Mammography Solution
Integrated biopsy Unit
Advanced Biopsy Unit
for
Variable image resolution for different needs
50µm 100µm
Both Tomosynthesis and stereotactic support for
needle positioning
2D Tomosynthesis
The highest image quality and workflow
efficiency for interventional procedures
A new advanced biopsy unit for FUJIFILM state of the art digital mammography system
FUJIFILM supports the Pink Ribbon Campaign for
early detection of breast cancer
A new tool to support all interventional procedures with AMULET
Innovality outstanding image quality and workflow efficiency.
Accurate and Efficient Stereotactic Biopsy
The system is designed to support flexible positioning of tube and
detector, from -90°to +90°. Ergonomically designed arm rests and
disposable soft pads ensure patient comfort and safe positioning.
Irradiation field size can be easily adjusted, depending on
breast size and procedure needs. Convenient spacers can be
used in order to perform needle positioning in extremely
thin breasts, too.
AEC full automatic function is available for both scout (2D)
and Tomosynthesis exposures.
Prior images and studies can be viewed during biopsy, to
further improve accuracy.
Lateral approach (optional) Supports a variety of needle
Thanks to the new adapter, needle positioning Both CNB/FNB/Hook wire and
can be performed both vertically and laterally. VAB needles can be used in a
Accessing to the compressed breast in two wide range of sizes, for various
directions ensures the most precise targeting of models and manufacturers.
lesions which might be in a difficult position. Refer to technical specifications and to local
representatives for further information.
Tomosynthesis Biopsy (optional)
Targeting is supported using both tomosynthesis Using a tomosynthesis image, it makes it possible to target
and stereoscopic images: the choice depends on the lesion which cannot be found in 2D image.
operator confidence and lesion positioning. Thanks to easier lesion position identification, tomosynthesis
Tomosynthesis acquisition can be performed in both targeting results in a more efficient workflow and more simple
ST(Standard) and HR(High Resolution) modes, operation.
according to desired accuracy and lesion size.
Stereo imaging Tomosynthesis
HR: ±20°
ST: ±7.5°
2D image(0°) Tomo
2D image
-15° +15°
Overlapping breast structures Reconstructed images show overlapping
make lesions less visible structures separately
Difficult to identify a particular region Easier to locate a target than with
the conventional method
Main specifications Standard components
Exposure stand (FDR3500DRLH): Approx. 624 (W) ✕ 1270 (D) ✕ 1974 (H) mm / Approx. 370 kg / AC 200 / 208 / 220 / 230 / 240 V
•Control cabinet: Approx. 503 (W) ✕ 205 (D) ✕ 530 (H) mm / Approx. 20 kg
•Generator: Approx. 445 (W) ✕ 315 (D) ✕ 825 (H) mm / Approx. 70 kg
AWS (FDR-3000AWS): Approx. 700 (W) ✕ 420 (D) ✕ 1900 (H) mm / Approx. 90 kg (including protective shield and operation table) / Main unit: AC 100-240 V
The appearance and specifications may be subject to change.