INSTALLATION AND MAINTENANCE INSTRUCTIONS

I56-3604-004
Farenhyt™ Series

12 Clintonville Road, Northford, CT 06472-1610


Phone: 203-484-7161 Fax: 203-484-7118
IDP-Minimon Monitor Module www.Farenhyt.com

SPECIFICATIONS
Nominal Operating Voltage: 15-32 VDC
Average Operating Current: 375µA Maximum (group poll); 350μA (direct poll); 600µA Maximum Communicating, IDC Shorted)
EOL Resistance: 47K Ohms
Maximum SLC Wiring Resistance: 40 Ohms
Max. IDC Wiring Resistance: 1,500 Ohms
Maximum IDC Voltage: 11 Volts
Maximum IDC Current: 450µA
Temperature Range: 32˚F to 120˚F (0˚C to 49˚C)
Humidity: 10% to 93% Non-condensing
Dimensions: 1.3" H x 2.75" W x 0.5" D
Wire length: 6" minimum

BEFORE INSTALLING MOUNTING AND WIRING


This information is included as a quick reference installation guide. Refer to NOTE: This module is intended to be wired and mounted without rigid con-
the control panel installation manual for detailed system information. If the nections inside a standard electrical box. All wiring must conform to appli-
modules will be installed in an existing operational system, inform the opera- cable local codes, ordinances and regulations.
tor and local authority that the system will be temporarily out of service. Dis- 1. Connect the red (+) and black (–) wires to the positive and negative
connect power to the control panel before installing the modules. loop power leads of the signaling line circuit (SLC).
NOTICE: This manual should be left with the owner/user of this equipment. 2. Connect the violet (+) and yellow (–) wires to a two-wire, normally
GENERAL DESCRIPTION open initiating loop.
The IDP-Minimon monitor module can be installed in a single gang junction 3. Install the specified EOL resistor value to terminate the initiating loop.
box directly behind the monitored unit. Its small size and light weight allow 4. Set the address on the module per job drawings.
it to be installed without rigid mounting (see Figure 1). The IDP-Minimon is 5. Install the module in the desired mounting location.
intended for use in intelligent, two-wire systems where the individual address
of each module is selected using rotary switches. It provides a Class B initiat-
ing device circuit for normally open contact fire alarm and security devices. NOTE: All references to power limited represent “Power Limited (Class 2)”.

COMPATIBILITY REQUIREMENTS
FIGURE 2. TYPICAL CLASS B STYLE B INITIATING DEVICE
To ensure proper operation, this module shall be connected to a compat-
CIRCUIT CONFIGURATION:
ible Honeywell Farenhyt series system control panel (list available from
Honeywell).
UL LISTED
FIGURE 1: COMPATIBLE
CONTROL SIGNAL LINE CIRCUIT (SLC)
PANEL
(+) TO
NEXT
(–) DEVICE

ALL WIRING 14
15 0 1
2
01
2

SHOWN IS 13 3 3
12 4 4
11 5 5
9 8 76
SUPERVISED AND 10 9 8 7 6

TENS ONES
POWER LIMITED )–( )+( (+) (–)

YELLOW BLACK

VIOLET RED

47k EOL
INCLUDED
(ELR-47k)

C0614-02

C1063-00

Farenhyt™ is a trademark of and Honeywell® is a registered trademark of Honeywell International, Inc.


 1 I56-3604-004
©2017 Honeywell. 04-21