Data sheet for SINAMICS G120X

Article No. : 6SL3220-3YE40-0AB0

Client order no. : Item no. : Figure similar


Order no. : Consignment no. :
Offer no. : Project :
Remarks :

Rated data Inputs / outputs


Input Standard digital inputs

Number of phases 3 AC Number 6

Line voltage 380 ... 480 V +10 % -20 % Switching level: 0 → 1 11 V

Line frequency 47 ... 63 Hz Switching level: 1 → 0 5V

Rated voltage 400V IEC 480V NEC Max. inrush current 15 mA

Rated current (LO) 104.00 A 91.00 A Fail-safe digital inputs

Rated current (HO) 94.00 A 80.00 A Number 1

Output Digital outputs

Number of phases 3 AC Number as relay changeover contact 2

Rated voltage 400V IEC 480V NEC 1) Output (resistive load) DC 30 V, 5.0 A

Rated power (LO) 55.00 kW 75.00 hp Number as transistor 0

Rated power (HO) 45.00 kW 60.00 hp Analog / digital inputs

Rated current (LO) 110.00 A 96.00 A Number 2 (Differential input)

Rated current (HO) 90.00 A 77.00 A Resolution 10 bit

Rated current (IN) 113.00 A Switching threshold as digital input

Max. output current 149.00 A 0→1 4V

Pulse frequency 4 kHz 1→0 1.6 V

Output frequency for vector control 0 ... 200 Hz Analog outputs

Output frequency for V/f control 0 ... 550 Hz Number 1 (Non-isolated output)

Overload capability PTC/ KTY interface

Low Overload (LO) 1 motor temperature sensor input, sensors that can be connected PTC, KTY and
Thermo-Click, accuracy ±5 °C
110% base load current IL for 60 s in a 300 s cycle time

High Overload (HO) Closed-loop control techniques

150% x base load current IH for 60 s within a 600 s cycle time V/f linear / square-law / parameterizable Yes

General tech. specifications V/f with flux current control (FCC) Yes

Power factor λ 0.90 ... 0.95 V/f ECO linear / square-law Yes

Offset factor cos φ 0.99 Sensorless vector control Yes

Efficiency η 0.97 Vector control, with sensor No

Sound pressure level (1m) 70 dB Encoderless torque control No

Power loss 3) 1.730 kW Torque control, with encoder No

Filter class (integrated) RFI suppression filter for Category C2

EMC category (with accessories) Category C2

without SIRIUS device (e.g. via S7-


Safety function "Safe Torque Off"
1500F)

Communication
Communication USS, Modbus RTU, BACnet MS/TP

Technical data are subject to change! There may be discrepancies between calculated and rating plate values. Page 1 of 3 Generated Mon Jul 29 12:54:48 CET 2024
Data sheet for SINAMICS G120X

Article No. : 6SL3220-3YE40-0AB0

Ambient conditions Mechanical data


Class 3C2, according to IEC 60721-3-3: Degree of protection IP20 / UL open type
Standard board coating type
2002
Frame size FSE
Cooling Air cooling using an integrated fan
Net weight 29 kg (63.93 lb)
Cooling air requirement 0.083 m³/s (2.931 ft³/s)
Dimensions
Installation altitude 1,000 m (3,280.84 ft)
Width 275 mm (10.83 in)
Ambient temperature
Height 551 mm (21.69 in)
Operation -20 ... 45 °C (-4 ... 113 °F)
Depth 248 mm (9.76 in)
Transport -40 ... 70 °C (-40 ... 158 °F)

Storage -25 ... 55 °C (-13 ... 131 °F) Standards


UL, cUL, CE, C-Tick (RCM), EAC, KCC,
Relative humidity Compliance with standards
SEMI F47, REACH
95 % At 40 °C (104 °F), condensation
Max. operation EMC Directive 2004/108/EC, Low-
and icing not permissible CE marking
Voltage Directive 2006/95/EC

Connections
Converter losses to IEC61800-9-2*
Signal cable
Efficiency class IE2
0.15 ... 1.50 mm²
Conductor cross-section Comparison with the reference
(AWG 24 ... AWG 16) 48.3 %
converter (90% / 100%)
Line side

Version screw-type terminal I 1,190.0 W (1.6 %) 1,390.0 W (1.8 %) 1,730.0 W (2.3 %)


100%
25.00 ... 70.00 mm²
Conductor cross-section
(AWG 6 ... AWG 3/0)

Motor end

Version Screw-type terminals

25.00 ... 70.00 mm² 661.0 W (0.9 %) 733.0 W (1.0 %) 841.0 W (1.1 %)
Conductor cross-section
(AWG 6 ... AWG 3/0) 50%

DC link (for braking resistor)


482.0 W (0.6 %) 512.0 W (0.7 %)
PE connection Screw-type terminals 25%

Max. motor cable length

Shielded 150 m (492.13 ft)


50% 90% f
The percentage values show the losses in relation to the rated apparent power of
the converter.

The diagram shows the losses for the points (as per standard IEC61800-9-2) of
the relative torque generating current (I) over the relative motor stator frequency
(f). The values are valid for the basic version of the converter without
options/components.

*calculated values

1)
The output current and HP ratings are valid for the voltage range 440V-480V
3)
Typical value. More information can be found in the element group "Converter losses to IEC 61800-9-2" in this datasheet.

Technical data are subject to change! There may be discrepancies between calculated and rating plate values. Page 2 of 3 Generated Mon Jul 29 12:54:48 CET 2024
Data sheet for SINAMICS G120X

Article No. : 6SL3220-3YE40-0AB0

Operator panel: Intelligent Operator Panel (IOP-2)

Screen Ambient conditions


Display design LCD color Ambient temperature

Screen resolution 320 x 240 Pixel Operation 0 ... 50 °C (32 ... 122 °F)
55 °C only with door installation kit
Mechanical data
Storage -40 ... 70 °C (-40 ... 158 °F)
Degree of protection IP55 / UL type 12
Transport -40 ... 70 °C (-40 ... 158 °F)
Net weight 0.134 kg (0.30 lb)
Relative humidity at 25°C during
Dimensions
Max. operation 95 %
Width 70.00 mm (2.76 in)
Approvals
Height 106.85 mm (4.21 in)
Certificate of suitability CE, cULus, EAC, KCC, RCM
Depth 19.65 mm (0.77 in)

Technical data are subject to change! There may be discrepancies between calculated and rating plate values. Page 3 of 3 Generated Mon Jul 29 12:54:48 CET 2024