F73A Duplex One in Service One Standby Softener Valve
F73A Duplex One in Service One Standby Softener Valve
X
ZL200620108588.0
17603(Old Model:F73)
Instruction Manual
Before the valve put into use, please fill in the below content so as to
help us to refer in the future.
Softener System Configuration
Tank Size:Dia. mm,Height mm;
Resin Volume L;Brine Tank Capacity L;
Hardness of Raw water mmol/L;
Pressure of Inlet Water MPa;
Control Valve Model ;Number ;
The Specification of Drain Line Flow Control ;
Injector No. .
Water Source: Ground-water□ Filtered Ground-water □Tap Water □
Other .
Parameter Set
Factory
Parameter Unit Actual Value
Default
Hour:
Time of Day Time of Day
Minute
Control Mode A-01/03/11/13 / A-01
Interval Backwash Time / F-00
Water Treatment Capacity m3 10.00
Resin Volume L. 50L
Feed Water Hardness mmol/L 1.2mmol/L
Regeneration Factor / 0.65
Unit Mode HU-01/02/03 / HU-01
Fast Rinse Time min. 10
Backwash Time min. 10
Brine & Slow Rinse Time min. 60
Brine Refill Time min. 05
Interval Regeneration Days D. 30
Signal Output Mode b-01
/ b-01
(02)
If there is no special requirement when product purchase, we choose
5# drain line flow control,and 6308 injector for the F73 standard
configuration.
MODEL 17603
Catalogue
Notice ...........................................................................................................
1. Product Overview .....................................................................................
1.1. Main Application &Applicability .............................................................
1.2. Product Characteristics .........................................................................
1.3. Service Condition ..................................................................................
1.4. Product Structure and Technical Parameters (The appearance is just
for reference. It is subjected to the real product.) ........................................
1.5. Installation .............................................................................................
2. Basic Setting & Usage .............................................................................
2.1. The Function of PC Board.....................................................................
2.2.Basic Setting & Usage ...........................................................................
3.Applications ...............................................................................................
3.1. Softener Flow Chart ..............................................................................
3.2. The Function and Connection of PC Board ..........................................
A. Signal Output Connector ..................................................................
B. Pressure Relief Output .....................................................................
C. Remote Handling Connector ............................................................
3.3. System Configuration and Flow Rate Curve.........................................
3.4. Parameter settlement ............................................................................
3.5. Parameter Enquiry and Setting .............................................................
3.6. Trial running...........................................................................................
3.7. Trouble-Shooting ...................................................................................
3.8. Spare Parts and Part Number ...............................................................
4. Warranty Card ..........................................................................................
I
MODEL 17603
Notice
To ensure normal operation of the valve, please consult with
professional installation or repairing personnel before use it.
If there are any of pipeline engineering and electric works, there must
be finished by professional at the time of installation.
Do not use the control valve with the water that is unsafe or unknown
quality.
Depending on the changing of working environment and water
requirement, each parameter of softener should be adjusted accordingly.
When the water treatment capacity is too low, please check the resin. If
the reason is shortage of resin, please add; if the resin is turn to reddish
brown or broken, please replace.
Test water periodically to verify that system is performing satisfactorily.
Sodium used in the water softening process should be considered as
part your overall dietary salt intake. Contact doctor if you are on a low
sodium diet.
Ensure that there is solid salt all the time in the brine tank in the course
of using, when this valve is used for softening. The brine tank should be
added the clean water softening salts only, at least 99.5% pure,
forbidding use the fine salt.
Do not put the valve near the hot resource, high humidity, corrosive,
intense magnetic field or intense librations environment. And do not
leave it outside.
Forbidden to carry the injector body. Avoid using injector body as
support to carry the system.
Forbidden to use the brine tube or other connectors as support to carry
the system.
1
MODEL F73(17603)
Please use this product under the water temperature between 5~50℃,
water pressure 0.15~0.6MPa. Failure to use this product under such
conditions voids the warranty.
If the water pressure exceeds 0.6Mpa, a pressure reducing valve must
be installed before the water inlet. While, if the water pressure under
0.15MPa, a booster pump must be installed before the water inlet.
It is suggest to install PPR pipe, corrugated pipe or UPVC pipe, instead
of TTLSG pipe.
Do not let children touch or play, because carelessness operating may
cause the procedure changed.
When the attached cables of this product and transformer are changed,
they must be changed to the one that is from our factory.
2
MODEL F73(17603)
1. Product Overview
1.1. Main Application &Applicability
Used for softening or demineralization water treatment systems
Be suitable for continuing supply water occasion
3
MODEL F73(17603)
interchanged in a valve.
By program selection to choose down-flow regeneration and up-flow
regeneration.
Interval backwash times (Suitable for up-flow regeneration
type)
It could set up interval backwash times for up-flow regeneration type,
which means several times of services but one time of backwash. The
setting of interval backwash time is depending on the local water turbidity.
(The lower the turbidity is, the longer of the interval backwash time can
be set)
Signal output
There is a signal output connector on main control board. It is for
controlling external wiring (Refer to Figure from Figure3-1 to Figure 3-8).
There are two kinds of output modes. b-01 Mode: Turn on start of
regeneration and shut off end of regeneration; b-02 Mode: Signal
available only intervals of regeneration cycles and in service.
4
MODEL F73(17603)
5
MODEL F73(17603)
In the above table, First Grade Na+ represents First Grade Na+
Exchanger. Second Grade Na+ represents Second Grade Na+
Exchanger.
When the water turbidity exceeds the conditions, a filter should be
installed on the inlet of control valve.
When the water hardness exceeds the conditions, the outlet water
hardness will hardly reach the requirement of boiler feed water(0.03
mmol/L). It is suggested to adopt second grade softener.
6
MODEL F73(17603)
@0.3MPa
1.5. Installation
A. Installation notice
Before installation, read all those instructions completely. Then
obtain all materials and tools needed for installation.
The installation of product, pipes and circuits, should be
accomplished by professional to ensure the product can operate
normally.
Perform installation according to the relative pipeline regulations
and the specification of Water Inlet, Water Outlet, Drain Outlet, Brine
Line Connector.
B. Device location
①The softener should be located close to drain.
②Ensure the unit is installed in enough space for operating and
maintenance.
③Brine tank need to be close to softener.
④The unit should be kept away the heater, and not be exposed outdoor.
Sunshine or rain will cause the system damage.
⑤Please avoid to install the system in one Acid/Alkaline, Magnetic or
strong virbration circumstance, because above factors will cause the
system disorder.
⑥Do not install the filter or softener, drain pipeline in circumstance which
temperature may drop below 5℃, or above 50℃.
⑦One place is recommended to install the system which causes the
minimum loss in case of water leaking.
7
MODEL F73(17603)
C. Pipeline installation
① Install control valve
a. As the Figure 1-1
shows, select the riser
pipe with 26.7mm OD,
glue the riser pipe to the
bottom strainer and put it
into the mineral tank, cut
off the exceeding tube
out of tank top opening.
b. Fill specified quantity
of resin to the tank (The
distance between two
tank centers is 375mm).
c. Screw top distributor into valve.
d. Insert the riser tube into control valve and screw tight control valve.
e. Install another tank with base connector as above steps.
Notice:
● The length of riser tube should be neither higher 2mm nor lower
5mm tank top opening height, and its top end should be
rounded to avoid damage of O-ring inside the valve.
● Avoid floccules substance together with resin to be filled in the
mineral tank.
● Avoid O-ring inside control valve falling out while rotating it on
the tank.
② Install animated connector
As Figure1-2 shows, put the sealing ring into nut of animated
connector, and screw in water inlet.
③ Install flow meter
As Figure1-2 shows, put the sealing ring into nut of flow meter,
screw in water outlet; insert the sensor into flow meter.
8
MODEL F73(17603)
④ Pipeline connection
a. As Figure1-3 shows, install a pressure gauge in water inlet.
b. Install valve A, valve B, valve C and valve D in inlet, outlet and
between the inlet and outlet pipeline. Valve D is a sample valve. (Or
adopt F70C bypass valve).
c. Inlet pipeline should be in parallel with outlet pipeline. Support inlet
and outlet pipeline with fixed holder.
9
MODEL F73(17603)
Notice
● If making a soldered copper installation should do all sweat
soldering before connecting pipes to the valve. Torch heat will
damage plastic parts.
● When turning threaded pipe fittings onto plastic fitting, use care
not to cross thread or broken valve.
⑤ Install drain pipeline
a. As the Figure 1-4 shows, slide the drain hose
connector into drain outlet.
b. Insert drain line flow control into drain outlet
c. Screw
drain hose
connector
into drain
outlet, and
lock it.
d. Locate
the drain hose well as the Figure1-4 show.
Notice:
● Control valve should be higher than drain outlet, and be better
not far from the drain hose.
● Be sure not connect drain with sewer, and leave a certain space
between them, avoid wastewater be absorbing to the water
treatment equipment, such as showed in the Figure1-4.
● If necessary can use a container to take drainage, the drain
hose should be kept in certain distance from container as well.
10
MODEL F73(17603)
11
MODEL F73(17603)
12
MODEL F73(17603)
13
MODEL F73(17603)
14
MODEL F73(17603)
Fast Rinse
10min. 0~99∶ 59 Fast rinse time (Minute)
Time
Backwash
10min. 0~99∶ 59 Backwash time (Minute)
Time
Brine &
Slow
60min. 0~99∶ 59 Brine &Slow rinse time (Minute)
Rinse
Time
Brine Refill
5min. 0~99∶ 59 Brine refill time (Minute)
Time
Maximum
Regenerate on the day even through
Interval
H-30 30 0~40 the available volume of treated water
Regenerat
do not drop to zero (0).
ion Days
Mode 01: Signal turn on start of
regeneration and shut off end of
regeneration. (Connection refer to
Output
the Figure P4)
Control b-01 01 01or 02
Mode 02: Signal available only
Mode
intervals of regeneration cycles and
in service. (Connection refer to the
Figure P4)
B. Process Display
15
MODEL F73(17603)
Notice:
When tank U1 in Service while tank U2 is standby: Figure A/B/C/D
displayed every 5 seconds in cycle.
When tank U1 in Service while tank U2 in Fast Rinse: Figure
E/F/G/H/J displayed every 5 seconds in cycle.
Service tank switching from U1 tank to U2 tank display as Figure I;
Service tank switching from U2 tank to U1 tank display as Figure Q.
When tank U2 in Service while tank U1 in Backwash: Figure L/F/M/H/J
displayed every 5 seconds in cycle.
When tank U2 in service while tank U2 in Brine & Slow Rinse: Figure
N/F/M/H/J displayed every 5 seconds in cycle.
When U2 in Service while tank U2 in Brine Refill: Figure O/F/M/H/J
displayed every 5 seconds in cycle.
When tank U2 in Service while tank U1 is standby: Figure P/B/C/D
displayed every 5 seconds in cycle.
Display screen show “-00-”or“F-00”when motor is switching.
The time of day figure flash continuously, such as “12:12” flash,
indicates long outage of power. It reminds to reset the time of day.
The display will show the error code, such as “-E1-” when the system
is in error.
C. Usage
16
MODEL F73(17603)
When the outlet water hardness is unqualified, please press the and
the valve will temporary regenerate again (It will not affect the original set
operation cycle).
③ When the feed water hardness change a lot, you can adjust the
water treatment capacity as follow:
Press and hold both and for 5 seconds to lift the lock status.
Press , and the light on, then press , the digital area show the
control mode (Such as show A-01), then press and the digit area will
show the given water treatment capacity; Press again, and digital
flash set cycle water capacity. Press or continuously, reset the
capacity value (Or water hardness). Press and hear a sound “Di”,
then finish the adjustment. Press exit and turn back the service
status.
The estimates of cycle water treatment capacity can refer to the
professional application instruction. When select A-03 or A-13 as the
control mode, controller will calculate the cycle water treatment capacity
automatically according to the inputting feed water hardness, resin
volume and exchange factor.
The regeneration parameters have been set when control valve left
factory. Generally, it does not need to reset. If you want enquiry and
modify the setting, you can refer to the professional application
specification.
17
MODEL F73(17603)
3.Applications
3.1. Softener Flow Chart
18
MODEL F73(17603)
19
MODEL F73(17603)
20
MODEL F73(17603)
Function:
When valve in service status, if soft water tank is short of water,
solenoid valve is open to supply soft water, but if water tank has enough
water, solenoid valve is closed, so no soft water supplied.
When the valve is in backwash status, there is no signal output. So,
solenoid valve is closed, and now water flow into soft water tank.
21
MODEL F73(17603)
Function:
When inlet pressure is high, install a solenoid valve on inlet to
ensure valve switching properly. When valve is exactly at position of U1
tank in service, U2 tank standby, U1 tank in service while U2 tank in
backwash, U1 tank in service while U2 tank in backwash solenoid valve
is open. When valve is switching, solenoid valve is closed, no water flow
into valve to ensure valve switching properly.
2) Liquid Level Controller Controls Inlet Pump (Two-phase motor) (Set
b-01)
Instruction: For the system using well or middle-tank supplying water,
switch of liquid level controller and valve together control pump opening
or closing. The wiring refers to Figure 3-5:
22
MODEL F73(17603)
Function:
When valve in standby status, if water tank is short of water, start up
pump, but if water tank has enough water, the switch of liquid level
controller is closed, so pump doesn’t work.
When valve in regeneration cycle, inlet always has water no matter
what water condition in water tank is. As Runxin valve no water pass
outlet in regeneration cycle, it ensure no lots of water fill into brine tank.
A liquid switch at the top opening of well or in middle water tank in
RO system protect pump from working without water in case of out of
raw water.
3) Liquid Level Switch in Water Tank Controls Inlet Pump (Three-phase
motor) (Set b-01)
This application applies the same principal as two-phase motor, only
difference is changed to a three-phase motor with an AC contactor
(Figure 3-6).
23
MODEL F73(17603)
24
MODEL F73(17603)
Attention: The flow rate calculation is based on linear velocity 25m/h; the
minimum salt consumption for regeneration calculation is based on salt
consumption 150g / L (Resin).
B. Flow Rate Characteristic
1)Pressure flow rate curve
25
MODEL F73(17603)
Inlet
Draw Rate(L/M)
Pressure
6305 6307 6310
6301 6302 6303 6304 6306 6308 6309
MPa Whit Purpl Orang
Coffee Pink Yellow Blue Black Red Green
e e e
0.15 0.81 1.12 1.58 2.21 2.45 3.30 3.44 4.08 5.19 5.69
0.20 0.95 1.41 1.87 2.53 2.89 3.88 4.21 4.83 5.36 6.80
0.25 0.99 1.61 2.08 2.79 3.30 4.30 4.66 5.39 6.86 7.65
0.30 1.30 1.81 2.18 3.05 3.66 4.74 5.15 5.95 7.50 8.60
0.35 1.45 1.96 2.39 3.27 3.94 5.02 5.55 6.51 8.30 9.57
0.40 1.56 2.12 2.55 3.50 4.25 5.41 5.88 6.77 8.74 9.90
26
MODEL F73(17603)
27
MODEL F73(17603)
28
MODEL F73(17603)
29
MODEL F73(17603)
30
MODEL F73(17603)
1. In resin volume display status, it
shows 100 L. Press and enters
into program set mode. and 100
Resin value flash.
Volume 2. Press or to adjust the
volume value (L).
3. Press to finish adjustment then
press to turn back.
1. In feed water hardness display
status, it shows yd1.2. Press and
enter into program set mode. and
Feed Water 1.2 value flash.
Hardness 2. Press or to adjust the
hardness value(mmol/L)
3. Press to finish adjustment then
press to turn back.
1. In exchange factor display status, it
shows AL.55. Press and enter into
program set mode. and 55 flash.
2. Press or to adjust the exchange
Exchange
factor value.
Factor
3. Press to adjust the exchange
factor value then press to turn
back.
31
MODEL F73(17603)
1. In backwash time display status, it
shows and 2-10. Press and
enter into program set mode. and
10 flash.
Backwash 2. Press or to adjust the backwash
Time time (minute).
3. Press to finish adjustment then
press to turn back.
32
MODEL F73(17603)
33
MODEL F73(17603)
34
MODEL F73(17603)
Notice:
If water inflow too fast, the media in tank will be damaged. When water
inflow slowly, there is a sound of air emptying from drain pipeline.
After changing resin, please empty air in the resin according to the
above Step C.
In the process of trial running, please check the water situation in all
position, ensuring there is no resin leakage.
The time for Backwash, Brine & Slow Rinse, Brine Refill and Fast
Rinse position can be set and executed according to the calculation in
the formula or suggestions from the control valve suppliers.
35
MODEL F73(17603)
3.7. Trouble-Shooting
A. Control Valve Fault
36
MODEL F73(17603)
37
MODEL F73(17603)
A. Locating signal wiring
A. Check and connect locating
breakdown.
signal wiring.
9. Control B. Controller is faulty.
B. Replace controller.
cycle C. Foreign material stuck
C. Take out foreign material.
continuously. the driving gear.
D. Check program setting and
D. Time of regeneration
reset.
steps were set to zero.
A. Internal valve leak.
A. Check and repair valve body or
B. When electricity fails to
10. Drain replace it.
supply, valve stops
flows B. Adjust valve to service position
backwash or fast rinse
continuously. or turn off bypass valve and restart
position.
when electricity supply.
A. Water pressure too low
or not stable. A. Increase water pressure.
11.
B. Injector is plugged or B. Clean or replace injector.
Interrupted or
faulty. C. Check and find the reason.
irregular
C. Air in resin tank. D. Clean the floccules in resin tank.
brine.
D. Floccules in resin tank
during backwash.
A. Foreign material in valve
which makes valve can’t be
A. Clean foreign material in valve
12. Water closed completely.
body.
flow out from B. Hard water mixed in
B. Change valve core or sealing
drain or brine valve body.
ring.
pipe after C. Water pressure is too
C. Reduce water pressure or use
regeneration. high which result in valve
pressure release function.
doesn’t get the right
position.
38
MODEL F73(17603)
A. Regenerate according to the
correct operation requirement.
A. Regenerate not properly.
B. Increase backwash flow rate
B. Fouled resin bed.
and time then clean or change
C. Salt setting not proper.
resin.
D. Softener setting not
14. Circle C. Readjust brine drawing time.
proper.
capacity D. According to the test of outlet
E. Raw water quality
decreases. water, recount and reset.
deterioration.
E. Regenerate unit by manual
F. Turbine in flow meter was
temporary then reset regeneration
stuck.
cycle.
F. Disassemble flow meter and
clean it or replace a new turbine.
B. Controller Fault
39
MODEL F73(17603)
controller fails to work.
C. Control board is faulty.
40
MODEL F73(17603)
41
MODEL F73(17603)
42
MODEL F73(17603)
Moving Seal
24 8370001 2 51 Screw, Cross 8940002 2
Ring
Screw, Cross
25 Shaft 8258011 2 52 8909003 4
ST3.9X19
Anti-friction
26 8216012 2 53 Connection Plate 8152006 1
Washer
Screw, Cross
27 O-ring 43.7x3.55 8378123 4 54 8909016 2
ST3.9X19
Flow Meter Connector & Animated Connector:
43
MODEL F73(17603)
4. Warranty Card
Dear client:
This warranty card is the guarantee proof of RUNXIN brand
multi-functional flow control valve. It is kept by client self. You could get
the after-sales services from the supplier which is appointed by RUNXIN
manufacturer. Please keep it properly. It couldn’t be retrieved if lost.
1. Guarantee period expired. (One year);
2. Damage resulting from using, maintenance, and keeping that are not
in accordance with the instruction;
3. Damage resulting from repairing not by the appointed maintenance
personnel;
4. Content in guarantee proof is unconfirmed with the label on the real
good or be altered;
5. Damage resulting from force majeure.
Product Multi-functional Flow Control Valve
Name for Water Treatment Systems
Code of Valve
Model
Body
Purchase
Company Tel/Cel.
Name
Problem
Solution
Maintenance
Date of Date of
Man
Reparing Accomplishment
Signature
When product need warranty service, please fill in the below content
and sent this card together with the product to the appointed suppliers or
44
MODEL F73(17603)
Runxin company.
End-user
Company Tel/Cel.
Name
Purchase
Company Tel/Cel.
Name
Model Code of Valve Body
Resin Tank Size Raw Water Hardness
Tank size φ ×
L mmol/L
Water Source:
Water Treatment Backwash Time
Ground-water □ Tap Water
Capacity m3 min
□
Brine & Slow Rinse Time Brine Refill Time Fast Rinse Time
min min min
Problem
Description
45