HTK55AA
KAPPA LBP Compressor Date code (YYWW)
White background Yellow background
Top Efficiency 1605 HTK55AA
R600a MADE IN AUSTRIA
a
220-240 V ∼ 50 Hz
220-240V 50Hz
00
B
R6
SUCTION
9 052 1234567 0
General
Code number CDO000034
Approvals EN 60335-2-34 w. Annex AA
Compressors on pallet 100 Variant code
Manufacturer/version code
Application serial number | check digit
Application LBP Suction connector indication
Frequency Hz 50 60
Evaporating temperature °C -35 to -5 –
Voltage range V 187 to 264 –
Max. condensing temperature continuous (short) °C 60 (70) –
Max. winding temperature continuous (short) °C 130 (130) –
S = Static cooling normally sufficient
Cooling requirements
O = Oil cooling
Frequency Hz 50 60 F1 = Fan cooling 1.5 m/s
Application LBP MBP HBP LBP MBP HBP (compressor compartment temperature
equal to ambient temperature)
32°C S – – – – –
F2 = Fan cooling 3.0 m/s necessary
38°C S – – – – – SG = Suction gas cooling normally sufficent
43°C S – – – – – – = not applicable in this area
Remarks on application:
Motor
Motor type RSCR/RSIR
LRA (rated after 4 sec. UL984), HST | LST A – 3.4
Cut in Current, HST | LST A – 8.3
Resistance, main | start winding (25°C) Ω 33.4 28.5
Design
Displacement cm3 5.60
Oil quantity (type) cm3 165 (mineral)
Maximum refrigerant charge g 150
Free gas volume in compressor cm3 1500
Weight without electrical equipment kg 7.80
Dimensions
Height mm A 159.0
B 165.5
Suction connector location/I.D. mm | angle C 6.15 | 35°
material | comment Copper | Rubber plug
Process connector location/O.D. mm | angle D 6.00 | 35°
material | comment Copper | Rubber plug
Discharge connector location/I.D. mm | angle E 5.15 | 40°
material | comment Copper | Rubber plug
Oil cooler connector location/I.D. mm | angle F –
material | comment –
Connector tolerance I.D. mm ±0.05
Remarks:
December 2016 DES.D.564.D1.02 1/2
EN 12900 Household 220V, 50Hz, PTC consumption incl., static cooling
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 31.7 48.5 68.7 76.3 92.3 119 150 173 185
Power cons. in W 39.7 48.5 57.3 60.3 66.1 75.0 84.1 90.3 93.5
Current cons. in A 0.31 0.35 0.39 0.40 0.42 0.46 0.50 0.53 0.54
COP in W/W 0.80 1.00 1.20 1.27 1.40 1.59 1.79 1.91 1.98
ASHRAE LBP 220V, 50Hz, PTC consumption incl., static cooling
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 38.7 59.3 83.9 93.2 113 146 183 211 225
Power cons. in W 39.6 48.4 57.1 60.0 65.8 74.5 83.5 89.5 92.7
Current cons. in A 0.31 0.35 0.39 0.40 0.42 0.46 0.50 0.53 0.54
COP in W/W 0.98 1.22 1.47 1.55 1.71 1.96 2.20 2.35 2.43
ASHRAE LBP 220V, 50Hz, RC 2μF, PTC consumption incl., static cooling
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 38.7 59.3 83.9 93.2 113 146 183 211 225
Power cons. in W 37.9 46.5 55.0 57.8 63.4 72.0 80.8 86.9 90.1
Current cons. in A 0.23 0.25 0.28 0.29 0.31 0.34 0.36 0.38 0.39
COP in W/W 1.02 1.28 1.53 1.61 1.78 2.02 2.27 2.42 2.50
Dimension of evaporation tray Outline dimensions with plastic evaporation tray
8856
Accessories for HTK55AA Code number Test conditions EN 12900 ASHRAE
Household LBP
Run capacitor (optional) 4.8 mm or 6.3 mm spade connectors 2 μF Condensing temperature 55°C 54.4°C
Terminal board 4.8 mm or 6.3 mm spade connectors Ambient temperature 32°C 32.2°C
ZHF0 / DHF0
(incl. PTC and external protector) Suction gas temperature 32°C 32.2°C
Motor Protector AE 23 BY x F0 Liquid temperature no subcooling 32.2°C
Cable clamp (screws not included) 113410_
Cover 157595_
Evaporation tray (optional) 113188_
All-in-one equipment, e.g. 4ZN Code number Mounting accessories Code number
Cover / cable clamp + screws / earthing screw 16168000 on request, various options available
Nidec GA Compressors accepts no responsibility for possible errors in catalogs, brochures, and other printed material. Nidec GA Compressors reserves the right to alter its products without notice.
This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary to specifications already agreed. All trademarks in this
material are the property of the respective companies. Secop and the Secop logotype are trademarks of Nidec Global Appliance Germany GmbH. All rights reserved. www.secop.com
2/2 DES.D.564.D1.02 December 2016