INSTALLATION INSTRUCTIONS
WARNING: TO BE INSTALLED AND/OR USED IN ACCORDANCE WITH APPROPRIATE ELECTRICAL CODES AND
Cat. Nos. REGULATIONS.
/
IPI06-1L Single Pole (One location) or WARNING: IF YOU ARE NOT SURE ABOUT ANY PART OF THESE INSTRUCTIONS, CONSULT A QUALIFIED
/
IPI10-1L 3-Way (Multi-location) ELECTRICIAN.
/
IPM06-1L
IPM10-1L / 120VAC, 60Hz WARNING: TO AVOID OVERHEATING AND POSSIBLE DAMAGE TO THIS DEVICE AND OTHER EQUIPMENT, DO NOT
INSTALL TO CONTROL A RECEPTACLE, FLUORESCENT LIGHTING, A MOTOR- OR A TRANSFORMER-OPERATED
APPLIANCE OTHER THAN APPROPRIATE LOW-VOLTAGE LIGHTING.
Incandescent
CAUTION (For Incandescent Only): USE WITH INCANDESCENT OR 120V HALOGEN FIXTURES ONLY.
Cat. No. IPI06-1L,
/ 600W (Lighted)
CAUTION (For Magnetic Low-Voltage Only):
Cat. No. IPI06-10,
/ 600W 1. USE WITH MAGNETIC LOW-VOLTAGE TRANSFORMERS, INCANDESCENT, OR 120V HALOGEN FIXTURES ONLY. USE
Cat. No. IPI10-1L,
/ 1000W (Lighted) A LEVITON ELECTRONIC LOW-VOLTAGE DIMMER TO CONTROL ELECTRONIC (SOLID STATE) LOW-VOLTAGE
TRANSFORMERS.
2. WHEN A MAGNETIC LOW-VOLTAGE CIRCUIT IS OPERATED AT A DIM LEVEL, WITH ALL LAMPS INOPERATIVE,
Magnetic Low-Voltage EXCESS CURRENT MAY FLOW THROUGH THE TRANSFORMER. TO AVOID POSSIBLE TRANSFORMER FAILURE DUE
TO OVERCURRENT, USE A TRANSFORMER THAT INCORPORATES THERMAL PROTECTION OR A FUSE AT THE
Cat. No. IPM06-1L,
/ 600VA (Lighted) PRIMARY WINDINGS.
Cat. No. IPM10-1L,
/ 1000VA (Lighted) OTHER CAUTIONS:
1. USE ONLY ONE (1) DIMMER PER LOAD. THE SWITCH(ES) WILL TURN THE LIGHT ON AT THE BRIGHTNESS LEVEL
SELECTED AT THE DIMMER.
2. DISCONNECT POWER WHEN SERVICING OR CHANGING LAMPS.
INSTALLATION INSTRUCTIONS 3. USE THIS DEVICE ONLY WITH COPPER OR COPPER CLAD WIRE. WITH ALUMINUM WIRE USE ONLY DEVICES
MARKED CO/ALR OR CU/AL.
MULTI-GANG INSTALLATION:
R
push-button switch several times (see Figure 1). The GREEN LED
PK-92943-10-00-0A will turn ON and OFF indicating power to the switch.
2. The frame has snaps on its sides. Using your fingers, grip
around the Decora® frame and push on one side to
release it from the strap (see Figure 2).
Line
120VAC, 60Hz
Black
Green
Load
}
Ground
3. Take the new frame and position it properly to the strap. White
Line up the plastic snaps with the square holes in the
strap. Insert the snaps on one side of the frame into the Neutral (White)
strap.
4. Firmly press sideways and down to slip the other snaps
into place. The frame snaps in with a audible click. Wiring Diagram 2 - Two Location Control Application
Ensure that all four snaps are secure.
5. Moving the slider up or down will automatically engage
Common
the slider control mechanism. Replace Decora® wallplate. Terminal 3-Way Switch Dimmer
The color conversion is complete. (Black Screw)
(OR PRIMARY SIDE OF
TO OPERATE Hot (Black) MAGNETIC LOW-VOLTAGE
Black Red TRANSFORMER)
• GREEN LED will remain ON when the lights are OFF
- Facilitates access to switch in the dark (Lighted Device Black
ONLY).
• Depress push-button switch to ON position
- Lights will turn ON (GREEN LED will turn OFF
Line
120VAC, 60Hz
Green
Black
Green
Load }
- Lighted Device ONLY). Ground Ground White
• Move slider control lever - Lights will brighten or dim to
level set. Neutral (White)
• Depress push-button switch to OFF position
- Lights will turn OFF (GREEN LED will turn ON
- Lighted Device ONLY). Wiring Diagram 3 - Three Location Control Application
• Lights will turn ON at set brightness level (from either
switch location in a 3-way installation).
Common
TROUBLESHOOTING Terminal 3-Way Switch 4-Way Switch Dimmer
(Black Screw)
• Light does not turn ON and ON/OFF LED does not (OR PRIMARY SIDE OF
turn ON Hot (Black) 2 Black Red
MAGNETIC LOW-VOLTAGE
TRANSFORMER)
- Circuit breaker or fuse has tripped. 1
- Lamp is burned out. Black
2 Black
- Lamp is not connected to line Neutral.
• Lights Flickering
- Lamp has a bad connection.
Line
120VAC, 60Hz
Green
1
Green Green
Load }
- Wires not secured firmly with wire connectors. Ground Ground Ground White
Neutral (White)
1 Travelers between switches "IN"
2 Travelers between switches "OUT"