masterseal 610_tds
masterseal 610_tds
High solids protective coating and curing membrane based on emulsified bitumen
APPLICATIONS STORAGE
Agitate before use. As settlement can occur, the drum Store under cover, out of direct sunlight and protect from
should be rolled before decanting material. extremes of temperature. In tropical climates the product
must be stored in an air-conditioned environment. As
PERFORMANCE with all bituminous emulsions, some settlement will
- MasterSeal 610 will act as a curing compound when occur with prolonged storage. It is, therefore, necessary
applied to green concrete. Apply immediately when to invert the drums monthly to disperse the settlement.
formwork is removed. Shelf life is up to 6 month in unopened containers, when
- Will act as a primer for most bitumen based stored as above.
membranes. Failure to comply with the recommended storage
- Concrete coated with MasterSeal 610 will prevent conditions may result in premature deterioration of the
the absorption of saline solutions. On uncoated product or packaging. For specific storage advice
surfaces, salts in groundwater will penetrate and can consult Master Builders Solutions's Technical Services
cause reinforcement corrosion and concrete Department.
deterioration.
Apply by brush, broom or squeegee. Apply one or two SAFETY PRECAUTIONS
coats, depending on the degree of protection required. As with all chemical products, care should be taken
Apply subsequent coats at right angles to the first, during use and storage to avoid contact with eyes,
allowing 12 to 24 hours between coats. Where being mouth, skin and foodstuffs. Treat splashes to eyes and
utilized to damp proof solid floors or where a screed is to skin immediately. If accidentally ingested, seek medical
be applied over MasterSeal 610, apply a second coat at attention. Reseal containers after use. Use in well
right angles and lightly grit to form a key. Allow at least ventilated areas and avoid inhalation. For further
24 hours before application of concrete screed, ensuring information refer to the material safety data sheet.
this is greater than 60mm in thickness.
NOTE
COVERAGE Field service, where provided, does not constitute
2-4 m² per liter per coat depending on use and substrate supervisory responsibility. For additional information
porosity. contact your local Master Builders Solutions
representative.
EQUIPMENT CARE Master Builders Solutions reserves the right to have the
After use, if the MasterSeal 610 has not dried, it may be true cause of any difficulty determined by accepted test
possible to clean tools using soapy water. If the methods.
MasterSeal 610 has dried remove as much as possible
by physically scraping and then remove remainder with
paraffin, white spirit or MasterTop Thinner No. 2.
CONTACT
Should you require any further information, please do
not hesitate to contact us:
www.master-builders-solutions.com/en-sa
[email protected]
M: +966 13 853 8600
The technical information and application advice given in this Master Builders Solutions publication are based on the present state of
our best scientific and practical knowledge. As the information herein is of a general nature, no assumption can be made as to a
STATEMENT OF
product's suitability for a particular use or application and no warranty as to its accuracy, reliability or completeness either expressed
RESPONSIBILITY
or implied is given other than those required by law. The user is responsible for checking the suitability of products for their intended
use.
Disclaimer:
In view of widely varying site conditions and fields of application of our All descriptions, drawings, photographs, data, ratios, weights i.e. stated
products, this technical data sheet is meant to provide general herein can be changed without advance notice and do not represent the
application guidelines only. This information is based on our present condition of the product as stipulated by contract. It is the sole
knowledge and experience. The customer is not released from the responsibility of the recipient of our products to observe possible
obligation to conduct careful testing of suitability and possible proprietary rights as well as existing laws and provisions. The reference
application for the intended use. The customer is obliged to contact the of trade names of other companies is no recommendation and does not
technical help-line for fields of application not expressly stated in the exclude the use of products of similar type. Our information only
technical data sheet under "Fields of Application". Use of the product describes the quality of our products and services and is no warranty.
beyond the fields of application as stated in the technical data sheet Liability is accepted for incomplete or incorrect particulars in our data
without previous consultation with Master Builders Solutions and sheets only in the event of intent or gross negligence, without prejudice
possible resulting damages are in the sole responsibility of the to claims under product liability laws.
customer.
MasterSeal® 610 3/3 Master Builders Solutions Saudi 10-2023