Mic1100 Data-sheet en 03
Mic1100 Data-sheet en 03
CONTROLS for
» for universal cooking and smoking chambers, air conditioned FOODTECHNOLOGY
smoke and maturing chambers …and much more
» OVERVIEW » FEATURES
Brilliant 5” TFT-colour display with touch screen surface in
The process controller MIC1100 resistive touch technology, suitable for industrial
with touch screen surface of 5” TFT- application
Display in resistive touch Anodized aluminum frame, robust stainless steel case
technology, several interfaces, a over, ideally suited for the food industry
housing conforming to industrial highly resistant foil keyboard
standard is designed to be used in Number of programs and steps individually adjusted,
universal cooking and smoking
max.1980 steps total, but max.99 programs and 99 steps
chambers, as well as climatic selectable
smoke and maturing chambers.
Easy, systematical configuration setting
The standard model of the controller Text display can be switched to a different language
has 2 PT100 temperature inputs Most important texts are freely programmable
and 2 transposable inputs Messages as scrolling text display
between PT100 and power 4-
Configuration is protected by codes
20mA/voltage 0-10V or
thermocouples (according to 48 programmable process texts
standard DIN EN 60584). in- and outputs are freely programmable
programmable nominal value limits
PT100 can be connected as two- all nominal values can be displayed during operation and
wire circuit or as three-wire transiently changed
circuit. In three-wire connection a
lead compensation is not option of either relative humidity control or impulse
necessary because it takes place humidifying (interval steaming)
automatically. At 2-wire each control loop can be pre-programmed to be a two-
connection a digital lead point controller, a XP-controller or PID
compensation can be done. Delta-T-cooking
F-value-cooking (FC 70-10), FC 121-10 or individually
The standard version of the
Options for shut down (at end of a step) are: Time limit,
controller has 18 relay outputs (14
exceeding the core temperature value or the humidity
closers, 4 changeover contacts)
value (drying), FC-value or cooling (falling below the core
and 6 digital inputs.
temperature value)
The controller can be expanded
with 2 analogue inputs or 2 analogue outputs (transposable between 0..20mA and Step time up to 99h : 59min or continuous operation
0..10V). Copying, inserting or deleting steps
Step repetition
For communication there are the following serial interfaces: LAN/Ethernet and USB Entering a batch number
Serial Port. Via the USB Serial port you can make a firmware update any time.
Autom. increasing the batch number (+1) at progr. start
Optionally it is possible to equip the controller with up to 8 relays via additional board User rights for administrators
ZR8S or up to 32 digital inputs via additional board ZD32. Up to 72x relays, 48x Actual value alarms (limit value) for temperature and
digital inputs, several analogue in- and outputs with additional modules and an humidity
additional board ZSC (on request) can be allocated as an option. Change-over of the measurement unit °C - °F
Interfaces: LAN (RJ45), USB Serial Port for PC
Optionally it is possible to equip the controller with an additional 8x relay with a
connection. Via the USB Serial port you can make a
ZR8S additional board or with an additional 32x digital inputs with a ZD32
firmware update any time.
additional board. Up to 72x relays, 48x digital inputs, various analogue inputs and
outputs with additional modules and a ZSC additional board (on request) are also Programme that were interrupted through a power cut are
possible. resumed at the point where they stopped when power
restored
To be ideally suited to the required task, each control loop can be pre-programmed to Freely programmable logic with AND/OR linked and timer
be a two-point controller, a XP-controller or PID.
The serial interface enables you to transfer data between the controller MIC
1100 and a PC. Programming of the controller via a PC is easier because of the » additional features for climate control:
aditec service programme. The visualization programme aditec “VisuNet” offers
the possibility of linking the controller to a super-ordinate programme-surveillance and Individual nominal value entry for heating and cooling
of logging temperature and humidity trend, processes etc. It thereby ensures a (min./max. temperatures, humidity)
comprehensive quality control of the products treated in the units in accordance with Gentle motor start-up
HACCP and IFS (ISO 9000). Control of ventilation motor (also infinitely variable) is
Use the remote maintenance system/telecontrol system aditec-control to not only dependent on temperature and/or humidity (intelligent air-
run and monitor the VisuNet programme but to make changes to the system circulation control)
from anywhere you happen to be (Internet).
Automatic shut-down of the cooling function (cooling
aggregate) through user-defined upper limit of actual
aditec Serviceprogramm– free of charge for our customers! and/or nominal values
An easy to use, menu-guided service programme for the basic configuration, which
Regulation with outside air / Enthalpy
means freely programmable relays, processes, programme steps, as well as user
programmes with user-defined labelling of programmes under WIN WIN7 / 8.0 / 8.1 /
Server 2008 / Server 2012.
General data
Material front Aluminium frame, naturally anodized
Housing Robust stainless steel housing (1.4016) DIN standard / German Industry Norms
Cooling Passiv (lüfterlos)
External dimensions: BxHxD with built-in additional board ZR8S or ZD32:
Dimensions BxHxD: 137 x 234 x 120 mm 137 x 234 x 148 mm
Depth with terminals: 131 mm Depth with terminals: 157 mm
Mounting dimens. (cutout): BxH: 92 x 186 mm
Weight 1900 g
Operating temperature -20 to +65°C
Storage temperature -30 to +75°C
Air humidity 35% - 80% (non-condensing)
Atmosphere Non-aggressive gases
IP65 front
Protection class
IP 20 rear side
Electrical data
Power supply 85~260V AC optional 18-36V DC
Residual tipple 5%
Current consumption 105 mA at 230 VAC
Power consumption 24 VA 18 relays are controlled
DIN EN 61010-1
Electrical safety
Overvoltage category III
DIN EN 61326-1 class A for industrial use,
Electromagnetic compatibility
emitted interference, interference immunity for industrial requirements
Battery lifetime (for real-time
8-10 years
clock)
Connection for relay outputs
Removable lift terminals with screws wire min. 0,5 – max. 2,5 mm2
and power supply
min. 0,14 mm2 – max. 1,5 mm2
removable terminals in Push-in-technology
wire cross-section
Connection for dig./analogue (spring terminals)
with 10 mm wire end sleeves
inputs
with 10 mm wire and sleeves
Display
LCD size 5“ (12,7 cm screen size)
Resolution 800 x 480 WVGA
Aspect ratio 16:9
Technology TFT
Colours 16.7 millions
Backlight LED
Luminance 400 cd/m2
Contrast ratio 400:1
Touch Resistive
Serial interfaces
1x USB Host
USB
1x MiniUSB Serial Port
Ethernet/LAN 1x 100Mbit Ethernet/LAN (RJ 45)
communication with additional boards via
CAN (optional) 1x Can Bus (Systembus)
additional board ZSC (on request)
Memory 1x MicroSD Card Slot For MicroSD Card to 32GB
Galvanic isolation
Optional: Power input 18-36VDC -> 2,5kV
Mains input
4 kVAC/1Min Test 1 minute and 1mA max.
85~264VAC/120~370VDC
Sensor inputs (analogue
2 kV
inputs)
Digital inputs 3,75 kV
Analogue outputs 4 kV
Relay outputs 4 kV
Serial interfaces
- LAN 1,5 kV
- USB Host ---
- USB MiniUSB SerialPort ---
8x through holes
D = 5mm for
fastening via M4
threaded bolts
131 mm
234 mm
137 mm
ZSC:
ADDITIONAL BOARD
1x Can Bus (Systembus)
Slot additional
board
Install of ZR8S
ZD32: with MIC 1100
ADDITIONA BOARD
32 DIGITAL INPUTS
ZR8S:
ADDITIONAL BOARD
8 RELAY OUTPUTS