Wärtsilä id: DBAC517658 -
Submittal Data: 4MXW8518A1 - 4TXK8518A1 18,000 BTU/H Heat Pump System
Job Name: Location: Date:
Purchaser: Engineer:
Submitted to: For Reference Approval Construction
Unit Designation: Schedule No.:
SPECIFICATIONS MISCELLANEOUS
COOLING Refrigerant Type R-410A
Rated Capacity @95F (AHRI) 18000(Btu/h) Refrigerant Connections
Minimum Capacity 6000(Btu/h) Gas Line Φ12(1/2”)
Maximum Capacity 22350(Btu/h) Liquid Line Φ6(1/4”)
SEER 18 Drain Hose Size
HEATING Length 680mm
Rated Capacity @47F (AHRI) 25000(Btu/h) Diameter Φ28mm
Rated Capacity @17F (AHRI) 16000(Btu/h) Maximum Refrigerant Line Length 25m
Minimum Capacity 4100(Btu/h) Maximum Refrigerant Line Height Diff. 10m
Maximum Capacity 25500(Btu/h) Additional Refrigerant 30g/m
HSPF 10.5
GENERAL FEATURES
ELECTRICAL CHARACTERISTICS
Coil type (AL/CU) Aluminum fin-copper tube
Power Supply 208-230V Filters Active Carbon and Catechin Filters
Breaker Size 25A Operating Range (outdoor ambient) Cooling mode: From 64 to 118 ºF
RLA Cooling/Heating (Amps) 7.67A / 14.06A Heating mode: from 5 to 75 ºF
Controls Wireless Auto restart 3 mins
Expansion Device Electronic Expansion Valve
INDOOR UNIT
Airflow (Low/Med/High/Turbo)
Cooling (wet coil) 550/650/780/850(m³/h)
Heating (dry coil) 550/650/780/850(m³/h)
Noise Level dB(A) (Low/Med/High/Turbo) 35/40/44/46
Fan Motor Amps 0.09
Indoor Unit: 4MXW8518A1
OUTDOOR UNIT
Compressor Rotary
MCA 11.6A
Outdoor Unit: 4TXK8518A1
Noise Level dB(A) ≤55
DIMENSIONAL DATA OUTDOOR INDOOR
Height 700mm 298mm
Width 890mm 940mm Remote Controller
Depth 340mm 200mm
Net Weight 50kg 13kg
Trane has a policy of continuous product and product data improvements and reserves the right to change design and specifications without notice.
Wärtsilä id: DBAC517658 -
Dimensions: 4MXW8518A1 - 4TXK8518A1
4MXW8518A1 Air in Unit: mm
940 Installation plate
298
200 Air out
Space to the ceiling
575 150
Above
Space to the wall
150 Above 150 Above
15 18 18 15 15 18 18 15
275 +0.5
9.5
Space to the wall
-0
3000 2500
Above
Above
Air outlet side
Space to the floor
55 (99) 55
(99)
● The dimensions of the space necessary for correct
Installation plate installation of the appliance including the minimum
permissible distances to adjacent structures
4TXK8518A1 Unit: mm
890 257
REQUIRED SPACE
>600
>6
700
00
>600
>600
340
Bolt
600mm or more without any
obstruction in front and on Nut
both sides of the unit.
540
Trane optimizes the performance of homes and buildings around the world. A business of Ingersoll Rand, the leader in creating and sustaining safe, comfortable
and energy efficient environments, Trane offers a broad portfolio of advanced controls and HVAC systems, comprehensive building services, and parts.
For more information, visit www.trane.com.
2010 Trane
© 2009 Trane All
All rights reserved
rights reserved Produced on 20% post-consumer recycled paper, using
MS-PRQ011-EN October
ADM-SLB-010-EN October07, 2010
2009 environmentally friendly print practices that reduce waste.