698 0,70 4500 1620 1900 2270 400 2800 1205 100 100 2 1 200 175 4 100 4650
EKOPEL 3G YS 700** 700.000 814 0,81 4900 1620 1900 2270 450 3000 1465 100 100 2 1 400 350 4 100 5700
EKOPEL 3G YS 800** 800.000 930 0,93 5000 1740 2000 2300 450 3000 1960 100 100 2 1 400 350 4 100 6560
EKOPEL 3G YS 900** 900.000 1.047 1,05 5200 1860 2000 2500 450 3200 2210 100 100 2 1 400 350 4 100 7100

EKOPEL 3G YS 1000** 1.000.000 1.163 1,16 5500 1860 2000 2500 500 3500 2955 125 125 2 2 400 350 5 100 7950
EKOPEL 3G YS 1250** 1.250.000 1.453 1,45 6000 1860 2000 2500 500 4000 3160 125 125 2 2 400 350 5 100 8750
EKOPEL 3G YS 1500** 1.500.000 1.744 1,74 6550 1900 2050 2600 550 4500 3280 125 125 2 1/2 2 400 350 5 100 9950

EKOTEK HEAT TECHNOLOGIES HAVE THE RIGHT TO MAKE


CHANGES IN STANDARDS, DESIGNS, VS, DIMENSIONS, WEIGHTS AND MODELS WITHOUT NOTICE.

NOTE: The recommended chimney diameter is calculated as an average of 400 m altitude.


The diameter of the chimney is the minimum size and may vary.

Contact : +90 256 231 15 95 59


FIERY SERIES
25.000 KCAL/H-60.000 KCAL/H heat capacity

INDIVIDUAL HEATING COUNTER-


PRESSURIZED LIQUID/GAS FUEL
HOT WATER BOILER

GENERAL INFORMATION AND MATERIAL QUALITY • Get support from engineering companies for central system
• Our company is controlled and audited by EKOTEK, Brand gas opening works. For the burner pe max: 300 or pe 21 mbar
registered and ISO 9001:2015 quality management system. gas line according to the burner gas pressure, please get
Our products are TSE CERTIFIED products. information from our company for the gas line.
• Welding processes are carried out by certified welders in • Do not forget to have a ce and tse certified chimney made
accordance with approved WPS and WPQRs. for natural gas. Do not forget to get a chimney offer suitable
• The products used in production are all certified materials. for natural gas from our company.
• Our boilers produced in TS EN 497 standards are certified • It has the flexibility to work in harmony with different
with 97/23/AT Pressure Equipment Regulation module H Full combustion systems.
Quality Assurance. • They are boilers that provide high efficiency and can burn
• Our products are manufactured using S235 JR quality sheet LIQUID and GAS fuels that produce hot water for ships,
metal. construction sites and flats that can fit into the narrowest
• Our products are manufactured using boiler pipes made of spaces with their small design.
P235GH and higher quality steel in accordance with TS EN • These are our boilers that provide ECONOMIC ease of use
10217-2 norm. with their high efficiency design and low fuel consumption.
• With the insulation we have made in our boilers, we • With the back pressure combustion system, the flame
minimize heat losses and provide fuel savings. returns within the same cell, the gases and half-burned fuel
• Although it is optional in our boilers, antifreeze can be used particles that encounter the burner flame for the second time
against the risk of freezing in the installation. are converted into energy by burning again and the fuel is
completely burned.

BOILER FLANGES
APPROXIMATE
PROPERTIES
INSULATION
OPERATING
PRESSURE

WEIGHT
VOLUME

DISCHARGE
WATER

OUTPUT

SAFETY
WATER

WATER

MODEL CAPACITY
INLET

Dimensions

BİRİM KCAL/H KW A B C D H L K LT INCH INCH INCH INCH BAR MM KG


FIERY25 25.000 29 1150 560 250 400 550 500 120 115 1 1/4 1 1/4 3/4 1/2 2 50 215

FIERY 40 40.000 46 1200 600 250 450 550 720 120 130 1 1/4 1 1/4 3/4 1/2 2 50 280

FIERY 60 60.000 69 1740 650 350 540 550 850 150 165 1 1/2 1 1/2 3/4 1/2 2 50 345

EKOTEK HEAT TECHNOLOGIES HAVE THE RIGHT TO MAKE


CHANGES IN STANDARDS, DESIGNS, VS, DIMENSIONS, WEIGHTS AND MODELS WITHOUT NOTICE.

NOTE: The recommended chimney diameter is calculated as an average of 400 m altitude.


The diameter of the chimney is the minimum size and may vary.

60 www.ekotekkazan.com
ATOM SERIES
80.000 KCAL/H-2.500.000 KCAL/H heat capacity

CENTRAL HEATING AGAINST


PRESSURE LIQUID/GAS FUEL
HOT WATER BOILER

GENERAL INFORMATION AND MATERIAL QUALITY


• Our company is controlled and audited by EKOTEK, Brand • Although it is optional in our boilers, antifreeze can be used
registered and ISO 9001:2015 quality management system. against the risk of freezing in the installation.
Our products are TSE CERTIFIED products. • Get support from engineering companies for central system
• Welding processes are carried out by certified welders in gas opening works. For the burner pe max: 300 or pe 21 mbar
accordance with approved WPS and WPQRs. gas line according to the burner gas pressure, please get
• The products used in production are all certified materials. information from our company for the gas line.
• Our boilers produced in TS EN 497 standards are certified • Do not forget to have a ce and tse certified chimney made
with 97/23/AT Pressure Equipment Regulation module H Full for natural gas. Do not forget to get a chimney offer suitable
Quality Assurance. for natural gas from our company.
• Our products are manufactured using S235 JR quality sheet • These are our boilers that provide ECONOMIC ease of use
metal. with their high efficiency design and low fuel consumption.
• Our products are manufactured using boiler pipes made of • With the back pressure combustion system, the flame
P235GH and higher quality steel in accordance with TS EN returns within the same cell, the gases and half-burned fuel
10217-2 norm. particles that encounter the burner flame for the second time
• With the insulation we have made in our boilers, we are converted into energy by burning again and the fuel is
minimize heat losses and provide fuel savings. completely burned.

K
H

C L B
BOILER FLANGES
APPROXIMATE
OPERATING
PRESSURE

PRESSURE

PROPERTIES
COUNTER-

INSULATION
DISCHARGE

WEIGHT
VOLUME
WATER

SAFETY
OUTPUT
WATER

WATER

MODEL CAPACITY Dimensions


INLET

BİRİM KCAL/H KW MW A B C H K L LT DN DN INCH INCH BAR MBAR MM KG


ATOM 80 80.000 93 0,09 1450 585 550 775 150 900 230 2'' 2'' 1 1 3 0,7 100 275
ATOM 100 100.000 116 0,12 1450 640 550 820 200 900 255 2'' 2'' 1 1 3 0,7 100 350

ATOM 130 130.000 151 0,15 1650 640 550 820 200 950 315 50 50 1 1/4 1 3 1 100 400

ATOM 160 160.000 186 0,19 1750 720 550 875 200 1050 360 65 65 1 1/4 1 3 1,3 100 500

ATOM 200 200.000 233 0,23 1750 810 550 960 250 1050 375 65 65 1 1/4 1 3 1,5 100 600

ATOM 225 225.000 262 0,26 1800 840 550 1000 250 1100 425 65 65 1 1/4 1 3 1,6 100 700
ATOM 250 250.000 291 0,29 1950 850 550 1100 250 1200 475 80 80 1 1/2 1 3 1,8 100 850

ATOM 300 300.000 349 0,35 2200 850 550 1100 300 1450 600 80 80 1 1/2 1 3 1,8 100 950
ATOM 400 400.000 465 0,47 2350 950 550 1160 300 1500 675 80 80 1 1/2 1 3 1,8 100 1050

ATOM 450 450.000 523 0,52 2500 1000 650 1240 350 1575 753 80 80 1 1/2 1 4 1,8 100 1100

ATOM 500 500.000 581 0,58 2600 1000 650 1240 350 1650 815 100 100 2 1 4 1,8 100 1200

ATOM 600 600.000 698 0,70 2650 1100 650 1350 350 1650 890 100 100 2 1 4 2 100 1280
ATOM 700 700.000 814 0,81 2900 1100 650 1350 350 1850 960 100 100 2 1 4 2,3 100 1320

ATOM 800 800.000 930 0,93 3270 1250 700 1500 400 1900 1060 100 100 2 1 4 2,6 100 1430
ATOM 900 900.000 1.047 1,05 3550 1250 700 1500 400 2100 1125 100 100 2 1 4 2,8 100 1650

ATOM 1000 1.000.000 1.163 1,16 3700 1350 700 1650 450 2300 1355 125 125 3 1 5 3 100 1780

ATOM 1250 1.250.000 1.453 1,45 3950 1400 750 1700 500 2500 1550 125 125 3 1 5 3,7 100 2150

ATOM 1500 1.500.000 1.744 1,74 3950 1550 750 1850 550 2500 1940 125 125 3 1 5 3,9 100 2560

ATOM 2000 2.000.000 2.326 2,33 4300 1650 750 1900 550 2800 2200 150 150 4 1 8 4,8 100 3100
ATOM 2500 2.500.000 2.907 2,91 4500 1700 750 2000 600 2950 2945 150 150 4 1 8 5 100 3550

EKOTEK HEAT TECHNOLOGIES HAVE THE RIGHT TO MAKE


CHANGES IN STANDARDS, DESIGNS, VS, DIMENSIONS, WEIGHTS AND MODELS WITHOUT NOTICE.
NOTE: The recommended chimney diameter is calculated as an average of 400 m altitude.
The diameter of the chimney is the minimum size and may vary.

Contact : +90 256 231 15 95 61


BURNING SERIES
100.000 KCAL/H-20.000.000 KCAL/H heat capacity

SCOTCH TYPE LIQUID / GAS FUEL


HOT WATER BOILER

GENERAL INFORMATION AND MATERIAL QUALITY • Get support from engineering companies for central system
• Our company is controlled and audited by EKOTEK, gas opening works. Pe max:300 or pe 21 mbar gas line to the
Brand-registered, ISO 9001:2015 quality management system. burner According to the burner gas pressure For the gas line
Our products are TSE CERTIFIED products. Get information from our company.
• Welding processes are carried out by certified welders in • Do not forget to have a ce and tse certified chimney made
accordance with approved WPS and WPQRs. for natural gas. Do not forget to get a chimney offer suitable
• The products used in production are all certified materials. for natural gas from our company.
• Our boilers produced in TS EN 497 standards are certified • Thanks to its Scotch Type Three-pass design, it distributes
with 97/23/AT Pressure Equipment Regulation module H Full the heat obtained equally to all surfaces, ensuring maximum
Quality Assurance. heat transfer and
• Our products are manufactured using S235 JR quality sheet saves fuel.
metal. • These are our boilers that provide ECONOMIC ease of use
• Our products are manufactured using boiler pipes made of with their high efficiency design and low fuel consumption.
P235GH and higher quality steel in accordance with TS EN • With the insulation we have made in our boilers, we
10217-2 norm. minimize heat losses and provide fuel savings.
BOILER FLANGES

APPROXIMATE
OPERATING
PRESSURE

PRESSURE

PROPERTIES
COUNTER-

INSULATION
DISCHARGE

WEIGHT
VOLUME
WATER

SAFETY
OUTPUT
WATER

WATER

MODEL CAPACITY Dimensions


INLET

BİRİM KCAL/H KW MW A B C D H K L LT DN DN INCH INCH BAR MBAR MM KG


BURNING 100 100.000 116 0,12 1450 600 550 700 1100 150 1070 260 2'' 2'' 1 1 3 0,8 100 765

BURNING 130 130.000 151 0,15 1590 700 550 800 1150 170 1200 275 2'' 2'' 1 1 3 0,9 100 860

BURNING 150 150.000 174 0,17 1700 700 550 800 1150 170 1300 320 50 50 1 1/4 1 3 1 100 900

BURNING 160 160.000 186 0,19 1800 750 550 850 1250 200 1350 380 65 65 1 1/4 1 3 1,5 100 1200

BURNING 200 200.000 233 0,23 1900 750 550 850 1250 200 1420 420 65 65 1 1/4 1 3 1,5 100 1290

BURNING 250 250.000 1900 820 550 920 1370 200 1420 515 65 65 1 1/4 1 3 2 100 1450
291 0,29
H
BURNING 300 300.000 349 0,35 2120 1000 600 1100 1500 200 1550 675 80 80 1 1/2 1 3 2,5 100 1760

BURNING 350 350.000 407 0,41 2400 1000 600 1100 1500 250 1800 720 80 80 1 1/2 1 3 3 100 1980

BURNING 400 400.000 465 0,47 2600 1000 600 1100 1550 250 1900 970 80 80 1 1/2 1 3 3,5 100 2370

BURNING 450 450.000 523 0,52 2600 1100 700 1200 1650 250 1900 1050 80 80 1 1/2 1 3 4 100 2670

BURNING 500 500.000 581 0,58 2750 1300 700 1400 1800 300 1950 1230 100 100 2 1 4 4,3 100 3190

BURNING 600 600.000 698 0,70 2800 1300 700 1400 1800 300 2050 1320 100 100 2 1 4 4,7 100 3750
B
BURNING 700 700.000 814 0,81 2950 1300 700 1400 1850 350 2200 1585 100 100 2 1 4 5 100 4050

BURNING 800 800.000 930 0,93 3100 1420 700 1520 2000 350 2250 2105 100 100 2 1 4 5 100 4300 A
BURNING 900 900.000 1.047 1,05 3250 1550 700 1650 2150 400 2400 2350 100 100 2 1 4 5 100 4700

BURNING 1000 1.000.000 1.163 1,16 3550 1550 700 1650 2150 450 2700 3100 125 125 3 2 5 5,4 100 4950

BURNING 1250 1.250.000 3550 1600 750 1700 2200 500 2700 3290 125 125 3 2 5 6 100 5100
K
1.453 1,45
BURNING 1500 1.500.000 1.744 1,74 3750 1620 750 1720 2250 550 2900 3450 125 125 3 2 5 6 100 5300
D
BURNING 1750 1.750.000 2.035 2,03 3750 1750 750 1850 2380 550 2900 4750 150 150 4 2 5 6,5 100 5750

BURNING 2000 2.000.000 2.326 2,33 4000 1800 750 1900 2450 600 3150 6120 150 150 4 2 5 6,5 100 6070

BURNING 2500 2.500.000 2.907 2,91 4150 1850 800 1950 2500 650 3250 7040 150 150 4 2 6 6,5 100 7400
C L D1
BURNING 3000 3.000.000 3.488 3,49 4550 1960 800 2060 2610 700 3650 8450 150 150 4 2 6 7 100 8350

BURNING 3500 3.500.000 4.070 4,07 4950 2050 800 2150 2750 750 4000 10200 200 200 4 2 6 7 100 9100

BURNING 4000 4.000.000 4.651 4,65 4950 2150 1000 2260 2900 800 4000 11850 200 200 4 2 6 7,5 100 10900

BURNING 4500 4.500.000 5.233 5,23 5750 2250 1000 2350 3000 850 4500 13500 200 200 4 2 6 8 100 12650

BURNING 5000 5.000.000 5232 5,23 5750 2350 1000 2500 3100 900 4500 14250 200 200 4 2 6 8 100 14750

BURNING 6000 6.000.000 6.977 6,98 5750 2400 1000 2500 3200 1000 4500 15600 200 200 4 2 6 8 100 16250

BURNING 7000 7.000.000 8.140 8,14 6150 2550 1000 2650 3350 1100 4900 18500 200 200 4 2 6 9 100 18700

BURNING 8000 8.000.000 9.302 9,30 7000 2900 1250 3000 3700 1200 5750 19400 200 200 4 2 6 9 100 20350

BURNING 9000 9.000.000 10.465 10,47 7650 2950 1250 3050 3750 1300 6250 20750 250 250 4 2 6 9 100 21900

BURNING 10000 10.000.000 11.628 11,63 8200 3100 1250 3000 3650 1400 6750 21900 250 250 4 2 6 9,5 100 24350

BURNING 17000 17.000.000 19.767 19,77 8200 3350 1250 3300 3950 1500 6800 25750 250 250 4 2 6 9,5 100 27750

BURNING 19000 19.000.000 22.093 22,09 8250 3750 1300 3700 4350 1600 6650 31000 250 250 4 2 6 9,5 100 29500

BURNING 20000 20.000.000 23.256 23,26 8300 3800 1300 3750 4400 1650 6950 33350 250 250 4 2 6 9,5 100 36000

EKOTEK HEAT TECHNOLOGIES HAVE THE RIGHT TO MAKE


CHANGES IN STANDARDS, DESIGNS, VS, DIMENSIONS, WEIGHTS AND MODELS WITHOUT NOTICE.
NOTE: The recommended chimney diameter is calculated as an average of 400 m altitude.
The diameter of the chimney is the minimum size and may vary.
62
SINGLE SERPENTINE
HOT WATER STORAGE
TANK

GENERAL INFORMATION AND MATERIAL QUALITY


• Our company is controlled and audited by EKOTEK, Brand • It can be used with natural circulation or circulation pump.
registered and ISO 9001:2015 quality management system. • It can be supplemented with an additional electric heater.
• Welding processes are carried out by certified welders in • The inner body of the boiler is manufactured with epoxy
accordance with approved WPS and WPQRs. paint.
• The products used in production are all certified materials. • The heat of the heating fluid is transferred to the domestic
• Our products have been produced in accordance with the water by a serpentine with a large cross-section and large
2014/68/EU Pressure Vessels directive and have a CE heat transfer surface area.
certificate. • It is suitable for many places that need hot water such as
• Our products are manufactured according to EN288, apartments, hospitals, schools, villas and hotels.
EN287-1 using S235 JR quality sheet metal. • It has ease of maintenance and use.
• Single serpentine boilers provide both economical and • Optionally, it can be manufactured as vertical and horizontal
hygienic domestic hot water with the heat energy it receives type.
from a single heat source (hot water boiler, steam boiler,
solar energy panels, heat pump, geothermal energy etc.).

H B

TANK FLANGES

APPROXIMATE
OPERATING
PRESSURE

PROPERTIES
INSULATION

WEIGHT
HEATING

HEATING

USE USE
OUTLET
WATER

WATER
INLET

MODEL CAPACITY Dimensions WATER WATER DISCHARGE MANOMETER THERMOMETER


INLET OUTPUT

BİRİM M³ A B H L Rø INCH INCH INCH INCH INCH INCH INCH BAR MM KG


EKO BOYLER 100 0,1 450 650 900 750 250 1 1 3/4 3/4 1 1/2 1/2 6 - 10 100 120
EKO BOYLER 150 0,15 450 650 900 975 250 1 1 3/4 3/4 1 1/2 1/2 6 - 10 100 135

EKO BOYLER 200 0,2 450 650 900 1250 250 1 1 3/4 3/4 1 1/2 1/2 6 - 10 100 155
EKO BOYLER 300 0,3 590 790 1040 1300 300 1 1/4 1 1/4 1 1 1 1/2 1/2 6 - 10 100 210

EKO BOYLER 400 0,4 590 790 1040 1450 300 1 1/4 1 1/4 1 1 1 1/2 1/2 6 - 10 100 275
EKO BOYLER 500 0,5 590 790 1040 1850 300 1 1/4 1 1/4 1 1 1 1/2 1/2 6 - 10 100 310
EKO BOYLER 600 0,6 590 790 1040 2150 300 1 1/4 1 1/4 1 1 1 1/2 1/2 6 - 10 100 350

EKO BOYLER 750 0,75 675 875 1125 2250 300 1 1/4 1 1/4 1 1/4 1 1/4 1 1/2 1/2 6 - 10 100 410
EKO BOYLER 1000 1 900 1100 1350 2100 400 1 1/4 1 1/4 1 1/4 1 1/4 1 1/2 1/2 6 - 10 100 570

EKO BOYLER 1250 1,25 1000 1200 1450 2150 400 1 1/2 1 1/2 1 1/4 1 1/4 1 1/2 1/2 6 - 10 100 650
EKO BOYLER 1500 1,5 1000 1200 1450 2350 400 1 1/2 1 1/2 1 1/4 1 1/4 1 1/2 1/2 6 - 10 100 790
EKO BOYLER 2000 2 1150 1350 1600 2350 500 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1/2 6 - 10 100 850

EKO BOYLER 2500 2,5 1300 1500 1750 2250 500 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1/2 6 - 10 100 1400
EKO BOYLER 3000 3 1300 1500 1750 2600 500 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1/2 6 - 10 100 1575

EKO BOYLER 3500 3,5 1350 1550 1800 2950 500 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1/2 6 - 10 100 1700
EKO BOYLER 4000 4 1450 1650 1900 3100 500 1 1/2 1 1/2 2 2 1 1/2 1/2 6 - 10 100 1800
EKO BOYLER 5000 5 1450 1650 1900 3750 500 1 1/2 1 1/2 2 2 1 1/2 1/2 6 - 10 100 1950

EKO BOYLER 6000 6 1450 1650 1900 4000 500 2 2 2 2 1 1/2 1/2 6 - 10 100 2100
EKO BOYLER 7000 7 1550 1750 2100 4000 600 2 2 2 2 1 1/2 1/2 6 - 10 100 2215

EKO BOYLER 8000 8 1550 1750 2100 4250 600 2 2 2 1/2 2 1/2 1 1/2 1/2 6 - 10 100 2345
EKO BOYLER 9000 9 1650 1850 2200 4250 600 2 2 2 1/2 2 1/2 1 1/2 1/2 6 - 10 100 2475
EKO BOYLER 10000 10 1800 2000 2350 4400 600 2 2 2 1/2 2 1/2 1 1/2 1/2 6 - 10 100 2605

EKOTEK HEAT TECHNOLOGIES HAVE THE RIGHT TO MAKE


CHANGES IN STANDARDS, DESIGNS, VS, DIMENSIONS, WEIGHTS AND MODELS WITHOUT NOTICE.

Contact : +90 256 231 15 95 63


DOUBLE SERPENTINE
HOT WATER
STORAGE TANK

GENERAL INFORMATION AND MATERIAL QUALITY


• Our company, EKOTEK, is brand registered and controlled
and audited by the ISO 9001:2015 quality management
system.
• Welding processes are carried out by certified welders in • It can be used with natural circulation or circulation pump.
accordance with approved WPS and WPQRs. • It can be supplemented with an additional electric heater.
• The products used in production are all certified materials. • The inner body of the boiler is manufactured with epoxy
• Our products are manufactured according to EN288, paint.
EN287-1 using S235 JR quality sheet metal. • The heat of the heating fluid is transferred to the domestic
• Double serpentine boilers come from two different heat water by a serpentine with a large cross-section and large
sources (hot water boiler, steam boiler, solar panels, heat heat transfer surface area.
pump, • It is suitable for many places that need hot water such as
geothermal energy etc.) provides both economical and apartments, hospitals, schools, villas and hotels.
hygienic domestic hot water supply with the heat energy it • It has ease of maintenance and use.
receives. • Optionally, it can be manufactured as vertical and horizontal
type.

H B

A
TANK FLANGES

APPROXIMATE
OPERATING
PRESSURE

PROPERTIES
INSULATION

WEIGHT
HEATING

HEATING

USE USE
OUTLET
WATER

WATER

MODEL
INLET

CAPACITY Dimensions WATER WATER DISCHARGE MANOMETER THERMOMETER


INLET OUTPUT

BİRİM M³ A B H L Rø INCH INCH INCH INCH INCH INCH INCH BAR MM KG


EKO BOYLER 100 0,1 450 650 900 750 250 1 1 3/4 3/4 1 1/2 1/2 6 - 10 100 150
EKO BOYLER 150 0,15 450 650 900 975 250 1 1 3/4 3/4 1 1/2 1/2 6 - 10 100 170

EKO BOYLER 200 0,2 450 650 900 1250 250 1 1 3/4 3/4 1 1/2 1/2 6 - 10 100 210
EKO BOYLER 300 0,3 590 790 1040 1300 300 1 1/4 1 1/4 1 1 1 1/2 1/2 6 - 10 100 245

EKO BOYLER 400 0,4 590 790 1040 1450 300 1 1/4 1 1/4 1 1 1 1/2 1/2 6 - 10 100 280

EKO BOYLER 500 0,5 590 790 1040 1850 300 1 1/4 1 1/4 1 1 1 1/2 1/2 6 - 10 100 350

EKO BOYLER 600 0,6 590 790 1040 2150 300 1 1/4 1 1/4 1 1 1 1/2 1/2 6 - 10 100 410

EKO BOYLER 750 0,75 675 875 1125 2250 300 1 1/4 1 1/4 1 1/4 1 1/4 1 1/2 1/2 6 - 10 100 590

EKO BOYLER 1000 1 900 1100 1350 2100 400 1 1/4 1 1/4 1 1/4 1 1/4 1 1/2 1/2 6 - 10 100 670

EKO BOYLER 1250 1,25 1000 1200 1450 2150 400 1 1/2 1 1/2 1 1/4 1 1/4 1 1/2 1/2 6 - 10 100 720

EKO BOYLER 1500 1,5 1000 1200 1450 2350 400 1 1/2 1 1/2 1 1/4 1 1/4 1 1/2 1/2 6 - 10 100 820

EKO BOYLER 2000 2 1150 1350 1600 2350 500 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1/2 6 - 10 100 1320

EKO BOYLER 2500 2,5 1300 1500 1750 2250 500 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1/2 6 - 10 100 1475

EKO BOYLER 3000 3 1300 1500 1750 2600 500 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1/2 6 - 10 100 1610
EKO BOYLER 3500 3,5 1350 1550 1800 2950 500 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1/2 6 - 10 100 1730

EKO BOYLER 4000 4 1450 1650 1900 3100 500 1 1/2 1 1/2 2 2 1 1/2 1/2 6 - 10 100 1875
EKO BOYLER 5000 5 1450 1650 1900 3750 500 1 1/2 1 1/2 2 2 1 1/2 1/2 6 - 10 100 2350

EKO BOYLER 6000 6 1450 1650 1900 4000 500 2 2 2 2 1 1/2 1/2 6 - 10 100 2520
EKO BOYLER 7000 7 1550 1750 2100 4000 600 2 2 2 2 1 1/2 1/2 6 - 10 100 2630

EKO BOYLER 8000 8 1550 1750 2100 4250 600 2 2 2 1/2 2 1/2 1 1/2 1/2 6 - 10 100 2710

EKO BOYLER 9000 9 1650 1850 2200 4250 600 2 2 2 1/2 2 1/2 1 1/2 1/2 6 - 10 100 2850

EKO BOYLER 10000 10 1800 2000 2350 4400 600 2 2 2 1/2 2 1/2 1 1/2 1/2 6 - 10 100 2940

EKOTEK HEAT TECHNOLOGIES HAVE THE RIGHT TO MAKE


CHANGES IN STANDARDS, DESIGNS, VS, DIMENSIONS, WEIGHTS AND MODELS WITHOUT NOTICE.

64 www.ekotekkazan.com
JACKETED HOT
WATER STORAGE TANK

GENERAL INFORMATION AND MATERIAL QUALITY


• Our company, EKOTEK, is brand registered and controlled • It can be used with natural circulation or circulation pump.
and audited by the ISO 9001:2015 quality management • It can be supplemented with an additional electric heater.
system. • The inner body of the boiler is manufactured with epoxy
• Welding processes are carried out by certified welders in paint.
accordance with approved WPS and WPQRs. • The heat of the heating fluid is transferred to the domestic
• The products used in production are all certified materials. water by a serpentine with a large cross-section and large
• Our products are manufactured according to EN288, heat transfer surface area.
EN287-1 using S235 JR quality sheet metal. • It is suitable for many places that need hot water such as
• Double serpentine boilers come from two different heat apartments, hospitals, schools, villas and hotels.
sources (hot water boiler, steam boiler, solar panels, heat • It has ease of maintenance and use.
pump, • Optionally, it can be manufactured as vertical and horizontal
geothermal energy etc.) provides both economical and type.
hygienic domestic hot water supply with the heat energy it
receives.

H
B

A
TANK FLANGES

APPROXIMATE
OPERATING
PRESSURE

PROPERTIES
INSULATION

WEIGHT
HEATING

HEATING

USE USE
OUTLET
WATER

WATER
INLET

MODEL CAPACITY Dimensions WATER WATER DISCHARGE MANOMETER THERMOMETER


INLET OUTPUT

BİRİM M³ A B H L Rø INCH INCH INCH INCH INCH INCH INCH BAR MM KG


EKO BOYLER 100 0,1 550 750 970 900 250 1 1 3/4 3/4 1 1/2 1/2 6 - 10 100 105

EKO BOYLER 150 0,15 550 750 970 1050 250 1 1 3/4 3/4 1 1/2 1/2 6 - 10 100 120

EKO BOYLER 200 0,2 550 750 970 1350 250 1 1 3/4 3/4 1 1/2 1/2 6 - 10 100 150
EKO BOYLER 300 0,3 690 890 1110 1400 300 1 1/4 1 1/4 1 1 1 1/2 1/2 6 - 10 100 195
EKO BOYLER 400 0,4 690 890 1110 1550 300 1 1/4 1 1/4 1 1 1 1/2 1/2 6 - 10 100 210

EKO BOYLER 500 0,5 690 890 1110 1950 300 1 1/4 1 1/4 1 1 1 1/2 1/2 6 - 10 100 290

EKO BOYLER 600 0,6 690 890 1110 2250 300 1 1/4 1 1/4 1 1 1 1/2 1/2 6 - 10 100 365
EKO BOYLER 750 0,75 800 1000 1200 2350 300 1 1/4 1 1/4 1 1/4 1 1/4 1 1/2 1/2 6 - 10 100 510

EKO BOYLER 1000 1 1050 1250 1450 2200 400 1 1/4 1 1/4 1 1/4 1 1/4 1 1/2 1/2 6 - 10 100 630

EKO BOYLER 1250 1,25 1150 1350 1550 2250 400 1 1/2 1 1/2 1 1/4 1 1/4 1 1/2 1/2 6 - 10 100 690
EKO BOYLER 1500 1,5 1150 1350 1550 2450 400 1 1/2 1 1/2 1 1/4 1 1/4 1 1/2 1/2 6 - 10 100 780
EKO BOYLER 2000 2 1300 1500 1700 2450 500 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1/2 6 - 10 100 985

EKO BOYLER 2500 2,5 1500 1700 1850 2350 500 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1/2 6 - 10 100 1190

EKO BOYLER 3000 3 1600 1800 1850 2700 500 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1/2 6 - 10 100 1285
EKO BOYLER 3500 3,5 1600 1800 1950 3050 500 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1/2 6 - 10 100 1410

EKO BOYLER 4000 4 1700 1900 2050 3200 500 1 1/2 1 1/2 2 2 1 1/2 1/2 6 - 10 100 1670
EKO BOYLER 5000 5 1700 1900 2050 3850 500 1 1/2 1 1/2 2 2 1 1/2 1/2 6 - 10 100 2050

EKO BOYLER 6000 6 1700 1900 2050 4120 500 2 2 2 2 1 1/2 1/2 6 - 10 100 2190
EKO BOYLER 7000 7 1850 2050 2250 4370 600 2 2 2 2 1 1/2 1/2 6 - 10 100 2320

EKO BOYLER 8000 8 1850 2050 2250 4370 600 2 2 2 1/2 2 1/2 1 1/2 1/2 6 - 10 100 2480

EKO BOYLER 9000 9 1950 2050 2350 4370 600 2 2 2 1/2 2 1/2 1 1/2 1/2 6 - 10 100 2650
EKO BOYLER 10000 10 2050 2250 2500 4550 600 2 2 2 1/2 2 1/2 1 1/2 1/2 6 - 10 100 2770

EKOTEK HEAT TECHNOLOGIES HAVE THE RIGHT TO MAKE


CHANGES IN STANDARDS, DESIGNS, VS, DIMENSIONS, WEIGHTS AND MODELS WITHOUT NOTICE.

Contact : +90 256 231 15 95 65


SERPENTINE AND
JACKETED HOT
WATER STORAGE TANK

GENERAL INFORMATION AND MATERIAL QUALITY


• Our company, EKOTEK, is brand registered and controlled • It can be used with natural circulation or circulation pump.
and audited by the ISO 9001:2015 quality management • It can be supplemented with an additional electric heater.
system. • The inner body of the boiler is manufactured with epoxy
• Welding processes are carried out by certified welders in paint.
accordance with approved WPS and WPQRs. • The heat of the heating fluid is transferred to the domestic
• The products used in production are all certified materials. water by a serpentine with a large cross-section and large
• Our products are manufactured according to EN288, heat transfer surface area.
EN287-1 using S235 JR quality sheet metal. • It is suitable for many places that need hot water such as
• Double serpentine boilers come from two different heat apartments, hospitals, schools, villas and hotels.
sources (hot water boiler, steam boiler, solar panels, heat • It has ease of maintenance and use.
pump, • Optionally, it can be manufactured as vertical and horizontal
geothermal energy etc.) provides both economical and type.
hygienic domestic hot water supply with the heat energy it
receives.

H B

A
TANK FLANGES

APPROXIMATE
OPERATING
PRESSURE

PROPERTIES
INSULATION

WEIGHT
HEATING

HEATING

USE USE
OUTLET
WATER

WATER

MODEL
INLET

CAPACITY Dimensions WATER WATER DISCHARGE MANOMETER THERMOMETER


INLET OUTPUT

BİRİM M³ A B H L Rø INCH INCH INCH INCH INCH INCH INCH BAR MM KG


EKO BOYLER 100 0,1 550 750 970 900 250 1 1 3/4 3/4 1 1/2 1/2 6 - 10 100 135
EKO BOYLER 150 0,15 550 750 970 1050 250 1 1 3/4 3/4 1 1/2 1/2 6 - 10 100 150

EKO BOYLER 200 0,2 550 750 970 1350 250 1 1 3/4 3/4 1 1/2 1/2 6 - 10 100 180

EKO BOYLER 300 0,3 690 890 1110 1400 300 1 1/4 1 1/4 1 1 1 1/2 1/2 6 - 10 100 220
EKO BOYLER 400 0,4 690 890 1110 1550 300 1 1/4 1 1/4 1 1 1 1/2 1/2 6 - 10 100 275

EKO BOYLER 500 0,5 690 890 1110 1950 300 1 1/4 1 1/4 1 1 1 1/2 1/2 6 - 10 100 330

EKO BOYLER 600 0,6 690 890 1110 2250 300 1 1/4 1 1/4 1 1 1 1/2 1/2 6 - 10 100 375
EKO BOYLER 750 0,75 800 1000 1200 2350 300 1 1/4 1 1/4 1 1/4 1 1/4 1 1/2 1/2 6 - 10 100 495

EKO BOYLER 1000 1 1050 1250 1450 2200 400 1 1/4 1 1/4 1 1/4 1 1/4 1 1/2 1/2 6 - 10 100 620

EKO BOYLER 1250 1,25 1150 1350 1550 2250 400 1 1/2 1 1/2 1 1/4 1 1/4 1 1/2 1/2 6 - 10 100 690
EKO BOYLER 1500 1,5 1150 1350 1550 2450 400 1 1/2 1 1/2 1 1/4 1 1/4 1 1/2 1/2 6 - 10 100 805

EKO BOYLER 2000 2 1300 1500 1700 2450 500 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1/2 6 - 10 100 1085

EKO BOYLER 2500 2,5 1500 1700 1850 2350 500 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1/2 6 - 10 100 1430

EKO BOYLER 3000 3 1600 1800 1850 2700 500 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1/2 6 - 10 100 1585
EKO BOYLER 3500 3,5 1600 1800 1950 3050 500 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1/2 6 - 10 100 1715

EKO BOYLER 4000 4 1700 1900 2050 3200 500 1 1/2 1 1/2 2 2 1 1/2 1/2 6 - 10 100 1850

EKO BOYLER 5000 5 1700 1900 2050 3850 500 1 1/2 1 1/2 2 2 1 1/2 1/2 6 - 10 100 1950

EKO BOYLER 6000 6 1700 1900 2050 4120 500 2 2 2 2 1 1/2 1/2 6 - 10 100 2200
EKO BOYLER 7000 7 1850 2050 2250 4370 600 2 2 2 2 1 1/2 1/2 6 - 10 100 2315

EKO BOYLER 8000 8 1850 2050 2250 4370 600 2 2 2 1/2 2 1/2 1 1/2 1/2 6 - 10 100 2430

EKO BOYLER 9000 9 1950 2050 2350 4370 600 2 2 2 1/2 2 1/2 1 1/2 1/2 6 - 10 100 2560
EKO BOYLER 10000 10 2050 2250 2500 4550 600 2 2 2 1/2 2 1/2 1 1/2 1/2 6 - 10 100 2750

EKOTEK HEAT TECHNOLOGIES HAVE THE RIGHT TO MAKE


CHANGES IN STANDARDS, DESIGNS, VS, DIMENSIONS, WEIGHTS AND MODELS WITHOUT NOTICE.

66 www.ekotekkazan.com
ABOVE GROUND
FUEL TANK

GENERAL INFORMATION AND MATERIAL QUALITY • Fuel Tanks are evaluated in two groups as Underground /
• Our company is controlled and audited by EKOTEK, Brand Aboveground fuel tanks and body thicknesses are
registered and ISO 9001:2015 quality management system. determined by making calculations according to the
• Welding processes are carried out by certified welders in standards according to the volume of the fluid inside.
accordance with approved WPS and WPQRs. • Leakage controls of the fuel tanks are provided by
• The products used in production are all certified materials. performing a Hydrostatic test.
• Our products are produced in accordance with TS EN 12285 • Aboveground fuel tanks heat center fuel needs – These are
– 2 Standard and 2014/68/EU Pressure Vessels directive and the tanks used to store fuel and oil in aboveground conditions
have CE certificate. in cases such as vehicle fuel needs.
• Tanks produced in accordance with TS EN 12285 TS 712 • Underground fuel tanks are painted with fillot paint and
standards are produced from S235 JR sheet and welded. grounded with a magnesium anode rod to prevent static
electricity and corrosion.
• Material dimensions and thicknesses to be used in
underground and aboveground fuel tanks are specified in the
% 100 SAFE , USER-FRIENDLY table in the TS EN 12885 standard.

Our tanks are produced as single and double


walled.
• Above ground fuel tanks, which are produced A
between 1.000L and 100.000L and used for
liquid fuel storage, are produced without
heater according to the type of fuel.
• Offered to insulated and non-insulated
consumers upon request.
H
• Heaters can be connected to our tanks, which
are produced as insulated and non-insulated B
upon request.
• Level indicator is available.
• Ventilation is available. H1
C1 C
D
APPROXIMATE

TANK FLANGES
WEIGHT

MODEL CAPACITY Dimensions FUEL


FILLING AIR OUT MAN HOLE
OUTPUT

BİRİM LT A B B1 C D H K L INCH INCH INCH INCH KG


EKO TS YT 1 93 1450 600 350 550 700 1100 150 1070 2'' 2'' 1 1 765
EKO TS YT 3 116 1590 700 350 550 800 1150 170 1200 2'' 2'' 1 1 860
EKO TS YT 5 151 1700 700 350 550 800 1150 170 1300 50 50 1 1/4 1 900
EKO TS YT 7 174 1800 750 350 550 850 1250 200 1350 65 65 1 1/4 1 1200
EKO TS YT 10 186 1900 750 350 550 850 1250 200 1420 65 65 1 1/4 1 1290
EKO TS YT 13 232 1900 820 350 550 920 1370 200 1420 65 65 1 1/4 1 1606
EKO TS YT 16 290 2120 1000 350 600 1100 1500 200 1550 80 80 1 1/2 1 1800
EKO TS YT 20 348 2400 1000 350 600 1100 1500 250 1800 80 80 1 1/2 1 2110
EKO TS YT 25 407 2600 1000 350 600 1100 1550 250 1900 80 80 1 1/2 1 2550
EKO TS YT 30 465 2600 1100 350 700 1200 1650 250 1900 80 80 1 1/2 1 2850
EKO TS YT 40 523 2750 1300 350 700 1400 1800 300 1950 100 100 2 1 3340
EKO TS YT 50 581 2800 1300 350 700 1400 1800 300 2050 100 100 2 1 4125
EKO TS YT 60 697 2950 1300 350 700 1400 1850 350 2200 100 100 2 1 4550
EKO TS YT 80 814 3100 1420 350 700 1520 2000 350 2250 100 100 2 1 5250
EKO TS YT 100 930 3250 1550 350 700 1650 2150 350 2400 100 100 2 1 5940

EKOTEK HEAT TECHNOLOGIES HAVE THE RIGHT TO MAKE


CHANGES IN STANDARDS, DESIGNS, VS, DIMENSIONS, WEIGHTS AND MODELS WITHOUT NOTICE.

Contact : +90 256 231 15 95 67


STAINLESS TANKS

% 100 SAFE , USER-FRIENDLY

STAINLESS MILK STAINLESS HONEY


PROCESS TANKS MOLASSES TANKS

STAINLESS
OLIVE OIL TANKS

STAINLESS
JUICE TANKS

STAINLESS CHEMICAL
INDUSTRY TANKS
APPROXIMATE
WEIGHT

Dimensions
MODEL CAPACITY
DIAMETER THICKNESS HEIGHT
(MM) (MM) (MM)

BİRİM LT A D H KG
EKO ZT 30 30 330 0,60 500 7,5

EKO ZT 40 40 330 0,60 630 10

EKO ZT 50 50 330 1,00 730 14

EKO ZT 100 100 400 1,00 950 18

EKO ZT 300 300 600 1,20 1250 37

EKO ZT 500 500 750 1,20 1500 46


EKO ZT 1000 1000 900 1,50 1750 67

EKO ZT 1500 1500 1150 1,50 1750 92


EKO ZT 2000 2000 1200 1,50 2100 115

EKO ZT 2500 2500 1300 2,00 2250 157

EKO ZT 3000 3000 1400 2,00 2450 185

EKO ZT 4000 4000 1500 2,00 2600 260

EKO ZT 5000 5000 1750 2,00 2700 335

EKOTEK HEAT TECHNOLOGIES HAVE THE RIGHT TO MAKE


CHANGES IN STANDARDS, DESIGNS, VS, DIMENSIONS,
WEIGHTS AND MODELS WITHOUT NOTICE.

GET INFORMATION FROM OUR COMPANY FOR HEATED TANKS AND HIGHER CAPACITIES.

68 www.ekotekkazan.com
Contact : +90 256 231 15 95 69
References

70 www.ekotekkazan.com
Contact : +90 256 231 15 95 71
References

72 www.ekotekkazan.com
Contact : +90 256 231 15 95 73
References

74 www.ekotekkazan.com
Contact : +90 256 231 15 95 75
76 www.ekotekkazan.com
77
www.ekotekkazan.com
79
76

You might also like