FN-LCD-N - LCD NETWORK ANNUNCIATOR

STANDARD FEATURES
 UL 864 9th Edition Listed
 320 character liquid crystal display (8 line x 40 character)
 LED indicators for Fire, Supervisory Alarm, Pre-Alarm, Fire
Output Active, Power On, On Test, Panel Sounder
Silenced, Delay Active, More Events, Point Bypassed,
General Trouble, Power Trouble, System Trouble & NAC
Trouble

DESCRIPTION  Dual RS485 ports for primary fire network


 RS485 slave bus for expansion - up to 32 FN-4127-IO
The FN-LCD-N type LCD network annunciator is de-
boards or up to 15 FN-LCD-S serial annunciators and up to
signed to be used with the FireNET® analog addressa- 17 FN-4127-IO boards
ble system. It allows for remote access, monitoring, and
control of the FireNET® system throughout the building.  2 built-in RS-232 interfaces for programming via a PC and
serial printer interface
The FN-LCD-N is a true network annunciator that can
access, monitor, and control any or all FireNET® panels  4 on board programmable Form C relays rated at 1 Amp at
in the network. Each FN-LCD-N is completely inde- 30VDC (Fire, Supervisory, Trouble & Auxiliary)
pendent. The highly intuitive user interface and 320  Same controls as the FireNET® fire panel (Reset, Panel
character LCD display of the FN-LCD-N is exactly the Sounder Silence, Lamp Test, Alarm Silence, Re-sound
same as the FireNET® panel. In addition to routing any Alarm, Fire Drill, Programmable Function, More Events,
panel in the network to the FN-LCD-N, every event cat- More Fire Events, Enter & Exit)
egory within each panel can also be individually routed,  Local piezo sounder for event notification
as well as routing of all remote control functions (reset,
alarm silence, re-sound alarm) from individual panels.  Supports user codes & firefighter key to enable access &
The FN-LCD-N supports the same RS485 expansion controls
port as the FireNET® panel, allowing for FireNET® ex-  Powered by FireNET® Aux 24VDC or UL fire listed Aux.
pansion boards and accessories to be connected to the 24VDC supply
network annunciator.
 Available in red or gray, and can be surface or flush
The FN-LCD-N also has (4) output relays for fire, su- mounted (using trim ring)
pervisory, trouble & auxiliary. The relays are program-  True network annunciator, any or all panels can be routed
mable (except supervisory). to the FN-LCD-N. In addition, each event category can be
Security is established by the use of a password or fire- individually routed to the FN-LCD-N
fighters enable key. Designed to be aesthetically pleas-  Up to (64) FireNET® panels & FN-LCD-N's can be net-
ing, the FN-LCD-N is available in red or gray and can worked together in any combination
be surface or flush mounted using a standard trim ring
 500mA of auxiliary power available rated at 24VDC
kit.
 Auto-learn feature
 Built-in help & alarm information screens
PRODUCT LISTINGS  Fire drill function

UL 864, NFPA 70 California State  Each FN-LCD-N is completely independent


& 72: Fire Marshal  The FN-LCD-N can be configured to remote reset, silence,
Signaling Device 7120-0410:165 resound, any or all panels on the network in any combina-
S5694 tion

Specifications subject to change without notice. Continued on back.

Hochiki America Corporation Find latest revision at www.hochiki.com


7051 Village Drive, Suite 100, Buena Park, CA 90621-2268
Phone: 714/522-2246 Fax: 714/522-2268
Technical Support: 800-845-6692 or [email protected] F0071 07/2015
FN-LCD-N - LCD NETWORK ANNUNCIATOR
SPECIFICATIONS
Input DC 24 VDC @ 270mA Max. ( + Aux. Power Load)
Aux. Output DC 24 VDC @ 500mA
Dimensions 14.5” W x 10” H x 3.3” D
Weight 9.4 lbs
Color Red (optional gray)
Material ABS/steel enclosure
Operating Temperature 32° F (0° C) 120° F (49° C)
Relative Humidity 85% RH Non-Condensing
Display 8 line x 40 character LCD (320 characters total)
Network Dual RS485 ports (64 nodes max.)
Relay Outputs (4) From C 1amp @ 30 VDC
PC Port RS232
Printer Port RS232
Expansion Port RS232

ENGINEERING SPECIFICATION
The contractor shall furnish and install where indicated on the plans, the network annunciator model FN-LCD-N. The
FN-LCD-N connects to the FireNET® fire alarm control panel (FACP) network. The network annunciator is capable of
annunciating on its 320 character display and local buzzer, the condition of any FireNET® FACP or network annunci-
ator on the network. Up to 64 FN-LCD-N network annunciators or FireNET® FACP's may be connected together on
the network. The FN-LCD-N is UL Listed, and has surface or flush mount capability.

WIRING DIAGRAM

Conventional Relay Contacts


rated for 1A @ 30VDC. Must be
connected to power-limited
source (not supervised)
(resistive)

24VDC Output (500mA max)


typically used for low current
devices. See manual for
additional details
RS485 to IO Boards

Network Connections
See manual for details

Network LCD
annunciator
example

To AUX 24VDC of control


panel or UL Listed AUX
24VDC Power Supply

Hochiki America Corporation FN-LCD-N Specifications subject to change without notice.