From lab to production,

providing a window into the process

MDT4X2F Series
Pressure Sensors
With SIL2 Description
SIL2 and PL'c' rating with local and The MDT4X2F Pressure Sensor Series provides special features for
remote rezeroing capability critical field applications in high noise surroundings. The utilization
of unshielded cables is possible for long distance transmission free
of noise interference for the converted process pressure signal
4-20 mA. The MDT4X2F comes equipped with adjustable zero and
span side-mounted potentiometers. MDT4X2F Series mA sensors
can be rezeroed in two ways: locally via the zero potentiometer, or
remotely via shorting two pins together (contact closure). Optional
thermocouple or RTD configurations are available to provide melt
temperature.
Features
■ Simple unshielded two-wire cable connection in high
noise ambients
■ Efficient rezero adjustments can be made locally or
remotely to the sensor
■ 4-20 mA two-wire signal output
■ Installation for media temperatures up to 400°C
■ Adjustable zero and span, via side-mounted pots
■ Flexible capillary connection between stem with
diaphragm and housing
■ 3rd-party agency analysis (exida™) and self-certified
based on FMEDA analysis and internal audit
■ Meets Performance Level ‘c’ as defined by the Machinery
Directive (Category 1)
■ Meets the following compliance directives, when properly
installed and used:
■ – SIL2
■ – Machinery Directive EN ISO 13849-1
Amplified Transducers

Performance Characteristics Temperature Influence


Pressure Range: 0-17 bar to 0-2000 bar Diaphragm:
MDT422F ±0.5% FSO (up to Max. Temperature: 400ºC
Accuracy:
50 bar ±1% FSO); Zero Shift (due to MDT422F X < 0.2 bar/10ºC
MDT422F ±0.1% FSO (up temperature change): MDT462F X < 0.4 bar/10ºC
Repeatability: to 50 bar ±0.2% FSO); Housing:
MDT462F ±0.2% FSO Max. Temperature: 85ºC
Resolution: Infinite Zero Shift (due to
Maximum Overload ±0.2% FSO/10ºC
2x pressure range for range temperature change):
(without in"uencing MDT422 X ±0.1% f.s.v./10ºC
1000 and 1400 Sensitivity Shift (due to
operating data): up to 50 bar ±0.2% f.s.v./10ºC
6x pressure range max. 3000 temperature change):
Burst Pressure: MDT462 X ±0.4% f.s.v./10ºC
bar
Approvals & Self Certifications
Material in Contact 15-5 PH SST (Mat. No.
with Media: 1.4545) DyMax® coated CE: Directive 2004/108/EC
ISO 9001:2008 production
Electrical Characteristics ISO:
environment
4-arm Wheatstone bridge
Confguration: EN ISO 13849-1 meeting the
strain gage
performance requirements of a
Internal Shunt Calibration: 80% of full scale ±1% safety-related part of a control
PL'c':
Output Signal: 2-wire 4-20 mA system for Performance Level ‘c’
Supply Voltage: 12-36 Vdc (PL’c’) safety system when
installed per Category 1
Zero Balance: ±1%
SIL2: Safety Integrity Level 2
Locally via zero potentiometer,
Rezero Initiation: or remotely via short circuit
between pins “D” and “F”

“Short circuit” between con-


nections pins “E” and “F” at
Range Calibration 80% FSO:
the sensor or externally from
the control room

Maximum 1200* at 36 Vdc


Load Resistance:
Maximum 500* at 24 Vdc
Isolation Resistance: 1000M* at 50 Vdc
Ordering Guide

XDT4XXF-XX-XXX-XX/XX-XXX

Temperature
M = No temperature sensor
T = J type thermocouple Safety & Compliance
SIL2 = Safety Integrity Level 2
Transducer Configuration GCx = Guardian safety relay option
60 = Rigid stem
Flexible Capillary Length
62 = Rigid stem with flexible capillary
Blank = None
63 = Rigid stem with flexible capillary and temperature sensor
46 = 45.7 cm
20 = Rigid stem (+0.5% FSO)
76 = 76.2 cm
22 = Rigid stem with flexible capillary (+0.5% FSO)
32 = Rigid stem with flexible capillary and temperature sensor
(=0.5% FSO) Rigid Stem Length
7.6 = 7.6 cm
Mounting Thread 15 = 15.2 cm
1/2 = thread 1/2" 20 UNF M10 = M10 23 = 23.9 cm
M18 = thread M18 x 1.5 32 = 32 cm
46 = 46 cm
Pressure Range
171)2) = 0-17 bar
351) = 0-35 bar
501) = 0-50 bar
1C = 0-100 bar
2C = 0-200 bar
3.5C = 0-350 bar
5C = 0-500 bar
Standard mating connector Dynisco P/N 711600 or 6-pin mating connector
7C = 0-700 bar
1M = 0-1000 bar
cable assembly. For Guardian drawings and 8-pin wiring diagrams see
1.4M = 0-1400 bar "Guardian" at www.Dynisco.com.
2M = 0-2000 bar Shaded sections refer to standard configurations. Accuracy may be affected
1)
only MDT422F if non-standard configurations are used. For additional options please
2)
only M18 consult factory.

ACCESSORIES
Cleaning Tool Kit, Machining Tool Kit, Guardian (Machinery
Directive) Safety Relay—see Guardian Data Sheet for details; NaK
Fill; UPR Process Indicator, ATC Process Controller. For additional
options please contact the factory.
Dimensions

All dimensions are inches (mm) unless otherwise specified.

All dimensions are inches (mm) unless otherwise specified.


©2016. Dynisco reserves the right to make changes without notice.
Refer to www.dynisco.com for access to Operator Manual and other support documentation.
DSMDT422 www.dynisco.com
Rev: 0429

Dynisco Hotline 1-800-Dynisco Dynisco Europe, GmbH Dynisco Shanghai


38 Forge Parkway www.dynisco.com Pfaffenstr. 21 Phone +49 7131 297 0 Building 7A, No. 568 Phone +86 21 34074072-819
Franklin, MA 02038 Phone +1 508 541 9400 74078 Hellbronn Fax +49 7131 297 166 Longpan Rd Malu Toll Free +86 400 728 9117
USA Fax +1 508 541 6206 Germany Email [email protected] Jiading, 201801 China Fax +86 21 34074025
Email [email protected]