Sr. Item Code Short Description Detailed Description Unit Rate (Rs.

EARTHWORK IN EXCAVATION FOR FOUNDATION OF STRUCTURES IN ALL


TYPES OF SOIL/MURUM INCLUDING SETTING OUT, SHORING, BRACING,
REMOVAL OF STUMPS, AND OTHER DELETERIOUS MATTER, DRESSING OF
SIDES AND BOTTOM. INCLUDING BACKFILLING WITH THE APPROVED
1 3500101904 EXCAVATION IN ALL TYPES OF SOILS MATERIAL FROM EXCAVATED SOIL AND CARTING AWAY UNWANTED CUM 650
EXCESS SOIL/MATERIAL TO THE DESIGNATED PLACES OF
BMC/MMRDA/PWD/MBMC OR PRIVATE PROPERTY OWNER AS PER EMS
NORMS.THE PREMISES TO BE KEPT CLEAN AFTER COMPLETING THE
WORK. ETC COMPLETE.

P&L PCC M15 GRADE CONCRETE P/L IN SITU PLAIN CEMENT CONCRETE
USING TRAP METAL FOR FOUNDATION AND BEDDING INCLUDING USING
GRADED STONES AGGREGATE OF 20MM / 40MM MAX. SIZE INCLUDING
2 3111300024 P&L PCC M15 GRADE CONCRETE CONSOLIDATION, FINISHING, LEVELLING, CURING FOR 7 DAYS, CUM
FORMWORK ETC. COMPLETE ALL AS PER SPECIFICATION A) PCC 1:2:4
USING 40MM MAX. SIZE STONE AGGREGATE ANY LEFT OVER MATERIALS
SHALL BE CLEANED, REMOVED AND DISPOSED AS PER EMS NORMS.
6000.00
P/L IN SITU REINFORCED READYMIX CONCRETE OF M30 GRADE AT ALL
HEIGHTS/ LEVELS WITH APPROVED 20 MM SIZE GRADED STONE
AGGREGATE INCLUDING REQUIRED CENTERING, SHUTTERING,
3 3500101906 RCC M30 CONCRETE CUM
SCAFFOLDING, PUMPING ARRANGEMENT, MECHANICAL VIBRATOR
CONSOLIDATION, FINISHING, DEWATERING, CURING, (EXCLUDING
REINFORCEMENT) ETC COMPLETE
9700.00

PROVIDING & LAYING RUBBLE SOLING WITH GRADED STONE SIZE WITHIN
200 TO 300 MM WITH PREPARATION AND FINISHED TO THICKNESS OF
4 3111300023 Rubble Soiling CUM 1,250
230MM AND FILLING OF INTERSTICES AND COMPACTION. DISPOSAL OF
EXCESS MATERIAL AS DIRECTED BY ENGINEER IN CHARGE

PROVIDING & LAYING INDIAN PATENT STONE (IPS) FLOORING AT ALL


FLOORS AND LEVELS IN 50 MM THICKNESS WITH CEMENT CONCRETE MIX
1:2:4 WITH GRADED STONE AGGREGATE OF 10 MM MAX. SIZE LAID TO
5 3500101907 P&L LAYING 50 MM THICK IPS FLOORING SQM
LEVEL OR SLOPE AS DIRECTED, INCLUDING COMPACTION, FINISHING AND
CURING ETC COMPLETE. SUBSTATION AREA TO BE CLEARED AND
DISPOSED THE EXCESS MATERIAL AS PER MCGM AND EMS NORMS
340.00
P&L BRICK MASONRY 230 THK IN SUBSTRUCTURE IN READY TO PLAST
CEMENT MORTAR 1:4 INCLUDING MIXING MORTAR, LAYING BRICKS,
P&L BRICK MASONRY 230MM THK WITH READY
6 3500101909 SCAFFOLDING, RAKING OUT JOINTS, CURING FOR 7 DAYS ETC. COMPLETE. CUM 6,200
TO PLAST CEMENT MORTAR 1:4
ANY LEFT OVER MATERIALS SHALL BE CLEANED AFTER THE WORK AND
DISPOSED AS PER EMS AND MCGM NORMS.

PROVIDING AND APPLYING SINGLE COAT 12 MM THICK PLASTER IN READY


TO PLAST CEMENT MORTAR 1:4 TO WALLS, BEAMS, CEILING, STAIR,
COLUMN, PARDIS, BENDS, MOULDS, PATTAS, GROOVES, INCLUDING
SCAFFOLDING, CHIPPING, ROUGHING UP THE CONCRETE, CURING &
FINISHING SMOOTH. THE PLASTER SURFACE SHALL BE RUBBED WITH
P&A SINGLE COAT 12MM THK PLASTER IN 'IRON PLATE', TILL THE SURFACE SHOWS CEMENT PASTE IN LINE AND
7 3500101910 SQM
READY TO PLAST CEMENT MORTAR 1:4 LEVEL COMPLETE AS DIRECTED BY THE ENGINEER-IN-CHARGE. CHICKEN
MESH AT JOINTS AS DIRECTED BY EGINEER-IN-CHARGE AND CURING THE
PLASTERED SURFACE FOR 7 DAYS BY SUITABLE MEANS. IF THERE IS ANY
EXCESS OR LOOSE PLASTER ON THE GROUND AND EQUIPMENTS SAME
SHALL BE CLEANED AFTER THE WORK AND DISPOSED AS PER EMS AND
MCGM NORMS.

450.00

P&A DOUBLE COAT 18MM THK SANDFACED CEMENT PLASTER IN READY


TO PLAST CEMENT MORTAR 1:4 , AT ALL HEIGHTS/LEVELS, WITH 1ST COAT
OF THICKNESS 10MM AND 2ND COAT OF 8MM THICKNESS TO BRICK/
CONCRETE/ STONE MASONRY SURFACES, INCLUDING CHICKEN MESH AT
P&A DOUBLE COAT 18MM THK SANDFACED
JOINTS, SCAFFOLDING, KEEPING THE SURFACES OF BASE ALIGNED AND IN
8 3500101911 PLASTER IN READY TO PLAST CEMENT MORTAR SQM 600
LEVEL, INCLUDING WATER DRIP MOULD/ GROOVES/ PATTAS WHEREVER
1:4
NECCESSARY/DIRECTED. CURING THE PLASTERED SURFACE FOR 7 DAYS BY
SUITABLE MEANS. IF THERE IS ANY EXCESS OR LOOSE PLASTER ON THE
GROUND/EQUIPMENTS SAME SHALL BE CLEANED AFTER THE WORK AND
DISPOSED AS PER EMS AND MCGM NORMS.

Reinforcement at All Levels :


Providing and placing TMT/TOR Reinforcement steel bars of FE 500D grade
of TISCO, SAIL OR ISPAT, as per the structural drawing and as approved by
9 3500100815 Reinforcement at All Levels MT 79,000
Engineer In Charge, in reinforced cement concrete work,
including cleaining, straightening cutting bending and placing in position
etc complete

P/A elastomeric/polymeric paint of approved manufacture of approved


colour to the plastered surface including scafolding,
cleaning preparing the surfaces filling up minor cracks with approved
chemical mixed mortar.
10 3450318000 Appln. of Waterproof coating SQM 195
Procedure includes;
1) Surface preparation : Removing all loose dirt,dust laitance
2) Application of Futura Sealer (Acrylic based Sealing/primer coat)
Application of two coat of Futura diluted with not more than 20% of water

Providing and applying 2 coats of synthetic enamel paint over 1 coat of


11 3450310000 Synthetic enamel paint 2 coats (Steel) steel primer on steel surfaces including cleaning and preparing the surface SQM 110
etc.complete

PROVIDING AND FIXING IN POSITION M.S. LOUVERED DOOR / LOUVERS


MADE OF MS FLAT, ANGLE FRAME, CHANNEL, 14 GAUGE CRC SHEET,
WITH DETACHABLE ALUMINIUM JALLI OF OPENING 12 X 12 MM FROM
12 3500101913 P&F M.S.Louvered door SQM 4,000
INSIDE, AS PER APPROVED DRAWING,. WT SHOULD NOT BE LESS THAN 5.2
KG PER SFT. INCLUDING APPROVED HINGE/LOCKING ARRANGEMENT AND
ONE COAT OF APPROVED PRIMER ETC COMPLETE

13 3450636000 Fixing GI spikes Fixing GI spikes. ( Spikes will be supplied by AEML) RMT 450
14 3450432000 M S DECORATIVE GATE M.S Decorative Gate SQM 2,900

STRUCTURAL STEEL WORK PROVIDING, FABRICATING AND PLACING STEEL


EMBEDDED PARTS, ANGLES, CHANNELS, INSERTS ,FOUNDATION BOLTS IN
CONCRETE (INCLUDING TRENCHES ETC.) INCLUDING LABOUR, MATERIAL,
SETTING IN CONCRETE, SCAFFOLDING, HANDLING, WELDING, BOLTING,
15 3111300041 Structural Steel work MT
DRILLING, PROVIDING LUGS, ETC. COMPLETE AS PER DRAWINGS,
SPECIFICATIONS AND DIRECTION OF THE ENGINEER-IN-CHARGE.
SUBSTATION AREA TO BE CLEARED AND DISPOSED THE EXCESS MATERIAL
AS PER MCGM AND EMS NORMS
105000.00

PROVIDING AND FIXING 10 GUAGE DETACHABLE PVC COATED CHAIN LINK


FENCING OF 25MM X25MM OF 2.4METRE HEIGHT INCLUDING STRCTURAL
STEELWORK CONSISTING OF MS CHANNEL OF SIZE (100X50X6)MM BELOW
GROUND LEVEL AND OF SIZE(75X40X6)MM ABOVE GROUND LEVEL AND
DETACHABLE CHAINLINK FENCING 2.4 M MS ANGLE OF SIZE(50X50X6)MM WITH MS FLAT(50X6)MM. AS PER
16 3500101915 RMT 4,500
HEIGHT APPROVED DRAWING, INCLUDING EXCAVATION, CONCRETE FOUNDATION
OF GRADE 1:2:4, FINISHED WITH PLASTER , MS SECTIONS TO HAVE ONE
COAT OF PRIMER AND TWO COATS OF SYNTHETIC ENAMEL PAINT ETC.
COMPLETE, SUBSTATION AREA TO BE CLEARED AND DISPOSED THE EXCESS
MATERIAL AS PER MCGM AND EMS NORMS

sUPPLYING AND FIXING (3 AND HALF POINT BOARD)-SUNMICA SWITCH


BOARD 12X10 INCH WITH OLD BLACK ROUND TYPE 3NO OF
17 3500101917 LIGHT POINT BORD SWITCHES,1NO OF 5-POINT 6/16A SWITCHED SOCKET,1NO OF 30 AMPS 1,500
2.5SQMM PVC COPPER ARMOURED CABLE TO GIVE SUPPLY TO BOARD
AND TESTING & COMMISSIONING ETC COMPLETE

LIGHT POINT WIRING IN 3/4" CONDUIT (PVC - FOR CONCEALED and MS


FOR OPEN) USING 2 nos 1.5 sq.mm & 1 no. 1.0 sq.mm PVC INSULATED
18 3500101916 LIGHT POINT WIRING COPPER COPPER CONDUCTOR WIRE & 1.0 sq.mm WIRE FOR EARTHING OF NOS 300
APPROVED GRADE & MAKE, FROM SWITCHBPOARD TILL VARIOUS LIGHT
POINTS WITH P&F ALL ACCESSORIES ETC COMPLETE

SUPPLYING AND LAYING OF 2 CORE X 2.5 SQMM PVC COPPER ARMOURED


19 3111300021 PVC Cable - 2 core x 2.5 Sqmm RMT 42
CABLE TO GIVE SUPPLY TO BOARD AS DIRECTED BY ENGINEER IN CHARGE

P&F SUBSTATION NAME PLATE AND SAFETY BOARDS FOR SUBSTATION


NAME PLATE-1) PROVIDING AND FIXING 2' X 1' VITRIFIED TILE FLUSHED
AND LEVELLED WITH THE EXTERNAL PORTION OF SUBSTATION WALL AS
PER LOCATION APPROVED BY ENGINEER IN CHARGE. 2) SUPPLYING AND
STICKING OF SUNBOARD OF 3MM THICKNESS AND SIZE 2' X 1' WITH
PRINTING OF SUBSTATION NAME OF SIZE AS PER ENGINEER IN CHARGE &
RELIANCE MONOGRAM BY 3M TWO WAY TAPE ON THAT VITIRIFIED TILE.
FOR SAFETY BOARDS-1) SUPPLYING AND FIXING OF POLYCARBONATE
20 3111300026 Substation Name plate and Safety Board NOS 5,200
SHEET OF THICKNESS 3MM WITH 3M PAPER WITH BOTH WAY TAPE FOR
STICKING OF FIRST AID CHART (2' X 2'), FIRE EXTINGUISHER (10" X 3") AND
FIRE BUCKET BOARD (10" X 3") AS PER LOCATION APPROVED BY ENGINEER
IN CHARGE 2) SUPPLYING AND STICKING OF 3 NOS. OF SUNBOARD WITH
PRINTING OF OF FIRE
EXTINGUISHER, FIRE BUCKET AND FIRST AID CHART OF 3MM THICKNESS
AND OF SIZE AS PER ENGINEER IN CHARGE BY TWO WAY TAPE ON THAT
POLYCARBONATE SHEET.

P&F Galvanised precoated sheet roofing :


1) Providing & Fixing Tata BlueScope LYSAGHT TRIMDEK® colour coated
profile sheet of 0.45 mm BMT
(0.50mm TCT excluding paint thickness).
2) The steel sheet shall have brand marking of coated steel manufacturer
(product details, date, mfg
name, etc) on back side at regular interval confirming genuineness of the
material.
3) The steel sheet shall be fastened with nominal 40 mm zinc coated or
nominal 25 mm Zinc-Tin alloy
21 3500100813 Galvanised precoated sheets SQM 990
coated, Hex head, self-drilling screw, as per AS 3566-2002 Class 3 fasteners
with EPDM washer and also
as per the requirement considering the profile shape and design load. The
profile sheet, fastener size etc.
shall be approved by the concern authority.
4) All the accessories like gutter/ flashing / capping shall be made from the
same material which is used
for main cladding application. The measurement shall be based on
finished/covered surface area.
Installation to be done in neat line, level, slope etc complete
Bill Of Quanti
Construction of RI A
Sr. Item Code Short Description

1 3450514000 GRANUAL SUB BASE (GSB)

2 3500100874 WET MIX MUCADUM (WMM)

3 3250516000 PROVIDIND BITUMINOUS LIQUID SEAL COAT


4 3010110000 EXC SOIL INCLUDING DEWATERING OM -2M

5 3450630000 Carting away debris


6 Dense Graded Bituninous Macadam

Total (Rs.)
Bill Of Quantities
Construction of RI AT JARI MARI
Detailed Description Unit Rate (Rs.)

Granual Sub Base (GSB).Providing, laying, spreading and


compecting specified graded crush stone in granular sub
base course of size up to 40mm including draindge C85
premixing the material in mechanical mixture laying in
uniform.

layers of 75mm (Compacting thichness each) with Paver


finisher on prepared murrum surface and compacting 1 1,000.00
with 10 T vibrating

tendem roller to achive the density of 98 % of MDD


including all material labour, machinary with all lead and
lift etc,

complete as directed by Engineer In Charge

Providing, laying, spreading and compacting specified wet


graded crush stone in Wet Mix base course of thickness
200mm (compacted Thickness) including draindge C85
premixing the material from planti in: mechanical mixture
laying in uniform layers of 75mm (Compacting thichness
1 650.00
each) with Paver finisher on prepared murrum surface
and compacting with 10 T vibrating tendem roller to
achive the density of 98 % of MDD including all material
labour, machinary with all lead and lift etc, complete as
directed by Engineer In Charge

Providing Bituminous liquid seal coat 25mm average


thickness to balck top surface including supplying all
materials, all leads, preparing existing road surface,
heating and applying bitumen by bowzer spreading chips
& rolling by Power roller complete.

The spreading of 60/70 grade bitumen shall be done by


1 390.00
bowzer @ 1.25 kg/ m2 The 6mm stone chips shall be
spreaded at the rate of 0.012 m3 /m2 on the road surface
and then rolled

Royalty Charges Including all Statutory charges in the


scope of Contractor. Contractor has to Submit all Royalty
required for this item at the time of Supply of material.
Excavation to required side slopes below ground level in
all kinds of ordinary and hard soils such as Clay, sand,
sandy clay, gravel, soft moorum, hard moorum etc. for
foundations, pits, trenches etc. including de-watering,
levelling, dressing, protection of side slopes by proper
shoring, strutting as necessary and transporting excess
excavated soil to stack or fill within the basic initial lead of
500m and unloading. stacking, filling, levelling and
dressing to required levels and grades etc. complete as
per specifications,
and as directed by Engineer for following depths.(Only
PCC plan area as per drawing shall be measured for
payment.) The payment for this item will be as given as
1 290.00
per following example:For a depth of 4.0M from ground
level, the excavation for the first 2.0M depth and
corresponding quantity will be paid as per rate in (i)
below and the excavation for remaining 2.OM portion
and it's correspoding quantity will be paid as per rate in
(ii) below:-.

In case, if their will be any statutory Royalty charges same


shall be paid by contractor to the concerned Government
authorities before commencement of excavation.
Contractor should submit the copy of same to concerned
engineer before start of works. Contractor shall be solely
liable for legal and financial issues in this regard.

Debris, Disposal of excavated earth/murum/ashphalt/soft


rock/hard rock etc. from the excavated trench in the R-
Infra Distribution areas and transported to the designated 1 440.00
places of BMC/MMRDA/PWD/MBMC or private property
owner No bulkage will be considered.
Viscosity grade bitumen-VG10, VG20, VG30, VG40 etc.
Modified Bitumen- Polymer Modified Bitumen (PMB),
Crumbled Rubber Method Bitumen (CRMB) etc.
Coarse Aggregate:
Coarse aggregate shall consist of crushed rock or crushed
gravel.
Separate stock pile for DBM purpose to be maintained for
each size of aggregate.
Fine Aggregate:
Fine aggregate shall consist of crushed or naturally
occurring material or a combination of two.
Filler:
Filler shall be consisting of finally divided mineral matter
such as rock dust, hydrated lime of cement.
Anti-Stripping Agent:
Anti-stripping available either in liquid form or powder 1
form (hydrated lime, cement, rock filler). It will improve
the moisture sensitivity of aggregates.
Anti-striping agent is the special item and the codes
requirement to be satisfied before use.
10 min test to be performed as per ASTM D3625 to
evaluate the stripping of aggregate. Royalty Charges
Including all Statutory charges in the scope of Contractor.
Contractor has to Submit
all Royalty required for this item at the time of Supply of
material. 850
Total (Rs.)
RI
Quantity Amount (Rs.)

48.30 48,300.00

225.00 146,250.00

360.00 140,400.00
94.50 27,405.00

94.50 41,580.00
225.00 191,250.00

595,185.00