LNL M2220 Datasheet 07232024 tcm841-231628
LNL M2220 Datasheet 07232024 tcm841-231628
LNL-M2220
Intelligent Dual
Reader Controller
TCP/IP NETWORK
OnGuard® LNL-1300 LNL-1320 LNL-1100 LNL-1200
Security Server Single Reader Dual Reader Input Control Module Output Control Module
Interface Module Interface Module Up to 16 Inputs per Up to 16 Outputs per
LNL-1100 LNL-1200
Option 2.1
Option 2.2
-OR-
Specifications The interface is for use in low voltage, Class 2 Circuits only.
The installation of this device must comply with all local fire and electrical codes.
Primary Power 12 to 24 VDC ± 10%, 500 mA maximum (reader current not included) Environmental
Reader Ports 600 mA maximum each (add up to 600 mA to primary power current each) -55° to +85° C, storage
Primary Host Communication Ethernet: 10-BaseT/100Base-TX Temperature
0° to +70° C, operating
Secondary Host Communication USB port (2.0) with optional adapter: pluggable model USB2-OTGE100 Humidity 5 to 95% RHNC
One each: 2-wire RS-485, 2,400 to 115,200 bps, asynchronous, half-duplex, Heat Output at 12 VDC, 20.5 BTU/hr
Serial I/O Device
1 start bit, 8 data bits, and 1 stop bit (BTUs) at 24 VDC, 22.9 BTU/hr
Eight unsupervised / supervised, standard EOL: 1k/1k ohm, 1% 1/4 watt; two Approvals FCC Part 15, CE, RoHS, UL 294
Inputs
unsupervised inputs dedicated for cabinet tamper and UPS fault monitoring
Four relays: Normally open contact (NO): 5 A @ 30 VDC resistive; Normally
Outputs
closed contact (NC): 3 A @ 30 VDC resistive
Memory/Clock backup: Super Capacitor (10 days). Optional, 3V Lithium, type
Battery
BR2330 or CR2330 (battery not included, field installable).
Reader Interface
12 VDC ± 10% regulated, 600 mA maximum each reader (input voltage [VIN]
Parts and Spare Parts
Power (Jumper selectable) must be greater than 17 VDC) or 12 to 24 VDC ± 10% (input voltage passed
through), 600 mA maximum each reader Part No. Description
Data Inputs TTL compatible, F/2F or 2-wire RS-485
9,600 to 115,200 bps, asynchronous, half-duplex, 1 start bit, 8 data bits, and
6 MB on-board flash memory
RS-485 Mode available for cardholder
1 stop bit. Maximum cable length: 2,000 ft. (609.6m)
LED Output TTL levels, high > 3 V, low < 0.5 V, 5 mA source/sink maximum
LNL-M2220 database; 500,000 event
Buzzer Output Open collector, 12 VDC open circuit maximum, 40 mA sink maximum
super capacitor backed RAM
for event log.
Cable Requirements
Power and Relays One twisted pair, 18 to 16 AWG USB-to-Ethernet converter,
Ethernet CAT-5, minimum for LNL X-Series and M-Series
TTL Reader 18 AWG, depending on length and requirements Controllers only. Provides
USB2-
Alarm Input One twisted pair, 30 ohms maximum, typically 22 AWG @ 1,000 ft. (304.8m) optional Secondary NIC
OTGE100
One twisted pair with drain wire and shield, 120 ohm impedance, 24 AWG, connection. Second NIC
RS-485 I/O Device Port
4,000 ft. (1,219m) maximum should be on different subnet
One twisted pair with drain wire and shield, 120 ohm impedance, 24 AWG, than primary NIC.
RS-485 Reader Port
2,000 ft. (610m) maximum
Mechanical
Dimensions 8.0 W x 6.0 L x 1.0 H in. (203.2 x 152.4 x 25mm)
Weight 9.0 oz. (255g) nominal, board only
LenelS2.com
(866) 788-5095