gunt
WP 100
Deformation of bars under bending or torsion
Description Learning objectives/experiments
• elastic deformation of statically A dial gauge records the resulting de- • bending tests
determinate or indeterminate formation. The support blocks include · determination of the modulus of
beams under bending load clamping chucks to hold the torsion bars elasticity
• elastic torsion of round bars un- and supports for the bars in the bend · statically determinate systems
der twisting moment test. The supports offer a range of (beam mounted on two supports;
• influence of material, cross-sec- clamping options, enabling statically de- cantilever beam)
tion and clamping length on de- terminate or indeterminate bearing sup- · statically indeterminate systems
formation ports to be investigated. (dual-span beam)
· deformation of a beam dependent
Bending and torsion are typical loads to The twisting moment is applied by a on material, geometry (section
which components are subjected. The device mounted on a support block. The width, height and length), type of sup-
resultant stresses and deformations point of load application to generate the port and length of span
can lead to failure of the component. A bending moment is adjustable. · formulation of proportional relation-
number of different factors play a role in ships for the deformation
this, including the material, the cross- The various elements of the experiment • torsion tests
section of the bar, the clamping length are clearly laid-out and housed securely · determination of the shear modulus
and the method of bearing support. in a storage system. The complete ex- of various materials
perimental setup is arranged on the · angle of twist dependent on clamp-
WP 100 investigates the influence of frame. ing length, bar diameter
these factors on the deformation of a · formulation of proportional relation-
bar under bending load or twisting mo- ships for the angle of twist
ment. A set of test bars has been as-
sembled so as to permit direct compar-
ison of measuring results. The bar under
investigation is fixed to two movable sup-
port blocks and loaded down by a
weight.
G.U.N.T. Gerätebau GmbH, Hanskampring 15-17, D-22885 Barsbüttel, Telefon (040) 67 08 54-0, Fax (040) 67 08 54-42, Email [email protected], Web www.gunt.de
We reserve the right to modify our products without any notifications. Page 1/3 - 11.2023
gunt
WP 100
Deformation of bars under bending or torsion
Specification
[1] elastic deformation of bars under bending or tor-
sion
[2] bending tests with statically determinate and inde-
terminate systems
[3] torsion tests with a statically determinate system
[4] supports in the bending test may be clamped or
free
[5] 2 adjustable blocks with clamping chuck for torsion
tests and supports for bending tests
[6] weights to generate the bending or twisting mo-
ment
[7] dial gauge with bracket
[8] storage system to house the components
1 beam, 2 clamp fixing for bending test, 3 support block, 4 weight, 5 device to generate the Technical data
twisting moment in the torsion test, 6 support for bending test, 7 clamping chuck for tor-
sion test, 8 dial gauge
17 bars for bending tests
• material: aluminium, steel, brass, copper
• height with LxW 510x20mm: h=3…10mm
• width with LxH 510x5mm: w=10…30mm
• length with WxH 20x4mm: l=210…510mm
• LxWxH: 20x4x510mm (Al, St, brass, Cu)
• LxWxH: 10x10x510mm (aluminium)
22 torsion bars
• material: aluminium, steel, brass, copper
• length with Ø 10mm: 50…640mm (aluminium)
• ØxL: 10x50mm/10x340mm (aluminium, steel, cop-
per, brass)
• diameter with L=50/340mm: Ø 5…12mm (steel)
Dial gauge
• 0…10mm, graduation: 0,01mm
Beam deflection of a statically determinate (left) and indeterminate (right) system:
1 cantilever beam, 2 simply supported beam, 3 propped cantilever, 4 built in beam Tape measure
• graduation: 0,01m
Weights
• 1x 100g (hanger)
• 1x 100g, 1x 400g, 1x 500g, 1x 900g
LxWxH: 1000x250x200mm
Weight: approx. 18kg
LxWxH: 1170x480x207mm (storage system)
Weight: approx. 12kg (storage system)
Scope of delivery
1 frame
2 support blocks
1 device to generate the twisting moment
17 bars for bending test
Torsion on round bar: F applied force, a lever arm, r radius, γ shear angle, φ angle of twist 22 torsion bars
1 dial gauge with bracket, 1 tape measure
1 set of weights
2 hexagon socket wrenches
1 storage system with foam inlay
1 set of instructional material
G.U.N.T. Gerätebau GmbH, Hanskampring 15-17, D-22885 Barsbüttel, Telefon (040) 67 08 54-0, Fax (040) 67 08 54-42, Email [email protected], Web www.gunt.de
We reserve the right to modify our products without any notifications. Page 2/3 - 11.2023