SPECIFICATION SHEET

D4T™ 1/4 DIN Data Logger

Watlow’s D4T™ Combines


the Flexibility of a Modular
I/O Data Logger with
Best-in-Class Ease of Use

The D4T™ data logger from Watlow® offers a data logger with Email and text alerts
a wide range of field removable I/O modules for maximum • Notifies users of an event that has occurred such as an
design flexibility. Configurations can be custom tailored to alarm condition or analog input error
meet the scaling needs of a tremendous range of equipment Trend screens
and applications while providing exactly the hardware types • Create up to four unique trend graph screens
required for compatibility. The D4T data logger also features • Graph any input sensor or process value
a 4.3 inch, color, graphical touch panel. Combining power, Batch processing with bar code data entry
flexibility and functionality, this new data logger offers • Easily collects and manages data records
unmatched versatility, and its best-in-class ease of use could
• Inputs information from bar code scan for fast and easy
very well make user manuals a thing of the past.
data entry
Watlow’s D4T is available through Watlow SELECT®, a program • Provides data security through password and data log
that enables you to quickly identify, configure and receive encrypted file options
your thermal products faster and easier than ever before. • Improves manufacturing robustness via reminder screens
With SELECT, you use a variety of tools to guide your decision, ensuring all data is entered during processing
configure products for an exact fit and quickly receive your • Helps ensure compliance with growing regulations and
order. Visit www.watlow.com/select to learn more. minimizes warranty exposure
• Eliminates part processing skips or walk arounds due to
Features and Benefits
improved quality control
4.3-inch, color touch panel with high-resolution, graphical • Produces formatted data record report for easy receipt or
user-interface
record management uses
• Shortens learning curve and reduces operator errors
• Allows channels, alarms, inputs and outputs to be COMPOSER® graphical configuration PC software
personalized with user defined names • Speeds up and simplifies commissioning
• Intuitive screens layout and menu navigation • Archives and documents controller setup
• Programmable to show information in multiple languages • Connects with controller easily via Ethernet
Data logging Many communications options available including
• Easily complies with regulatory standards with ability to EtherNet/IP™, Modbus® TCP (Ethernet) SCPI
choose encrypted, .CSV or both types of file formats for and EIA-232/485 Modbus® RTU
tamper proof record needs • Offers two USB host ports and one device port
• Enables security using lock-out security levels for different • Simplifies file transfers
user groups • Connects easily
• Simplifies record keeping management with ability to 1 to 24 channel data logger
archive records to the cloud or a connected PC network • Scalable channels, pay for only what you need
• Flexibility to select which parameters to log from one to up • Compatible with temperature, altitude, humidity, ac
to 128 points simultaneously current and other 0-10VDC or 0-20mA process units
• Choose where you want to store the files—inside the • Flexibility to meet diverse process applications
controller, on a connected USB memory device, or to a • Field expandable channels and I/O if application needs
connected PC anywhere in the world grow in the future
• Record as fast as one time per 0.1 second or as slow as one
time per hour
Modular design
• Adapts quickly to evolving requirements
• Offers numerous types of field pluggable modules for
maximum flexibility and easiest compatibility
• Features scalable and modular firmware functions
• Delivers scalable input/output quantities from 1 to 24
Key Features and Options D4T Base Specifications
• Ethernet Modbus® TCP connectivity Line Voltage/Power
• Multiple high-speed USB host ports • High voltage option: 100 to 240VAC +10/-15%, 50/60Hz ±5%
• Universal, thermistor and ac current measurement inputs • Low voltage option: 24 to 28VAC/VDC+10/-15%, 50/60Hz ±5%
• Inputs and outputs expandable from 1 to 24 • Power consumption: 23 W, 54VA
• Programmable timers, counters, math and logic Environment
• Temperature, altitude, relative humidity and Vaisala® humidity • NEMA 4X/IP65 front panel mount configuration only
compensation • Operating temperature: 0 to 122°F (-18 to 50°C)
• USB configuration port • Storage temperature: -40 to 185°F (-40 to 85°C)
• Configuration settings can be stored and recalled • Relative humidity: 0 to 90%, non-condensing
• Removable modules and connectors Agency Approvals
• Front-panel mount and flush mounting options • UL®/EN 61010 Listed, File E185611 QUYX
• Right angle and front-screw terminal options • UL® 508 Reviewed
• UL® listed, CSA, CE, RoHS, W.E.E.E., FM • AMS 2750 E compliant: Analog input process values. Tip: Maximize
• Multi-language options field calibration accuracy and uniformity by using advanced F4T
• English, German, French, Italian, Spanish, Japanese, Korean features such as Calibration Offset and Linearization Function
and Chinese Blocks. Refer to user manual for details.
• USB wired or wireless mouse user interface • RoHS by design, China RoHS Level 2, W.E.E.E.
• Use in hazardous location, dirty environments or • CE
applications with gloves • Windows® Hardware Certification
User Interface
Common Specifications • 4.3 inch TFT PCAP color graphic touch screen
Line Voltage/Power
• LED backlife >50K hours
• Data retention upon power failure via nonvolatile memory
• 4 keys: Home, Main Menu, Back, Help
Functional Operating Range
• Multiple languages
• Type J: -346 to 2192°F (-210 to 1200°C)
• English, German, French, Italian, Spanish, Japanese, Korean
• Type K: -454 to 2500°F (-270 to 1371°C)
and Chinese
• Type T: -454 to 750°F (-270 to 400°C)
• USB wired or wireless mouse functionality
• Type E: -454 to 1832°F (-270 to 1000°C)
• Right click for 4 keys: Home, Main Menu, Back, Help
• Type N: -454 to 2372°F (-270 to 1300°C)
Inputs and Outputs
• Type C: 32 to 4200°F (0 to 2315°C)
• Input sampling: 10Hz
• Type D: 32 to 4200°F (0 to 2315°C)
• Output update: 10Hz
• Type F: 32 to 2449°F (0 to 1343°C)
Communications
• Type R: -58 to 3214°F (-50 to 1767°C)
• Modbus® TCP (Ethernet)
• Type S: -58 to 3214°F (-50 to 1767°C)
• EIA-232/485 Modbus® RTU
• Type B: 32 to 3300°F (0 to 1816°C)
• Isolated communications
• RTD (DIN): -328 to 1472°F (-200 to 800°C)
Data Logging
• Process: -1999 to 9999 units
• User selectable parameters: Up to a maximum of 128 active
Calibration Accuracy
parameters depending on configuration
• Calibration accuracy and sensor conformity: ±0.1% of
• Logging interval: Programmable increments between 0.1 seconds
span, ±1°C at the calibrated ambient temperature and
and 60 minutes if logging to internal memory. Logging directly to
rated line voltage
USB; 1.0 seconds to 60 minutes
• Types R, S, B: ±0.2%
• File types: .CSV for standard data logging or proprietary format for
• Type T below -50°C: ±0.2%
encrypted data log option
• Calibration ambient temperature at 77°F ±5°F (25°C ±3°C)
• Storage: 80MB internal memory or to USB memory stick
• Accuracy span: 1000°F (540°C) min.
• File transfer: Internal memory to USB host port or to Ethernet
• Temperature stability: Typical ±0.1°F/°F (±0.1°C/°C) rise in
Modbus® TCP
ambient max.
• Transfer options: On demand by user or user programmable based
Configuration Diagnostics
on when a new data log file record is available. Utilizes TFTP and
• Indicates if modules present match the expected
Samba protocols
configuration settings
• Record: Date and time stamped
USB Host Port
Batch Processing with Bar Code Data Entry Via USB Scanner
• Total of 2 available
• Compatible with many bar code types including Code 128,
• Version: USB 2.0 hi-speed
Code 39, Extended Code 39, Data Matrix, Interleaved 2 of 5, ISSN,
• Connector: USB Type A, high-retention
SISAC, LOGMARS, QR, UCC/EAN-128 (GS1-128, UPC-A & E)
• Flash drive must be FAT32 file system
• Compatible with most USB scanner types such as Zebra DS4308,
• Max. current 0.5A/port
DS2208, LI2208 and LS2208
System Configuration Requirements
• USB port provides 500mA max. power supply for bar code
• D4T has 6 slots for flex modules (FM)
scanner/base charging
• EIA-232/485 Modbus® RTU flex module, if used, must occupy
• Display can show bar code fields up to a maximum length of
slot 6 location
48 characters. Characters might wrap to 2 rows after 24 characters
• A maximum of two 10A SSR FM modules can be used in the F4T
• Program the bar code scanner to add an enter key (carriage return
and each will require space for 2 slots. Valid in slots 1, 2, 4 or 5
feed) at the end of each bar code data field sent to the F4T/D4T.
Wiring Termination—Touch-Safe Terminals
Refer to USB scanner user manual.
• Right-angle and front-screw terminal blocks for input, output
Trending
and power supply connections
• 4 user programmable charts
• Input, output and power terminals: touch safe, removable,
• 6 pens available per chart
12 to 30 AWG
• View analog sensors and process values
Real Time Clock with Battery Backup Counters
• Accuracy (typical): +/-3ppm over -15 to 50°C • Counts up or down, loads predetermined value on load signal
• Typical battery life: 10 years at 77°F (25°C) Linearization
• Field replaceable lithium battery • Interpolated or stepped
Number of Function Blocks by Ordering Option Logic
Function Block Basic Set 1 Set 2
• And, nand, or, nor, equal, not equal, latch, flip-flop
Math
Alarm 6 8 14 • Average, process scale, switch over, deviation scale,
Compare None 4 16 differential (subtract), ratio (divide), add, multiply, absolute
Counter None 4 16 difference, minimum, maximum, square root, sample and hold,
Linearization 4 4 8
pressure-to-altitude and dew point
Process Value
Logic None 12 24 • Sensor backup, average, crossover, wet bulb-dry bulb, switch over,
Math None 12 24 differential (subtract), ratio (divide), add, multiply, absolute
Process Value 4 4 8 difference, minimum, maximum, square root, altitude, Vaisala®
Special Output Function relative humidity and pressure-to-altitude
None 2 4 Special Output Function
(including compressor)
Timer None 6 16 • Compressor control (cool and/or dehumidify with single
compressor), motorized valve, sequencer
Variable 4 12 24
Timers
Compare • On pulse, delay, one shot or retentive
• Greater than, less than, equal, not equal, greater than or equal, less Variable
than or equal • User value for digital or analog variable
0.48 in. 4.33 in.
(12.2 mm) (109.98 mm)
Panel Mount Dimensions 4.35 in.
(110.4 mm)
4.33 in.
(109.98 mm)
4.625 in. 4.62 in.
Slot 1 Slot 2 Slot 3
(118 mm) (117.4 mm)
4.62 in.
(117.4 mm)

Accent Bar
Accent
Bar Bar
Accent 4.093 in. 4.09 in.
(104 mm)(103.96 mm)
4.09 in. USB Mini B
(103.96 mm)

Ethernet

4.723 in.
(120 mm) Slot 4 Slot 5 Slot 6 USB Type A
4.73 in.
(120.14 mm) (Quantity 2)
4.73 in.
(120.14 mm)

Mounting Panel
0.50 in. Mounting Panel
(12.7 mm)
0.50 in.
(12.7 mm)

Flush Mount Dimensions


4.62 in. 4.81 in.
(117.4 mm) (122.1 mm)
Flushmount Bracket

4.09 in.
(103.96 mm)

Mounting
Panel

Powered by Possibility
To be automatically connected to the nearest International Technical Sales Offices:
North American Technical Sales Office: Austria +43 6244 20129 0 India +91 40 6661 2700 Mexico +52 442 256 2200
China +86 21 3532 8532 Italy +39 02 458 8841 Singapore +65 6773 9488
France +33 1 41 32 79 70 Japan +81 3 3518 6630 Spain +34 91 675 1292
1-800-WATLOW2 • www.watlow.com Germany +49 7253 9400 0 Korea +82 2 2169 2600 Taiwan +886 7 288 5168
UK +44 115 964 0777
©2021 Watlow Electric Manufacturing Company all rights reserved. WIN-D4T-0221
D4T Ordering Information
Base includes: 4.3 inch color graphical touch screen, standard bus communications, Ethernet Modbus® TCP
and SCPI protocol.
Part Number
①② ③ ④ ⑤ ⑥ ⑦ ⑧⑨ ⑩⑪ ⑫ ⑬⑭ ⑮
Data Power Supply Nbr. of Logging Nbr. of Auxiliary/
Logging Voltage, Connector Documentation, Accent Channels & Alarm Outputs,
Base Application & Trend Style, Watlow Logo Function Comm. Bar, Replacement Additional Input Hardware Digital Inputs &
Model Type Type Charts Screenprint Blocks Options Connectors & Custom Options Types Hardware
D4 T 5
③ Base Type ⑬⑭ Number of Logging Channels & Input Hardware Types
T= Touch screen Universal Input(s) (T/C, RTD 2- or 3-wire, 0-10VDC, 0-20mA)
④ Application Type U1 = 1 channel
1= Standard U2 = 2 channels
U3 = 3 channels
⑤ Data Logging and Trend Charts
U4 = 4 channels
J= Data logging
U5 = 5 channels
K= Data logging with encrypted files
U6 = 6 channels
L= Data logging with graphical trend charts
Thermistor Input(s)
M= Data logging with encrypted files, graphical trend charts
and batch processing with bar code data entry. T1 = 1 channel
T2 = 2 channels
Power Supply Voltage, Connector Style, T3 = 3 channels

Watlow Logo Screenprint T4 = 4 channels
Power Supply Watlow T5 = 5 channels
Power Supply Connector Logo T6 = 6 channels
1= 100 to 240VAC Right angle (standard) Yes Universal Input(s) (T/C, RTD 2-wire, 0-10VDC, 0-20mA)
2= 100 to 240VAC Right angle (standard) No 04 = 4 channels
3= 100 to 240VAC Front screw Yes 08 = 8 channels
4= 100 to 240VAC Front screw No 12 = 12 channels
5= 24 to 28VAC or VDC Right angle (standard) Yes 16 = 16 channels
6= 24 to 28VAC or VDC Right angle (standard) No 20 = 20 channels
7= 24 to 28VAC or VDC Front screw Yes 24 = 24 channels
8= 24 to 28VAC or VDC Front screw No Thermistor Input(s)
⑦ Function Blocks TA = 4 channels
Basic Set Set 1 Set 2 TB = 8 channels
A= X TC = 12 channels
B= X TD = 16 channels
C= X TE = 20 channels
TF = 24 channels
⑧⑨ Communication Options
Custom
AA = Modbus® TCP (Ethernet)
XX = Different channel quantity and combination options.
A3 = EtherNet/IP™ (w/Modbus® TCP) Contact factory for assistance.
Documentation, Accent Bar, Replacement Number of Auxiliary/Alarm Outputs,
⑩⑪ ⑮
Connectors & Custom Digital Inputs & Hardware
Decorated Brush Aluminum Options below are not available with 6 or 24 channel input models
Documentation Accent Bar A = None
DVD / QSG Gray Blue Red None Single Output
1A = Yes X C = 1 switched dc/open collector
1B = Yes X E = 1 mechanical relay 5A, Form C output
1C = Yes X F = 1 universal process/retransmit
1D = Yes X Multiple Digital Inputs/Outputs
1E = No X D = 6 digital I/O
1F = No X P = 3 universal process/retransmit outputs
B = 3 mechanical relay 5A, 2 Form C and 1 Form A (Form A
1G = No X shares a common with 1 Form C)
1H = No X J = 4 mechanical relay 5A, Form A
1J = Replacement connectors only - for the model number K = 2 SSRs Form A, 0.5 A
entered
T* = 2 SSRs at 10A
XX = Contact factory, other custom-firmware, preset parameters,
L = 4 SSRs at 2A each, SSRs grouped in 2 pairs with each pair
locked code, logo sharing a common
⑫ Additional Options Communications
5= None M = Modbus® RTU 232/485
Watlow®, Watlow SELECT® and COMPOSER® are registered trademarks of Watlow Electric Custom
Manufacturing Company. X = Different output quantity and combination options.
D4T™ is a trademark of Watlow Electric Manufacturing Company. Contact factory for assistance.
UL® is a registered trademark of Underwriter’s Laboratories Incorporated.
Modbus® is a registered trademark of Schneider Automation Incorporated. * Option “T” not available with digit 13 & 14, options U5, U6, T5, T6,
Vaisala® is a registered trademark of Vaisala OY Corporation. 20, 24, TE and TF.
Microsoft® and Windows® are registered trademarks of the Microsoft Corporation.

You might also like