SINGLE AISLE TECHNICAL TRAINING MANUAL
TOILET SYSTEM MONITORING (3)
symbol to indicate if a lavatory is inoperative or if the whole toilet system GENERAL is inoperative. Examples of messages list box: The toilet system is monitored by the Vacuum System Controller (VSC) - LAVatory X flush control unit water valve failure: SHUT OFF WATER function, which is integrated inside the Cabin Intercommunication Data SUPPLY: LAV XX, System (CIDS) director (DIR). During aircraft power-up on ground and - 115V AC failure or generator overheat: VACUUM SYSTEM during flight, the system external circuits of the vacuum toilet system are DISABLED ON GROUND, monitored continuously. - liquid level transmitter failure: VACUUM SYSTEM DISABLED - FLUSH CONTROL UNIT WASTE TANK FULL, - liquid level sensor failure: MAINTENANCE REQUIRED - WASTE The BITE in each flush control unit monitors the water valve, the flush WATER, valve and the internal control circuitry. If a fault is detected, it is - service door open and landing gear down: VACUUM SYSTEM transmitted through the Decoder/Encoder Unit (DEU) B to DIR 1 and 2 DISABLED - GROUND SERVICING. of the CIDS. A CAUTion amber button, located in the upper left corner of the touchscreen, comes on and flashes when CIDS receives a message which VSC FUNCTION cannot be shown immediately. The VSC functions integrated inside the CIDS DIRs are: - system control and monitoring, - fault reporting. The DIR calculates and transmits signals to the Flight Attendant Panel (FAP) and optionally to the waste service panel to indicate the waste tank level and to report system defects. The DEU B transmits system defects to the DIR through the middle line data bus. The DIR memorizes the defect signals and send them to the Centralized Fault Display System (CFDS) for ground maintenance and inspection. The DEU B is also connected to RS 232-C interface unit and used in Workshop.
NOTE: Each toilet assembly has a separate DEU B.
FAP WATER/WASTE PAGE INDICATING
The FAP WATER/WASTE page gives information about water and waste. The waste tank level is displayed on this page. Fault, system and inoperative messages can also be displayed in the list box and on the A/C MAINTENANCE COURSE - T1 & T2 TOILET SYSTEM MONITORING (3) 38 - WATER & WASTE Page 72