Catalog 1308242

Issued 3-03 P&B

CH series
Mid- To Low-Priced
CMOS IC Time Delay Relay
• Choice of timing modes
– Delay on operate
– Delay on release
– Interval on
• Fixed or knob adjustable types
• 10A output relay with DPDT contacts
• Various models time from 1 to 180 sec.

File E22575
File LR15734
Users should thoroughly review the technical data before selecting a product part
number. It is recommended that user also seek out the pertinent approvals files of
the agencies/laboratories and review them to ensure the product meets the
requirements for a given application.

Timing Modes Contact Data @ 25°C


Delay on operate – Delay period begins when input voltage is applied. At Arrangements: 2 Form C (DPDT).
the end of the delay period, the relay will operate and will not release until Material: Silver-cadmium oxide alloy.
input voltage is removed. Reset occurs when input voltage is reapplied. Rating: 10A @ 30VDC or 277VAC, resistive; 1/2 HP @ 250VAC; 1/3 HP @
120VAC.
INPUT ON Expected Mechanical Life: 10 million operations.
VOLTAGE OFF Expected Electrical Life: 100,000 operations, min., at rated load.
N.O. RELAY ON
CONTACTS OFF TIME

Initial Dielectric Strength


Between Open Contacts: 500V rms, 60 Hz.
Between All Other Conductors: 500V rms, 60 Hz.
Delay on release – Input voltage must be applied continuously to operate
the internal relay. When the control switch is closed, the relay energizes.
When the control switch is opened, timing begins. When timing is
complete, the relay will de-energize. Time may be reset to zero during
timing by closing the control switch.
Input Data @ 25°C
CONTROL ON
SWITCH OFF Voltage: 24 through 240VAC and 24VDC.
N.O. RELAY ON Power Requirement: AC Types: Typically less than 3 VA.
TIME DC Types: Typically less than 3 W.
CONTACTS OFF
Transient Protection: Yes.
Reverse Voltage Protection: Yes.

Input Voltages & Limits @ 25°C


Voltage Nominal Minimum Maximum
Interval on – The relay energizes and timing begins when input voltage is Type Voltage Voltage Voltage
applied. At the end of the time delay period the relay will de-energize.
Reset is accomplished by removing, then reapplying, the input voltage. AC 24 20 28
120 105 130
INPUT ON 240 210 260
VOLTAGE OFF
DC 24 20 32

Note: DC voltage must be filtered (5% p-p ripple max. at nom. voltage).
N.O. RELAY ON AC models will operate on 50 or 60 Hz.
CONTACTS OFF TIME

Environmental Data
Timing Specifications Temperature Range: Storage: -55°C to +85°C.
Timing Ranges: From 1 to 180 sec. Operating: -10°C to +55°C.
Timing Adjustment: Fixed and knob adjustable.
Tolerance (for AC units add ±1/2 cycle 60 Hz.):
Knob Adj. Types:–0, +20% of max. specified at high end of timing range;
min. specified, or less, at low end. Mechanical Data
Fixed Types: ± 5%. Termination: 8- or 11-pin octal style plug.
Res. Adj. Types: ± 5% at high end of timing range; min. specified, or less, Enclosure: White plastic case. Knob adjustable types have dial scale for
at low end. reference only.
Delta Time (for AC units add ±1 cycle 60 Hz.): ± 10%. Sockets: Models with 8-pin base fit either 27E122 or 27E891 (snap-on)
Repeatability (for AC units add ±1 cycle 60 Hz.): ± 2%. screw terminal sockets. 11-pin types fit either 27E123 or
Release Time: 125 ms, typ.; 200 ms, max. 27E892 (snap-on) screw terminal sockets.
Recycle Time: 125 ms, typ.; 200 ms, max. Weight: 6 oz. (170g) approximately.

Dimensions are shown for Dimensions are in inches over Specifications and availability www.tycoelectronics.com
1226 reference purposes only. (millimeters) unless otherwise subject to change. Technical support:
specified. Refer to inside back cover.
Catalog 1308242
Issued 3-03 P&B
Ordering Information – Authorized distributors are more likely to stock boldface items listed below.

Delay on Operate Models Delay on Release Models


Voltage Time Adjustment Wiring Dia. Part Number Voltage Time Adjustment Wiring Dia. Part Number
24VAC 1 to 10 Sec. Knob 1 CHB-38-30001 24VAC 1 to 10 Sec. Knob 3 CHB-38-30011
1 to 180 Sec. CHB-38-30003 1 to 10 Sec. CHB-38-70011
1 to 10 Sec. CHB-38-70001 120VAC 1 to 60 Sec. Knob 3 CHB-38-70012
120VAC 1 to 60 Sec. Knob 1 CHB-38-70002 1 to 180 Sec. CHB-38-70013
1 to 180 Sec. CHB-38-70003 24VDC 1 to 10 Sec. Knob 3 CHD-38-30011
120VAC 10 Sec. Fixed 1 CHA-38-70001 1 to 180 Sec. CHD-38-30013
240VAC 1 to 10 Sec. Knob 1 CHB-38-80001
1 to 10 Sec. CHD-38-30001 Interval on Models
24VDC 1 to 60 Sec. Knob 1 CHD-38-30002 Voltage Time Adjustment Wiring Dia. Part Number
1 to 180 Sec. CHD-38-30003
1 to 10 Sec. CHB-38-70021
120VAC 1 to 60 Sec. Knob 1 CHB-38-70022
1 to 180 Sec. CHB-38-70023
24VDC 1 to 10 Sec. Knob 1 CHD-38-30021

Outline Dimensions

2.406 MAX.
(61.1)

.60
➛ 2.937 MAX. ➛ .56 ➛ 1.781 MAX.
(15.2)
➛ (74.6) ➛ (14.2) (45.2) ➛

Wiring Diagrams – Bottom Views (pins numbered clockwise from keyway)

EXTERNAL RESISTOR
EXT SWITCH*





+ INPUT _ + _ + -
INPUT
(DC POLARITY INDICATED) (DC POLARITY INDICATED) AC INPUT
Fig. 1 Fig. 2 Fig. 3
8 Pin 11 Pin 11 Pin

* If control switch is closed when power is applied, relay will immediately energize. A 50 millisecond minimum switch closure is required. IMPORTANT: A dry circuit switch is recommended. A
“dry circuit” switch is one rated to reliably switch currents of less than 50mA. Use of a switch rated for other than dry circuit may result in failure of the time delay relay to function properly.
** Note: Input polarity for DC operation. For most reliable operation on AC, connect high side to “+” and low side to “–”.

Dimensions are shown for Dimensions are in inches over Specifications and availability www.tycoelectronics.com
reference purposes only. (millimeters) unless otherwise subject to change. Technical support: 1227
specified. Refer to inside back cover.